<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
		<id>https://www.fokus-diagnostik.de/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Administrator</id>
		<title>SRM Ergometer Fokus:Diagnostik - User contributions [en]</title>
		<link rel="self" type="application/atom+xml" href="https://www.fokus-diagnostik.de/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Administrator"/>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php/Special:Contributions/Administrator"/>
		<updated>2026-11-22T10:31:57Z</updated>
		<subtitle>User contributions</subtitle>
		<generator>MediaWiki 1.25.1</generator>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Template:Language&amp;diff=2060</id>
		<title>Template:Language</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Template:Language&amp;diff=2060"/>
				<updated>2017-08-28T11:56:43Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: Undo revision 2059 by Administrator (talk)&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[:{{{1}}}:{{{2}}}|{{{3}}}]]&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Internationale_Literatur_zum_SRM-Ergometer&amp;diff=2058</id>
		<title>Internationale Literatur zum SRM-Ergometer</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Internationale_Literatur_zum_SRM-Ergometer&amp;diff=2058"/>
				<updated>2017-07-11T20:46:42Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{languages&lt;br /&gt;
|de=Internationale Literatur zum SRM-Ergometer&lt;br /&gt;
|en=International publications on SRM Ergometer&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
In der folgenden Tabelle sind  diverese Sammlungen an Publikationen zu verschiedenen Themen als PDF-Dateien verlinkt.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot;&lt;br /&gt;
|+ style=&amp;quot;padding-bottom:1em&amp;quot; | Publikationen des SRM-Ergometers &lt;br /&gt;
|- class=&amp;quot;hintergrundfarbe6&amp;quot;&lt;br /&gt;
!style=&amp;quot;width:60%&amp;quot;| Publikationen!! style=&amp;quot;width:30%&amp;quot;| Letztes Update&lt;br /&gt;
|-&lt;br /&gt;
| [[Media:SRM_Scientific_Publications_05-2017.pdf|SRM Scientific Publications]]&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| Mai 2017 &lt;br /&gt;
|-&lt;br /&gt;
| [[Media:Torque_publications_2015.pdf|Torque Publications]]&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| Januar 2015&lt;br /&gt;
|-&lt;br /&gt;
| [[Media:Eccentric_Chainrings_2015.pdf|Eccentric Chainrings Publications]]&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| April 2015&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
(In der folgenden Tabelle finden Sie aktuelle internationale Literaturstellen in denen das SRM - Ergometer und / oder die SRM - Trainingssysteme für wissenschaftliche Untersuchungen eingesetzt wurden.&lt;br /&gt;
[[Media:SRM_Scientific_Publications_06-2016.pdf|Hier]] finden sie die internationalen Literaturstellen in einem pfd - Dokument zusammengefasst.)&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot;&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|- class=&amp;quot;hintergrundfarbe6&amp;quot;&lt;br /&gt;
!style=&amp;quot;width:30%&amp;quot;| Autor!! style=&amp;quot;width:30%&amp;quot; | Titel!! style=&amp;quot;width:30%&amp;quot; | Publikation&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Abbiss, C.R.; Quod, M.J.; Martin, David T.; Netto, K.J.; Nosaka, K.; Lee, H. et al. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Dynamic pacing strategies during the cycle phase of an Ironman triathlon.  &lt;br /&gt;
|style=&amp;quot;vertical-align:top&amp;quot;| Med Sci Sports Exerc 38 (4), S. 726–734&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Abbiss, C.R.; Quod, M.J.; Levin, G.; Martin, D.T.; Laursen, P.B. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Accuracy of the Velotron ergometer and SRM power meter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 30 (2), S. 107–112.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Abel, T.; Burkett, B.; Schneider, S.; Lindschulten, R.; Strüder, H. K. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The exercise profile of an ultra-long handcycling race: the Styrkeprøven experience.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Spinal Cord 48 (12), S. 894–898.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Antonutto, G.; Capelli, C.; Girardis, M.; Zamparo, P.; di Prampero P.E. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of microgravity on maximal power of lower limbs during very short efforts in humans.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Physiol 86(1), S. 85-92.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Arkesteijn, M.; Hopker, J.; Jobson, S.; Passfield, L. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The Effect of Turbo Trainer Cycling on Pedalling Technique and Cycling Efficiency.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 34 (06), S. 520–525&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M. J.; Gore, C. J.; Burge, C. M.; Clough, M. L.; Bourdon, P. C.; Dobson, G. P.; Hahn, A. G. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Skin-prick blood samples are reliable for estimating Hb mass with the CO-dilution technique.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 79 (6), S. 535–537.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M. J.; Gore, C. J.; Dobson, G. P.; Boston, T. T.; Parisotto, R.; Emslie, K. R. et al. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Simulated moderate altitude elevates serum erythropoietin but does not increase reticulocyte production in well-trained runners.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 81 (5), S. 428–435&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Gore, C. J.; Dobson, G. P.; Hahn, A. G. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| &amp;quot;Live high, train low&amp;quot; does not change the total haemoglobin mass of male endurance athletes sleeping at a simulated altitude of 3000 m for 23 nights. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 80 (5), S. 479–484.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Gore, C. J.; Martin, D. T.; Dobson, G. P.; Hahn, A. G. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of a 12-day &amp;quot;live high, train low&amp;quot; camp on reticulocyte production and haemoglobin mass in elite female road cyclists.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 80 (5), S. 472–478.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Hahn, A. G.; Martin, D. T.; Logan, P.; Parisotto, R.; Gore, C. J. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| A comparison of the physiological response to simulated altitude exposure and r-HuEpo administration.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 19 (11), S. 831–837&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Gore, C.J.; Parisotto, R.; Sharpe, K.; Hopkins, W.G.; Hahn, A.G. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effect of altitude on second-generation blood tests to detect erythropoietin abuse by athletes.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Haematologica 88 (9), S. 1053–1062&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Aughey, R. J.; Clark, S. A.; Gore, C. J.; Townsend, N. E.; Hahn, A. G.; Kinsman, T. A. et al. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Interspersed normoxia during live high, train low interventions reverses an early reduction in muscle Na+, K +ATPase activity in well-trained athletes.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 98 (3), S. 299–309&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Aughey, R. J.; Gore, C. J.; Hahn, A. G.; Garnham, A. P.; Clark, S. A.; Petersen, A. C. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Chronic intermittent hypoxia and incremental cycling exercise independently depress muscle in vitro maximal Na+-K+-ATPase activity in well-trained athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 98 (1), S. 186–192&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashman, S.B.; Monk, T.H.; Kupfer, D.J.; Clark, C.H.; Myers, F.S.; Frank, E.; Leibenluft (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Relationship between social rhythms and mood in patients with rapid cycling bipolar disorder.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Psychiatry Res 86 (1), S. 1–8&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Austin, N.; Nilwik, R.; Herzog, W. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| In vivo operational fascicle lengths of vastus lateralis during submaximal and maximal cycling.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Biomech 43 (12), S. 2394–2399&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Balmer, J.; Bird, S.; Davison, R.C.R.; Doherty, M.; Smith, P. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Mechanically braked Wingate powers: agreement between SRM, corrected and conventional methods of measurement.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 22 (7), S. 661–667&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Bird, S.; Davison, R.; Lucia, A. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effect of age on 16.1-km time-trial performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 26 (2), S. 197–206&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Davison, R.C.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Peak power predicts performance power during an outdoor 16.1-km cycling time trial.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 32 (8), S. 1485–1490&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Balmer, J.; Davison, R.C.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reliability of an air-braked ergometer to record peak power during a maximal cycling test.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 32 (10), S. 1790–1793&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Davison, R.C.; Coleman, D.A.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The validity of power output recorded during exercise performance tests using a Kingcycle air-braked cycle ergometer when compared with an SRM powermeter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 21 (3), S. 195–199&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bassett, D.R.; Kyle, C. R.; Passfield, L.; Broker, J.P.; Burke, E.R. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Comparing cycling world hour records, 1967-1996: modeling with empirical data.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 31 (11), S. 1665–1676&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bentley, D. J.; McNaughton, L. R.; Thompson, D.; Vleck, V. E.; Batterham, A. M. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Peak power output, the lactate threshold, and time trial performance in cyclists. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 33 (12), S. 2077–2081&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Crequy, S.; Chiementin, X. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and Reliability of the G-Cog BMX Powermeter.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Bertucci, W.; Duc, S.; Villerius, V.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of the Axiom PowerTrain cycle ergometer when compared with an SRM powermeter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (1), S. 59–65&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Duc, S.; Villerius, V.; Pernin, J. N.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and reliability of the PowerTap mobile cycling powermeter when compared with the SRM Device.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (10), S. 868–873&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Grappe, F.; Girard, A.; Betik, A.; Rouillon, J.D. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects on the crank torque profile when changing pedalling cadence in level ground and uphill road cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Biomech 38 (5), S. 1003–1010&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Grappe, F.; Groslambert, A. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Laboratory versus outdoor cycling conditions: differences in pedaling biomechanics. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Biomech 23 (2), S. 87–92&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Taiar, R.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Differences between sprint tests under laboratory and actual cycling conditions. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Med Phys Fitness 45 (3), S. 277–283&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Billaut, François; Gore, Christopher J.; Aughey, Robert J. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Enhancing team-sport athlete performance: is altitude training relevant?&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 42 (9), S. 751–767&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Brickley, G.; Dekerle, J.; Hammond, A.; Pringle, J.; Carter, H. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Assessment of Maximal Aerobic Power and Critical Power in a Single 90-s Isokinetic All-Out Cycling Test.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 28 (5), S. 414–419&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Broker, J.P.; Kyle, C.R.; Burke, E.R. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Racing cyclist power requirements in the 4000-m individual and team pursuits.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 31 (11), S. 1677–1685&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Brosnan, M. J.; Martin, D. T.; Hahn, A. G.; Gore, C. J.; Hawley, J. A. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Impaired interval exercise responses in elite female cyclists at moderate simulated altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 89 (5), S. 1819–1824&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Cangley, P.; Passfield, L.; Carter, H.; Bailey, M. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The Effect of Variable Gradients on Pacing in Cycling Time-Trials.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 32 (02), S. 132–136&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Carpes, F.P.; Rossato, M.; Faria, I.E.; Bolli Mota, C. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Bilateral pedaling asymmetry during a simulated 40-km cycling timetrial.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Med Phys Fitness 47 (1), S. 51–57&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Clark, Sally A.; Bourdon, P. C.; Schmidt, W.; Singh, B.; Cable, G.; Onus, K. J. et al. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The effect of acute simulated moderate altitude on power, performance and pacing strategies in well-trained cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 102 (1), S. 45–55&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Clark, Sally A.; Quod, M. J.; Clark, M. A.; Martin, D. T.; Saunders, P. U.; Gore, C. J. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Time course of haemoglobin mass during 21 days live high:train low simulated altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 106 (3), S. 399–406&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Clark, S.K.; Johnson, Thomas M. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Selenium stable isotope investigation into selenium biogeochemical cycling in a lacustrine environment: Sweitzer Lake, Colorado.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Environ. Qual. 39 (6), S. 2200–2210&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Coleman, D.A.; Wiles, J.D.; Nunn, M.; Smith, M.F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reliability of sprint test indices in well-trained cyclists. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (5), S. 383–387&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Doherty, M.; Balmer, J.; Davison, R.C.R.; Robinson, L.; Smith, P.M. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reliability of a combined 3-min constant load and performance cycling test.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 24 (5), S. 366–371&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Duc, S.; Betik, A-C; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| EMG activity does not change during a time trial in competitive cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (2), S. 145–150&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Duc, S.; Villerius, V.; Bertucci, W.; Pernin, J.N.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Muscular activity level during pedalling is not affected by crank inertial load.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 95 (2-3), S. 260–264&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Duc, S.; Villerius, V.; Bertucci, W.; Grappe, F. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and reproducibility of the ErgomoPro power meter compared with the SRM and Powertap power meters.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 2 (3), S. 270–281&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Eastwood, A.; Sharpe, K.; Bourdon, P.C.; Woolford, S.M.; Saunders, P.U.; Robertson, E.Y. et al. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Within-subject variation in hemoglobin mass in elite athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 44 (4), S. 725–732&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Ebert, T.R.; Martin, D.T.; McDonald, W.; Victor, J.; Plummer, J.; Withers, R.T. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Power output during women's World Cup road cycle racing.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 95 (5-6), S. 529–536&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ebert, T.R.; Martin, D.T.; Stephens, B.; Withers, R.T. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Power output during a professional men's road-cycling tour.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 1 (4), S. 324–335&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Emonson, D. L.; Aminuddin, A. H.; Wight, R. L.; Scroop, G. C.; Gore, C. J. (1997)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Training-induced increases in sea level VO2max and endurance are not enhanced by acute hypobaric exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 76 (1), S. 8–12&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Faiss, R.; Praz, M.; Meichtry, A.; Gobelet, C.; Deriaz, O. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The effect of mountain bike suspensions on vibrations and off-road uphill performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Med Phys Fitness 47 (2), S. 151–158&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Fu, Qi; Townsend, N.E.; Shiller, S.M.; Martini, E.R.; Okazaki, K.; Shibata, S. et al. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Intermittent hypobaric hypoxia exposure does not cause sustained alterations in autonomic control of blood pressure in young athletes. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Am. J. Physiol. Regul. Integr. Comp. Physiol. 292 (5), S. R1977-84&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gardner, A.S.; Martin, J.C.; Martin, D.T.; Barras, M.; Jenkins, D.G. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Maximal torque- and power-pedaling rate relationships for elite sprint cyclists in laboratory and field tests. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 101 (3), S. 287–292&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gardner, A.S.; Martin, D.T.; Jenkins, D.G.; Dyer, I.; van Eiden, J.; Barras, M.; Martinm, J.C. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Velocity-specific fatigue: quantifying fatigue during variable velocity cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Med Sci Sports Exerc 41 (4), S. 904–911&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gardner, A.S.; Stephens, S.; Martin, D.T.; Lawton, E.; Lee, H.; Jenkins, D. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Accuracy of SRM and power tap power monitoring systems for bicycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 36 (7), S. 1252–1258&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Garvican, L.A.; Hammond, K.; Varley, Matthew C.; Gore, C.J.; Billaut, F.; Aughey, R.J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Lower Running Performance and Exacerbated Fatigue in Soccer Played at 1600 m. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Garvican, L.A.; Martin, D.T.; Clark, S.A.; Schmidt, W.F.; Gore, C.J. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Variability of erythropoietin response to sleeping at simulated altitude: a cycling case study. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 2 (3), S. 327–331.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Garvican, L.A.; Pottgiesser, T.; Martin, D.T.; Schumacher, Y.O.; Barras, M.; Gore, C.J. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The contribution of haemoglobin mass to increases in cycling performance induced by simulated LHTL. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 111 (6), S. 1089–1101&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Garvican, L.A.; Saunders, P.U.; Pyne, D.B.; Martin, D.T.; Robertson, E.Y.; Gore, C.J. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Hemoglobin mass response to simulated hypoxia &amp;quot;blinded&amp;quot; by noisy measurement? &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 112 (10), S. 1797-8; author reply 1799&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Giacomoni, M.; Billaut, F.; Falgairette, G. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effects of the Time of Day on Repeated All-Out Cycle Performance and Short-Term Recovery Patterns. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 27 (6), S. 468–474&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| González-Haro, C.; Galilea B., P.A.; Soria, M.; Drobnic, F.; Escanero, J.F. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Comparison of nine theoretical models for estimating the mechanical power output in cycling. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Br J Sports Med 41 (8), S. 506-9; discussion 509&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| González-Haro, C.; Galilea, P.A.; Escanero, J.F. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Comparison of different theoretical models estimating peak power output and maximal oxygen uptake in trained and elite triathletes and endurance cyclists in the velodrome. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Sci 26 (6), S. 591–601&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Goosey-Tolfrey, V.; Castle, P.; Webborn, N.; Abel, T. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Aerobic capacity and peak power output of elite quadriplegic games players.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Br J Sports Med 40 (8), S. 684–687&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gordon, R.S.; Franklin, K.L.; Davies, B.; Baker, J.S. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Further mechanical considerations between polar and SRM mobile ergometer systems during laboratory-based high-intensity, intermittent cycling activity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Res Sports Med 15 (4), S. 241–247&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, Christopher John; Clark, Sally A.; Saunders, Philo U. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Nonhematological mechanisms of improved sea-level performance after hypoxic exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 39 (9), S. 1600–1609&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A. G.; Aughey, R. J.; Martin, D. T.; Ashenden, M. J.; Clark, S. A. et al. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Live high:train low increases muscle buffer capacity and submaximal cycling efficiency.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Acta Physiol. Scand. 173 (3), S. 275–286&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A. G.; Burge, C. M.; Telford, R. D. (1997)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| VO2max and haemoglobin mass of trained athletes during high intensity training.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 18 (6), S. 477–482&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore C.J.; Hahn A.G.; Scroop G.C.; Watson D.B.; Norton K.I.; Wood R.J.; Campbell D.P. (1996 )&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Increased arterial desaturation in trained cyclists during maximal exercise at 580 m altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Physiol 80(6), S. 2204-10&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A.; Rice, A.; Bourdon, P.; Lawrence, S.; Walsh, C. et al. (1998)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Altitude training at 2690m does not increase total haemoglobin mass or sea level VO2max in world champion track cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 1 (3), S. 156–170&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A. G. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Letter to the editors - Re: Heinicke K, Heinicke I, Schmidt W, Wolfarth B. A three-week traditional altitude training increases hemoglobin mass and red cell volume in elite biathlon athletes. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (6), S. 504-5; author reply 506-7&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore C.J.; Little S.C.; Hahn A.G.; Scroop G.C.; Norton K.I.; Bourdon P.C.; Woolford (1997)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reduced performance of male and female athletes at 580 m altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 75(2), S. 136-43&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; McSharry, P. E.; Hewitt, A. J.; Saunders, P. U. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Preparation for football competition at moderate to high altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Scand J Med Sci Sports 18 Suppl 1, S. 85–95&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, Christopher J.; Rodríguez, Ferran A.; Truijens, Martin J.; Townsend, Nathan E.; Stray-Gundersen, James; Levine, Benjamin D. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Increased serum erythropoietin but not red cell production after 4 wk of intermittent hypobaric hypoxia (4,000-5,500 m).&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 101 (5), S. 1386–1393&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gough, C. E.; Sharpe, K.; Garvican, L. A.; Anson, J. M.; Saunders, P. U.; Gore, C. J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The effects of injury and illness on haemoglobin mass.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 34 (9), S. 763–769&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gough, C.E.; Saunders, P.U.; Fowlie, J.; Savage, B.; Pyne, D.B.; Anson, J.M. et al. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Influence of altitude training modality on performance and total haemoglobin mass in elite swimmers.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 112 (9), S. 3275–3285&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Groslambert, A.; Grappe, F.; Bertucci, W.; Perrey, S.; Girard, A.J.; Rouillon, J.D. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| A perceptive individual time trial performed by triathletes to estimate the anaerobic threshold. A preliminary study.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Med Phys Fitness 44 (2), S. 147–156&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Haakonssen, Eric C.; Martin, David T.; Burke, Louise M.; Jenkins, David G. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Energy expenditure of constant- and variable-intensity cycling: power meter estimates. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 45 (9), S. 1833–1840&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hahn, A. G.; Gore, C. J. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The effect of altitude on cycling performance: a challenge to traditional concepts. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 31 (7), S. 533–557&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hahn, A. G.; Gore, C. J.; Martin, D. T.; Ashenden, M. J.; Roberts, A. D.; Logan, P. A. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Hahn, A. G.; Gore, C. J.; Martin, D. T.; Ashenden, M. J.; Roberts, A. D.; Logan, P. A. (2001) &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Comp. Biochem. Physiol., Part A Mol. Integr. Physiol. 128 (4), S. 777–789&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hajoglou, A.; Foster, C.; Koning, J.J. de; Lucia, A.; Kernozek, T.W.; Porcari, J.P. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effect of warm-up on cycle time trial performance. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 37 (9), S. 1608–1614&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Hopker, J.; Myers, S.; Jobson, S.A.; Bruce, W.; Passfield, L. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of the Wattbike cycle ergometer&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 31 (10), S. 731–736&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Hurst, H.T.; Atkins, S. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Agreement between polar and SRM mobile ergometer systems during laboratory-based high-intensity, intermittent cycling activity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 24 (8), S. 863–868&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hurst, H.T.; Atkins, S. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Power output of field-based downhill mountain biking.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 24 (10), S. 1047–1053&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Davison, R.C.; Coleman, D.A.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The validity of power output recorded during exercise performance tests using a Kingcycle air-braked cycle ergometer when compared with an SRM powermeter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 21 (3), S. 195–199&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Jobson, S.A.; Passfield, L.; Atkinson, G.; Barton, G.; Scarf, P. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The analysis and utilization of cycling training data.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 39 (10), S. 833–844&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Jobson, S.; Woodside, J.; Passfield, L.; Nevill, A. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Allometric Scaling of Uphill Cycling Performance. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (09), S. 753–757&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Joch, W.; Ückert, S. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of Whole Body Cooling of - 110 °C on the Heart Frequency in Endurance Activity and in Resting Time. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| W. Phys Rehab Kur Med  14(3), S. 146-150&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Julian, Colleen G.; Gore, Christopher J.; Wilber, Randall L.; Daniels, Jack T.; Fredericson, Michael; Stray-Gundersen, James et al. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Intermittent normobaric hypoxia does not alter performance or erythropoietic markers in highly trained distance runners.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 96 (5), S. 1800–1807&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Karsten, B.; Jobson, S.A.; Hopker, J.; Passfield, L., Beedie, C. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The 3-min Test Does not Provide a Valid Measure of Critical Power Using the SRM Isokinetic Mode.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med. Sep 10. [Epub ahead of print]&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, T. A.; Gore, C. J.; Hahn, A. G.; Hopkins, W. G.; Hawley, J. A.; McKenna, M. J. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sleep in athletes undertaking protocols of exposure to nocturnal simulated altitude at 2650 m.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 8 (2), S. 222–232&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, T. A.; Hahn, A. G.; Gore, C. J.; Martin, D. T.; Chow, C. M. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sleep quality responses to atmospheric variation: case studies of two elite female cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 6 (4), S. 436–442&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, Tahnee A.; Hahn, Allan G.; Gore, Christopher J.; Wilsmore, Bradley R.; Martin, David T.; Chow, Chin-Moi (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Respiratory events and periodic breathing in cyclists sleeping at 2,650-m simulated altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 92 (5), S. 2114–2118&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, Tahnee A.; Townsend, Nathan E.; Gore, Christopher J.; Hahn, Allan G.; Clark, Sally A.; Aughey, Robert J. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sleep disturbance at simulated altitude indicated by stratified respiratory disturbance index but not hypoxic ventilatory response.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 94 (5-6), S. 569–575&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kirkland, A.; Coleman, D.; Wiles, J.D.; Hopker, J. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of the Ergomopro powermeter.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (11), S. 913–916&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Loughlin, A.F.; Skiles, G.L.; Alberts, D.W.; Schaefer, W.H. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| An ion exchange liquid chromatography/mass spectrometry method for the determination of reduced and oxidized glutathione and glutathione conjugates in hepatocytes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Pharm Biomed Anal 26 (1), S. 131–142&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|MacIntosh, B.R.; Svedahl, K.; Kim, M. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Fatigue and optimal conditions for short-term work capacity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 92 (4-5), S. 369–375&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|MacRae HS-H; Hise, K.J.; Allen, P.J. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of front and dual suspension mountain bike systems on uphill cycling performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 32 (7), S. 1276–1280&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Mc Naughton, L.R.; Sherman, R.; Roberts, S.; Bentley, D.J. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Portable gas analyser Cosmed K4b2 compared to a laboratory based mass spectrometer system.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Med Phys Fitness 45 (3), S. 315–323&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| McDaniel, J.; Subudhi, A.; Martin, J.C. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Torso stabilization reduces the metabolic cost of producing cycling power.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Can J Appl Physiol 30 (4), S. 433–441&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|McLean, Blake D.; Buttifant, David; Gore, Christopher J.; White, Kevin; Liess, Carsten; Kemp, Justin (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Physiological and performance responses to a preseason altitude-training camp in elite team-sport athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 8 (4), S. 391–399&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Meyer, T.; Gabriel, H.H.W.; Auracher, M.; Scharhag, J.; Kindermann, W. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Metabolic profile of 4 h cycling in the field with varying amounts of carbohydrate supply.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 88 (4-5), S. 431–437&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Mijnarends, D.M.; Meijers, J.M.M.; Halfens, R.J.G.; Ter Borg, S.; Luiking, Y.C.; Verlaan, S. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of tools to measure muscle mass, strength, and physical performance in community-dwelling older people: a systematic review.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Am Med Dir Assoc 14 (3), S. 170–178&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Millet, G.P.; Tronche, C.; Fuster, N.; Candau, R. (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Level ground and uphill cycling efficiency in seated and standing positions.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Med Sci Sports Exerc 34 (10), S. 1645–1652&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Millet, G.P.; Tronche, C.; Fuster, N.; Bentley, D.J.; Candau, R. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and reliability of the Polar S710 mobile cycling powermeter.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 24 (3), S. 156–161&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Mornieux, G.; Gollhofer, A.; Stapelfeldt, B. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Muscle Coordination while Pulling up During Cycling. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 31 (12), S. 843–846&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Mornieux, G.; Stapelfeldt, B.; Gollhofer, A.; Belli, A. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effects of Pedal Type and Pull-Up Action during Cycling. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (10), S. 817–822&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Neville, V.; Pain, M.T.G.; Folland, J.P. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Aerobic power and peak power of elite America's Cup sailors. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 106 (1), S. 149–157&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Neville, V.; Pain, M.T.G.; Kantor, J.; Folland, J.P. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Influence of crank length and crank-axle height on standing armcrank (grinding) power.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 42 (2), S. 381–387&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Neville, V.; Zaher, N.; Pain, M.T.G.; Folland, J.P. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Lower limb influence on standing arm-cranking ('grinding').&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 30 (10), S. 713–718&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Neya, Mitsuo; Enoki, Taisuke; Ohiwa, Nao; Kawahara, Takashi; Gore, Christopher J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Increased hemoglobin mass and VO2max with 10 h nightly simulated altitude at 3000 m.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 8 (4), S. 366–372&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Nimmerichter, A.; Eston, R.G.; Bachl, N.; Williams, C. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Longitudinal monitoring of power output and heart rate profiles in elite cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 29 (8), S. 831–840&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Nimmerichter, A.; Williams, C.; Bachl, N.; Eston, R. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Evaluation of a field test to assess performance in elite cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 31 (3), S. 160–166&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|O’Hara, J.; Thomas, A.; Seims, A.; Cooke, C.; King, R.F.G (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reliability of a High-Intensity Endurance Cycling Test.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 33 (01), S. 18–25&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Parisotto, R.; Gore, C. J.; Hahn, A. G.; Ashenden, M. J.; Olds, T. S.; Martin, D. T. et al. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reticulocyte parameters as potential discriminators of recombinant human erythropoietin abuse in elite athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 21 (7), S. 471–479&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Paton, C.D.; Hopkins, W.G. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Tests of cycling performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 31 (7), S. 489–496&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Paton, C.D.; Hopkins, W.G. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Ergometer error and biological variation in power output in a performance test with three cycle ergometers.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 27 (6), S. 444–447&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Caillaud, C.; Thompson, M.W. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Central and Peripheral Fatigue during Passive and Exercise-Induced Hyperthermia &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med. Sci. Sports Exerc. 43 (9), S. 1657 – 1665&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Caillaud, C.; Thompson, M.W. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The role of aerobic fitness and exercise intensity on endurance performance in uncompensable heat stress conditions. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol  112, S. 1989 - 1999&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Cramer, M.N.; Chapman, P.G.; Caillaud, C.; Thompson, M.W. (2011)  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Cardiovascular strain impairs prolonged self-paced exercise in the heat. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Exp Physiol 96 (2), S. 134 - 144&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Cramer, M.N.; Chapman, P.G.; Caillaud, C.; Thompson, M.W. (2011)   &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Neuromuscular function following prolonged intense self-paced exercise in hot climatic conditions. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Physiol. 111, S. 1561 – 1569&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Perrey, S.; Grappe, F.; Girard, A.; Bringard, A.; Groslambert, A.; Bertucci, W.; Rouillon, J.D. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Physiological and metabolic responses of triathletes to a simulated 30-min time-trial in cycling at self-selected intensity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 24 (2), S. 138–143&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Pester, M.; Knorr, K.-H.; Friedrich, M.W.; Wagner, M.; Loy, A. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sulfate-reducing microorganisms in wetlands - fameless actors in carbon cycling and climate change.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Front Microbiol 3, S. 72&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Pinot, J.; Grappe, F. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The record power profile to assess performance in elite cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 32 (11), S. 839–844&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Pottgiesser, Torben; Garvican, Laura A.; Martin, David T.; Featonby, Jesse M.; Gore, Christopher J.; Schumacher, Yorck O. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Short-term hematological effects upon completion of a four-week simulated altitude camp.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Physiol Perform 7 (1), S. 79–83&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Quod, M. J.; Martin, D. T.; Martin, J. C.; Laursen, P. B. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The Power Profile Predicts Road Cycling MMP.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 31 (06), S. 397–401&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Reiser, M.; Meyer, T.; Kindermann, W.; Daugs, R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Transferability of workload measurements between three different types of ergometer.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 82 (3), S. 245–249&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Reiser, R.; Hart, C. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Cycling on Rollers: Kreitler Fan Resistance at Submaximal Levels of Effort.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (3), S. 212–216&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Richalet, J-P; Gore, C. J. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Live and/or sleep high:train low, using normobaric hypoxia.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Scand J Med Sci Sports 18 Suppl 1, S. 29–37&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Roberts, A. D.; Clark, S. A.; Townsend, N. E.; Anderson, M. E.; Gore, C. J.; Hahn, A. G. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Changes in performance, maximal oxygen uptake and maximal accumulated oxygen deficit after 5, 10 and 15 days of live high:train low altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 88 (4-5), S. 390–395&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Robertson, E.Y.; Saunders, P.U.; Pyne, D.B.; Aughey, R.J.; Anson, J.M.; Gore, C.J. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reproducibility of performance changes to simulated live high/train low altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 42 (2), S. 394–401&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Robertson, E.Y.; Saunders, P.U.; Pyne, D.B.; Gore, C.J.; Anson, J.M. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effectiveness of intermittent training in hypoxia combined with live high/train low.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| . J. Appl. Physiol. 110 (2), S. 379–387&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Rodríguez, F.A.; Truijens, M.J.; Townsend, N.E.; Stray-Gundersen, J.; Gore, C.J.; Levine, B.D. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Performance of runners and swimmers after four weeks of intermittent hypobaric hypoxic exposure plus sea level training.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 103 (5), S. 1523–1535&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Sassi, A.; Rampinini, E.; Martin, D.T.; Morelli, A. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of gradient and speed on freely chosen cadence: the key role of crank inertial load.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Biomech 42 (2), S. 171–177&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P. U.; Telford, R. D.; Pyne, D. B.; Cunningham, R. B.; Gore, C. J.; Hahn, A. G.; Hawley, J. A. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Improved running economy in elite runners after 20 days of simulated moderate-altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 96 (3), S. 931–937&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P. U.; Telford, R. D.; Pyne, D. B.; Hahn, A. G.; Gore, C. J. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Improved running economy and increased hemoglobin mass in elite runners after extended moderate altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 12 (1), S. 67–72&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P.U.; Ahlgrim, C.; Vallance, B.; Green, D.J.; Robertson, E.Y.; Clark, S.A. et al. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| An attempt to quantify the placebo effect from a three-week simulated altitude training camp in elite race walkers.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 5 (4), S. 521–534&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P.U.; Pyne, David B.; Gore, C.J. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Endurance training at altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| High Alt. Med. Biol. 10 (2), S. 135–148&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P.U.; Telford, R.D.; Pyne, D.D.; Gore, C.J.; Hahn, A.G. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Improved race performance in elite middle-distance runners after cumulative altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 4 (1), S. 134–138&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Sharpe, K.; Hopkins, W.; Emslie, K.R.; Howe, C.; Trout, G.J.; Kazlauskas, R. et al. (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Development of reference ranges in elite athletes for markers of altered erythropoiesis.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Haematologica 87 (12), S. 1248–1257&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Simons, M.; van Es, E.; Hendriksen, I. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Electrically assisted cycling: a new mode for meeting physical activity guidelines?&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 41 (11), S. 2097–2102&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Smith, M.F.; Davison, R.C.; Balmer, J.; Bird, S.R. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reliability of mean power recorded during indoor and outdoor selfpaced 40 km cycling time-trials.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 22 (4), S. 270–274&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Stapelfeldt, B.; Mornieux, G.; Oberheim, R.; Belli, A.; Gollhofer, A. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Development and evaluation of a new bicycle instrument for measurements of pedal forces and power output in cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 28 (4), S. 326–332&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Stapelfeldt, B.; Schwirtz, A.; Schumacher, Y.O.; Hillebrecht, M. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Workload demands in mountain bike racing.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 25 (4), S. 294–300&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Tomas, A.; Ross, E.Z.; Martin, J.C. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Fatigue during maximal sprint cycling: unique role of cumulative contraction cycles.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 42 (7), S. 1364–1369&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Townsend, N.E.; Gore, C.J.; Hahn, A.G.; Aughey, R.J.; Clark, S.A.; Kinsman, T.A. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Hypoxic ventilatory response is correlated with increased submaximal exercise ventilation after live high, train low.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 94 (1-2), S. 207–215&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Townsend, N.E.; Gore, C.J.; Hahn, A.G.; McKenna, M.J.; Aughey, R.J.; Clark, S.A. et al. (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Living high-training low increases hypoxic ventilatory response of well-trained endurance athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 93 (4), S. 1498–1505&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Truijens, M.J.; Rodríguez, F.A.; Townsend, N.E.; Stray-Gundersen, J.; Gore, C.J.; Levine, B.D. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The effect of intermittent hypobaric hypoxic exposure and sea level training on submaximal economy in well-trained swimmers and runners.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 104 (2), S. 328–337&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Vaile, J.; Halson, S.; Gill, N.; Dawson, B. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effect of Hydrotherapy on Recovery from Fatigue.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 29 (7), S. 539–544&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| van der Woude, L.H.V.; Horstman, A.; Faas, P.; Mechielsen, S.; Bafghi, H.A.; Koning, J.J. de (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Power output and metabolic cost of synchronous and asynchronous submaximal and peak level hand cycling on a motor driven treadmill in able-bodied male subjects.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Med Eng Phys 30 (5), S. 574–580&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Villerius, V.; Duc, S.; Grappe, F. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Physiological and Neuromuscular Responses of Competitive Cyclists during a Simulated Self-Paced Interval Training Session.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (09), S. 770–777&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Vogt, S.; Heinrich, L.; Schumacher, Y. O.; Blum, A.; Roecker, K.; Dickhuth, H.-H.; Schmid, A. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Power output during stage racing in professional road cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 38 (1), S. 147–151&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Vogt, S.; Roecker, K.; Schumacher, Y. O.; Pottgiesser, T.; Dickhuth, H-H; Schmid, A.; Heinrich, L. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Cadence-power-relationship during decisive mountain ascents at the Tour de France.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 29 (3), S. 244–250&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Vogt, S.; Schumacher, Y.O.; Blum, A.; Roecker, K.; Dickhuth, H.-H.; Schmid, A.; Heinrich, L. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Cycling power output produced during flat and mountain stages in the Giro d'Italia: a case study.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Sci 25 (12), S. 1299–1305&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Vogt, S.; Schumacher, Y. O.; Roecker, K.; Dickhuth, H-H; Schoberer, U.; Schmid, A.; Heinrich, L. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Power Output during the Tour de France.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 28 (9), S. 756–761&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wahl, P.; Mathes, S.; Köhler, K.; Achtzehn, S.; Bloch, W.; Mester, J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Acute Metabolic, Hormonal, and Psychological Responses to Different Endurance Training Protocols.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Horm Metab Res 45 (11), S. 827–833&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wahl, P.; Schmidt, A.; deMarees, M.; Achtzehn, S.; Bloch, W.; Mester, J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Responses of Angiogenic Growth Factors to Exercise, to Hypoxia and to Exercise under Hypoxic Conditions.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 34 (02), S. 95–100&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wiedemann, M. S. F.; Bosquet, L. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Anaerobic Work Capacity Derived from Isokinetic and Isoinertial Cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 31 (02), S. 89–94&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wilson, M.G.; Lane, A.M.; Beedie, C.J.; Farooq, A. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Influence of accurate and inaccurate 'split-time' feedback upon 10-mile time trial cycling performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 112 (1), S. 231–236&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wooles, A.L.; Robinson, A.J.; Keen, P.S. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|A Static Method for Obtaining a Calibration Factor for SRM Bicycle Power Cranks.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sports Engineering 8 (3), S. 137-144&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=File:SRM_Scientific_Publications_05-2017.pdf&amp;diff=2057</id>
		<title>File:SRM Scientific Publications 05-2017.pdf</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=File:SRM_Scientific_Publications_05-2017.pdf&amp;diff=2057"/>
				<updated>2017-07-11T20:42:45Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Internationale_Literatur_zum_SRM-Ergometer&amp;diff=2056</id>
		<title>Internationale Literatur zum SRM-Ergometer</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Internationale_Literatur_zum_SRM-Ergometer&amp;diff=2056"/>
				<updated>2017-07-11T20:41:30Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{languages&lt;br /&gt;
|de=Internationale Literatur zum SRM-Ergometer&lt;br /&gt;
|en=International publications on the SRM Ergometer&lt;br /&gt;
|cn=International publications on the SRM Ergometer&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
In der folgenden Tabelle sind  diverese Sammlungen an Publikationen zu verschiedenen Themen als PDF-Dateien verlinkt.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot;&lt;br /&gt;
|+ style=&amp;quot;padding-bottom:1em&amp;quot; | Publikationen des SRM-Ergometers &lt;br /&gt;
|- class=&amp;quot;hintergrundfarbe6&amp;quot;&lt;br /&gt;
!style=&amp;quot;width:60%&amp;quot;| Publikationen!! style=&amp;quot;width:30%&amp;quot;| Letztes Update&lt;br /&gt;
|-&lt;br /&gt;
| [[Media:SRM_Scientific_Publications_05-2017.pdf|SRM Scientific Publications]]&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| Mai 2017 &lt;br /&gt;
|-&lt;br /&gt;
| [[Media:Torque_publications_2015.pdf|Torque Publications]]&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| Januar 2015&lt;br /&gt;
|-&lt;br /&gt;
| [[Media:Eccentric_Chainrings_2015.pdf|Eccentric Chainrings Publications]]&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| April 2015&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
(In der folgenden Tabelle finden Sie aktuelle internationale Literaturstellen in denen das SRM - Ergometer und / oder die SRM - Trainingssysteme für wissenschaftliche Untersuchungen eingesetzt wurden.&lt;br /&gt;
[[Media:SRM_Scientific_Publications_06-2016.pdf|Hier]] finden sie die internationalen Literaturstellen in einem pfd - Dokument zusammengefasst.)&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot;&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|- class=&amp;quot;hintergrundfarbe6&amp;quot;&lt;br /&gt;
!style=&amp;quot;width:30%&amp;quot;| Autor!! style=&amp;quot;width:30%&amp;quot; | Titel!! style=&amp;quot;width:30%&amp;quot; | Publikation&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Abbiss, C.R.; Quod, M.J.; Martin, David T.; Netto, K.J.; Nosaka, K.; Lee, H. et al. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Dynamic pacing strategies during the cycle phase of an Ironman triathlon.  &lt;br /&gt;
|style=&amp;quot;vertical-align:top&amp;quot;| Med Sci Sports Exerc 38 (4), S. 726–734&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Abbiss, C.R.; Quod, M.J.; Levin, G.; Martin, D.T.; Laursen, P.B. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Accuracy of the Velotron ergometer and SRM power meter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 30 (2), S. 107–112.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Abel, T.; Burkett, B.; Schneider, S.; Lindschulten, R.; Strüder, H. K. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The exercise profile of an ultra-long handcycling race: the Styrkeprøven experience.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Spinal Cord 48 (12), S. 894–898.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Antonutto, G.; Capelli, C.; Girardis, M.; Zamparo, P.; di Prampero P.E. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of microgravity on maximal power of lower limbs during very short efforts in humans.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Physiol 86(1), S. 85-92.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Arkesteijn, M.; Hopker, J.; Jobson, S.; Passfield, L. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The Effect of Turbo Trainer Cycling on Pedalling Technique and Cycling Efficiency.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 34 (06), S. 520–525&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M. J.; Gore, C. J.; Burge, C. M.; Clough, M. L.; Bourdon, P. C.; Dobson, G. P.; Hahn, A. G. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Skin-prick blood samples are reliable for estimating Hb mass with the CO-dilution technique.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 79 (6), S. 535–537.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M. J.; Gore, C. J.; Dobson, G. P.; Boston, T. T.; Parisotto, R.; Emslie, K. R. et al. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Simulated moderate altitude elevates serum erythropoietin but does not increase reticulocyte production in well-trained runners.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 81 (5), S. 428–435&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Gore, C. J.; Dobson, G. P.; Hahn, A. G. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| &amp;quot;Live high, train low&amp;quot; does not change the total haemoglobin mass of male endurance athletes sleeping at a simulated altitude of 3000 m for 23 nights. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 80 (5), S. 479–484.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Gore, C. J.; Martin, D. T.; Dobson, G. P.; Hahn, A. G. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of a 12-day &amp;quot;live high, train low&amp;quot; camp on reticulocyte production and haemoglobin mass in elite female road cyclists.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 80 (5), S. 472–478.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Hahn, A. G.; Martin, D. T.; Logan, P.; Parisotto, R.; Gore, C. J. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| A comparison of the physiological response to simulated altitude exposure and r-HuEpo administration.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 19 (11), S. 831–837&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Gore, C.J.; Parisotto, R.; Sharpe, K.; Hopkins, W.G.; Hahn, A.G. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effect of altitude on second-generation blood tests to detect erythropoietin abuse by athletes.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Haematologica 88 (9), S. 1053–1062&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Aughey, R. J.; Clark, S. A.; Gore, C. J.; Townsend, N. E.; Hahn, A. G.; Kinsman, T. A. et al. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Interspersed normoxia during live high, train low interventions reverses an early reduction in muscle Na+, K +ATPase activity in well-trained athletes.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 98 (3), S. 299–309&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Aughey, R. J.; Gore, C. J.; Hahn, A. G.; Garnham, A. P.; Clark, S. A.; Petersen, A. C. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Chronic intermittent hypoxia and incremental cycling exercise independently depress muscle in vitro maximal Na+-K+-ATPase activity in well-trained athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 98 (1), S. 186–192&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashman, S.B.; Monk, T.H.; Kupfer, D.J.; Clark, C.H.; Myers, F.S.; Frank, E.; Leibenluft (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Relationship between social rhythms and mood in patients with rapid cycling bipolar disorder.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Psychiatry Res 86 (1), S. 1–8&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Austin, N.; Nilwik, R.; Herzog, W. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| In vivo operational fascicle lengths of vastus lateralis during submaximal and maximal cycling.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Biomech 43 (12), S. 2394–2399&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Balmer, J.; Bird, S.; Davison, R.C.R.; Doherty, M.; Smith, P. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Mechanically braked Wingate powers: agreement between SRM, corrected and conventional methods of measurement.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 22 (7), S. 661–667&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Bird, S.; Davison, R.; Lucia, A. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effect of age on 16.1-km time-trial performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 26 (2), S. 197–206&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Davison, R.C.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Peak power predicts performance power during an outdoor 16.1-km cycling time trial.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 32 (8), S. 1485–1490&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Balmer, J.; Davison, R.C.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reliability of an air-braked ergometer to record peak power during a maximal cycling test.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 32 (10), S. 1790–1793&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Davison, R.C.; Coleman, D.A.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The validity of power output recorded during exercise performance tests using a Kingcycle air-braked cycle ergometer when compared with an SRM powermeter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 21 (3), S. 195–199&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bassett, D.R.; Kyle, C. R.; Passfield, L.; Broker, J.P.; Burke, E.R. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Comparing cycling world hour records, 1967-1996: modeling with empirical data.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 31 (11), S. 1665–1676&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bentley, D. J.; McNaughton, L. R.; Thompson, D.; Vleck, V. E.; Batterham, A. M. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Peak power output, the lactate threshold, and time trial performance in cyclists. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 33 (12), S. 2077–2081&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Crequy, S.; Chiementin, X. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and Reliability of the G-Cog BMX Powermeter.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Bertucci, W.; Duc, S.; Villerius, V.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of the Axiom PowerTrain cycle ergometer when compared with an SRM powermeter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (1), S. 59–65&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Duc, S.; Villerius, V.; Pernin, J. N.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and reliability of the PowerTap mobile cycling powermeter when compared with the SRM Device.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (10), S. 868–873&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Grappe, F.; Girard, A.; Betik, A.; Rouillon, J.D. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects on the crank torque profile when changing pedalling cadence in level ground and uphill road cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Biomech 38 (5), S. 1003–1010&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Grappe, F.; Groslambert, A. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Laboratory versus outdoor cycling conditions: differences in pedaling biomechanics. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Biomech 23 (2), S. 87–92&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Taiar, R.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Differences between sprint tests under laboratory and actual cycling conditions. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Med Phys Fitness 45 (3), S. 277–283&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Billaut, François; Gore, Christopher J.; Aughey, Robert J. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Enhancing team-sport athlete performance: is altitude training relevant?&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 42 (9), S. 751–767&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Brickley, G.; Dekerle, J.; Hammond, A.; Pringle, J.; Carter, H. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Assessment of Maximal Aerobic Power and Critical Power in a Single 90-s Isokinetic All-Out Cycling Test.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 28 (5), S. 414–419&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Broker, J.P.; Kyle, C.R.; Burke, E.R. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Racing cyclist power requirements in the 4000-m individual and team pursuits.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 31 (11), S. 1677–1685&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Brosnan, M. J.; Martin, D. T.; Hahn, A. G.; Gore, C. J.; Hawley, J. A. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Impaired interval exercise responses in elite female cyclists at moderate simulated altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 89 (5), S. 1819–1824&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Cangley, P.; Passfield, L.; Carter, H.; Bailey, M. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The Effect of Variable Gradients on Pacing in Cycling Time-Trials.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 32 (02), S. 132–136&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Carpes, F.P.; Rossato, M.; Faria, I.E.; Bolli Mota, C. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Bilateral pedaling asymmetry during a simulated 40-km cycling timetrial.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Med Phys Fitness 47 (1), S. 51–57&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Clark, Sally A.; Bourdon, P. C.; Schmidt, W.; Singh, B.; Cable, G.; Onus, K. J. et al. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The effect of acute simulated moderate altitude on power, performance and pacing strategies in well-trained cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 102 (1), S. 45–55&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Clark, Sally A.; Quod, M. J.; Clark, M. A.; Martin, D. T.; Saunders, P. U.; Gore, C. J. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Time course of haemoglobin mass during 21 days live high:train low simulated altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 106 (3), S. 399–406&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Clark, S.K.; Johnson, Thomas M. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Selenium stable isotope investigation into selenium biogeochemical cycling in a lacustrine environment: Sweitzer Lake, Colorado.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Environ. Qual. 39 (6), S. 2200–2210&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Coleman, D.A.; Wiles, J.D.; Nunn, M.; Smith, M.F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reliability of sprint test indices in well-trained cyclists. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (5), S. 383–387&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Doherty, M.; Balmer, J.; Davison, R.C.R.; Robinson, L.; Smith, P.M. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reliability of a combined 3-min constant load and performance cycling test.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 24 (5), S. 366–371&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Duc, S.; Betik, A-C; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| EMG activity does not change during a time trial in competitive cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (2), S. 145–150&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Duc, S.; Villerius, V.; Bertucci, W.; Pernin, J.N.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Muscular activity level during pedalling is not affected by crank inertial load.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 95 (2-3), S. 260–264&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Duc, S.; Villerius, V.; Bertucci, W.; Grappe, F. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and reproducibility of the ErgomoPro power meter compared with the SRM and Powertap power meters.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 2 (3), S. 270–281&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Eastwood, A.; Sharpe, K.; Bourdon, P.C.; Woolford, S.M.; Saunders, P.U.; Robertson, E.Y. et al. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Within-subject variation in hemoglobin mass in elite athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 44 (4), S. 725–732&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Ebert, T.R.; Martin, D.T.; McDonald, W.; Victor, J.; Plummer, J.; Withers, R.T. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Power output during women's World Cup road cycle racing.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 95 (5-6), S. 529–536&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ebert, T.R.; Martin, D.T.; Stephens, B.; Withers, R.T. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Power output during a professional men's road-cycling tour.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 1 (4), S. 324–335&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Emonson, D. L.; Aminuddin, A. H.; Wight, R. L.; Scroop, G. C.; Gore, C. J. (1997)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Training-induced increases in sea level VO2max and endurance are not enhanced by acute hypobaric exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 76 (1), S. 8–12&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Faiss, R.; Praz, M.; Meichtry, A.; Gobelet, C.; Deriaz, O. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The effect of mountain bike suspensions on vibrations and off-road uphill performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Med Phys Fitness 47 (2), S. 151–158&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Fu, Qi; Townsend, N.E.; Shiller, S.M.; Martini, E.R.; Okazaki, K.; Shibata, S. et al. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Intermittent hypobaric hypoxia exposure does not cause sustained alterations in autonomic control of blood pressure in young athletes. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Am. J. Physiol. Regul. Integr. Comp. Physiol. 292 (5), S. R1977-84&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gardner, A.S.; Martin, J.C.; Martin, D.T.; Barras, M.; Jenkins, D.G. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Maximal torque- and power-pedaling rate relationships for elite sprint cyclists in laboratory and field tests. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 101 (3), S. 287–292&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gardner, A.S.; Martin, D.T.; Jenkins, D.G.; Dyer, I.; van Eiden, J.; Barras, M.; Martinm, J.C. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Velocity-specific fatigue: quantifying fatigue during variable velocity cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Med Sci Sports Exerc 41 (4), S. 904–911&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gardner, A.S.; Stephens, S.; Martin, D.T.; Lawton, E.; Lee, H.; Jenkins, D. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Accuracy of SRM and power tap power monitoring systems for bicycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 36 (7), S. 1252–1258&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Garvican, L.A.; Hammond, K.; Varley, Matthew C.; Gore, C.J.; Billaut, F.; Aughey, R.J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Lower Running Performance and Exacerbated Fatigue in Soccer Played at 1600 m. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Garvican, L.A.; Martin, D.T.; Clark, S.A.; Schmidt, W.F.; Gore, C.J. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Variability of erythropoietin response to sleeping at simulated altitude: a cycling case study. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 2 (3), S. 327–331.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Garvican, L.A.; Pottgiesser, T.; Martin, D.T.; Schumacher, Y.O.; Barras, M.; Gore, C.J. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The contribution of haemoglobin mass to increases in cycling performance induced by simulated LHTL. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 111 (6), S. 1089–1101&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Garvican, L.A.; Saunders, P.U.; Pyne, D.B.; Martin, D.T.; Robertson, E.Y.; Gore, C.J. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Hemoglobin mass response to simulated hypoxia &amp;quot;blinded&amp;quot; by noisy measurement? &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 112 (10), S. 1797-8; author reply 1799&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Giacomoni, M.; Billaut, F.; Falgairette, G. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effects of the Time of Day on Repeated All-Out Cycle Performance and Short-Term Recovery Patterns. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 27 (6), S. 468–474&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| González-Haro, C.; Galilea B., P.A.; Soria, M.; Drobnic, F.; Escanero, J.F. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Comparison of nine theoretical models for estimating the mechanical power output in cycling. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Br J Sports Med 41 (8), S. 506-9; discussion 509&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| González-Haro, C.; Galilea, P.A.; Escanero, J.F. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Comparison of different theoretical models estimating peak power output and maximal oxygen uptake in trained and elite triathletes and endurance cyclists in the velodrome. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Sci 26 (6), S. 591–601&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Goosey-Tolfrey, V.; Castle, P.; Webborn, N.; Abel, T. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Aerobic capacity and peak power output of elite quadriplegic games players.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Br J Sports Med 40 (8), S. 684–687&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gordon, R.S.; Franklin, K.L.; Davies, B.; Baker, J.S. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Further mechanical considerations between polar and SRM mobile ergometer systems during laboratory-based high-intensity, intermittent cycling activity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Res Sports Med 15 (4), S. 241–247&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, Christopher John; Clark, Sally A.; Saunders, Philo U. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Nonhematological mechanisms of improved sea-level performance after hypoxic exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 39 (9), S. 1600–1609&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A. G.; Aughey, R. J.; Martin, D. T.; Ashenden, M. J.; Clark, S. A. et al. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Live high:train low increases muscle buffer capacity and submaximal cycling efficiency.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Acta Physiol. Scand. 173 (3), S. 275–286&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A. G.; Burge, C. M.; Telford, R. D. (1997)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| VO2max and haemoglobin mass of trained athletes during high intensity training.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 18 (6), S. 477–482&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore C.J.; Hahn A.G.; Scroop G.C.; Watson D.B.; Norton K.I.; Wood R.J.; Campbell D.P. (1996 )&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Increased arterial desaturation in trained cyclists during maximal exercise at 580 m altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Physiol 80(6), S. 2204-10&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A.; Rice, A.; Bourdon, P.; Lawrence, S.; Walsh, C. et al. (1998)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Altitude training at 2690m does not increase total haemoglobin mass or sea level VO2max in world champion track cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 1 (3), S. 156–170&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A. G. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Letter to the editors - Re: Heinicke K, Heinicke I, Schmidt W, Wolfarth B. A three-week traditional altitude training increases hemoglobin mass and red cell volume in elite biathlon athletes. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (6), S. 504-5; author reply 506-7&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore C.J.; Little S.C.; Hahn A.G.; Scroop G.C.; Norton K.I.; Bourdon P.C.; Woolford (1997)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reduced performance of male and female athletes at 580 m altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 75(2), S. 136-43&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; McSharry, P. E.; Hewitt, A. J.; Saunders, P. U. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Preparation for football competition at moderate to high altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Scand J Med Sci Sports 18 Suppl 1, S. 85–95&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, Christopher J.; Rodríguez, Ferran A.; Truijens, Martin J.; Townsend, Nathan E.; Stray-Gundersen, James; Levine, Benjamin D. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Increased serum erythropoietin but not red cell production after 4 wk of intermittent hypobaric hypoxia (4,000-5,500 m).&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 101 (5), S. 1386–1393&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gough, C. E.; Sharpe, K.; Garvican, L. A.; Anson, J. M.; Saunders, P. U.; Gore, C. J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The effects of injury and illness on haemoglobin mass.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 34 (9), S. 763–769&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gough, C.E.; Saunders, P.U.; Fowlie, J.; Savage, B.; Pyne, D.B.; Anson, J.M. et al. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Influence of altitude training modality on performance and total haemoglobin mass in elite swimmers.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 112 (9), S. 3275–3285&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Groslambert, A.; Grappe, F.; Bertucci, W.; Perrey, S.; Girard, A.J.; Rouillon, J.D. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| A perceptive individual time trial performed by triathletes to estimate the anaerobic threshold. A preliminary study.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Med Phys Fitness 44 (2), S. 147–156&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Haakonssen, Eric C.; Martin, David T.; Burke, Louise M.; Jenkins, David G. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Energy expenditure of constant- and variable-intensity cycling: power meter estimates. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 45 (9), S. 1833–1840&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hahn, A. G.; Gore, C. J. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The effect of altitude on cycling performance: a challenge to traditional concepts. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 31 (7), S. 533–557&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hahn, A. G.; Gore, C. J.; Martin, D. T.; Ashenden, M. J.; Roberts, A. D.; Logan, P. A. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Hahn, A. G.; Gore, C. J.; Martin, D. T.; Ashenden, M. J.; Roberts, A. D.; Logan, P. A. (2001) &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Comp. Biochem. Physiol., Part A Mol. Integr. Physiol. 128 (4), S. 777–789&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hajoglou, A.; Foster, C.; Koning, J.J. de; Lucia, A.; Kernozek, T.W.; Porcari, J.P. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effect of warm-up on cycle time trial performance. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 37 (9), S. 1608–1614&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Hopker, J.; Myers, S.; Jobson, S.A.; Bruce, W.; Passfield, L. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of the Wattbike cycle ergometer&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 31 (10), S. 731–736&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Hurst, H.T.; Atkins, S. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Agreement between polar and SRM mobile ergometer systems during laboratory-based high-intensity, intermittent cycling activity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 24 (8), S. 863–868&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hurst, H.T.; Atkins, S. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Power output of field-based downhill mountain biking.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 24 (10), S. 1047–1053&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Davison, R.C.; Coleman, D.A.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The validity of power output recorded during exercise performance tests using a Kingcycle air-braked cycle ergometer when compared with an SRM powermeter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 21 (3), S. 195–199&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Jobson, S.A.; Passfield, L.; Atkinson, G.; Barton, G.; Scarf, P. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The analysis and utilization of cycling training data.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 39 (10), S. 833–844&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Jobson, S.; Woodside, J.; Passfield, L.; Nevill, A. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Allometric Scaling of Uphill Cycling Performance. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (09), S. 753–757&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Joch, W.; Ückert, S. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of Whole Body Cooling of - 110 °C on the Heart Frequency in Endurance Activity and in Resting Time. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| W. Phys Rehab Kur Med  14(3), S. 146-150&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Julian, Colleen G.; Gore, Christopher J.; Wilber, Randall L.; Daniels, Jack T.; Fredericson, Michael; Stray-Gundersen, James et al. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Intermittent normobaric hypoxia does not alter performance or erythropoietic markers in highly trained distance runners.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 96 (5), S. 1800–1807&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Karsten, B.; Jobson, S.A.; Hopker, J.; Passfield, L., Beedie, C. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The 3-min Test Does not Provide a Valid Measure of Critical Power Using the SRM Isokinetic Mode.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med. Sep 10. [Epub ahead of print]&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, T. A.; Gore, C. J.; Hahn, A. G.; Hopkins, W. G.; Hawley, J. A.; McKenna, M. J. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sleep in athletes undertaking protocols of exposure to nocturnal simulated altitude at 2650 m.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 8 (2), S. 222–232&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, T. A.; Hahn, A. G.; Gore, C. J.; Martin, D. T.; Chow, C. M. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sleep quality responses to atmospheric variation: case studies of two elite female cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 6 (4), S. 436–442&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, Tahnee A.; Hahn, Allan G.; Gore, Christopher J.; Wilsmore, Bradley R.; Martin, David T.; Chow, Chin-Moi (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Respiratory events and periodic breathing in cyclists sleeping at 2,650-m simulated altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 92 (5), S. 2114–2118&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, Tahnee A.; Townsend, Nathan E.; Gore, Christopher J.; Hahn, Allan G.; Clark, Sally A.; Aughey, Robert J. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sleep disturbance at simulated altitude indicated by stratified respiratory disturbance index but not hypoxic ventilatory response.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 94 (5-6), S. 569–575&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kirkland, A.; Coleman, D.; Wiles, J.D.; Hopker, J. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of the Ergomopro powermeter.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (11), S. 913–916&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Loughlin, A.F.; Skiles, G.L.; Alberts, D.W.; Schaefer, W.H. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| An ion exchange liquid chromatography/mass spectrometry method for the determination of reduced and oxidized glutathione and glutathione conjugates in hepatocytes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Pharm Biomed Anal 26 (1), S. 131–142&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|MacIntosh, B.R.; Svedahl, K.; Kim, M. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Fatigue and optimal conditions for short-term work capacity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 92 (4-5), S. 369–375&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|MacRae HS-H; Hise, K.J.; Allen, P.J. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of front and dual suspension mountain bike systems on uphill cycling performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 32 (7), S. 1276–1280&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Mc Naughton, L.R.; Sherman, R.; Roberts, S.; Bentley, D.J. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Portable gas analyser Cosmed K4b2 compared to a laboratory based mass spectrometer system.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Med Phys Fitness 45 (3), S. 315–323&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| McDaniel, J.; Subudhi, A.; Martin, J.C. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Torso stabilization reduces the metabolic cost of producing cycling power.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Can J Appl Physiol 30 (4), S. 433–441&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|McLean, Blake D.; Buttifant, David; Gore, Christopher J.; White, Kevin; Liess, Carsten; Kemp, Justin (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Physiological and performance responses to a preseason altitude-training camp in elite team-sport athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 8 (4), S. 391–399&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Meyer, T.; Gabriel, H.H.W.; Auracher, M.; Scharhag, J.; Kindermann, W. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Metabolic profile of 4 h cycling in the field with varying amounts of carbohydrate supply.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 88 (4-5), S. 431–437&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Mijnarends, D.M.; Meijers, J.M.M.; Halfens, R.J.G.; Ter Borg, S.; Luiking, Y.C.; Verlaan, S. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of tools to measure muscle mass, strength, and physical performance in community-dwelling older people: a systematic review.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Am Med Dir Assoc 14 (3), S. 170–178&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Millet, G.P.; Tronche, C.; Fuster, N.; Candau, R. (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Level ground and uphill cycling efficiency in seated and standing positions.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Med Sci Sports Exerc 34 (10), S. 1645–1652&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Millet, G.P.; Tronche, C.; Fuster, N.; Bentley, D.J.; Candau, R. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and reliability of the Polar S710 mobile cycling powermeter.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 24 (3), S. 156–161&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Mornieux, G.; Gollhofer, A.; Stapelfeldt, B. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Muscle Coordination while Pulling up During Cycling. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 31 (12), S. 843–846&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Mornieux, G.; Stapelfeldt, B.; Gollhofer, A.; Belli, A. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effects of Pedal Type and Pull-Up Action during Cycling. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (10), S. 817–822&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Neville, V.; Pain, M.T.G.; Folland, J.P. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Aerobic power and peak power of elite America's Cup sailors. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 106 (1), S. 149–157&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Neville, V.; Pain, M.T.G.; Kantor, J.; Folland, J.P. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Influence of crank length and crank-axle height on standing armcrank (grinding) power.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 42 (2), S. 381–387&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Neville, V.; Zaher, N.; Pain, M.T.G.; Folland, J.P. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Lower limb influence on standing arm-cranking ('grinding').&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 30 (10), S. 713–718&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Neya, Mitsuo; Enoki, Taisuke; Ohiwa, Nao; Kawahara, Takashi; Gore, Christopher J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Increased hemoglobin mass and VO2max with 10 h nightly simulated altitude at 3000 m.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 8 (4), S. 366–372&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Nimmerichter, A.; Eston, R.G.; Bachl, N.; Williams, C. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Longitudinal monitoring of power output and heart rate profiles in elite cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 29 (8), S. 831–840&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Nimmerichter, A.; Williams, C.; Bachl, N.; Eston, R. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Evaluation of a field test to assess performance in elite cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 31 (3), S. 160–166&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|O’Hara, J.; Thomas, A.; Seims, A.; Cooke, C.; King, R.F.G (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reliability of a High-Intensity Endurance Cycling Test.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 33 (01), S. 18–25&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Parisotto, R.; Gore, C. J.; Hahn, A. G.; Ashenden, M. J.; Olds, T. S.; Martin, D. T. et al. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reticulocyte parameters as potential discriminators of recombinant human erythropoietin abuse in elite athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 21 (7), S. 471–479&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Paton, C.D.; Hopkins, W.G. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Tests of cycling performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 31 (7), S. 489–496&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Paton, C.D.; Hopkins, W.G. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Ergometer error and biological variation in power output in a performance test with three cycle ergometers.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 27 (6), S. 444–447&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Caillaud, C.; Thompson, M.W. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Central and Peripheral Fatigue during Passive and Exercise-Induced Hyperthermia &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med. Sci. Sports Exerc. 43 (9), S. 1657 – 1665&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Caillaud, C.; Thompson, M.W. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The role of aerobic fitness and exercise intensity on endurance performance in uncompensable heat stress conditions. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol  112, S. 1989 - 1999&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Cramer, M.N.; Chapman, P.G.; Caillaud, C.; Thompson, M.W. (2011)  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Cardiovascular strain impairs prolonged self-paced exercise in the heat. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Exp Physiol 96 (2), S. 134 - 144&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Cramer, M.N.; Chapman, P.G.; Caillaud, C.; Thompson, M.W. (2011)   &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Neuromuscular function following prolonged intense self-paced exercise in hot climatic conditions. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Physiol. 111, S. 1561 – 1569&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Perrey, S.; Grappe, F.; Girard, A.; Bringard, A.; Groslambert, A.; Bertucci, W.; Rouillon, J.D. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Physiological and metabolic responses of triathletes to a simulated 30-min time-trial in cycling at self-selected intensity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 24 (2), S. 138–143&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Pester, M.; Knorr, K.-H.; Friedrich, M.W.; Wagner, M.; Loy, A. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sulfate-reducing microorganisms in wetlands - fameless actors in carbon cycling and climate change.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Front Microbiol 3, S. 72&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Pinot, J.; Grappe, F. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The record power profile to assess performance in elite cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 32 (11), S. 839–844&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Pottgiesser, Torben; Garvican, Laura A.; Martin, David T.; Featonby, Jesse M.; Gore, Christopher J.; Schumacher, Yorck O. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Short-term hematological effects upon completion of a four-week simulated altitude camp.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Physiol Perform 7 (1), S. 79–83&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Quod, M. J.; Martin, D. T.; Martin, J. C.; Laursen, P. B. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The Power Profile Predicts Road Cycling MMP.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 31 (06), S. 397–401&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Reiser, M.; Meyer, T.; Kindermann, W.; Daugs, R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Transferability of workload measurements between three different types of ergometer.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 82 (3), S. 245–249&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Reiser, R.; Hart, C. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Cycling on Rollers: Kreitler Fan Resistance at Submaximal Levels of Effort.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (3), S. 212–216&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Richalet, J-P; Gore, C. J. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Live and/or sleep high:train low, using normobaric hypoxia.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Scand J Med Sci Sports 18 Suppl 1, S. 29–37&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Roberts, A. D.; Clark, S. A.; Townsend, N. E.; Anderson, M. E.; Gore, C. J.; Hahn, A. G. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Changes in performance, maximal oxygen uptake and maximal accumulated oxygen deficit after 5, 10 and 15 days of live high:train low altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 88 (4-5), S. 390–395&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Robertson, E.Y.; Saunders, P.U.; Pyne, D.B.; Aughey, R.J.; Anson, J.M.; Gore, C.J. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reproducibility of performance changes to simulated live high/train low altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 42 (2), S. 394–401&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Robertson, E.Y.; Saunders, P.U.; Pyne, D.B.; Gore, C.J.; Anson, J.M. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effectiveness of intermittent training in hypoxia combined with live high/train low.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| . J. Appl. Physiol. 110 (2), S. 379–387&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Rodríguez, F.A.; Truijens, M.J.; Townsend, N.E.; Stray-Gundersen, J.; Gore, C.J.; Levine, B.D. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Performance of runners and swimmers after four weeks of intermittent hypobaric hypoxic exposure plus sea level training.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 103 (5), S. 1523–1535&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Sassi, A.; Rampinini, E.; Martin, D.T.; Morelli, A. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of gradient and speed on freely chosen cadence: the key role of crank inertial load.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Biomech 42 (2), S. 171–177&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P. U.; Telford, R. D.; Pyne, D. B.; Cunningham, R. B.; Gore, C. J.; Hahn, A. G.; Hawley, J. A. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Improved running economy in elite runners after 20 days of simulated moderate-altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 96 (3), S. 931–937&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P. U.; Telford, R. D.; Pyne, D. B.; Hahn, A. G.; Gore, C. J. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Improved running economy and increased hemoglobin mass in elite runners after extended moderate altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 12 (1), S. 67–72&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P.U.; Ahlgrim, C.; Vallance, B.; Green, D.J.; Robertson, E.Y.; Clark, S.A. et al. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| An attempt to quantify the placebo effect from a three-week simulated altitude training camp in elite race walkers.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 5 (4), S. 521–534&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P.U.; Pyne, David B.; Gore, C.J. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Endurance training at altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| High Alt. Med. Biol. 10 (2), S. 135–148&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P.U.; Telford, R.D.; Pyne, D.D.; Gore, C.J.; Hahn, A.G. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Improved race performance in elite middle-distance runners after cumulative altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 4 (1), S. 134–138&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Sharpe, K.; Hopkins, W.; Emslie, K.R.; Howe, C.; Trout, G.J.; Kazlauskas, R. et al. (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Development of reference ranges in elite athletes for markers of altered erythropoiesis.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Haematologica 87 (12), S. 1248–1257&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Simons, M.; van Es, E.; Hendriksen, I. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Electrically assisted cycling: a new mode for meeting physical activity guidelines?&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 41 (11), S. 2097–2102&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Smith, M.F.; Davison, R.C.; Balmer, J.; Bird, S.R. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reliability of mean power recorded during indoor and outdoor selfpaced 40 km cycling time-trials.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 22 (4), S. 270–274&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Stapelfeldt, B.; Mornieux, G.; Oberheim, R.; Belli, A.; Gollhofer, A. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Development and evaluation of a new bicycle instrument for measurements of pedal forces and power output in cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 28 (4), S. 326–332&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Stapelfeldt, B.; Schwirtz, A.; Schumacher, Y.O.; Hillebrecht, M. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Workload demands in mountain bike racing.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 25 (4), S. 294–300&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Tomas, A.; Ross, E.Z.; Martin, J.C. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Fatigue during maximal sprint cycling: unique role of cumulative contraction cycles.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 42 (7), S. 1364–1369&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Townsend, N.E.; Gore, C.J.; Hahn, A.G.; Aughey, R.J.; Clark, S.A.; Kinsman, T.A. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Hypoxic ventilatory response is correlated with increased submaximal exercise ventilation after live high, train low.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 94 (1-2), S. 207–215&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Townsend, N.E.; Gore, C.J.; Hahn, A.G.; McKenna, M.J.; Aughey, R.J.; Clark, S.A. et al. (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Living high-training low increases hypoxic ventilatory response of well-trained endurance athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 93 (4), S. 1498–1505&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Truijens, M.J.; Rodríguez, F.A.; Townsend, N.E.; Stray-Gundersen, J.; Gore, C.J.; Levine, B.D. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The effect of intermittent hypobaric hypoxic exposure and sea level training on submaximal economy in well-trained swimmers and runners.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 104 (2), S. 328–337&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Vaile, J.; Halson, S.; Gill, N.; Dawson, B. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effect of Hydrotherapy on Recovery from Fatigue.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 29 (7), S. 539–544&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| van der Woude, L.H.V.; Horstman, A.; Faas, P.; Mechielsen, S.; Bafghi, H.A.; Koning, J.J. de (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Power output and metabolic cost of synchronous and asynchronous submaximal and peak level hand cycling on a motor driven treadmill in able-bodied male subjects.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Med Eng Phys 30 (5), S. 574–580&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Villerius, V.; Duc, S.; Grappe, F. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Physiological and Neuromuscular Responses of Competitive Cyclists during a Simulated Self-Paced Interval Training Session.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (09), S. 770–777&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Vogt, S.; Heinrich, L.; Schumacher, Y. O.; Blum, A.; Roecker, K.; Dickhuth, H.-H.; Schmid, A. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Power output during stage racing in professional road cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 38 (1), S. 147–151&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Vogt, S.; Roecker, K.; Schumacher, Y. O.; Pottgiesser, T.; Dickhuth, H-H; Schmid, A.; Heinrich, L. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Cadence-power-relationship during decisive mountain ascents at the Tour de France.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 29 (3), S. 244–250&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Vogt, S.; Schumacher, Y.O.; Blum, A.; Roecker, K.; Dickhuth, H.-H.; Schmid, A.; Heinrich, L. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Cycling power output produced during flat and mountain stages in the Giro d'Italia: a case study.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Sci 25 (12), S. 1299–1305&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Vogt, S.; Schumacher, Y. O.; Roecker, K.; Dickhuth, H-H; Schoberer, U.; Schmid, A.; Heinrich, L. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Power Output during the Tour de France.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 28 (9), S. 756–761&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wahl, P.; Mathes, S.; Köhler, K.; Achtzehn, S.; Bloch, W.; Mester, J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Acute Metabolic, Hormonal, and Psychological Responses to Different Endurance Training Protocols.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Horm Metab Res 45 (11), S. 827–833&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wahl, P.; Schmidt, A.; deMarees, M.; Achtzehn, S.; Bloch, W.; Mester, J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Responses of Angiogenic Growth Factors to Exercise, to Hypoxia and to Exercise under Hypoxic Conditions.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 34 (02), S. 95–100&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wiedemann, M. S. F.; Bosquet, L. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Anaerobic Work Capacity Derived from Isokinetic and Isoinertial Cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 31 (02), S. 89–94&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wilson, M.G.; Lane, A.M.; Beedie, C.J.; Farooq, A. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Influence of accurate and inaccurate 'split-time' feedback upon 10-mile time trial cycling performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 112 (1), S. 231–236&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wooles, A.L.; Robinson, A.J.; Keen, P.S. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|A Static Method for Obtaining a Calibration Factor for SRM Bicycle Power Cranks.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sports Engineering 8 (3), S. 137-144&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=FAQ%27s&amp;diff=2055</id>
		<title>FAQ's</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=FAQ%27s&amp;diff=2055"/>
				<updated>2017-04-23T11:15:58Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{languages&lt;br /&gt;
|de=FAQ's&lt;br /&gt;
|en=FAQs&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
==Lichtschranke==&lt;br /&gt;
&lt;br /&gt;
Die Lichtschranke misst an der so genannten Unterbrecherscheibe die Geschwindigkeit (Speed) der Schwungmassen. Sie ist für die Berechnung der Leitung obligatorisch. Wird Speed nicht korrekt gemessen kann die Leistung nicht berechnet werden. Die angezeigten Speedwerte in der SRMWin-Software - z.B. während eines Leistungstests - entsprechen keinen realen Geschwindigkeitswerten.&lt;br /&gt;
&lt;br /&gt;
In den folgenden Abbildungen ist die Position der Lichtschranke im Getriebe zu erkennen. Um die Lichtschranke zu reinigen oder Ihre Position zu verändern müssen die Schwungmassen abgenommen werden.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
 File:Isokinetischer_Test_2.jpg|Speed Anzeige während eines Testes (hier 31,3 km/h)&lt;br /&gt;
 File:00-Lichtschranke-ort.jpg|Abnehmen der Schwungscheiben&lt;br /&gt;
 File:01-Lichtschranke-ort.jpg|Position des Lichtschranke&lt;br /&gt;
 File:02-Lichtschranke-ort.jpg|Position der Lichtschranke an der Unterbrecherscheibe (offen)&lt;br /&gt;
 File:03-Lichtschranke-ort.jpg|Position der Lichtschranke an der Unterbrecherscheibe (geschlossen)&lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Netzteil / Powersupply ==&lt;br /&gt;
&lt;br /&gt;
[[File:SRM-PowerSupply-01.jpg|thumb|Powersupply mit leuchtender grüner Lampe]]&lt;br /&gt;
&lt;br /&gt;
* '''Grüne Lampe leuchtet nicht'''&lt;br /&gt;
&lt;br /&gt;
: Leuchtet die grüne Lampe nach dem Einschalten nicht, ist das Netzteil defekt. Bitte schicken Sie es an SRM zum Service ein.&lt;br /&gt;
&lt;br /&gt;
* '''Orange Lampe leuchtet nicht kurz auf'''&lt;br /&gt;
&lt;br /&gt;
: Beim Einschalten des Netzteils sollte die orangene Lampe kurz aufleuchten. Ist dieses nicht der Fall sind evtl. Sicherungen durchgebrannt. Schicken Sie es dann bitte an SRM zum Service ein.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Sattelstütze ==&lt;br /&gt;
&lt;br /&gt;
[[File:SRM-Sattelstütze-(Bezeichnungen).jpg|thumb|Bezeichnungen der Sattelstütze]]&lt;br /&gt;
&lt;br /&gt;
Die Bezeichnungen der Sattelstütze finden Sie auf dem angehängten Foto. Falls Sie Ersatzteile der Sattelstütze benötigen, lassen Sie uns bitte die korrekten Bezeichnungen inkl. des Baujahrs des SRM - Ergometers zukommen.&lt;br /&gt;
&lt;br /&gt;
Falls Sie von uns eine neue Sattelstrebe erworben haben, erhalten Sie von uns beiliegend die einklebbaren Lineale. Diese müssten Sie selber einkleben, da wir Ihre Referenzmasse an Ihrem Ergometer, z.B. zwischen Tretlagerachse und Sattelspitze, nicht kennen.  &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Sitzposition ==&lt;br /&gt;
&lt;br /&gt;
Das SRM - Ergometer erlaubt eine individuelle Einstellung der Sitzposition des Athleten. So können durch Positionsveränderungen von Lenkerstütze, Lenkerstrebe, Sattelstütze, Sattelstrebe und Kurbellänge individuell eingestellt werden. &lt;br /&gt;
&lt;br /&gt;
Die Skalierung der Sattelstütze gibt den Abstand von der Mitte der Tretlagerachse zur Sattelspitze wieder. &lt;br /&gt;
&lt;br /&gt;
In der folgenden Tabelle finden Sie dazu die Spannweiten von Lenker und Sattel, der Referenzpunkt ist die Mitte des Tretlagers. &lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
!style=&amp;quot;width:30%&amp;quot;| Bezeichnung !! style=&amp;quot;width:30%&amp;quot; | Bewegungsebene&lt;br /&gt;
!style=&amp;quot;width:30%&amp;quot;| Spannweite&lt;br /&gt;
|-&lt;br /&gt;
| Sattel     || horizontal || -15cm - 10cm&lt;br /&gt;
|-&lt;br /&gt;
|            || vertikal ||   60cm - 85cm&lt;br /&gt;
|-&lt;br /&gt;
| Lenker || horizontal  || 35cm - 60cm&lt;br /&gt;
|-&lt;br /&gt;
|       || vertikal || 45cm - 65cm&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Nachträgliche Verlegung des Torque Kabels==&lt;br /&gt;
&lt;br /&gt;
Sind Sie Inhaber eines älteren Ergometers besteht die Möglichkeit die neue Torque Analyse für Windows zusammen mit Ihrem Ergometer zu nutzen. Wir empfehlen dabei das zugehörige Sensorkabel nachträglich intern zu verlegen. Das Manual zur Verlegung finden Sie unter dem folgenden Link: [[Media:Manual Torque-Sensorkabels (SRM Ergometer), Stefan Lorenz.pdf|Manual Sensorkabel-Verlegung]]&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&amp;lt;br /&amp;gt;&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==LogFile==&lt;br /&gt;
&lt;br /&gt;
Der LogFile eines Tests gibt SRM eine Reihe an Informationen, inwieweit das Ergometer funktioniert und wo mögliche Fehlerquellen liegen können. Falls Probleme bei der Funktion des Ergometers auftreten sollten, ist es für SRM immer hilfreich einen LogFile zusätzlich zur Problembeschreibung zu erhalten. So ist eine schnelle Problemidentifizierung und Rückmeldung seitens SRM möglich.&lt;br /&gt;
&lt;br /&gt;
Für einen LogFile ist Folgendes zu beachten:&lt;br /&gt;
:*Den LogFile (Testwerte.txt) findet man unter dem Pfad: „C:\Users\Public\Documents\SRM\_data.srm\OnlineTestwerte\”&lt;br /&gt;
:*Der LogFile eines Tests wird mit dem Start eines neuen Tests überschrieben. Daher muss der LogFile von einem bestimmten Test immer direkt im Anschluss an den Test kopiert und exportiert werden.&lt;br /&gt;
&lt;br /&gt;
Sollte bei Ihnen ein Problem mit dem Ergometer auftreten und Sie uns einen LogFile zuschicken, gehen Sie wie folgt vor:&lt;br /&gt;
:*Fahren Sie einen kurzen Stufentest mit ca. 3-4 Stufen (Beginn z.B. bei 80 W, Dauer 3 min/Stufe, Steigung um 20 W)&lt;br /&gt;
:*Aufnahme eines Screenshots&lt;br /&gt;
:*Den SRM-Trainingsfile exportieren&lt;br /&gt;
:*Den LogFile kopieren/exportieren&lt;br /&gt;
:*Lassen Sie beides SRM zukommen&lt;br /&gt;
&lt;br /&gt;
Ein LogFile, den Sie SRM zukommenlassen, sieht beispielhaft wie folgt aus: [[Media:Example LogFile.txt|Beispiel LogFile]]&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Häufig gestellte Fragen==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! Bauteil!! Frage!! Beschreibung!! Link&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Ergometer ||Kann das Ergometer auch mit einem Computer mit Windows 8 gesteuert werden? || Ja. Dazu muss ein Adapterkabel verwendet werden (USB auf serielle Schnittstelle) || Informationen zu [[Kalibrierung des Ergometers#SRMWin - Software: Einstellung USB/Seriell Adapter im Active Port |USB / Seriell Adaptern]]&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|  ||Das Tastenfeld des PowerControl IV lässt sich nicht mehr bedienen. || Es gibt möglicherweise ein Problem bei der Verbindung zwischen dem Tastenfeld und der Elektronik im PowerControl IV.|| Bitte füllen Sie ein Serviceformular aus und senden Sie es zusammen mit Ihrem PowerControl IV an SRM.&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || Leistung wird nicht korrekt angezeigt || Nullstelle des PowerMeters ist nicht richtig im PowerControl IV eingestellt. Überprüfen Sie die Nullstelle in Ihrem PowerControl IV.|| [[Kalibrierung des Ergometers#Nullstellenkalibrierung des PowerMeters |Einstellung Nullstelle]]&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || || Überprüfen Sie die Steigung in Ihrem PowerControl IV. Bei kompletter Entladung des PowerControl IV verliert das PowerControl IV diesen Wert. Ebenfalls muss die Steigung bei einem Wechsel des PowerControl IV überprüft oder neu eingeben werden. || [[Kalibrierung des Ergometers#SRMWin - Software: Powercontrol Setup |Einstellung Steigung]] &lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || || Einstellungen im PowerControl IV Setup lassen sich nicht speichen. || Evtl. ist die Verbindung PowerControl IV zur Steuerung oder zur SRMWIN - Software im unterbrochen. Bitte überprüfen Sie die Kabelverbindungen und den Ladezustand Ihres PowerControl IV.  &lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Ergometer ||Keine Bremsleistung am Ergometer ||Netzteil ausgeschaltet || Netzteil einschalten&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || || Netzteil Sicherung durchgebrannt|| Netzteilsicherung wechseln (220Volt, 1.6 Ampere träge)&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || || || Netzteil zur Überprüfung einschicken &lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || || Elektronik des Netzteiles beschädigt|| Netzteil durch Software einschalten &lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || || Netzteil durch Software ausgeschaltet|| Regelparameter / Schnittstelle Regelung (an- aus) auf ein stellen&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || || Verkabelung des Ergometers beschädigt|| Bitte kontaktieren Sie uns!&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || Keine Bremsleistung am Ergometer während eines Testes || Software schaltet Netzteil ab, sobald Tretfrequenz länger als 3 s unter 25 U / min fällt|| Während eines Testes nicht aufhören zu treten! Bitte kürzere Intervalle programmieren, um die Leerlaufzeit bis zur nächsten Stufe kürzer zu gestalten, z.B. statt 4 min. 300 Watt, 4 x 1 min 300 Watt programmieren!&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|PowerMeter || Leistungs- oder Trittfrequenzdaten werden nicht angezeigt, fluktuieren oder sind ungenau|| Die Batterie ist fast leer oder die Platine des PowerMeters ist beschädigt. || PowerMeter zum Service inkl. Batteriewechsel zu uns einschicken! &lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || || Verkabelung des Ergometers ist nicht in Ordnung || Bitte kontaktieren Sie uns! &lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || || Der Trittfrequenzmagnet befindet sich nicht in der richtigen Position über dem Reed Schalter. ||   &lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || || || Die [[Kalibrierung des Ergometers#Nullstellenkalibrierung des PowerMeters |Nullstelle]] muss eingestellt werden!&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || || Die spezifische Steigung ist nicht richtig in das PowerControl eingegeben worden, oder der PowerMeter überträgt nicht die richtige spezifische Steigung an das PowerControl.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Software||Tretfrequenz im isokinetischen Mode stimmt nicht mit vorgegebener Frequenz aus Vorgabedatei überein  || Eingestellter Gang ist nicht richtig|| Bitte 9. Gang einlegen&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || || Übersetzungsverhältnis im Online Setup ist nicht korrekt eingestellt ||  [[SRM-Online Einstellungen in der SRMWin-Software#Die Extra Registerkarte|Übersetzung]] isokinetischer Test auf 53/13 &lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
&lt;br /&gt;
| ||Logfile || Lassen Sie uns Ihren so genannten Logfile zukommen. Die SRMWIN-Software schreibt bei jedem Test einen Logfile mit dessen Hilfe sich Probleme erkennen lassen. Bitte beachten Sie dass Sie die Datei nach Beendigung der SRMWIN-Software gesichert werden sollte, da die Datei beim jeweiligen Öffnen des Ergometer Modus wieder überschrieben wird. || Das Logfile befindet sich unter: C:\Users\Public\Documents\SRM\_data.srm\OnlineTestwerte\Testwerte.txt&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
| || || Einstellungen im PowerControl Setup wie z.B. &amp;quot;Slope&amp;quot; oder “Circumference of tire“ lassen sich zwar ändern, aber nicht speichen || Das PowerControl muss von uns neu resettet werden, bitte kontaktieren Sie uns!&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| ||Die Geschwindigkeit wird nicht korrekt angezeigt.  || || [[Kalibrierung des Ergometers#SRMWin - Software: Powercontrol Setup |Radumfang]] auf 1000 mm einstellen, bevorzugte Einheit einstellen (metric oder imperial)!&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Herzfrequenzsender|| Artefakte bei der Herzfrequenzmessung || Ungeeigneter Herzfrequenzsender||     Folgende Sensoren sind mit dem PowerControl VI kompatibel: Polar T31 Wearlink, Suunto Dual. Folgende Sensoren sind mit dem PowerControl 7 kompatibel: Suunto Dual, Garmin ANT+. &lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || || Batterie im Herzfrequenzsender leer|| Neuen Herzfrequenzsender besorgen oder Batterie wechseln &lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kurbel|| Geräusch beim Fahren|| Inbusschreiben sind nicht fest genug angezogen an den verlängerbaren Kurbeln  || &lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || || Ergometer steht nicht auf einer ebenen Oberfläche  || &lt;br /&gt;
&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=MediaWiki:Sidebar&amp;diff=2054</id>
		<title>MediaWiki:Sidebar</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=MediaWiki:Sidebar&amp;diff=2054"/>
				<updated>2017-04-23T11:15:15Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;** Einleitung|Einleitung&lt;br /&gt;
&lt;br /&gt;
** Mechanische Grundlagen|Mechanische Grundlagen&lt;br /&gt;
** Elektronische Grundlagen|Elektronische Grundlagen&lt;br /&gt;
** Kalibrierung des Ergometers|Kalibrierung&lt;br /&gt;
** SRM-Online Einstellungen in der SRMWin-Software|SRM-Online Einstellungen&lt;br /&gt;
** SRM-Online in der praktischen Darstellung|SRM-Online Praxis&lt;br /&gt;
** Datenexport|Datenexport  &lt;br /&gt;
** Torque Analysis - Tretkraftanalyse|Tretkraftanalyse&lt;br /&gt;
** Wartung und Service|Wartung &amp;amp; Service&lt;br /&gt;
** FAQ's|FAQ's&lt;br /&gt;
** Troubleshooting|Troubleshooting&lt;br /&gt;
** Handbücher|Handbücher&lt;br /&gt;
** Internationale Literatur zum SRM-Ergometer|Literatur&lt;br /&gt;
** Referenzen|Referenzen&lt;br /&gt;
&lt;br /&gt;
* Quick Links&lt;br /&gt;
** recentchanges-url|recentchanges&lt;br /&gt;
** {{SERVER}}{{SCRIPTPATH}}/index.php?title=MediaWiki:Sidebar&amp;amp;action=edit| Edit Navigation&lt;br /&gt;
&lt;br /&gt;
* TOOLBOX&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=FAQ%27s_zum_SRM-Ergometer&amp;diff=2053</id>
		<title>FAQ's zum SRM-Ergometer</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=FAQ%27s_zum_SRM-Ergometer&amp;diff=2053"/>
				<updated>2017-04-23T11:09:35Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{languages&lt;br /&gt;
|de=FAQ's&lt;br /&gt;
|en=FAQs&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
==Lichtschranke==&lt;br /&gt;
&lt;br /&gt;
Die Lichtschranke misst an der so genannten Unterbrecherscheibe die Geschwindigkeit (Speed) der Schwungmassen. Sie ist für die Berechnung der Leitung obligatorisch. Wird Speed nicht korrekt gemessen kann die Leistung nicht berechnet werden. Die angezeigten Speedwerte in der SRMWin-Software - z.B. während eines Leistungstests - entsprechen keinen realen Geschwindigkeitswerten.&lt;br /&gt;
&lt;br /&gt;
In den folgenden Abbildungen ist die Position der Lichtschranke im Getriebe zu erkennen. Um die Lichtschranke zu reinigen oder Ihre Position zu verändern müssen die Schwungmassen abgenommen werden.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
 File:Isokinetischer_Test_2.jpg|Speed Anzeige während eines Testes (hier 31,3 km/h)&lt;br /&gt;
 File:00-Lichtschranke-ort.jpg|Abnehmen der Schwungscheiben&lt;br /&gt;
 File:01-Lichtschranke-ort.jpg|Position des Lichtschranke&lt;br /&gt;
 File:02-Lichtschranke-ort.jpg|Position der Lichtschranke an der Unterbrecherscheibe (offen)&lt;br /&gt;
 File:03-Lichtschranke-ort.jpg|Position der Lichtschranke an der Unterbrecherscheibe (geschlossen)&lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Netzteil / Powersupply ==&lt;br /&gt;
&lt;br /&gt;
[[File:SRM-PowerSupply-01.jpg|thumb|Powersupply mit leuchtender grüner Lampe]]&lt;br /&gt;
&lt;br /&gt;
* '''Grüne Lampe leuchtet nicht'''&lt;br /&gt;
&lt;br /&gt;
: Leuchtet die grüne Lampe nach dem Einschalten nicht, ist das Netzteil defekt. Bitte schicken Sie es an SRM zum Service ein.&lt;br /&gt;
&lt;br /&gt;
* '''Orange Lampe leuchtet nicht kurz auf'''&lt;br /&gt;
&lt;br /&gt;
: Beim Einschalten des Netzteils sollte die orangene Lampe kurz aufleuchten. Ist dieses nicht der Fall sind evtl. Sicherungen durchgebrannt. Schicken Sie es dann bitte an SRM zum Service ein.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Sattelstütze ==&lt;br /&gt;
&lt;br /&gt;
[[File:SRM-Sattelstütze-(Bezeichnungen).jpg|thumb|Bezeichnungen der Sattelstütze]]&lt;br /&gt;
&lt;br /&gt;
Die Bezeichnungen der Sattelstütze finden Sie auf dem angehängten Foto. Falls Sie Ersatzteile der Sattelstütze benötigen, lassen Sie uns bitte die korrekten Bezeichnungen inkl. des Baujahrs des SRM - Ergometers zukommen.&lt;br /&gt;
&lt;br /&gt;
Falls Sie von uns eine neue Sattelstrebe erworben haben, erhalten Sie von uns beiliegend die einklebbaren Lineale. Diese müssten Sie selber einkleben, da wir Ihre Referenzmasse an Ihrem Ergometer, z.B. zwischen Tretlagerachse und Sattelspitze, nicht kennen.  &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Sitzposition ==&lt;br /&gt;
&lt;br /&gt;
Das SRM - Ergometer erlaubt eine individuelle Einstellung der Sitzposition des Athleten. So können durch Positionsveränderungen von Lenkerstütze, Lenkerstrebe, Sattelstütze, Sattelstrebe und Kurbellänge individuell eingestellt werden. &lt;br /&gt;
&lt;br /&gt;
Die Skalierung der Sattelstütze gibt den Abstand von der Mitte der Tretlagerachse zur Sattelspitze wieder. &lt;br /&gt;
&lt;br /&gt;
In der folgenden Tabelle finden Sie dazu die Spannweiten von Lenker und Sattel, der Referenzpunkt ist die Mitte des Tretlagers. &lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
!style=&amp;quot;width:30%&amp;quot;| Bezeichnung !! style=&amp;quot;width:30%&amp;quot; | Bewegungsebene&lt;br /&gt;
!style=&amp;quot;width:30%&amp;quot;| Spannweite&lt;br /&gt;
|-&lt;br /&gt;
| Sattel     || horizontal || -15cm - 10cm&lt;br /&gt;
|-&lt;br /&gt;
|            || vertikal ||   60cm - 85cm&lt;br /&gt;
|-&lt;br /&gt;
| Lenker || horizontal  || 35cm - 60cm&lt;br /&gt;
|-&lt;br /&gt;
|       || vertikal || 45cm - 65cm&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Nachträgliche Verlegung des Torque Kabels==&lt;br /&gt;
&lt;br /&gt;
Sind Sie Inhaber eines älteren Ergometers besteht die Möglichkeit die neue Torque Analyse für Windows zusammen mit Ihrem Ergometer zu nutzen. Wir empfehlen dabei das zugehörige Sensorkabel nachträglich intern zu verlegen. Das Manual zur Verlegung finden Sie unter dem folgenden Link: [[Media:Manual Torque-Sensorkabels (SRM Ergometer), Stefan Lorenz.pdf|Manual Sensorkabel-Verlegung]]&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&amp;lt;br /&amp;gt;&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==LogFile==&lt;br /&gt;
&lt;br /&gt;
Der LogFile eines Tests gibt SRM eine Reihe an Informationen, inwieweit das Ergometer funktioniert und wo mögliche Fehlerquellen liegen können. Falls Probleme bei der Funktion des Ergometers auftreten sollten, ist es für SRM immer hilfreich einen LogFile zusätzlich zur Problembeschreibung zu erhalten. So ist eine schnelle Problemidentifizierung und Rückmeldung seitens SRM möglich.&lt;br /&gt;
&lt;br /&gt;
Für einen LogFile ist Folgendes zu beachten:&lt;br /&gt;
:*Den LogFile (Testwerte.txt) findet man unter dem Pfad: „C:\Users\Public\Documents\SRM\_data.srm\OnlineTestwerte\”&lt;br /&gt;
:*Der LogFile eines Tests wird mit dem Start eines neuen Tests überschrieben. Daher muss der LogFile von einem bestimmten Test immer direkt im Anschluss an den Test kopiert und exportiert werden.&lt;br /&gt;
&lt;br /&gt;
Sollte bei Ihnen ein Problem mit dem Ergometer auftreten und Sie uns einen LogFile zuschicken, gehen Sie wie folgt vor:&lt;br /&gt;
:*Fahren Sie einen kurzen Stufentest mit ca. 3-4 Stufen (Beginn z.B. bei 80 W, Dauer 3 min/Stufe, Steigung um 20 W)&lt;br /&gt;
:*Aufnahme eines Screenshots&lt;br /&gt;
:*Den SRM-Trainingsfile exportieren&lt;br /&gt;
:*Den LogFile kopieren/exportieren&lt;br /&gt;
:*Lassen Sie beides SRM zukommen&lt;br /&gt;
&lt;br /&gt;
Ein LogFile, den Sie SRM zukommenlassen, sieht beispielhaft wie folgt aus: [[Media:Example LogFile.txt|Beispiel LogFile]]&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Häufig gestellte Fragen==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! Bauteil!! Frage!! Beschreibung!! Link&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Ergometer ||Kann das Ergometer auch mit einem Computer mit Windows 8 gesteuert werden? || Ja. Dazu muss ein Adapterkabel verwendet werden (USB auf serielle Schnittstelle) || Informationen zu [[Kalibrierung des Ergometers#SRMWin - Software: Einstellung USB/Seriell Adapter im Active Port |USB / Seriell Adaptern]]&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|  ||Das Tastenfeld des PowerControl IV lässt sich nicht mehr bedienen. || Es gibt möglicherweise ein Problem bei der Verbindung zwischen dem Tastenfeld und der Elektronik im PowerControl IV.|| Bitte füllen Sie ein Serviceformular aus und senden Sie es zusammen mit Ihrem PowerControl IV an SRM.&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || Leistung wird nicht korrekt angezeigt || Nullstelle des PowerMeters ist nicht richtig im PowerControl IV eingestellt. Überprüfen Sie die Nullstelle in Ihrem PowerControl IV.|| [[Kalibrierung des Ergometers#Nullstellenkalibrierung des PowerMeters |Einstellung Nullstelle]]&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || || Überprüfen Sie die Steigung in Ihrem PowerControl IV. Bei kompletter Entladung des PowerControl IV verliert das PowerControl IV diesen Wert. Ebenfalls muss die Steigung bei einem Wechsel des PowerControl IV überprüft oder neu eingeben werden. || [[Kalibrierung des Ergometers#SRMWin - Software: Powercontrol Setup |Einstellung Steigung]] &lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || || Einstellungen im PowerControl IV Setup lassen sich nicht speichen. || Evtl. ist die Verbindung PowerControl IV zur Steuerung oder zur SRMWIN - Software im unterbrochen. Bitte überprüfen Sie die Kabelverbindungen und den Ladezustand Ihres PowerControl IV.  &lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Ergometer ||Keine Bremsleistung am Ergometer ||Netzteil ausgeschaltet || Netzteil einschalten&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || || Netzteil Sicherung durchgebrannt|| Netzteilsicherung wechseln (220Volt, 1.6 Ampere träge)&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || || || Netzteil zur Überprüfung einschicken &lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || || Elektronik des Netzteiles beschädigt|| Netzteil durch Software einschalten &lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || || Netzteil durch Software ausgeschaltet|| Regelparameter / Schnittstelle Regelung (an- aus) auf ein stellen&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || || Verkabelung des Ergometers beschädigt|| Bitte kontaktieren Sie uns!&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || Keine Bremsleistung am Ergometer während eines Testes || Software schaltet Netzteil ab, sobald Tretfrequenz länger als 3 s unter 25 U / min fällt|| Während eines Testes nicht aufhören zu treten! Bitte kürzere Intervalle programmieren, um die Leerlaufzeit bis zur nächsten Stufe kürzer zu gestalten, z.B. statt 4 min. 300 Watt, 4 x 1 min 300 Watt programmieren!&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|PowerMeter || Leistungs- oder Trittfrequenzdaten werden nicht angezeigt, fluktuieren oder sind ungenau|| Die Batterie ist fast leer oder die Platine des PowerMeters ist beschädigt. || PowerMeter zum Service inkl. Batteriewechsel zu uns einschicken! &lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || || Verkabelung des Ergometers ist nicht in Ordnung || Bitte kontaktieren Sie uns! &lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || || Der Trittfrequenzmagnet befindet sich nicht in der richtigen Position über dem Reed Schalter. ||   &lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || || || Die [[Kalibrierung des Ergometers#Nullstellenkalibrierung des PowerMeters |Nullstelle]] muss eingestellt werden!&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || || Die spezifische Steigung ist nicht richtig in das PowerControl eingegeben worden, oder der PowerMeter überträgt nicht die richtige spezifische Steigung an das PowerControl.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Software||Tretfrequenz im isokinetischen Mode stimmt nicht mit vorgegebener Frequenz aus Vorgabedatei überein  || Eingestellter Gang ist nicht richtig|| Bitte 9. Gang einlegen&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || || Übersetzungsverhältnis im Online Setup ist nicht korrekt eingestellt ||  [[SRM-Online Einstellungen in der SRMWin-Software#Die Extra Registerkarte|Übersetzung]] isokinetischer Test auf 53/13 &lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
&lt;br /&gt;
| ||Logfile || Lassen Sie uns Ihren so genannten Logfile zukommen. Die SRMWIN-Software schreibt bei jedem Test einen Logfile mit dessen Hilfe sich Probleme erkennen lassen. Bitte beachten Sie dass Sie die Datei nach Beendigung der SRMWIN-Software gesichert werden sollte, da die Datei beim jeweiligen Öffnen des Ergometer Modus wieder überschrieben wird. || Das Logfile befindet sich unter: C:\Users\Public\Documents\SRM\_data.srm\OnlineTestwerte\Testwerte.txt&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
| || || Einstellungen im PowerControl Setup wie z.B. &amp;quot;Slope&amp;quot; oder “Circumference of tire“ lassen sich zwar ändern, aber nicht speichen || Das PowerControl muss von uns neu resettet werden, bitte kontaktieren Sie uns!&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| ||Die Geschwindigkeit wird nicht korrekt angezeigt.  || || [[Kalibrierung des Ergometers#SRMWin - Software: Powercontrol Setup |Radumfang]] auf 1000 mm einstellen, bevorzugte Einheit einstellen (metric oder imperial)!&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Herzfrequenzsender|| Artefakte bei der Herzfrequenzmessung || Ungeeigneter Herzfrequenzsender||     Folgende Sensoren sind mit dem PowerControl VI kompatibel: Polar T31 Wearlink, Suunto Dual. Folgende Sensoren sind mit dem PowerControl 7 kompatibel: Suunto Dual, Garmin ANT+. &lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || || Batterie im Herzfrequenzsender leer|| Neuen Herzfrequenzsender besorgen oder Batterie wechseln &lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kurbel|| Geräusch beim Fahren|| Inbusschreiben sind nicht fest genug angezogen an den verlängerbaren Kurbeln  || &lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| || || Ergometer steht nicht auf einer ebenen Oberfläche  || &lt;br /&gt;
&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=MediaWiki:Sidebar&amp;diff=2048</id>
		<title>MediaWiki:Sidebar</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=MediaWiki:Sidebar&amp;diff=2048"/>
				<updated>2017-04-19T10:42:55Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;** Einleitung|Einleitung&lt;br /&gt;
&lt;br /&gt;
** Mechanische Grundlagen|Mechanische Grundlagen&lt;br /&gt;
** Elektronische Grundlagen|Elektronische Grundlagen&lt;br /&gt;
** Kalibrierung des Ergometers|Kalibrierung&lt;br /&gt;
** SRM-Online Einstellungen in der SRMWin-Software|SRM-Online Einstellungen&lt;br /&gt;
** SRM-Online in der praktischen Darstellung|SRM-Online Praxis&lt;br /&gt;
** Datenexport|Datenexport  &lt;br /&gt;
** Torque Analysis - Tretkraftanalyse|Tretkraftanalyse&lt;br /&gt;
** Wartung und Service|Wartung &amp;amp; Service&lt;br /&gt;
** FAQ's zum SRM-Ergometer|FAQ's&lt;br /&gt;
** Troubleshooting|Troubleshooting&lt;br /&gt;
** Handbücher|Handbücher&lt;br /&gt;
** Internationale Literatur zum SRM-Ergometer|Literatur&lt;br /&gt;
** Referenzen|Referenzen&lt;br /&gt;
&lt;br /&gt;
* Quick Links&lt;br /&gt;
** recentchanges-url|recentchanges&lt;br /&gt;
** {{SERVER}}{{SCRIPTPATH}}/index.php?title=MediaWiki:Sidebar&amp;amp;action=edit| Edit Navigation&lt;br /&gt;
&lt;br /&gt;
* TOOLBOX&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Wartung_und_Service&amp;diff=2047</id>
		<title>Wartung und Service</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Wartung_und_Service&amp;diff=2047"/>
				<updated>2017-04-19T10:41:06Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{languages&lt;br /&gt;
|de=Wartung und Service&lt;br /&gt;
|en=Maintenance and Service&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
Die Wartung des SRM - Ergometers ist Voraussetzung, um über längere Zeiträume exakte Leistunsgdaten zu erhalten. Daher empfehlen wir vor jeder Messung die Kalibrierung durchzuführen bzw. die Einstellungen zu kontrollieren.&lt;br /&gt;
&lt;br /&gt;
==Batteriewechel beim PowerMeter==&lt;br /&gt;
Nach ca. 1800 Bertiebsstunden sollte die Batterie des PowerMeters gewechselt werden. Dafür müssen Sie den PowerMeter und das PowerControl zu uns schicken. Gleichzeitig mit dem Batterienwechsel werden PowerMeter und PowerControl überprüft und neu kalibriert.&lt;br /&gt;
&lt;br /&gt;
==Austausch Pedale, Lenker, Sattel, Kurbel, PowerMeter und Kettenblatt==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[File:Setup-PowerControl.jpg|thumb|Einstellung der neuen Steigung (Slope) bei Wechsel des PowerMeters]]&lt;br /&gt;
[[File:020-Isokinetic-Gear-Change-53.jpg|thumb|Änderung der Übersetzung im isokinetischen Modus bei Wechsel des Kettenblattes]]&lt;br /&gt;
&lt;br /&gt;
Pedale, Lenker, Sattel können mit konventionellem Werkzeug vom Benutzer selbst getauscht werden. Bei Austausch der Kurbeln ist darauf zu achten, dass die 5 Befestigungsschrauben Kurbel - PowerMeter und die Befestigungsschraube Kurbel - Achse nach erfolgtem Wechsel wieder fest angezogen werden. &lt;br /&gt;
&lt;br /&gt;
Die Kettenblattschrauben ca. mit 8 - 10 Nm, die Kurbel auf die Tretlagerachse mit ca. 40 Nm anziehen. Die Steigung des PowerMeter ändert sich hierbei nicht. Die Nullstelle muss nach der Montage neu eingestellt werden. Sie sollte auch noch anfangs öfter überprüft werden, da sich die Schrauben wärend des Betriebes noch setzen, und sich dadurch die Nullstelle ändern kann.&lt;br /&gt;
&lt;br /&gt;
Beim Einsatz eines anderen PowerMeters muss in der SRMWin - Software die entsprechende neue Steigung (Abgabesignal des PowerMeters in Hz / Nm) eingegeben werden. &lt;br /&gt;
&lt;br /&gt;
Wenn ein Kettenblatt mit einer anderen Zähnezahl (Standardmäßig 53) am PowerMeter eingesetzt wird, muss in der SRMWin - Software die Übersetzung geändert werden, um die gewünschte Tretfrequenz bei den Tests zu erhalten (SRM-Online - Options - Extra - Gearing Isokinetic Mode).&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Kette==&lt;br /&gt;
Die Teile mit dem größten Verschleiß sind die Kette und die Antriebsritzel. Bei häufigem Wechsel der Kette ist der Ritzelverschleiß entsprechend geringer. Die Kette sollte ca. alle 500 Betriebsstunden gegen eine neue getauscht werden. Dazu ist es notwendig, dass die rechte Abdeckhaube des Ergometers entfernt wird. Sie ist mit sechs 5mm Inbusschrauben befestigt. Danach kann die Kette mit einem Nietendrücker geöffnet und gegen eine neue getauscht werden. Hierbei ist es auch möglich, die Indizierung der Schaltung neu einzustellen bzw. zu überprüfen. Im 4. Gang müssen beide roten Markierungen der Schaltungshebel an der Nabe gegenüber stehen. &lt;br /&gt;
Während des Betriebes ist darauf zu achten, dass die Kette nicht trockenläuft und immer ausreichend mit Öl oder Fett geschmiert ist.  &lt;br /&gt;
&lt;br /&gt;
==Pflege des Ergometergehäuses==&lt;br /&gt;
Das Ergometergehäuse sollte mit einem feuchten Lappen und etwas mildem Reinigungsmittel gesäubert werden. Jedoch nicht mit einem starken Lösungsmittel wie Aceton oder Nitroverdünnung. Insbesondere der Schweiß der Athleten sollte nach Belastungsende immer abgewischt werden. Ebenso sollten die Stangen zur Sattel- und Lenkerverstellung immer ausreichend mit Fett geschmiert sein.&lt;br /&gt;
&lt;br /&gt;
==Wartungsintervalle==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; |- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
!style=&amp;quot;width:30%&amp;quot;| Bauteile!! style=&amp;quot;width:30%&amp;quot; | Service&lt;br /&gt;
!style=&amp;quot;width:30%&amp;quot;| Empfohlener Zeitraum&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| SRM - Kurbel und PowerControl|| &lt;br /&gt;
* Batteriewechsel und Kalibrierung des PowerMeters&lt;br /&gt;
* Akkuwechsel und Überprüfung des PowerControl IV&lt;br /&gt;
|| &lt;br /&gt;
* alle 2 Jahre&lt;br /&gt;
* Die SRM - Kurbel und das PowerControl müssen für den Service zu uns eingeschickt werden.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Komplettes Ergometer|| &lt;br /&gt;
* Batteriewechsel, Kalibrierung SRM - Kurbel und PowerControl&lt;br /&gt;
* Service Rohloff (Ölwechsel, etc.)&lt;br /&gt;
* Überprüfung Gertriebe, Lager und Schwungmassen&lt;br /&gt;
* allg. Prüfung Anschlüsse und Kabel&lt;br /&gt;
* Überprüfung mechanische Bauteile Klemmhebel, Sattestütze, Sattelstrebe, Lenkerstrebe,- u. stütze&lt;br /&gt;
* Erneuerung / Austausch Verschleißteile (Kettenblätter, Kette, Lenkerband, evtl. Sattel, etc.)&lt;br /&gt;
* Komplettsäuberung des Ergometers&lt;br /&gt;
* optionales Sandstrahlen und neue Pulverbeschichtung (abhängig vom Zustand des Ergometers )&lt;br /&gt;
* optionales upgrade für die Windows [http://www.srm.de/de/produkte/tretkraftanalyse/ Torque Analyse]&lt;br /&gt;
||&lt;br /&gt;
* alle 4 Jahre&lt;br /&gt;
* Das Ergometer inkl. aller Kabel und Netzteil muss für den 4 jährigen Service zu uns eingeschickt werden&lt;br /&gt;
* wir empfehlern das Ergometer in einer abgeschlossenen Box zu uns zu schicken&lt;br /&gt;
* die Kosten sind abhängig vom Umfang der notwendigen Reparaturen; ein Kostenvoranschlag wird nach Eingang und Untersuchung des Ergometers erstellt&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Wartung_%26_Service&amp;diff=2046</id>
		<title>Wartung &amp; Service</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Wartung_%26_Service&amp;diff=2046"/>
				<updated>2017-04-19T10:37:38Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{languages&lt;br /&gt;
|de=Wartung und Service&lt;br /&gt;
|en=Maintenance and Service&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
Die Wartung des SRM - Ergometers ist Voraussetzung, um über längere Zeiträume exakte Leistunsgdaten zu erhalten. Daher empfehlen wir vor jeder Messung die Kalibrierung durchzuführen bzw. die Einstellungen zu kontrollieren.&lt;br /&gt;
&lt;br /&gt;
==Batteriewechel beim PowerMeter==&lt;br /&gt;
Nach ca. 1800 Bertiebsstunden sollte die Batterie des PowerMeters gewechselt werden. Dafür müssen Sie den PowerMeter und das PowerControl zu uns schicken. Gleichzeitig mit dem Batterienwechsel werden PowerMeter und PowerControl überprüft und neu kalibriert.&lt;br /&gt;
&lt;br /&gt;
==Austausch Pedale, Lenker, Sattel, Kurbel, PowerMeter und Kettenblatt==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[File:Setup-PowerControl.jpg|thumb|Einstellung der neuen Steigung (Slope) bei Wechsel des PowerMeters]]&lt;br /&gt;
[[File:020-Isokinetic-Gear-Change-53.jpg|thumb|Änderung der Übersetzung im isokinetischen Modus bei Wechsel des Kettenblattes]]&lt;br /&gt;
&lt;br /&gt;
Pedale, Lenker, Sattel können mit konventionellem Werkzeug vom Benutzer selbst getauscht werden. Bei Austausch der Kurbeln ist darauf zu achten, dass die 5 Befestigungsschrauben Kurbel - PowerMeter und die Befestigungsschraube Kurbel - Achse nach erfolgtem Wechsel wieder fest angezogen werden. &lt;br /&gt;
&lt;br /&gt;
Die Kettenblattschrauben ca. mit 8 - 10 Nm, die Kurbel auf die Tretlagerachse mit ca. 40 Nm anziehen. Die Steigung des PowerMeter ändert sich hierbei nicht. Die Nullstelle muss nach der Montage neu eingestellt werden. Sie sollte auch noch anfangs öfter überprüft werden, da sich die Schrauben wärend des Betriebes noch setzen, und sich dadurch die Nullstelle ändern kann.&lt;br /&gt;
&lt;br /&gt;
Beim Einsatz eines anderen PowerMeters muss in der SRMWin - Software die entsprechende neue Steigung (Abgabesignal des PowerMeters in Hz / Nm) eingegeben werden. &lt;br /&gt;
&lt;br /&gt;
Wenn ein Kettenblatt mit einer anderen Zähnezahl (Standardmäßig 53) am PowerMeter eingesetzt wird, muss in der SRMWin - Software die Übersetzung geändert werden, um die gewünschte Tretfrequenz bei den Tests zu erhalten (SRM-Online - Options - Extra - Gearing Isokinetic Mode).&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Kette==&lt;br /&gt;
Die Teile mit dem größten Verschleiß sind die Kette und die Antriebsritzel. Bei häufigem Wechsel der Kette ist der Ritzelverschleiß entsprechend geringer. Die Kette sollte ca. alle 500 Betriebsstunden gegen eine neue getauscht werden. Dazu ist es notwendig, dass die rechte Abdeckhaube des Ergometers entfernt wird. Sie ist mit sechs 5mm Inbusschrauben befestigt. Danach kann die Kette mit einem Nietendrücker geöffnet und gegen eine neue getauscht werden. Hierbei ist es auch möglich, die Indizierung der Schaltung neu einzustellen bzw. zu überprüfen. Im 4. Gang müssen beide roten Markierungen der Schaltungshebel an der Nabe gegenüber stehen. &lt;br /&gt;
Während des Betriebes ist darauf zu achten, dass die Kette nicht trockenläuft und immer ausreichend mit Öl oder Fett geschmiert ist.  &lt;br /&gt;
&lt;br /&gt;
==Pflege des Ergometergehäuses==&lt;br /&gt;
Das Ergometergehäuse sollte mit einem feuchten Lappen und etwas mildem Reinigungsmittel gesäubert werden. Jedoch nicht mit einem starken Lösungsmittel wie Aceton oder Nitroverdünnung. Insbesondere der Schweiß der Athleten sollte nach Belastungsende immer abgewischt werden. Ebenso sollten die Stangen zur Sattel- und Lenkerverstellung immer ausreichend mit Fett geschmiert sein.&lt;br /&gt;
&lt;br /&gt;
==Wartungsintervalle==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; |- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
!style=&amp;quot;width:30%&amp;quot;| Bauteile!! style=&amp;quot;width:30%&amp;quot; | Service&lt;br /&gt;
!style=&amp;quot;width:30%&amp;quot;| Empfohlener Zeitraum&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| SRM - Kurbel und PowerControl|| &lt;br /&gt;
* Batteriewechsel und Kalibrierung des PowerMeters&lt;br /&gt;
* Akkuwechsel und Überprüfung des PowerControl IV&lt;br /&gt;
|| &lt;br /&gt;
* alle 2 Jahre&lt;br /&gt;
* Die SRM - Kurbel und das PowerControl müssen für den Service zu uns eingeschickt werden.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Komplettes Ergometer|| &lt;br /&gt;
* Batteriewechsel, Kalibrierung SRM - Kurbel und PowerControl&lt;br /&gt;
* Service Rohloff (Ölwechsel, etc.)&lt;br /&gt;
* Überprüfung Gertriebe, Lager und Schwungmassen&lt;br /&gt;
* allg. Prüfung Anschlüsse und Kabel&lt;br /&gt;
* Überprüfung mechanische Bauteile Klemmhebel, Sattestütze, Sattelstrebe, Lenkerstrebe,- u. stütze&lt;br /&gt;
* Erneuerung / Austausch Verschleißteile (Kettenblätter, Kette, Lenkerband, evtl. Sattel, etc.)&lt;br /&gt;
* Komplettsäuberung des Ergometers&lt;br /&gt;
* optionales Sandstrahlen und neue Pulverbeschichtung (abhängig vom Zustand des Ergometers )&lt;br /&gt;
* optionales upgrade für die Windows [http://www.srm.de/de/produkte/tretkraftanalyse/ Torque Analyse]&lt;br /&gt;
||&lt;br /&gt;
* alle 4 Jahre&lt;br /&gt;
* Das Ergometer inkl. aller Kabel und Netzteil muss für den 4 jährigen Service zu uns eingeschickt werden&lt;br /&gt;
* wir empfehlern das Ergometer in einer abgeschlossenen Box zu uns zu schicken&lt;br /&gt;
* die Kosten sind abhängig vom Umfang der notwendigen Reparaturen; ein Kostenvoranschlag wird nach Eingang und Untersuchung des Ergometers erstellt&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Wartung_und_Service&amp;diff=2045</id>
		<title>Wartung und Service</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Wartung_und_Service&amp;diff=2045"/>
				<updated>2017-04-19T10:36:40Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: Created page with &amp;quot;{{languages |de=Wartung &amp;amp; Service |en=Maintenance &amp;amp; Service }}  Die Wartung des SRM - Ergometers ist Voraussetzung, um über längere Zeiträume exakte Leistunsgdaten zu erhal...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{languages&lt;br /&gt;
|de=Wartung &amp;amp; Service&lt;br /&gt;
|en=Maintenance &amp;amp; Service&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
Die Wartung des SRM - Ergometers ist Voraussetzung, um über längere Zeiträume exakte Leistunsgdaten zu erhalten. Daher empfehlen wir vor jeder Messung die Kalibrierung durchzuführen bzw. die Einstellungen zu kontrollieren.&lt;br /&gt;
&lt;br /&gt;
==Batteriewechel beim PowerMeter==&lt;br /&gt;
Nach ca. 1800 Bertiebsstunden sollte die Batterie des PowerMeters gewechselt werden. Dafür müssen Sie den PowerMeter und das PowerControl zu uns schicken. Gleichzeitig mit dem Batterienwechsel werden PowerMeter und PowerControl überprüft und neu kalibriert.&lt;br /&gt;
&lt;br /&gt;
==Austausch Pedale, Lenker, Sattel, Kurbel, PowerMeter und Kettenblatt==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[File:Setup-PowerControl.jpg|thumb|Einstellung der neuen Steigung (Slope) bei Wechsel des PowerMeters]]&lt;br /&gt;
[[File:020-Isokinetic-Gear-Change-53.jpg|thumb|Änderung der Übersetzung im isokinetischen Modus bei Wechsel des Kettenblattes]]&lt;br /&gt;
&lt;br /&gt;
Pedale, Lenker, Sattel können mit konventionellem Werkzeug vom Benutzer selbst getauscht werden. Bei Austausch der Kurbeln ist darauf zu achten, dass die 5 Befestigungsschrauben Kurbel - PowerMeter und die Befestigungsschraube Kurbel - Achse nach erfolgtem Wechsel wieder fest angezogen werden. &lt;br /&gt;
&lt;br /&gt;
Die Kettenblattschrauben ca. mit 8 - 10 Nm, die Kurbel auf die Tretlagerachse mit ca. 40 Nm anziehen. Die Steigung des PowerMeter ändert sich hierbei nicht. Die Nullstelle muss nach der Montage neu eingestellt werden. Sie sollte auch noch anfangs öfter überprüft werden, da sich die Schrauben wärend des Betriebes noch setzen, und sich dadurch die Nullstelle ändern kann.&lt;br /&gt;
&lt;br /&gt;
Beim Einsatz eines anderen PowerMeters muss in der SRMWin - Software die entsprechende neue Steigung (Abgabesignal des PowerMeters in Hz / Nm) eingegeben werden. &lt;br /&gt;
&lt;br /&gt;
Wenn ein Kettenblatt mit einer anderen Zähnezahl (Standardmäßig 53) am PowerMeter eingesetzt wird, muss in der SRMWin - Software die Übersetzung geändert werden, um die gewünschte Tretfrequenz bei den Tests zu erhalten (SRM-Online - Options - Extra - Gearing Isokinetic Mode).&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Kette==&lt;br /&gt;
Die Teile mit dem größten Verschleiß sind die Kette und die Antriebsritzel. Bei häufigem Wechsel der Kette ist der Ritzelverschleiß entsprechend geringer. Die Kette sollte ca. alle 500 Betriebsstunden gegen eine neue getauscht werden. Dazu ist es notwendig, dass die rechte Abdeckhaube des Ergometers entfernt wird. Sie ist mit sechs 5mm Inbusschrauben befestigt. Danach kann die Kette mit einem Nietendrücker geöffnet und gegen eine neue getauscht werden. Hierbei ist es auch möglich, die Indizierung der Schaltung neu einzustellen bzw. zu überprüfen. Im 4. Gang müssen beide roten Markierungen der Schaltungshebel an der Nabe gegenüber stehen. &lt;br /&gt;
Während des Betriebes ist darauf zu achten, dass die Kette nicht trockenläuft und immer ausreichend mit Öl oder Fett geschmiert ist.  &lt;br /&gt;
&lt;br /&gt;
==Pflege des Ergometergehäuses==&lt;br /&gt;
Das Ergometergehäuse sollte mit einem feuchten Lappen und etwas mildem Reinigungsmittel gesäubert werden. Jedoch nicht mit einem starken Lösungsmittel wie Aceton oder Nitroverdünnung. Insbesondere der Schweiß der Athleten sollte nach Belastungsende immer abgewischt werden. Ebenso sollten die Stangen zur Sattel- und Lenkerverstellung immer ausreichend mit Fett geschmiert sein.&lt;br /&gt;
&lt;br /&gt;
==Wartungsintervalle==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; |- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
!style=&amp;quot;width:30%&amp;quot;| Bauteile!! style=&amp;quot;width:30%&amp;quot; | Service&lt;br /&gt;
!style=&amp;quot;width:30%&amp;quot;| Empfohlener Zeitraum&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| SRM - Kurbel und PowerControl|| &lt;br /&gt;
* Batteriewechsel und Kalibrierung des PowerMeters&lt;br /&gt;
* Akkuwechsel und Überprüfung des PowerControl IV&lt;br /&gt;
|| &lt;br /&gt;
* alle 2 Jahre&lt;br /&gt;
* Die SRM - Kurbel und das PowerControl müssen für den Service zu uns eingeschickt werden.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Komplettes Ergometer|| &lt;br /&gt;
* Batteriewechsel, Kalibrierung SRM - Kurbel und PowerControl&lt;br /&gt;
* Service Rohloff (Ölwechsel, etc.)&lt;br /&gt;
* Überprüfung Gertriebe, Lager und Schwungmassen&lt;br /&gt;
* allg. Prüfung Anschlüsse und Kabel&lt;br /&gt;
* Überprüfung mechanische Bauteile Klemmhebel, Sattestütze, Sattelstrebe, Lenkerstrebe,- u. stütze&lt;br /&gt;
* Erneuerung / Austausch Verschleißteile (Kettenblätter, Kette, Lenkerband, evtl. Sattel, etc.)&lt;br /&gt;
* Komplettsäuberung des Ergometers&lt;br /&gt;
* optionales Sandstrahlen und neue Pulverbeschichtung (abhängig vom Zustand des Ergometers )&lt;br /&gt;
* optionales upgrade für die Windows [http://www.srm.de/de/produkte/tretkraftanalyse/ Torque Analyse]&lt;br /&gt;
||&lt;br /&gt;
* alle 4 Jahre&lt;br /&gt;
* Das Ergometer inkl. aller Kabel und Netzteil muss für den 4 jährigen Service zu uns eingeschickt werden&lt;br /&gt;
* wir empfehlern das Ergometer in einer abgeschlossenen Box zu uns zu schicken&lt;br /&gt;
* die Kosten sind abhängig vom Umfang der notwendigen Reparaturen; ein Kostenvoranschlag wird nach Eingang und Untersuchung des Ergometers erstellt&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=MediaWiki:Sidebar&amp;diff=2044</id>
		<title>MediaWiki:Sidebar</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=MediaWiki:Sidebar&amp;diff=2044"/>
				<updated>2017-04-19T10:31:49Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;** Einleitung|Einleitung&lt;br /&gt;
&lt;br /&gt;
** Mechanische Grundlagen|Mechanische Grundlagen&lt;br /&gt;
** Elektronische Grundlagen|Elektronische Grundlagen&lt;br /&gt;
** Kalibrierung des Ergometers|Kalibrierung&lt;br /&gt;
** SRM-Online Einstellungen in der SRMWin-Software|SRM-Online Einstellungen&lt;br /&gt;
** SRM-Online in der praktischen Darstellung|SRM-Online Praxis&lt;br /&gt;
** Datenexport|Datenexport  &lt;br /&gt;
** Torque Analysis - Tretkraftanalyse|Tretkraftanalyse&lt;br /&gt;
** FAQ's zum SRM-Ergometer|FAQ's&lt;br /&gt;
** Troubleshooting|Troubleshooting&lt;br /&gt;
** Wartung und Service|Wartung &amp;amp; Service&lt;br /&gt;
** Handbücher|Handbücher&lt;br /&gt;
** Internationale Literatur zum SRM-Ergometer|Literatur&lt;br /&gt;
** Referenzen|Referenzen&lt;br /&gt;
&lt;br /&gt;
* Quick Links&lt;br /&gt;
** recentchanges-url|recentchanges&lt;br /&gt;
** {{SERVER}}{{SCRIPTPATH}}/index.php?title=MediaWiki:Sidebar&amp;amp;action=edit| Edit Navigation&lt;br /&gt;
&lt;br /&gt;
* TOOLBOX&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Wartung_%26_Service&amp;diff=2043</id>
		<title>Wartung &amp; Service</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Wartung_%26_Service&amp;diff=2043"/>
				<updated>2017-04-19T10:29:03Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{languages&lt;br /&gt;
|de=Wartung &amp;amp; Service&lt;br /&gt;
|en=Maintenance &amp;amp; Service&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
Die Wartung des SRM - Ergometers ist Voraussetzung, um über längere Zeiträume exakte Leistunsgdaten zu erhalten. Daher empfehlen wir vor jeder Messung die Kalibrierung durchzuführen bzw. die Einstellungen zu kontrollieren.&lt;br /&gt;
&lt;br /&gt;
==Batteriewechel beim PowerMeter==&lt;br /&gt;
Nach ca. 1800 Bertiebsstunden sollte die Batterie des PowerMeters gewechselt werden. Dafür müssen Sie den PowerMeter und das PowerControl zu uns schicken. Gleichzeitig mit dem Batterienwechsel werden PowerMeter und PowerControl überprüft und neu kalibriert.&lt;br /&gt;
&lt;br /&gt;
==Austausch Pedale, Lenker, Sattel, Kurbel, PowerMeter und Kettenblatt==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[File:Setup-PowerControl.jpg|thumb|Einstellung der neuen Steigung (Slope) bei Wechsel des PowerMeters]]&lt;br /&gt;
[[File:020-Isokinetic-Gear-Change-53.jpg|thumb|Änderung der Übersetzung im isokinetischen Modus bei Wechsel des Kettenblattes]]&lt;br /&gt;
&lt;br /&gt;
Pedale, Lenker, Sattel können mit konventionellem Werkzeug vom Benutzer selbst getauscht werden. Bei Austausch der Kurbeln ist darauf zu achten, dass die 5 Befestigungsschrauben Kurbel - PowerMeter und die Befestigungsschraube Kurbel - Achse nach erfolgtem Wechsel wieder fest angezogen werden. &lt;br /&gt;
&lt;br /&gt;
Die Kettenblattschrauben ca. mit 8 - 10 Nm, die Kurbel auf die Tretlagerachse mit ca. 40 Nm anziehen. Die Steigung des PowerMeter ändert sich hierbei nicht. Die Nullstelle muss nach der Montage neu eingestellt werden. Sie sollte auch noch anfangs öfter überprüft werden, da sich die Schrauben wärend des Betriebes noch setzen, und sich dadurch die Nullstelle ändern kann.&lt;br /&gt;
&lt;br /&gt;
Beim Einsatz eines anderen PowerMeters muss in der SRMWin - Software die entsprechende neue Steigung (Abgabesignal des PowerMeters in Hz / Nm) eingegeben werden. &lt;br /&gt;
&lt;br /&gt;
Wenn ein Kettenblatt mit einer anderen Zähnezahl (Standardmäßig 53) am PowerMeter eingesetzt wird, muss in der SRMWin - Software die Übersetzung geändert werden, um die gewünschte Tretfrequenz bei den Tests zu erhalten (SRM-Online - Options - Extra - Gearing Isokinetic Mode).&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Kette==&lt;br /&gt;
Die Teile mit dem größten Verschleiß sind die Kette und die Antriebsritzel. Bei häufigem Wechsel der Kette ist der Ritzelverschleiß entsprechend geringer. Die Kette sollte ca. alle 500 Betriebsstunden gegen eine neue getauscht werden. Dazu ist es notwendig, dass die rechte Abdeckhaube des Ergometers entfernt wird. Sie ist mit sechs 5mm Inbusschrauben befestigt. Danach kann die Kette mit einem Nietendrücker geöffnet und gegen eine neue getauscht werden. Hierbei ist es auch möglich, die Indizierung der Schaltung neu einzustellen bzw. zu überprüfen. Im 4. Gang müssen beide roten Markierungen der Schaltungshebel an der Nabe gegenüber stehen. &lt;br /&gt;
Während des Betriebes ist darauf zu achten, dass die Kette nicht trockenläuft und immer ausreichend mit Öl oder Fett geschmiert ist.  &lt;br /&gt;
&lt;br /&gt;
==Pflege des Ergometergehäuses==&lt;br /&gt;
Das Ergometergehäuse sollte mit einem feuchten Lappen und etwas mildem Reinigungsmittel gesäubert werden. Jedoch nicht mit einem starken Lösungsmittel wie Aceton oder Nitroverdünnung. Insbesondere der Schweiß der Athleten sollte nach Belastungsende immer abgewischt werden. Ebenso sollten die Stangen zur Sattel- und Lenkerverstellung immer ausreichend mit Fett geschmiert sein.&lt;br /&gt;
&lt;br /&gt;
==Wartungsintervalle==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; |- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
!style=&amp;quot;width:30%&amp;quot;| Bauteile!! style=&amp;quot;width:30%&amp;quot; | Service&lt;br /&gt;
!style=&amp;quot;width:30%&amp;quot;| Empfohlener Zeitraum&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| SRM - Kurbel und PowerControl|| &lt;br /&gt;
* Batteriewechsel und Kalibrierung des PowerMeters&lt;br /&gt;
* Akkuwechsel und Überprüfung des PowerControl IV&lt;br /&gt;
|| &lt;br /&gt;
* alle 2 Jahre&lt;br /&gt;
* Die SRM - Kurbel und das PowerControl müssen für den Service zu uns eingeschickt werden.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Komplettes Ergometer|| &lt;br /&gt;
* Batteriewechsel, Kalibrierung SRM - Kurbel und PowerControl&lt;br /&gt;
* Service Rohloff (Ölwechsel, etc.)&lt;br /&gt;
* Überprüfung Gertriebe, Lager und Schwungmassen&lt;br /&gt;
* allg. Prüfung Anschlüsse und Kabel&lt;br /&gt;
* Überprüfung mechanische Bauteile Klemmhebel, Sattestütze, Sattelstrebe, Lenkerstrebe,- u. stütze&lt;br /&gt;
* Erneuerung / Austausch Verschleißteile (Kettenblätter, Kette, Lenkerband, evtl. Sattel, etc.)&lt;br /&gt;
* Komplettsäuberung des Ergometers&lt;br /&gt;
* optionales Sandstrahlen und neue Pulverbeschichtung (abhängig vom Zustand des Ergometers )&lt;br /&gt;
* optionales upgrade für die Windows [http://www.srm.de/de/produkte/tretkraftanalyse/ Torque Analyse]&lt;br /&gt;
||&lt;br /&gt;
* alle 4 Jahre&lt;br /&gt;
* Das Ergometer inkl. aller Kabel und Netzteil muss für den 4 jährigen Service zu uns eingeschickt werden&lt;br /&gt;
* wir empfehlern das Ergometer in einer abgeschlossenen Box zu uns zu schicken&lt;br /&gt;
* die Kosten sind abhängig vom Umfang der notwendigen Reparaturen; ein Kostenvoranschlag wird nach Eingang und Untersuchung des Ergometers erstellt&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Handb%C3%BCcher&amp;diff=2042</id>
		<title>Handbücher</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Handb%C3%BCcher&amp;diff=2042"/>
				<updated>2017-02-07T10:10:21Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{languages&lt;br /&gt;
|de=Handbücher&lt;br /&gt;
|en=Manuals&lt;br /&gt;
|cn=Manuals&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
In der folgenden Tabelle finden Sie die verschiedenen Handbücher für das das SRM-Ergometer und für die dazugehörige Torque-Analyse.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot;&lt;br /&gt;
|+ style=&amp;quot;padding-bottom:1em&amp;quot; | Handbücher des SRM-Ergometers &lt;br /&gt;
|- class=&amp;quot;hintergrundfarbe6&amp;quot;&lt;br /&gt;
!style=&amp;quot;width:30%&amp;quot;| Handbuch/Manuals!! style=&amp;quot;width:30%&amp;quot; | Sprache!! style=&amp;quot;width:30%&amp;quot; | Letztes Update&lt;br /&gt;
|-&lt;br /&gt;
| [[Media:Kurzanleitung SRM-Ergometer.pdf|Ergometer Kurzanleitung]] || deutsch&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| April 2013 &lt;br /&gt;
|-&lt;br /&gt;
| [[Media:Short Manual SRM Ergometer.pdf|Ergometer Short Manual]] || englisch&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| September 2013&lt;br /&gt;
|-&lt;br /&gt;
| [[Media:Guida Breve Ergometro SRM.pdf|Guida Breve Ergometro SRM]] || italienisch&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| April 2014&lt;br /&gt;
|-&lt;br /&gt;
| [[Media:SRM 功率自行车快速手册.pdf|SRM 功率自行车快速手册]] || chinesisch&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| April 2014&lt;br /&gt;
|-&lt;br /&gt;
| [[Media:Ergometer_2013_brake-control_documentation(1).pdf|Ergometer Brake Control Documentation]] || englisch&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| Juni 2013&lt;br /&gt;
|-&lt;br /&gt;
| [[Media:2006 SRM User Manual Ergometer, 4th Edition, Andrea Wooles.pdf|Ergometer Complete Manual]] || englisch&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| 2006&lt;br /&gt;
|-&lt;br /&gt;
| [[Media:Manual SRM Torque (06.12.2012), Mirco Smerecnik.pdf|Torque Analysis Manual]] || englisch&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot; class=&amp;quot;hintergrundfarbe5&amp;quot;|  Dezember 2012 &lt;br /&gt;
|-&lt;br /&gt;
| [[Media:SRM-Ergometer, Alternative zum Wingate Test.pdf|SRM-Ergometer, Alternative zum Wingate Test]] || deutsch&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot; class=&amp;quot;hintergrundfarbe5&amp;quot;|  Mai 2013 &lt;br /&gt;
|-&lt;br /&gt;
| [[Media:Activation Point SRM Ethernet Torque Analysis.pdf|Torque Analysis Activation Point setup]] || englisch&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot; class=&amp;quot;hintergrundfarbe5&amp;quot;|  Oktober 2012 &lt;br /&gt;
|-&lt;br /&gt;
| [[Media:Montageanleitung_-_Extra_Torque_Kabel_(SRM_Ergometer).pdf|Montageanleitung Extra Torque Kabel]] || deutsch&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot; class=&amp;quot;hintergrundfarbe5&amp;quot;|  Oktober 2012 &lt;br /&gt;
|-&lt;br /&gt;
| [[Media:Assembly_instruction_-_Extra_Torque_Cable_(SRM_Ergometer).pdf|Assembly instruction - Extra Torque Cable]] || englisch&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot; class=&amp;quot;hintergrundfarbe5&amp;quot;|  Oktober 2012 &lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=File:Montageanleitung_-_Extra_Torque_Kabel_(SRM_Ergometer).pdf&amp;diff=2041</id>
		<title>File:Montageanleitung - Extra Torque Kabel (SRM Ergometer).pdf</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=File:Montageanleitung_-_Extra_Torque_Kabel_(SRM_Ergometer).pdf&amp;diff=2041"/>
				<updated>2017-02-07T10:06:55Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=File:Assembly_instruction_-_Extra_Torque_Cable_(SRM_Ergometer).pdf&amp;diff=2040</id>
		<title>File:Assembly instruction - Extra Torque Cable (SRM Ergometer).pdf</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=File:Assembly_instruction_-_Extra_Torque_Cable_(SRM_Ergometer).pdf&amp;diff=2040"/>
				<updated>2017-02-07T10:06:34Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Mechanische_Grundlagen&amp;diff=2039</id>
		<title>Mechanische Grundlagen</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Mechanische_Grundlagen&amp;diff=2039"/>
				<updated>2016-10-19T17:31:36Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: /* Sitzposition des Athleten */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{languages&lt;br /&gt;
|de=Mechanische Grundlagen&lt;br /&gt;
|en=Mechanical Fundamentals&lt;br /&gt;
|cn=Mechanical Fundamentals&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
Die mechanischen Einstellungen des SRM - Ergometers erlauben u.a. die individuelle Sitzposition der Fahrers zu finden oder die bekannte Sitzposition vom Rad zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
 File:SRM-Sattelstütze-(Bezeichnungen).jpg|Bezeichnungen Sattelstütze und Lineale &lt;br /&gt;
 File:Lenker-(Bezeichnungen).jpg|Bezeichnungen Lenker und Lineale&lt;br /&gt;
 File:SRM-Ergometer-02.jpg|Das SRM - Powermeter Wissenschaft&lt;br /&gt;
 File:Verlängerbare_Kurbel_1.jpg|Verlängerbare Kurbel 1 &lt;br /&gt;
 File:Verlängerbare_Kurbel_2.jpg|Verlängerbare Kurbel 2&lt;br /&gt;
 File:022-Montage-Schwungmassen.jpg|Wechsel der Schwungmassen&lt;br /&gt;
 File:021-Getriebe-Schwungmassen.jpg|Abbildung mit kleiner Schwungmasse u. entsprechenden Spacern&lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Sitzposition des Athleten ==&lt;br /&gt;
&lt;br /&gt;
[[File:SRM-Sattelstütze-(Bezeichnungen).jpg|thumb|Bezeichnungen Sattelstütze und Lineale]]&lt;br /&gt;
[[File:Lenker-(Bezeichnungen).jpg|thumb|Bezeichnungen Lenker und Lineale]]&lt;br /&gt;
&lt;br /&gt;
Überprüfen Sie vor jeder Leistungsdiagnostik die eingestellte Sitzposition des Athleten. &lt;br /&gt;
&lt;br /&gt;
Die Sitzposition des Sportlers kann durch Verschieben der horizontalen und vertikalen Sattel- und Lenkerstreben und - stützen erfolgen. Dazu müssen die Klemmhebel geöffnet werden. An den seitlich angebrachten Linealen kann eine einmal gefundene Position des Sportlers immer wieder exakt reproduzierbar eingestellt werden. Dabei sollte darauf geachtet werden, dass die verschiebbaren Streben etwas gefettet sind, um eine zu starke Reibung in den Führungsbuchsen zu vermeiden. &lt;br /&gt;
&lt;br /&gt;
Wenn die horizontalen und vertikalen Klemmhebel korrekt eingestellt sind lassen sich die Streben und Stützen bei gelöstem Klemmhebel leicht verschieben. Falls das Spiel an der horizontalen Sattel- bzw. Lenkerstrebe zu groß ist, ziehen Sie bitte die dem Klemmhebel gegenüberliegenden 5 mm Innensechskantschrauben leicht an. Dadurch lässt sich das Spiel reduzieren.&lt;br /&gt;
&lt;br /&gt;
* '''Waagerechte Positionsveränderung des Sattels'''&lt;br /&gt;
: Das Lineal auf der Sattelstrebe gibt den Abstand von der Tretlagerachse Mitte bis zur Sattelspitze wieder. Der Abstand kann dann an der linken Seite der Sattelstreben in cm abgelesen werden.&lt;br /&gt;
: Sobald die Position des Sattels auf der Sattelstütze verändert wird passen allerdings die Abstände mit den den eingeklebeten Linealen nicht mehr überein. Dann müssen die Abstände auf den Linealen manuell korrigiert werden oder evtl. neue Lineale eingeklebt werden.    &lt;br /&gt;
&lt;br /&gt;
* '''Senkrechte Positionsveränderung des Sattels'''&lt;br /&gt;
* '''Waagerechte Positionsveränderung des Lenkers'''&lt;br /&gt;
* '''Senkrechte Positionsveränderung des Lenkers'''&lt;br /&gt;
&lt;br /&gt;
* '''Verlängerbare Kurbel'''&lt;br /&gt;
: Die verlängerbare Kurbel hat runde Markierungen alle 2,5 mm und alle 10 mm eine Linie. Wenn das Stahlteil der Kurbel komplett in der Aluminiumkurbel eingefahren ist, haben Sie eine min. Länge von 150 mm. Ist die Kurbel komplett herausgezogen ist die maximale Länge 190 mm. Bevor die Kurbel verstellt werden kann, müssen Sie die beiden 5 mm Inbusschrauben mind. 1 Umdrehung öffnen (gegen den Uhrzeigersinn).&lt;br /&gt;
:Nachdem Sie die Kurbel auf die richtige Kurbellänge eingestellt haben, ziehen Sie bitte beide Inbusschrauben gleichmäßig mit einem max. Drehmoment von 10 Nm an, damit sie sich beim Fahren nicht lösen können. Stellen Sie ebenfalls sicher, dass sie sich in einem Abstand von 2,5 mm befinden. Sie können dies feststellen, wenn die Justierfeder (zwischen den Inbusschrauben liegend) in die Löcher des Stahlteils der Kurbel einrastet. Dies ist wichtig, da beide Inbusschrauben an ihren Enden Fixierspitzen haben, die in die Löcher greifen um die Position genau zu bestimmen. Bitte entfernen oder verstellen Sie niemals die Justierfeder!&lt;br /&gt;
:Es ist ebenfalls wichtig, von Zeit zu Zeit ein wenig Fett auf den Stahlteil der Kurbel zu schmieren um es vor Schweiß zu schützen und die Leichtgängigkeit zu bewahren.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
 File:SRM-Ergometer-02.jpg|Das SRM - Powermeter Wissenschaft&lt;br /&gt;
 File:Verlängerbare_Kurbel_1.jpg|Verlängerbare Kurbel 1&lt;br /&gt;
 File:Verlängerbare_Kurbel_2.jpg|Verlängerbare Kurbel 2&lt;br /&gt;
&amp;lt;/gallery&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Aufgaben des Getriebes und der Schwungmassen==&lt;br /&gt;
[[File:022-Montage-Schwungmassen.jpg|thumb|Wechsel der Schwungmassen]]&lt;br /&gt;
[[File:021-Getriebe-Schwungmassen.jpg|thumb|Abbildung mit kleiner Schwungmasse u. entsprechenden Spacern]]&lt;br /&gt;
&lt;br /&gt;
Das Schaltgetriebe erfüllt zwei Aufgaben:&lt;br /&gt;
# Es hilft bei der Simulierung des Massenträgheitsmomentes des Radfahrers.&lt;br /&gt;
# Es dient zur Veränderung der Tretfrequenz bei isokinetischen Tests, ohne die gerade aktive Vorgabedatei ändern zu müssen.&lt;br /&gt;
&lt;br /&gt;
Das Massenträgheitsmoment des Atheleten beim Radfahren ist in erster Linie dafür verantwortlich, dass der Tretzyklus beim Radfahren eine annähernd konstante Winkelgeschwindigkeit aufweist, obwohl das Drehmoment (Leistung) des Radfahrers in vertikaler Stellung der Kurbeln fast bei Null liegt. Hätte das Ergometer keine Schwungmasse, würde bei hoher Leistung bei dieser Kurbelstellung die Tretfrequenz fast auf Null abfallen, der Tritt würde dann sehr ´unrund´ werden.&lt;br /&gt;
&lt;br /&gt;
In den folgenden Abbildungen ist angegeben, wie man mit Hilfe der beiden Schwungmassen und dem Getriebe eine annähernd dem Fahrergewicht identische Schwungenergie einstellen kann.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
 File:023-Kinetic-Energy-Cyclist.jpg|Kinetische Energie des Fahrers inkl. Rad&lt;br /&gt;
 File:024-Kinetic-Energy-Flymasse.jpg|Kinetische Energie des SRM-Ergometers und der Schwungscheiben&lt;br /&gt;
 File:025-Transmission-Ratio-Ergometer.jpg|Getriebeübersetzung des SRM-Ergometers&lt;br /&gt;
&amp;lt;/gallery&amp;gt; &lt;br /&gt;
&lt;br /&gt;
Die kinetische Energie des Radfahrers ist dabei gleich der Rotationsenergie der Schwungscheiben.&lt;br /&gt;
&lt;br /&gt;
Die Kinetische Energie des Radfahrers ist: E = v² x m/2&lt;br /&gt;
&lt;br /&gt;
Es muss allerdings bei leistungsdiagnostischen Untersuchungen berücksichtigt werden, dass die Regelschwankung auf den einzelnen Leistungsstufen linear zur Schwungmassengröße ansteigt. Will man eine möglichst geringe Regelschwankung, fährt man ohne Zusatzmasse im 3. oder 4. Gang am besten. &lt;br /&gt;
Es ist auch hilfreich auf eine kleinere Übersetzung zu schalten, wenn die Leerlaufreibung des Ergometers im 3. oder 4. Gang höher als die Anfangsleistung beim Stufentest ist. Im 4. Gang ist die Leerlaufreibung bei 90 Umdrehungen etwa 80 Watt, im 1. Gang etwa 50 Watt. Demzufolge ist es nicht möglich Leistungswerte unter 50 Watt zu regeln.&lt;br /&gt;
&lt;br /&gt;
Die Schwungscheiben können nach Entfernen des linken Ergometerdeckels durch Lösen der messingfarbenen Sicherungsmutter einfach gewechselt werden. Es reicht, die Sicherungsmutter handfest anzuziehen.&lt;br /&gt;
&lt;br /&gt;
Die kleine Schwungscheibe wiegt 4,6 kg, die große Schwungscheibe 9,1 kg.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- [[en:Mechanical Fundamentals]] --&amp;gt;&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Mechanische_Grundlagen&amp;diff=2038</id>
		<title>Mechanische Grundlagen</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Mechanische_Grundlagen&amp;diff=2038"/>
				<updated>2016-10-19T17:30:33Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{languages&lt;br /&gt;
|de=Mechanische Grundlagen&lt;br /&gt;
|en=Mechanical Fundamentals&lt;br /&gt;
|cn=Mechanical Fundamentals&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
Die mechanischen Einstellungen des SRM - Ergometers erlauben u.a. die individuelle Sitzposition der Fahrers zu finden oder die bekannte Sitzposition vom Rad zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
 File:SRM-Sattelstütze-(Bezeichnungen).jpg|Bezeichnungen Sattelstütze und Lineale &lt;br /&gt;
 File:Lenker-(Bezeichnungen).jpg|Bezeichnungen Lenker und Lineale&lt;br /&gt;
 File:SRM-Ergometer-02.jpg|Das SRM - Powermeter Wissenschaft&lt;br /&gt;
 File:Verlängerbare_Kurbel_1.jpg|Verlängerbare Kurbel 1 &lt;br /&gt;
 File:Verlängerbare_Kurbel_2.jpg|Verlängerbare Kurbel 2&lt;br /&gt;
 File:022-Montage-Schwungmassen.jpg|Wechsel der Schwungmassen&lt;br /&gt;
 File:021-Getriebe-Schwungmassen.jpg|Abbildung mit kleiner Schwungmasse u. entsprechenden Spacern&lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Sitzposition des Athleten ==&lt;br /&gt;
&lt;br /&gt;
[[File:SRM-Sattelstütze-(Bezeichnungen).jpg|Bezeichnungen Sattelstütze und Lineale]]&lt;br /&gt;
[[File:Lenker-(Bezeichnungen).jpg|Bezeichnungen Lenker und Lineale]]&lt;br /&gt;
&lt;br /&gt;
Überprüfen Sie vor jeder Leistungsdiagnostik die eingestellte Sitzposition des Athleten. &lt;br /&gt;
&lt;br /&gt;
Die Sitzposition des Sportlers kann durch Verschieben der horizontalen und vertikalen Sattel- und Lenkerstreben und - stützen erfolgen. Dazu müssen die Klemmhebel geöffnet werden. An den seitlich angebrachten Linealen kann eine einmal gefundene Position des Sportlers immer wieder exakt reproduzierbar eingestellt werden. Dabei sollte darauf geachtet werden, dass die verschiebbaren Streben etwas gefettet sind, um eine zu starke Reibung in den Führungsbuchsen zu vermeiden. &lt;br /&gt;
&lt;br /&gt;
Wenn die horizontalen und vertikalen Klemmhebel korrekt eingestellt sind lassen sich die Streben und Stützen bei gelöstem Klemmhebel leicht verschieben. Falls das Spiel an der horizontalen Sattel- bzw. Lenkerstrebe zu groß ist, ziehen Sie bitte die dem Klemmhebel gegenüberliegenden 5 mm Innensechskantschrauben leicht an. Dadurch lässt sich das Spiel reduzieren.&lt;br /&gt;
&lt;br /&gt;
* '''Waagerechte Positionsveränderung des Sattels'''&lt;br /&gt;
: Das Lineal auf der Sattelstrebe gibt den Abstand von der Tretlagerachse Mitte bis zur Sattelspitze wieder. Der Abstand kann dann an der linken Seite der Sattelstreben in cm abgelesen werden.&lt;br /&gt;
: Sobald die Position des Sattels auf der Sattelstütze verändert wird passen allerdings die Abstände mit den den eingeklebeten Linealen nicht mehr überein. Dann müssen die Abstände auf den Linealen manuell korrigiert werden oder evtl. neue Lineale eingeklebt werden.    &lt;br /&gt;
&lt;br /&gt;
* '''Senkrechte Positionsveränderung des Sattels'''&lt;br /&gt;
* '''Waagerechte Positionsveränderung des Lenkers'''&lt;br /&gt;
* '''Senkrechte Positionsveränderung des Lenkers'''&lt;br /&gt;
&lt;br /&gt;
* '''Verlängerbare Kurbel'''&lt;br /&gt;
: Die verlängerbare Kurbel hat runde Markierungen alle 2,5 mm und alle 10 mm eine Linie. Wenn das Stahlteil der Kurbel komplett in der Aluminiumkurbel eingefahren ist, haben Sie eine min. Länge von 150 mm. Ist die Kurbel komplett herausgezogen ist die maximale Länge 190 mm. Bevor die Kurbel verstellt werden kann, müssen Sie die beiden 5 mm Inbusschrauben mind. 1 Umdrehung öffnen (gegen den Uhrzeigersinn).&lt;br /&gt;
:Nachdem Sie die Kurbel auf die richtige Kurbellänge eingestellt haben, ziehen Sie bitte beide Inbusschrauben gleichmäßig mit einem max. Drehmoment von 10 Nm an, damit sie sich beim Fahren nicht lösen können. Stellen Sie ebenfalls sicher, dass sie sich in einem Abstand von 2,5 mm befinden. Sie können dies feststellen, wenn die Justierfeder (zwischen den Inbusschrauben liegend) in die Löcher des Stahlteils der Kurbel einrastet. Dies ist wichtig, da beide Inbusschrauben an ihren Enden Fixierspitzen haben, die in die Löcher greifen um die Position genau zu bestimmen. Bitte entfernen oder verstellen Sie niemals die Justierfeder!&lt;br /&gt;
:Es ist ebenfalls wichtig, von Zeit zu Zeit ein wenig Fett auf den Stahlteil der Kurbel zu schmieren um es vor Schweiß zu schützen und die Leichtgängigkeit zu bewahren.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
 File:SRM-Ergometer-02.jpg|Das SRM - Powermeter Wissenschaft&lt;br /&gt;
 File:Verlängerbare_Kurbel_1.jpg|Verlängerbare Kurbel 1&lt;br /&gt;
 File:Verlängerbare_Kurbel_2.jpg|Verlängerbare Kurbel 2&lt;br /&gt;
&amp;lt;/gallery&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Aufgaben des Getriebes und der Schwungmassen==&lt;br /&gt;
[[File:022-Montage-Schwungmassen.jpg|thumb|Wechsel der Schwungmassen]]&lt;br /&gt;
[[File:021-Getriebe-Schwungmassen.jpg|thumb|Abbildung mit kleiner Schwungmasse u. entsprechenden Spacern]]&lt;br /&gt;
&lt;br /&gt;
Das Schaltgetriebe erfüllt zwei Aufgaben:&lt;br /&gt;
# Es hilft bei der Simulierung des Massenträgheitsmomentes des Radfahrers.&lt;br /&gt;
# Es dient zur Veränderung der Tretfrequenz bei isokinetischen Tests, ohne die gerade aktive Vorgabedatei ändern zu müssen.&lt;br /&gt;
&lt;br /&gt;
Das Massenträgheitsmoment des Atheleten beim Radfahren ist in erster Linie dafür verantwortlich, dass der Tretzyklus beim Radfahren eine annähernd konstante Winkelgeschwindigkeit aufweist, obwohl das Drehmoment (Leistung) des Radfahrers in vertikaler Stellung der Kurbeln fast bei Null liegt. Hätte das Ergometer keine Schwungmasse, würde bei hoher Leistung bei dieser Kurbelstellung die Tretfrequenz fast auf Null abfallen, der Tritt würde dann sehr ´unrund´ werden.&lt;br /&gt;
&lt;br /&gt;
In den folgenden Abbildungen ist angegeben, wie man mit Hilfe der beiden Schwungmassen und dem Getriebe eine annähernd dem Fahrergewicht identische Schwungenergie einstellen kann.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
 File:023-Kinetic-Energy-Cyclist.jpg|Kinetische Energie des Fahrers inkl. Rad&lt;br /&gt;
 File:024-Kinetic-Energy-Flymasse.jpg|Kinetische Energie des SRM-Ergometers und der Schwungscheiben&lt;br /&gt;
 File:025-Transmission-Ratio-Ergometer.jpg|Getriebeübersetzung des SRM-Ergometers&lt;br /&gt;
&amp;lt;/gallery&amp;gt; &lt;br /&gt;
&lt;br /&gt;
Die kinetische Energie des Radfahrers ist dabei gleich der Rotationsenergie der Schwungscheiben.&lt;br /&gt;
&lt;br /&gt;
Die Kinetische Energie des Radfahrers ist: E = v² x m/2&lt;br /&gt;
&lt;br /&gt;
Es muss allerdings bei leistungsdiagnostischen Untersuchungen berücksichtigt werden, dass die Regelschwankung auf den einzelnen Leistungsstufen linear zur Schwungmassengröße ansteigt. Will man eine möglichst geringe Regelschwankung, fährt man ohne Zusatzmasse im 3. oder 4. Gang am besten. &lt;br /&gt;
Es ist auch hilfreich auf eine kleinere Übersetzung zu schalten, wenn die Leerlaufreibung des Ergometers im 3. oder 4. Gang höher als die Anfangsleistung beim Stufentest ist. Im 4. Gang ist die Leerlaufreibung bei 90 Umdrehungen etwa 80 Watt, im 1. Gang etwa 50 Watt. Demzufolge ist es nicht möglich Leistungswerte unter 50 Watt zu regeln.&lt;br /&gt;
&lt;br /&gt;
Die Schwungscheiben können nach Entfernen des linken Ergometerdeckels durch Lösen der messingfarbenen Sicherungsmutter einfach gewechselt werden. Es reicht, die Sicherungsmutter handfest anzuziehen.&lt;br /&gt;
&lt;br /&gt;
Die kleine Schwungscheibe wiegt 4,6 kg, die große Schwungscheibe 9,1 kg.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- [[en:Mechanical Fundamentals]] --&amp;gt;&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Mechanische_Grundlagen&amp;diff=2037</id>
		<title>Mechanische Grundlagen</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Mechanische_Grundlagen&amp;diff=2037"/>
				<updated>2016-10-19T17:19:39Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: /* Sitzposition des Athleten */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{languages&lt;br /&gt;
|de=Mechanische Grundlagen&lt;br /&gt;
|en=Mechanical Fundamentals&lt;br /&gt;
|cn=Mechanical Fundamentals&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
Die mechanischen Einstellungen des SRM - Ergometers erlauben u.a. die individuelle Sitzposition der Fahrers zu finden oder die bekannte Sitzposition vom Rad zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
 File:SRM-Sattelstütze-(Bezeichnungen).jpg|Bezeichnungen Sattelstütze und Lineale &lt;br /&gt;
 File:Lenker-(Bezeichnungen).jpg|Bezeichnungen Lenker und Lineale&lt;br /&gt;
 File:SRM-Ergometer-02.jpg|Das SRM - Powermeter Wissenschaft&lt;br /&gt;
 File:Verlängerbare_Kurbel_1.jpg|Verlängerbare Kurbel 1 &lt;br /&gt;
 File:Verlängerbare_Kurbel_2.jpg|Verlängerbare Kurbel 2&lt;br /&gt;
 File:022-Montage-Schwungmassen.jpg|Wechsel der Schwungmassen&lt;br /&gt;
 File:021-Getriebe-Schwungmassen.jpg|Abbildung mit kleiner Schwungmasse u. entsprechenden Spacern&lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Sitzposition des Athleten ==&lt;br /&gt;
&lt;br /&gt;
[[File:022-Montage-Schwungmassen.jpg|thumb|Wechsel der Schwungmassen]]&lt;br /&gt;
[[File:021-Getriebe-Schwungmassen.jpg|thumb|Abbildung mit kleiner Schwungmasse u. entsprechenden Spacern]]&lt;br /&gt;
&lt;br /&gt;
Überprüfen Sie vor jeder Leistungsdiagnostik die eingestellte Sitzposition des Athleten. &lt;br /&gt;
&lt;br /&gt;
Die Sitzposition des Sportlers kann durch Verschieben der horizontalen und vertikalen Sattel- und Lenkerstreben und - stützen erfolgen. Dazu müssen die Klemmhebel geöffnet werden. An den seitlich angebrachten Linealen kann eine einmal gefundene Position des Sportlers immer wieder exakt reproduzierbar eingestellt werden. Dabei sollte darauf geachtet werden, dass die verschiebbaren Streben etwas gefettet sind, um eine zu starke Reibung in den Führungsbuchsen zu vermeiden. &lt;br /&gt;
&lt;br /&gt;
Wenn die horizontalen und vertikalen Klemmhebel korrekt eingestellt sind lassen sich die Streben und Stützen bei gelöstem Klemmhebel leicht verschieben. Falls das Spiel an der horizontalen Sattel- bzw. Lenkerstrebe zu groß ist, ziehen Sie bitte die dem Klemmhebel gegenüberliegenden 5 mm Innensechskantschrauben leicht an. Dadurch lässt sich das Spiel reduzieren.&lt;br /&gt;
&lt;br /&gt;
* '''Waagerechte Positionsveränderung des Sattels'''&lt;br /&gt;
: Das Lineal auf der Sattelstrebe gibt den Abstand von der Tretlagerachse Mitte bis zur Sattelspitze wieder. Der Abstand kann dann an der linken Seite der Sattelstreben in cm abgelesen werden.&lt;br /&gt;
: Sobald die Position des Sattels auf der Sattelstütze verändert wird passen allerdings die Abstände mit den den eingeklebeten Linealen nicht mehr überein. Dann müssen die Abstände auf den Linealen manuell korrigiert werden oder evtl. neue Lineale eingeklebt werden.    &lt;br /&gt;
&lt;br /&gt;
* '''Senkrechte Positionsveränderung des Sattels'''&lt;br /&gt;
* '''Waagerechte Positionsveränderung des Lenkers'''&lt;br /&gt;
* '''Senkrechte Positionsveränderung des Lenkers'''&lt;br /&gt;
&lt;br /&gt;
* '''Verlängerbare Kurbel'''&lt;br /&gt;
: Die verlängerbare Kurbel hat runde Markierungen alle 2,5 mm und alle 10 mm eine Linie. Wenn das Stahlteil der Kurbel komplett in der Aluminiumkurbel eingefahren ist, haben Sie eine min. Länge von 150 mm. Ist die Kurbel komplett herausgezogen ist die maximale Länge 190 mm. Bevor die Kurbel verstellt werden kann, müssen Sie die beiden 5 mm Inbusschrauben mind. 1 Umdrehung öffnen (gegen den Uhrzeigersinn).&lt;br /&gt;
:Nachdem Sie die Kurbel auf die richtige Kurbellänge eingestellt haben, ziehen Sie bitte beide Inbusschrauben gleichmäßig mit einem max. Drehmoment von 10 Nm an, damit sie sich beim Fahren nicht lösen können. Stellen Sie ebenfalls sicher, dass sie sich in einem Abstand von 2,5 mm befinden. Sie können dies feststellen, wenn die Justierfeder (zwischen den Inbusschrauben liegend) in die Löcher des Stahlteils der Kurbel einrastet. Dies ist wichtig, da beide Inbusschrauben an ihren Enden Fixierspitzen haben, die in die Löcher greifen um die Position genau zu bestimmen. Bitte entfernen oder verstellen Sie niemals die Justierfeder!&lt;br /&gt;
:Es ist ebenfalls wichtig, von Zeit zu Zeit ein wenig Fett auf den Stahlteil der Kurbel zu schmieren um es vor Schweiß zu schützen und die Leichtgängigkeit zu bewahren.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
 File:SRM-Ergometer-02.jpg|Das SRM - Powermeter Wissenschaft&lt;br /&gt;
 File:Verlängerbare_Kurbel_1.jpg|Verlängerbare Kurbel 1&lt;br /&gt;
 File:Verlängerbare_Kurbel_2.jpg|Verlängerbare Kurbel 2&lt;br /&gt;
&amp;lt;/gallery&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Aufgaben des Getriebes und der Schwungmassen==&lt;br /&gt;
[[File:022-Montage-Schwungmassen.jpg|thumb|Wechsel der Schwungmassen]]&lt;br /&gt;
[[File:021-Getriebe-Schwungmassen.jpg|thumb|Abbildung mit kleiner Schwungmasse u. entsprechenden Spacern]]&lt;br /&gt;
&lt;br /&gt;
Das Schaltgetriebe erfüllt zwei Aufgaben:&lt;br /&gt;
# Es hilft bei der Simulierung des Massenträgheitsmomentes des Radfahrers.&lt;br /&gt;
# Es dient zur Veränderung der Tretfrequenz bei isokinetischen Tests, ohne die gerade aktive Vorgabedatei ändern zu müssen.&lt;br /&gt;
&lt;br /&gt;
Das Massenträgheitsmoment des Atheleten beim Radfahren ist in erster Linie dafür verantwortlich, dass der Tretzyklus beim Radfahren eine annähernd konstante Winkelgeschwindigkeit aufweist, obwohl das Drehmoment (Leistung) des Radfahrers in vertikaler Stellung der Kurbeln fast bei Null liegt. Hätte das Ergometer keine Schwungmasse, würde bei hoher Leistung bei dieser Kurbelstellung die Tretfrequenz fast auf Null abfallen, der Tritt würde dann sehr ´unrund´ werden.&lt;br /&gt;
&lt;br /&gt;
In den folgenden Abbildungen ist angegeben, wie man mit Hilfe der beiden Schwungmassen und dem Getriebe eine annähernd dem Fahrergewicht identische Schwungenergie einstellen kann.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
 File:023-Kinetic-Energy-Cyclist.jpg|Kinetische Energie des Fahrers inkl. Rad&lt;br /&gt;
 File:024-Kinetic-Energy-Flymasse.jpg|Kinetische Energie des SRM-Ergometers und der Schwungscheiben&lt;br /&gt;
 File:025-Transmission-Ratio-Ergometer.jpg|Getriebeübersetzung des SRM-Ergometers&lt;br /&gt;
&amp;lt;/gallery&amp;gt; &lt;br /&gt;
&lt;br /&gt;
Die kinetische Energie des Radfahrers ist dabei gleich der Rotationsenergie der Schwungscheiben.&lt;br /&gt;
&lt;br /&gt;
Die Kinetische Energie des Radfahrers ist: E = v² x m/2&lt;br /&gt;
&lt;br /&gt;
Es muss allerdings bei leistungsdiagnostischen Untersuchungen berücksichtigt werden, dass die Regelschwankung auf den einzelnen Leistungsstufen linear zur Schwungmassengröße ansteigt. Will man eine möglichst geringe Regelschwankung, fährt man ohne Zusatzmasse im 3. oder 4. Gang am besten. &lt;br /&gt;
Es ist auch hilfreich auf eine kleinere Übersetzung zu schalten, wenn die Leerlaufreibung des Ergometers im 3. oder 4. Gang höher als die Anfangsleistung beim Stufentest ist. Im 4. Gang ist die Leerlaufreibung bei 90 Umdrehungen etwa 80 Watt, im 1. Gang etwa 50 Watt. Demzufolge ist es nicht möglich Leistungswerte unter 50 Watt zu regeln.&lt;br /&gt;
&lt;br /&gt;
Die Schwungscheiben können nach Entfernen des linken Ergometerdeckels durch Lösen der messingfarbenen Sicherungsmutter einfach gewechselt werden. Es reicht, die Sicherungsmutter handfest anzuziehen.&lt;br /&gt;
&lt;br /&gt;
Die kleine Schwungscheibe wiegt 4,6 kg, die große Schwungscheibe 9,1 kg.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- [[en:Mechanical Fundamentals]] --&amp;gt;&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Mechanische_Grundlagen&amp;diff=2036</id>
		<title>Mechanische Grundlagen</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Mechanische_Grundlagen&amp;diff=2036"/>
				<updated>2016-10-19T17:18:45Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{languages&lt;br /&gt;
|de=Mechanische Grundlagen&lt;br /&gt;
|en=Mechanical Fundamentals&lt;br /&gt;
|cn=Mechanical Fundamentals&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
Die mechanischen Einstellungen des SRM - Ergometers erlauben u.a. die individuelle Sitzposition der Fahrers zu finden oder die bekannte Sitzposition vom Rad zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
 File:SRM-Sattelstütze-(Bezeichnungen).jpg|Bezeichnungen Sattelstütze und Lineale &lt;br /&gt;
 File:Lenker-(Bezeichnungen).jpg|Bezeichnungen Lenker und Lineale&lt;br /&gt;
 File:SRM-Ergometer-02.jpg|Das SRM - Powermeter Wissenschaft&lt;br /&gt;
 File:Verlängerbare_Kurbel_1.jpg|Verlängerbare Kurbel 1 &lt;br /&gt;
 File:Verlängerbare_Kurbel_2.jpg|Verlängerbare Kurbel 2&lt;br /&gt;
 File:022-Montage-Schwungmassen.jpg|Wechsel der Schwungmassen&lt;br /&gt;
 File:021-Getriebe-Schwungmassen.jpg|Abbildung mit kleiner Schwungmasse u. entsprechenden Spacern&lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Sitzposition des Athleten ==&lt;br /&gt;
&lt;br /&gt;
Überprüfen Sie vor jeder Leistungsdiagnostik die eingestellte Sitzposition des Athleten. &lt;br /&gt;
&lt;br /&gt;
Die Sitzposition des Sportlers kann durch Verschieben der horizontalen und vertikalen Sattel- und Lenkerstreben und - stützen erfolgen. Dazu müssen die Klemmhebel geöffnet werden. An den seitlich angebrachten Linealen kann eine einmal gefundene Position des Sportlers immer wieder exakt reproduzierbar eingestellt werden. Dabei sollte darauf geachtet werden, dass die verschiebbaren Streben etwas gefettet sind, um eine zu starke Reibung in den Führungsbuchsen zu vermeiden. &lt;br /&gt;
&lt;br /&gt;
Wenn die horizontalen und vertikalen Klemmhebel korrekt eingestellt sind lassen sich die Streben und Stützen bei gelöstem Klemmhebel leicht verschieben. Falls das Spiel an der horizontalen Sattel- bzw. Lenkerstrebe zu groß ist, ziehen Sie bitte die dem Klemmhebel gegenüberliegenden 5 mm Innensechskantschrauben leicht an. Dadurch lässt sich das Spiel reduzieren.&lt;br /&gt;
&lt;br /&gt;
* '''Waagerechte Positionsveränderung des Sattels'''&lt;br /&gt;
: Das Lineal auf der Sattelstrebe gibt den Abstand von der Tretlagerachse Mitte bis zur Sattelspitze wieder. Der Abstand kann dann an der linken Seite der Sattelstreben in cm abgelesen werden.&lt;br /&gt;
: Sobald die Position des Sattels auf der Sattelstütze verändert wird passen allerdings die Abstände mit den den eingeklebeten Linealen nicht mehr überein. Dann müssen die Abstände auf den Linealen manuell korrigiert werden oder evtl. neue Lineale eingeklebt werden.    &lt;br /&gt;
&lt;br /&gt;
* '''Senkrechte Positionsveränderung des Sattels'''&lt;br /&gt;
* '''Waagerechte Positionsveränderung des Lenkers'''&lt;br /&gt;
* '''Senkrechte Positionsveränderung des Lenkers'''&lt;br /&gt;
&lt;br /&gt;
* '''Verlängerbare Kurbel'''&lt;br /&gt;
: Die verlängerbare Kurbel hat runde Markierungen alle 2,5 mm und alle 10 mm eine Linie. Wenn das Stahlteil der Kurbel komplett in der Aluminiumkurbel eingefahren ist, haben Sie eine min. Länge von 150 mm. Ist die Kurbel komplett herausgezogen ist die maximale Länge 190 mm. Bevor die Kurbel verstellt werden kann, müssen Sie die beiden 5 mm Inbusschrauben mind. 1 Umdrehung öffnen (gegen den Uhrzeigersinn).&lt;br /&gt;
:Nachdem Sie die Kurbel auf die richtige Kurbellänge eingestellt haben, ziehen Sie bitte beide Inbusschrauben gleichmäßig mit einem max. Drehmoment von 10 Nm an, damit sie sich beim Fahren nicht lösen können. Stellen Sie ebenfalls sicher, dass sie sich in einem Abstand von 2,5 mm befinden. Sie können dies feststellen, wenn die Justierfeder (zwischen den Inbusschrauben liegend) in die Löcher des Stahlteils der Kurbel einrastet. Dies ist wichtig, da beide Inbusschrauben an ihren Enden Fixierspitzen haben, die in die Löcher greifen um die Position genau zu bestimmen. Bitte entfernen oder verstellen Sie niemals die Justierfeder!&lt;br /&gt;
:Es ist ebenfalls wichtig, von Zeit zu Zeit ein wenig Fett auf den Stahlteil der Kurbel zu schmieren um es vor Schweiß zu schützen und die Leichtgängigkeit zu bewahren.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
 File:SRM-Ergometer-02.jpg|Das SRM - Powermeter Wissenschaft&lt;br /&gt;
 File:Verlängerbare_Kurbel_1.jpg|Verlängerbare Kurbel 1&lt;br /&gt;
 File:Verlängerbare_Kurbel_2.jpg|Verlängerbare Kurbel 2&lt;br /&gt;
&amp;lt;/gallery&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Aufgaben des Getriebes und der Schwungmassen==&lt;br /&gt;
[[File:022-Montage-Schwungmassen.jpg|thumb|Wechsel der Schwungmassen]]&lt;br /&gt;
[[File:021-Getriebe-Schwungmassen.jpg|thumb|Abbildung mit kleiner Schwungmasse u. entsprechenden Spacern]]&lt;br /&gt;
&lt;br /&gt;
Das Schaltgetriebe erfüllt zwei Aufgaben:&lt;br /&gt;
# Es hilft bei der Simulierung des Massenträgheitsmomentes des Radfahrers.&lt;br /&gt;
# Es dient zur Veränderung der Tretfrequenz bei isokinetischen Tests, ohne die gerade aktive Vorgabedatei ändern zu müssen.&lt;br /&gt;
&lt;br /&gt;
Das Massenträgheitsmoment des Atheleten beim Radfahren ist in erster Linie dafür verantwortlich, dass der Tretzyklus beim Radfahren eine annähernd konstante Winkelgeschwindigkeit aufweist, obwohl das Drehmoment (Leistung) des Radfahrers in vertikaler Stellung der Kurbeln fast bei Null liegt. Hätte das Ergometer keine Schwungmasse, würde bei hoher Leistung bei dieser Kurbelstellung die Tretfrequenz fast auf Null abfallen, der Tritt würde dann sehr ´unrund´ werden.&lt;br /&gt;
&lt;br /&gt;
In den folgenden Abbildungen ist angegeben, wie man mit Hilfe der beiden Schwungmassen und dem Getriebe eine annähernd dem Fahrergewicht identische Schwungenergie einstellen kann.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
 File:023-Kinetic-Energy-Cyclist.jpg|Kinetische Energie des Fahrers inkl. Rad&lt;br /&gt;
 File:024-Kinetic-Energy-Flymasse.jpg|Kinetische Energie des SRM-Ergometers und der Schwungscheiben&lt;br /&gt;
 File:025-Transmission-Ratio-Ergometer.jpg|Getriebeübersetzung des SRM-Ergometers&lt;br /&gt;
&amp;lt;/gallery&amp;gt; &lt;br /&gt;
&lt;br /&gt;
Die kinetische Energie des Radfahrers ist dabei gleich der Rotationsenergie der Schwungscheiben.&lt;br /&gt;
&lt;br /&gt;
Die Kinetische Energie des Radfahrers ist: E = v² x m/2&lt;br /&gt;
&lt;br /&gt;
Es muss allerdings bei leistungsdiagnostischen Untersuchungen berücksichtigt werden, dass die Regelschwankung auf den einzelnen Leistungsstufen linear zur Schwungmassengröße ansteigt. Will man eine möglichst geringe Regelschwankung, fährt man ohne Zusatzmasse im 3. oder 4. Gang am besten. &lt;br /&gt;
Es ist auch hilfreich auf eine kleinere Übersetzung zu schalten, wenn die Leerlaufreibung des Ergometers im 3. oder 4. Gang höher als die Anfangsleistung beim Stufentest ist. Im 4. Gang ist die Leerlaufreibung bei 90 Umdrehungen etwa 80 Watt, im 1. Gang etwa 50 Watt. Demzufolge ist es nicht möglich Leistungswerte unter 50 Watt zu regeln.&lt;br /&gt;
&lt;br /&gt;
Die Schwungscheiben können nach Entfernen des linken Ergometerdeckels durch Lösen der messingfarbenen Sicherungsmutter einfach gewechselt werden. Es reicht, die Sicherungsmutter handfest anzuziehen.&lt;br /&gt;
&lt;br /&gt;
Die kleine Schwungscheibe wiegt 4,6 kg, die große Schwungscheibe 9,1 kg.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- [[en:Mechanical Fundamentals]] --&amp;gt;&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Mechanische_Grundlagen&amp;diff=2035</id>
		<title>Mechanische Grundlagen</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Mechanische_Grundlagen&amp;diff=2035"/>
				<updated>2016-10-19T17:17:23Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: /* Sitzposition des Athleten */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{languages&lt;br /&gt;
|de=Mechanische Grundlagen&lt;br /&gt;
|en=Mechanical Fundamentals&lt;br /&gt;
|cn=Mechanical Fundamentals&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
Die mechanischen Einstellungen des SRM - Ergometers erlauben u.a. die individuelle Sitzposition der Fahrers zu finden oder die bekannte Sitzposition vom Rad zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
 File:SRM-Sattelstütze-(Bezeichnungen).jpg|Bezeichnungen Sattelstütze und Lineale &lt;br /&gt;
 File:Lenker-(Bezeichnungen).jpg|Bezeichnungen Lenker und Lineale&lt;br /&gt;
 File:Verlängerbare_Kurbel_1.jpg|Verlängerbare Kurbel 1 &lt;br /&gt;
 File:Verlängerbare_Kurbel_2.jpg|Verlängerbare Kurbel 2&lt;br /&gt;
 File:022-Montage-Schwungmassen.jpg|Wechsel der Schwungmassen&lt;br /&gt;
 File:021-Getriebe-Schwungmassen.jpg|Abbildung mit kleiner Schwungmasse u. entsprechenden Spacern&lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Sitzposition des Athleten ==&lt;br /&gt;
[[File:SRM-Sattelstütze-(Bezeichnungen).jpg|thumb|Bezeichnungen Sattelstütze und Lineale]]&lt;br /&gt;
[[File:Lenker-(Bezeichnungen).jpg|thumb|Bezeichnungen Lenker und Lineale]]&lt;br /&gt;
[[File:SRM-Ergometer-02.jpg|thumb|Das SRM - Powermeter Wissenschaft]]&lt;br /&gt;
[[File:Verlängerbare_Kurbel_1.jpg|thumb|Verlängerbare Kurbel 1]]&lt;br /&gt;
[[File:Verlängerbare_Kurbel_2.jpg|thumb|Verlängerbare Kurbel 2]]&lt;br /&gt;
&lt;br /&gt;
Überprüfen Sie vor jeder Leistungsdiagnostik die eingestellte Sitzposition des Athleten. &lt;br /&gt;
&lt;br /&gt;
Die Sitzposition des Sportlers kann durch Verschieben der horizontalen und vertikalen Sattel- und Lenkerstreben und - stützen erfolgen. Dazu müssen die Klemmhebel geöffnet werden. An den seitlich angebrachten Linealen kann eine einmal gefundene Position des Sportlers immer wieder exakt reproduzierbar eingestellt werden. Dabei sollte darauf geachtet werden, dass die verschiebbaren Streben etwas gefettet sind, um eine zu starke Reibung in den Führungsbuchsen zu vermeiden. &lt;br /&gt;
&lt;br /&gt;
Wenn die horizontalen und vertikalen Klemmhebel korrekt eingestellt sind lassen sich die Streben und Stützen bei gelöstem Klemmhebel leicht verschieben. Falls das Spiel an der horizontalen Sattel- bzw. Lenkerstrebe zu groß ist, ziehen Sie bitte die dem Klemmhebel gegenüberliegenden 5 mm Innensechskantschrauben leicht an. Dadurch lässt sich das Spiel reduzieren.&lt;br /&gt;
&lt;br /&gt;
* '''Waagerechte Positionsveränderung des Sattels'''&lt;br /&gt;
: Das Lineal auf der Sattelstrebe gibt den Abstand von der Tretlagerachse Mitte bis zur Sattelspitze wieder. Der Abstand kann dann an der linken Seite der Sattelstreben in cm abgelesen werden.&lt;br /&gt;
: Sobald die Position des Sattels auf der Sattelstütze verändert wird passen allerdings die Abstände mit den den eingeklebeten Linealen nicht mehr überein. Dann müssen die Abstände auf den Linealen manuell korrigiert werden oder evtl. neue Lineale eingeklebt werden.    &lt;br /&gt;
&lt;br /&gt;
* '''Senkrechte Positionsveränderung des Sattels'''&lt;br /&gt;
* '''Waagerechte Positionsveränderung des Lenkers'''&lt;br /&gt;
* '''Senkrechte Positionsveränderung des Lenkers'''&lt;br /&gt;
&lt;br /&gt;
* '''Verlängerbare Kurbel'''&lt;br /&gt;
: Die verlängerbare Kurbel hat runde Markierungen alle 2,5 mm und alle 10 mm eine Linie. Wenn das Stahlteil der Kurbel komplett in der Aluminiumkurbel eingefahren ist, haben Sie eine min. Länge von 150 mm. Ist die Kurbel komplett herausgezogen ist die maximale Länge 190 mm. Bevor die Kurbel verstellt werden kann, müssen Sie die beiden 5 mm Inbusschrauben mind. 1 Umdrehung öffnen (gegen den Uhrzeigersinn).&lt;br /&gt;
:Nachdem Sie die Kurbel auf die richtige Kurbellänge eingestellt haben, ziehen Sie bitte beide Inbusschrauben gleichmäßig mit einem max. Drehmoment von 10 Nm an, damit sie sich beim Fahren nicht lösen können. Stellen Sie ebenfalls sicher, dass sie sich in einem Abstand von 2,5 mm befinden. Sie können dies feststellen, wenn die Justierfeder (zwischen den Inbusschrauben liegend) in die Löcher des Stahlteils der Kurbel einrastet. Dies ist wichtig, da beide Inbusschrauben an ihren Enden Fixierspitzen haben, die in die Löcher greifen um die Position genau zu bestimmen. Bitte entfernen oder verstellen Sie niemals die Justierfeder!&lt;br /&gt;
:Es ist ebenfalls wichtig, von Zeit zu Zeit ein wenig Fett auf den Stahlteil der Kurbel zu schmieren um es vor Schweiß zu schützen und die Leichtgängigkeit zu bewahren.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
 File:SRM-Ergometer-02.jpg|Das SRM - Powermeter Wissenschaft&lt;br /&gt;
 File:Verlängerbare_Kurbel_1.jpg|Verlängerbare Kurbel 1&lt;br /&gt;
 File:Verlängerbare_Kurbel_2.jpg|Verlängerbare Kurbel 2&lt;br /&gt;
&amp;lt;/gallery&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Aufgaben des Getriebes und der Schwungmassen==&lt;br /&gt;
[[File:022-Montage-Schwungmassen.jpg|thumb|Wechsel der Schwungmassen]]&lt;br /&gt;
[[File:021-Getriebe-Schwungmassen.jpg|thumb|Abbildung mit kleiner Schwungmasse u. entsprechenden Spacern]]&lt;br /&gt;
&lt;br /&gt;
Das Schaltgetriebe erfüllt zwei Aufgaben:&lt;br /&gt;
# Es hilft bei der Simulierung des Massenträgheitsmomentes des Radfahrers.&lt;br /&gt;
# Es dient zur Veränderung der Tretfrequenz bei isokinetischen Tests, ohne die gerade aktive Vorgabedatei ändern zu müssen.&lt;br /&gt;
&lt;br /&gt;
Das Massenträgheitsmoment des Atheleten beim Radfahren ist in erster Linie dafür verantwortlich, dass der Tretzyklus beim Radfahren eine annähernd konstante Winkelgeschwindigkeit aufweist, obwohl das Drehmoment (Leistung) des Radfahrers in vertikaler Stellung der Kurbeln fast bei Null liegt. Hätte das Ergometer keine Schwungmasse, würde bei hoher Leistung bei dieser Kurbelstellung die Tretfrequenz fast auf Null abfallen, der Tritt würde dann sehr ´unrund´ werden.&lt;br /&gt;
&lt;br /&gt;
In den folgenden Abbildungen ist angegeben, wie man mit Hilfe der beiden Schwungmassen und dem Getriebe eine annähernd dem Fahrergewicht identische Schwungenergie einstellen kann.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
 File:023-Kinetic-Energy-Cyclist.jpg|Kinetische Energie des Fahrers inkl. Rad&lt;br /&gt;
 File:024-Kinetic-Energy-Flymasse.jpg|Kinetische Energie des SRM-Ergometers und der Schwungscheiben&lt;br /&gt;
 File:025-Transmission-Ratio-Ergometer.jpg|Getriebeübersetzung des SRM-Ergometers&lt;br /&gt;
&amp;lt;/gallery&amp;gt; &lt;br /&gt;
&lt;br /&gt;
Die kinetische Energie des Radfahrers ist dabei gleich der Rotationsenergie der Schwungscheiben.&lt;br /&gt;
&lt;br /&gt;
Die Kinetische Energie des Radfahrers ist: E = v² x m/2&lt;br /&gt;
&lt;br /&gt;
Es muss allerdings bei leistungsdiagnostischen Untersuchungen berücksichtigt werden, dass die Regelschwankung auf den einzelnen Leistungsstufen linear zur Schwungmassengröße ansteigt. Will man eine möglichst geringe Regelschwankung, fährt man ohne Zusatzmasse im 3. oder 4. Gang am besten. &lt;br /&gt;
Es ist auch hilfreich auf eine kleinere Übersetzung zu schalten, wenn die Leerlaufreibung des Ergometers im 3. oder 4. Gang höher als die Anfangsleistung beim Stufentest ist. Im 4. Gang ist die Leerlaufreibung bei 90 Umdrehungen etwa 80 Watt, im 1. Gang etwa 50 Watt. Demzufolge ist es nicht möglich Leistungswerte unter 50 Watt zu regeln.&lt;br /&gt;
&lt;br /&gt;
Die Schwungscheiben können nach Entfernen des linken Ergometerdeckels durch Lösen der messingfarbenen Sicherungsmutter einfach gewechselt werden. Es reicht, die Sicherungsmutter handfest anzuziehen.&lt;br /&gt;
&lt;br /&gt;
Die kleine Schwungscheibe wiegt 4,6 kg, die große Schwungscheibe 9,1 kg.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- [[en:Mechanical Fundamentals]] --&amp;gt;&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Mechanische_Grundlagen&amp;diff=2034</id>
		<title>Mechanische Grundlagen</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Mechanische_Grundlagen&amp;diff=2034"/>
				<updated>2016-10-19T17:16:26Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: /* Sitzposition des Athleten */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{languages&lt;br /&gt;
|de=Mechanische Grundlagen&lt;br /&gt;
|en=Mechanical Fundamentals&lt;br /&gt;
|cn=Mechanical Fundamentals&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
Die mechanischen Einstellungen des SRM - Ergometers erlauben u.a. die individuelle Sitzposition der Fahrers zu finden oder die bekannte Sitzposition vom Rad zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
 File:SRM-Sattelstütze-(Bezeichnungen).jpg|Bezeichnungen Sattelstütze und Lineale &lt;br /&gt;
 File:Lenker-(Bezeichnungen).jpg|Bezeichnungen Lenker und Lineale&lt;br /&gt;
 File:Verlängerbare_Kurbel_1.jpg|Verlängerbare Kurbel 1 &lt;br /&gt;
 File:Verlängerbare_Kurbel_2.jpg|Verlängerbare Kurbel 2&lt;br /&gt;
 File:022-Montage-Schwungmassen.jpg|Wechsel der Schwungmassen&lt;br /&gt;
 File:021-Getriebe-Schwungmassen.jpg|Abbildung mit kleiner Schwungmasse u. entsprechenden Spacern&lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Sitzposition des Athleten ==&lt;br /&gt;
[[File:SRM-Sattelstütze-(Bezeichnungen).jpg|thumb|Bezeichnungen Sattelstütze und Lineale]]&lt;br /&gt;
[[File:Lenker-(Bezeichnungen).jpg|thumb|Bezeichnungen Lenker und Lineale]]&lt;br /&gt;
[[File:Verlängerbare_Kurbel_1.jpg|thumb|Verlängerbare Kurbel 1]]&lt;br /&gt;
[[File:Verlängerbare_Kurbel_2.jpg|thumb|Verlängerbare Kurbel 2]]&lt;br /&gt;
&lt;br /&gt;
Überprüfen Sie vor jeder Leistungsdiagnostik die eingestellte Sitzposition des Athleten. &lt;br /&gt;
&lt;br /&gt;
Die Sitzposition des Sportlers kann durch Verschieben der horizontalen und vertikalen Sattel- und Lenkerstreben und - stützen erfolgen. Dazu müssen die Klemmhebel geöffnet werden. An den seitlich angebrachten Linealen kann eine einmal gefundene Position des Sportlers immer wieder exakt reproduzierbar eingestellt werden. Dabei sollte darauf geachtet werden, dass die verschiebbaren Streben etwas gefettet sind, um eine zu starke Reibung in den Führungsbuchsen zu vermeiden. &lt;br /&gt;
&lt;br /&gt;
Wenn die horizontalen und vertikalen Klemmhebel korrekt eingestellt sind lassen sich die Streben und Stützen bei gelöstem Klemmhebel leicht verschieben. Falls das Spiel an der horizontalen Sattel- bzw. Lenkerstrebe zu groß ist, ziehen Sie bitte die dem Klemmhebel gegenüberliegenden 5 mm Innensechskantschrauben leicht an. Dadurch lässt sich das Spiel reduzieren.&lt;br /&gt;
&lt;br /&gt;
* '''Waagerechte Positionsveränderung des Sattels'''&lt;br /&gt;
: Das Lineal auf der Sattelstrebe gibt den Abstand von der Tretlagerachse Mitte bis zur Sattelspitze wieder. Der Abstand kann dann an der linken Seite der Sattelstreben in cm abgelesen werden.&lt;br /&gt;
: Sobald die Position des Sattels auf der Sattelstütze verändert wird passen allerdings die Abstände mit den den eingeklebeten Linealen nicht mehr überein. Dann müssen die Abstände auf den Linealen manuell korrigiert werden oder evtl. neue Lineale eingeklebt werden.    &lt;br /&gt;
&lt;br /&gt;
* '''Senkrechte Positionsveränderung des Sattels'''&lt;br /&gt;
* '''Waagerechte Positionsveränderung des Lenkers'''&lt;br /&gt;
* '''Senkrechte Positionsveränderung des Lenkers'''&lt;br /&gt;
&lt;br /&gt;
* '''Verlängerbare Kurbel'''&lt;br /&gt;
: Die verlängerbare Kurbel hat runde Markierungen alle 2,5 mm und alle 10 mm eine Linie. Wenn das Stahlteil der Kurbel komplett in der Aluminiumkurbel eingefahren ist, haben Sie eine min. Länge von 150 mm. Ist die Kurbel komplett herausgezogen ist die maximale Länge 190 mm. Bevor die Kurbel verstellt werden kann, müssen Sie die beiden 5 mm Inbusschrauben mind. 1 Umdrehung öffnen (gegen den Uhrzeigersinn).&lt;br /&gt;
:Nachdem Sie die Kurbel auf die richtige Kurbellänge eingestellt haben, ziehen Sie bitte beide Inbusschrauben gleichmäßig mit einem max. Drehmoment von 10 Nm an, damit sie sich beim Fahren nicht lösen können. Stellen Sie ebenfalls sicher, dass sie sich in einem Abstand von 2,5 mm befinden. Sie können dies feststellen, wenn die Justierfeder (zwischen den Inbusschrauben liegend) in die Löcher des Stahlteils der Kurbel einrastet. Dies ist wichtig, da beide Inbusschrauben an ihren Enden Fixierspitzen haben, die in die Löcher greifen um die Position genau zu bestimmen. Bitte entfernen oder verstellen Sie niemals die Justierfeder!&lt;br /&gt;
:Es ist ebenfalls wichtig, von Zeit zu Zeit ein wenig Fett auf den Stahlteil der Kurbel zu schmieren um es vor Schweiß zu schützen und die Leichtgängigkeit zu bewahren.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
 File:SRM-Ergometer-02.jpg|Das SRM - Powermeter Wissenschaft&lt;br /&gt;
 File:Verlängerbare_Kurbel_1.jpg|Verlängerbare Kurbel 1&lt;br /&gt;
 File:Verlängerbare_Kurbel_2.jpg|Verlängerbare Kurbel 2&lt;br /&gt;
&amp;lt;/gallery&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Aufgaben des Getriebes und der Schwungmassen==&lt;br /&gt;
[[File:022-Montage-Schwungmassen.jpg|thumb|Wechsel der Schwungmassen]]&lt;br /&gt;
[[File:021-Getriebe-Schwungmassen.jpg|thumb|Abbildung mit kleiner Schwungmasse u. entsprechenden Spacern]]&lt;br /&gt;
&lt;br /&gt;
Das Schaltgetriebe erfüllt zwei Aufgaben:&lt;br /&gt;
# Es hilft bei der Simulierung des Massenträgheitsmomentes des Radfahrers.&lt;br /&gt;
# Es dient zur Veränderung der Tretfrequenz bei isokinetischen Tests, ohne die gerade aktive Vorgabedatei ändern zu müssen.&lt;br /&gt;
&lt;br /&gt;
Das Massenträgheitsmoment des Atheleten beim Radfahren ist in erster Linie dafür verantwortlich, dass der Tretzyklus beim Radfahren eine annähernd konstante Winkelgeschwindigkeit aufweist, obwohl das Drehmoment (Leistung) des Radfahrers in vertikaler Stellung der Kurbeln fast bei Null liegt. Hätte das Ergometer keine Schwungmasse, würde bei hoher Leistung bei dieser Kurbelstellung die Tretfrequenz fast auf Null abfallen, der Tritt würde dann sehr ´unrund´ werden.&lt;br /&gt;
&lt;br /&gt;
In den folgenden Abbildungen ist angegeben, wie man mit Hilfe der beiden Schwungmassen und dem Getriebe eine annähernd dem Fahrergewicht identische Schwungenergie einstellen kann.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
 File:023-Kinetic-Energy-Cyclist.jpg|Kinetische Energie des Fahrers inkl. Rad&lt;br /&gt;
 File:024-Kinetic-Energy-Flymasse.jpg|Kinetische Energie des SRM-Ergometers und der Schwungscheiben&lt;br /&gt;
 File:025-Transmission-Ratio-Ergometer.jpg|Getriebeübersetzung des SRM-Ergometers&lt;br /&gt;
&amp;lt;/gallery&amp;gt; &lt;br /&gt;
&lt;br /&gt;
Die kinetische Energie des Radfahrers ist dabei gleich der Rotationsenergie der Schwungscheiben.&lt;br /&gt;
&lt;br /&gt;
Die Kinetische Energie des Radfahrers ist: E = v² x m/2&lt;br /&gt;
&lt;br /&gt;
Es muss allerdings bei leistungsdiagnostischen Untersuchungen berücksichtigt werden, dass die Regelschwankung auf den einzelnen Leistungsstufen linear zur Schwungmassengröße ansteigt. Will man eine möglichst geringe Regelschwankung, fährt man ohne Zusatzmasse im 3. oder 4. Gang am besten. &lt;br /&gt;
Es ist auch hilfreich auf eine kleinere Übersetzung zu schalten, wenn die Leerlaufreibung des Ergometers im 3. oder 4. Gang höher als die Anfangsleistung beim Stufentest ist. Im 4. Gang ist die Leerlaufreibung bei 90 Umdrehungen etwa 80 Watt, im 1. Gang etwa 50 Watt. Demzufolge ist es nicht möglich Leistungswerte unter 50 Watt zu regeln.&lt;br /&gt;
&lt;br /&gt;
Die Schwungscheiben können nach Entfernen des linken Ergometerdeckels durch Lösen der messingfarbenen Sicherungsmutter einfach gewechselt werden. Es reicht, die Sicherungsmutter handfest anzuziehen.&lt;br /&gt;
&lt;br /&gt;
Die kleine Schwungscheibe wiegt 4,6 kg, die große Schwungscheibe 9,1 kg.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- [[en:Mechanical Fundamentals]] --&amp;gt;&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Mechanische_Grundlagen&amp;diff=2033</id>
		<title>Mechanische Grundlagen</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Mechanische_Grundlagen&amp;diff=2033"/>
				<updated>2016-10-19T17:15:43Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: /* Sitzposition des Athleten */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{languages&lt;br /&gt;
|de=Mechanische Grundlagen&lt;br /&gt;
|en=Mechanical Fundamentals&lt;br /&gt;
|cn=Mechanical Fundamentals&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
Die mechanischen Einstellungen des SRM - Ergometers erlauben u.a. die individuelle Sitzposition der Fahrers zu finden oder die bekannte Sitzposition vom Rad zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
 File:SRM-Sattelstütze-(Bezeichnungen).jpg|Bezeichnungen Sattelstütze und Lineale &lt;br /&gt;
 File:Lenker-(Bezeichnungen).jpg|Bezeichnungen Lenker und Lineale&lt;br /&gt;
 File:Verlängerbare_Kurbel_1.jpg|Verlängerbare Kurbel 1 &lt;br /&gt;
 File:Verlängerbare_Kurbel_2.jpg|Verlängerbare Kurbel 2&lt;br /&gt;
 File:022-Montage-Schwungmassen.jpg|Wechsel der Schwungmassen&lt;br /&gt;
 File:021-Getriebe-Schwungmassen.jpg|Abbildung mit kleiner Schwungmasse u. entsprechenden Spacern&lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Sitzposition des Athleten ==&lt;br /&gt;
[[File:SRM-Sattelstütze-(Bezeichnungen).jpg|thumb|Bezeichnungen Sattelstütze und Lineale]]&lt;br /&gt;
[[File:Lenker-(Bezeichnungen).jpg|thumb|Bezeichnungen Lenker und Lineale]]&lt;br /&gt;
[[File:Verlängerbare_Kurbel_1.jpg|thumb|Verlängerbare Kurbel 1]]&lt;br /&gt;
[[File:Verlängerbare_Kurbel_2.jpg|thumb|Verlängerbare Kurbel 2]]&lt;br /&gt;
&lt;br /&gt;
Überprüfen Sie vor jeder Leistungsdiagnostik die eingestellte Sitzposition des Athleten. &lt;br /&gt;
&lt;br /&gt;
Die Sitzposition des Sportlers kann durch Verschieben der horizontalen und vertikalen Sattel- und Lenkerstreben und - stützen erfolgen. Dazu müssen die Klemmhebel geöffnet werden. An den seitlich angebrachten Linealen kann eine einmal gefundene Position des Sportlers immer wieder exakt reproduzierbar eingestellt werden. Dabei sollte darauf geachtet werden, dass die verschiebbaren Streben etwas gefettet sind, um eine zu starke Reibung in den Führungsbuchsen zu vermeiden. &lt;br /&gt;
&lt;br /&gt;
Wenn die horizontalen und vertikalen Klemmhebel korrekt eingestellt sind lassen sich die Streben und Stützen bei gelöstem Klemmhebel leicht verschieben. Falls das Spiel an der horizontalen Sattel- bzw. Lenkerstrebe zu groß ist, ziehen Sie bitte die dem Klemmhebel gegenüberliegenden 5 mm Innensechskantschrauben leicht an. Dadurch lässt sich das Spiel reduzieren.&lt;br /&gt;
&lt;br /&gt;
* '''Waagerechte Positionsveränderung des Sattels'''&lt;br /&gt;
: Das Lineal auf der Sattelstrebe gibt den Abstand von der Tretlagerachse Mitte bis zur Sattelspitze wieder. Der Abstand kann dann an der linken Seite der Sattelstreben in cm abgelesen werden.&lt;br /&gt;
: Sobald die Position des Sattels auf der Sattelstütze verändert wird passen allerdings die Abstände mit den den eingeklebeten Linealen nicht mehr überein. Dann müssen die Abstände auf den Linealen manuell korrigiert werden oder evtl. neue Lineale eingeklebt werden.    &lt;br /&gt;
&lt;br /&gt;
* '''Senkrechte Positionsveränderung des Sattels'''&lt;br /&gt;
* '''Waagerechte Positionsveränderung des Lenkers'''&lt;br /&gt;
* '''Senkrechte Positionsveränderung des Lenkers'''&lt;br /&gt;
&lt;br /&gt;
* '''Verlängerbare Kurbel'''&lt;br /&gt;
: Die verlängerbare Kurbel hat runde Markierungen alle 2,5 mm und alle 10 mm eine Linie. Wenn das Stahlteil der Kurbel komplett in der Aluminiumkurbel eingefahren ist, haben Sie eine min. Länge von 150 mm. Ist die Kurbel komplett herausgezogen ist die maximale Länge 190 mm. Bevor die Kurbel verstellt werden kann, müssen Sie die beiden 5 mm Inbusschrauben mind. 1 Umdrehung öffnen (gegen den Uhrzeigersinn).&lt;br /&gt;
:Nachdem Sie die Kurbel auf die richtige Kurbellänge eingestellt haben, ziehen Sie bitte beide Inbusschrauben gleichmäßig mit einem max. Drehmoment von 10 Nm an, damit sie sich beim Fahren nicht lösen können. Stellen Sie ebenfalls sicher, dass sie sich in einem Abstand von 2,5 mm befinden. Sie können dies feststellen, wenn die Justierfeder (zwischen den Inbusschrauben liegend) in die Löcher des Stahlteils der Kurbel einrastet. Dies ist wichtig, da beide Inbusschrauben an ihren Enden Fixierspitzen haben, die in die Löcher greifen um die Position genau zu bestimmen. Bitte entfernen oder verstellen Sie niemals die Justierfeder!&lt;br /&gt;
:Es ist ebenfalls wichtig, von Zeit zu Zeit ein wenig Fett auf den Stahlteil der Kurbel zu schmieren um es vor Schweiß zu schützen und die Leichtgängigkeit zu bewahren.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
 File:File:SRM-Ergometer-02.jpg|Das SRM - Powermeter Wissenschaft&lt;br /&gt;
 File:Verlängerbare_Kurbel_1.jpg|thumb|Verlängerbare Kurbel 1&lt;br /&gt;
 File:Verlängerbare_Kurbel_2.jpg|thumb|Verlängerbare Kurbel 2&lt;br /&gt;
&amp;lt;/gallery&amp;gt; &lt;br /&gt;
&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Aufgaben des Getriebes und der Schwungmassen==&lt;br /&gt;
[[File:022-Montage-Schwungmassen.jpg|thumb|Wechsel der Schwungmassen]]&lt;br /&gt;
[[File:021-Getriebe-Schwungmassen.jpg|thumb|Abbildung mit kleiner Schwungmasse u. entsprechenden Spacern]]&lt;br /&gt;
&lt;br /&gt;
Das Schaltgetriebe erfüllt zwei Aufgaben:&lt;br /&gt;
# Es hilft bei der Simulierung des Massenträgheitsmomentes des Radfahrers.&lt;br /&gt;
# Es dient zur Veränderung der Tretfrequenz bei isokinetischen Tests, ohne die gerade aktive Vorgabedatei ändern zu müssen.&lt;br /&gt;
&lt;br /&gt;
Das Massenträgheitsmoment des Atheleten beim Radfahren ist in erster Linie dafür verantwortlich, dass der Tretzyklus beim Radfahren eine annähernd konstante Winkelgeschwindigkeit aufweist, obwohl das Drehmoment (Leistung) des Radfahrers in vertikaler Stellung der Kurbeln fast bei Null liegt. Hätte das Ergometer keine Schwungmasse, würde bei hoher Leistung bei dieser Kurbelstellung die Tretfrequenz fast auf Null abfallen, der Tritt würde dann sehr ´unrund´ werden.&lt;br /&gt;
&lt;br /&gt;
In den folgenden Abbildungen ist angegeben, wie man mit Hilfe der beiden Schwungmassen und dem Getriebe eine annähernd dem Fahrergewicht identische Schwungenergie einstellen kann.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
 File:023-Kinetic-Energy-Cyclist.jpg|Kinetische Energie des Fahrers inkl. Rad&lt;br /&gt;
 File:024-Kinetic-Energy-Flymasse.jpg|Kinetische Energie des SRM-Ergometers und der Schwungscheiben&lt;br /&gt;
 File:025-Transmission-Ratio-Ergometer.jpg|Getriebeübersetzung des SRM-Ergometers&lt;br /&gt;
&amp;lt;/gallery&amp;gt; &lt;br /&gt;
&lt;br /&gt;
Die kinetische Energie des Radfahrers ist dabei gleich der Rotationsenergie der Schwungscheiben.&lt;br /&gt;
&lt;br /&gt;
Die Kinetische Energie des Radfahrers ist: E = v² x m/2&lt;br /&gt;
&lt;br /&gt;
Es muss allerdings bei leistungsdiagnostischen Untersuchungen berücksichtigt werden, dass die Regelschwankung auf den einzelnen Leistungsstufen linear zur Schwungmassengröße ansteigt. Will man eine möglichst geringe Regelschwankung, fährt man ohne Zusatzmasse im 3. oder 4. Gang am besten. &lt;br /&gt;
Es ist auch hilfreich auf eine kleinere Übersetzung zu schalten, wenn die Leerlaufreibung des Ergometers im 3. oder 4. Gang höher als die Anfangsleistung beim Stufentest ist. Im 4. Gang ist die Leerlaufreibung bei 90 Umdrehungen etwa 80 Watt, im 1. Gang etwa 50 Watt. Demzufolge ist es nicht möglich Leistungswerte unter 50 Watt zu regeln.&lt;br /&gt;
&lt;br /&gt;
Die Schwungscheiben können nach Entfernen des linken Ergometerdeckels durch Lösen der messingfarbenen Sicherungsmutter einfach gewechselt werden. Es reicht, die Sicherungsmutter handfest anzuziehen.&lt;br /&gt;
&lt;br /&gt;
Die kleine Schwungscheibe wiegt 4,6 kg, die große Schwungscheibe 9,1 kg.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- [[en:Mechanical Fundamentals]] --&amp;gt;&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Mechanische_Grundlagen&amp;diff=2032</id>
		<title>Mechanische Grundlagen</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Mechanische_Grundlagen&amp;diff=2032"/>
				<updated>2016-10-19T17:14:04Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: /* Sitzposition des Athleten */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{languages&lt;br /&gt;
|de=Mechanische Grundlagen&lt;br /&gt;
|en=Mechanical Fundamentals&lt;br /&gt;
|cn=Mechanical Fundamentals&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
Die mechanischen Einstellungen des SRM - Ergometers erlauben u.a. die individuelle Sitzposition der Fahrers zu finden oder die bekannte Sitzposition vom Rad zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
 File:SRM-Sattelstütze-(Bezeichnungen).jpg|Bezeichnungen Sattelstütze und Lineale &lt;br /&gt;
 File:Lenker-(Bezeichnungen).jpg|Bezeichnungen Lenker und Lineale&lt;br /&gt;
 File:Verlängerbare_Kurbel_1.jpg|Verlängerbare Kurbel 1 &lt;br /&gt;
 File:Verlängerbare_Kurbel_2.jpg|Verlängerbare Kurbel 2&lt;br /&gt;
 File:022-Montage-Schwungmassen.jpg|Wechsel der Schwungmassen&lt;br /&gt;
 File:021-Getriebe-Schwungmassen.jpg|Abbildung mit kleiner Schwungmasse u. entsprechenden Spacern&lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Sitzposition des Athleten ==&lt;br /&gt;
[[File:SRM-Sattelstütze-(Bezeichnungen).jpg|thumb|Bezeichnungen Sattelstütze und Lineale]]&lt;br /&gt;
[[File:Lenker-(Bezeichnungen).jpg|thumb|Bezeichnungen Lenker und Lineale]]&lt;br /&gt;
[[File:Verlängerbare_Kurbel_1.jpg|thumb|Verlängerbare Kurbel 1]]&lt;br /&gt;
[[File:Verlängerbare_Kurbel_2.jpg|thumb|Verlängerbare Kurbel 2]]&lt;br /&gt;
&lt;br /&gt;
Überprüfen Sie vor jeder Leistungsdiagnostik die eingestellte Sitzposition des Athleten. &lt;br /&gt;
&lt;br /&gt;
Die Sitzposition des Sportlers kann durch Verschieben der horizontalen und vertikalen Sattel- und Lenkerstreben und - stützen erfolgen. Dazu müssen die Klemmhebel geöffnet werden. An den seitlich angebrachten Linealen kann eine einmal gefundene Position des Sportlers immer wieder exakt reproduzierbar eingestellt werden. Dabei sollte darauf geachtet werden, dass die verschiebbaren Streben etwas gefettet sind, um eine zu starke Reibung in den Führungsbuchsen zu vermeiden. &lt;br /&gt;
&lt;br /&gt;
Wenn die horizontalen und vertikalen Klemmhebel korrekt eingestellt sind lassen sich die Streben und Stützen bei gelöstem Klemmhebel leicht verschieben. Falls das Spiel an der horizontalen Sattel- bzw. Lenkerstrebe zu groß ist, ziehen Sie bitte die dem Klemmhebel gegenüberliegenden 5 mm Innensechskantschrauben leicht an. Dadurch lässt sich das Spiel reduzieren.&lt;br /&gt;
&lt;br /&gt;
* '''Waagerechte Positionsveränderung des Sattels'''&lt;br /&gt;
: Das Lineal auf der Sattelstrebe gibt den Abstand von der Tretlagerachse Mitte bis zur Sattelspitze wieder. Der Abstand kann dann an der linken Seite der Sattelstreben in cm abgelesen werden.&lt;br /&gt;
: Sobald die Position des Sattels auf der Sattelstütze verändert wird passen allerdings die Abstände mit den den eingeklebeten Linealen nicht mehr überein. Dann müssen die Abstände auf den Linealen manuell korrigiert werden oder evtl. neue Lineale eingeklebt werden.    &lt;br /&gt;
&lt;br /&gt;
* '''Senkrechte Positionsveränderung des Sattels'''&lt;br /&gt;
* '''Waagerechte Positionsveränderung des Lenkers'''&lt;br /&gt;
* '''Senkrechte Positionsveränderung des Lenkers'''&lt;br /&gt;
&lt;br /&gt;
* '''Verlängerbare Kurbel'''&lt;br /&gt;
: Die verlängerbare Kurbel hat runde Markierungen alle 2,5 mm und alle 10 mm eine Linie. Wenn das Stahlteil der Kurbel komplett in der Aluminiumkurbel eingefahren ist, haben Sie eine min. Länge von 150 mm. Ist die Kurbel komplett herausgezogen ist die maximale Länge 190 mm. Bevor die Kurbel verstellt werden kann, müssen Sie die beiden 5 mm Inbusschrauben mind. 1 Umdrehung öffnen (gegen den Uhrzeigersinn).&lt;br /&gt;
:Nachdem Sie die Kurbel auf die richtige Kurbellänge eingestellt haben, ziehen Sie bitte beide Inbusschrauben gleichmäßig mit einem max. Drehmoment von 10 Nm an, damit sie sich beim Fahren nicht lösen können. Stellen Sie ebenfalls sicher, dass sie sich in einem Abstand von 2,5 mm befinden. Sie können dies feststellen, wenn die Justierfeder (zwischen den Inbusschrauben liegend) in die Löcher des Stahlteils der Kurbel einrastet. Dies ist wichtig, da beide Inbusschrauben an ihren Enden Fixierspitzen haben, die in die Löcher greifen um die Position genau zu bestimmen. Bitte entfernen oder verstellen Sie niemals die Justierfeder!&lt;br /&gt;
:Es ist ebenfalls wichtig, von Zeit zu Zeit ein wenig Fett auf den Stahlteil der Kurbel zu schmieren um es vor Schweiß zu schützen und die Leichtgängigkeit zu bewahren.&lt;br /&gt;
&lt;br /&gt;
 File:SRM-Ergometer-02.jpg|Das SRM - Powermeter Wissenschaft&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Aufgaben des Getriebes und der Schwungmassen==&lt;br /&gt;
[[File:022-Montage-Schwungmassen.jpg|thumb|Wechsel der Schwungmassen]]&lt;br /&gt;
[[File:021-Getriebe-Schwungmassen.jpg|thumb|Abbildung mit kleiner Schwungmasse u. entsprechenden Spacern]]&lt;br /&gt;
&lt;br /&gt;
Das Schaltgetriebe erfüllt zwei Aufgaben:&lt;br /&gt;
# Es hilft bei der Simulierung des Massenträgheitsmomentes des Radfahrers.&lt;br /&gt;
# Es dient zur Veränderung der Tretfrequenz bei isokinetischen Tests, ohne die gerade aktive Vorgabedatei ändern zu müssen.&lt;br /&gt;
&lt;br /&gt;
Das Massenträgheitsmoment des Atheleten beim Radfahren ist in erster Linie dafür verantwortlich, dass der Tretzyklus beim Radfahren eine annähernd konstante Winkelgeschwindigkeit aufweist, obwohl das Drehmoment (Leistung) des Radfahrers in vertikaler Stellung der Kurbeln fast bei Null liegt. Hätte das Ergometer keine Schwungmasse, würde bei hoher Leistung bei dieser Kurbelstellung die Tretfrequenz fast auf Null abfallen, der Tritt würde dann sehr ´unrund´ werden.&lt;br /&gt;
&lt;br /&gt;
In den folgenden Abbildungen ist angegeben, wie man mit Hilfe der beiden Schwungmassen und dem Getriebe eine annähernd dem Fahrergewicht identische Schwungenergie einstellen kann.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
 File:023-Kinetic-Energy-Cyclist.jpg|Kinetische Energie des Fahrers inkl. Rad&lt;br /&gt;
 File:024-Kinetic-Energy-Flymasse.jpg|Kinetische Energie des SRM-Ergometers und der Schwungscheiben&lt;br /&gt;
 File:025-Transmission-Ratio-Ergometer.jpg|Getriebeübersetzung des SRM-Ergometers&lt;br /&gt;
&amp;lt;/gallery&amp;gt; &lt;br /&gt;
&lt;br /&gt;
Die kinetische Energie des Radfahrers ist dabei gleich der Rotationsenergie der Schwungscheiben.&lt;br /&gt;
&lt;br /&gt;
Die Kinetische Energie des Radfahrers ist: E = v² x m/2&lt;br /&gt;
&lt;br /&gt;
Es muss allerdings bei leistungsdiagnostischen Untersuchungen berücksichtigt werden, dass die Regelschwankung auf den einzelnen Leistungsstufen linear zur Schwungmassengröße ansteigt. Will man eine möglichst geringe Regelschwankung, fährt man ohne Zusatzmasse im 3. oder 4. Gang am besten. &lt;br /&gt;
Es ist auch hilfreich auf eine kleinere Übersetzung zu schalten, wenn die Leerlaufreibung des Ergometers im 3. oder 4. Gang höher als die Anfangsleistung beim Stufentest ist. Im 4. Gang ist die Leerlaufreibung bei 90 Umdrehungen etwa 80 Watt, im 1. Gang etwa 50 Watt. Demzufolge ist es nicht möglich Leistungswerte unter 50 Watt zu regeln.&lt;br /&gt;
&lt;br /&gt;
Die Schwungscheiben können nach Entfernen des linken Ergometerdeckels durch Lösen der messingfarbenen Sicherungsmutter einfach gewechselt werden. Es reicht, die Sicherungsmutter handfest anzuziehen.&lt;br /&gt;
&lt;br /&gt;
Die kleine Schwungscheibe wiegt 4,6 kg, die große Schwungscheibe 9,1 kg.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- [[en:Mechanical Fundamentals]] --&amp;gt;&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Internationale_Literatur_zum_SRM-Ergometer&amp;diff=2031</id>
		<title>Internationale Literatur zum SRM-Ergometer</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Internationale_Literatur_zum_SRM-Ergometer&amp;diff=2031"/>
				<updated>2016-09-13T12:15:55Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{languages&lt;br /&gt;
|de=Internationale Literatur zum SRM-Ergometer&lt;br /&gt;
|en=International publications on the SRM Ergometer&lt;br /&gt;
|cn=International publications on the SRM Ergometer&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
In der folgenden Tabelle sind  diverese Sammlungen an Publikationen zu verschiedenen Themen als PDF-Dateien verlinkt.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot;&lt;br /&gt;
|+ style=&amp;quot;padding-bottom:1em&amp;quot; | Publikationen des SRM-Ergometers &lt;br /&gt;
|- class=&amp;quot;hintergrundfarbe6&amp;quot;&lt;br /&gt;
!style=&amp;quot;width:60%&amp;quot;| Publikationen!! style=&amp;quot;width:30%&amp;quot;| Letztes Update&lt;br /&gt;
|-&lt;br /&gt;
| [[Media:SRM_Literatur_13.09.2016.pdf|SRM Scientific Publications]]&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| September 2016 &lt;br /&gt;
|-&lt;br /&gt;
| [[Media:Torque_publications_2015.pdf|Torque Publications]]&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| Januar 2015&lt;br /&gt;
|-&lt;br /&gt;
| [[Media:Eccentric_Chainrings_2015.pdf|Eccentric Chainrings Publications]]&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| April 2015&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
(In der folgenden Tabelle finden Sie aktuelle internationale Literaturstellen in denen das SRM - Ergometer und / oder die SRM - Trainingssysteme für wissenschaftliche Untersuchungen eingesetzt wurden.&lt;br /&gt;
[[Media:SRM_Scientific_Publications_06-2016.pdf|Hier]] finden sie die internationalen Literaturstellen in einem pfd - Dokument zusammengefasst.)&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot;&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|- class=&amp;quot;hintergrundfarbe6&amp;quot;&lt;br /&gt;
!style=&amp;quot;width:30%&amp;quot;| Autor!! style=&amp;quot;width:30%&amp;quot; | Titel!! style=&amp;quot;width:30%&amp;quot; | Publikation&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Abbiss, C.R.; Quod, M.J.; Martin, David T.; Netto, K.J.; Nosaka, K.; Lee, H. et al. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Dynamic pacing strategies during the cycle phase of an Ironman triathlon.  &lt;br /&gt;
|style=&amp;quot;vertical-align:top&amp;quot;| Med Sci Sports Exerc 38 (4), S. 726–734&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Abbiss, C.R.; Quod, M.J.; Levin, G.; Martin, D.T.; Laursen, P.B. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Accuracy of the Velotron ergometer and SRM power meter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 30 (2), S. 107–112.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Abel, T.; Burkett, B.; Schneider, S.; Lindschulten, R.; Strüder, H. K. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The exercise profile of an ultra-long handcycling race: the Styrkeprøven experience.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Spinal Cord 48 (12), S. 894–898.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Antonutto, G.; Capelli, C.; Girardis, M.; Zamparo, P.; di Prampero P.E. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of microgravity on maximal power of lower limbs during very short efforts in humans.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Physiol 86(1), S. 85-92.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Arkesteijn, M.; Hopker, J.; Jobson, S.; Passfield, L. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The Effect of Turbo Trainer Cycling on Pedalling Technique and Cycling Efficiency.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 34 (06), S. 520–525&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M. J.; Gore, C. J.; Burge, C. M.; Clough, M. L.; Bourdon, P. C.; Dobson, G. P.; Hahn, A. G. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Skin-prick blood samples are reliable for estimating Hb mass with the CO-dilution technique.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 79 (6), S. 535–537.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M. J.; Gore, C. J.; Dobson, G. P.; Boston, T. T.; Parisotto, R.; Emslie, K. R. et al. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Simulated moderate altitude elevates serum erythropoietin but does not increase reticulocyte production in well-trained runners.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 81 (5), S. 428–435&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Gore, C. J.; Dobson, G. P.; Hahn, A. G. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| &amp;quot;Live high, train low&amp;quot; does not change the total haemoglobin mass of male endurance athletes sleeping at a simulated altitude of 3000 m for 23 nights. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 80 (5), S. 479–484.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Gore, C. J.; Martin, D. T.; Dobson, G. P.; Hahn, A. G. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of a 12-day &amp;quot;live high, train low&amp;quot; camp on reticulocyte production and haemoglobin mass in elite female road cyclists.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 80 (5), S. 472–478.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Hahn, A. G.; Martin, D. T.; Logan, P.; Parisotto, R.; Gore, C. J. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| A comparison of the physiological response to simulated altitude exposure and r-HuEpo administration.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 19 (11), S. 831–837&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Gore, C.J.; Parisotto, R.; Sharpe, K.; Hopkins, W.G.; Hahn, A.G. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effect of altitude on second-generation blood tests to detect erythropoietin abuse by athletes.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Haematologica 88 (9), S. 1053–1062&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Aughey, R. J.; Clark, S. A.; Gore, C. J.; Townsend, N. E.; Hahn, A. G.; Kinsman, T. A. et al. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Interspersed normoxia during live high, train low interventions reverses an early reduction in muscle Na+, K +ATPase activity in well-trained athletes.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 98 (3), S. 299–309&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Aughey, R. J.; Gore, C. J.; Hahn, A. G.; Garnham, A. P.; Clark, S. A.; Petersen, A. C. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Chronic intermittent hypoxia and incremental cycling exercise independently depress muscle in vitro maximal Na+-K+-ATPase activity in well-trained athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 98 (1), S. 186–192&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashman, S.B.; Monk, T.H.; Kupfer, D.J.; Clark, C.H.; Myers, F.S.; Frank, E.; Leibenluft (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Relationship between social rhythms and mood in patients with rapid cycling bipolar disorder.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Psychiatry Res 86 (1), S. 1–8&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Austin, N.; Nilwik, R.; Herzog, W. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| In vivo operational fascicle lengths of vastus lateralis during submaximal and maximal cycling.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Biomech 43 (12), S. 2394–2399&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Balmer, J.; Bird, S.; Davison, R.C.R.; Doherty, M.; Smith, P. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Mechanically braked Wingate powers: agreement between SRM, corrected and conventional methods of measurement.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 22 (7), S. 661–667&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Bird, S.; Davison, R.; Lucia, A. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effect of age on 16.1-km time-trial performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 26 (2), S. 197–206&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Davison, R.C.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Peak power predicts performance power during an outdoor 16.1-km cycling time trial.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 32 (8), S. 1485–1490&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Balmer, J.; Davison, R.C.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reliability of an air-braked ergometer to record peak power during a maximal cycling test.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 32 (10), S. 1790–1793&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Davison, R.C.; Coleman, D.A.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The validity of power output recorded during exercise performance tests using a Kingcycle air-braked cycle ergometer when compared with an SRM powermeter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 21 (3), S. 195–199&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bassett, D.R.; Kyle, C. R.; Passfield, L.; Broker, J.P.; Burke, E.R. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Comparing cycling world hour records, 1967-1996: modeling with empirical data.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 31 (11), S. 1665–1676&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bentley, D. J.; McNaughton, L. R.; Thompson, D.; Vleck, V. E.; Batterham, A. M. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Peak power output, the lactate threshold, and time trial performance in cyclists. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 33 (12), S. 2077–2081&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Crequy, S.; Chiementin, X. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and Reliability of the G-Cog BMX Powermeter.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Bertucci, W.; Duc, S.; Villerius, V.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of the Axiom PowerTrain cycle ergometer when compared with an SRM powermeter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (1), S. 59–65&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Duc, S.; Villerius, V.; Pernin, J. N.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and reliability of the PowerTap mobile cycling powermeter when compared with the SRM Device.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (10), S. 868–873&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Grappe, F.; Girard, A.; Betik, A.; Rouillon, J.D. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects on the crank torque profile when changing pedalling cadence in level ground and uphill road cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Biomech 38 (5), S. 1003–1010&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Grappe, F.; Groslambert, A. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Laboratory versus outdoor cycling conditions: differences in pedaling biomechanics. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Biomech 23 (2), S. 87–92&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Taiar, R.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Differences between sprint tests under laboratory and actual cycling conditions. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Med Phys Fitness 45 (3), S. 277–283&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Billaut, François; Gore, Christopher J.; Aughey, Robert J. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Enhancing team-sport athlete performance: is altitude training relevant?&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 42 (9), S. 751–767&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Brickley, G.; Dekerle, J.; Hammond, A.; Pringle, J.; Carter, H. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Assessment of Maximal Aerobic Power and Critical Power in a Single 90-s Isokinetic All-Out Cycling Test.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 28 (5), S. 414–419&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Broker, J.P.; Kyle, C.R.; Burke, E.R. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Racing cyclist power requirements in the 4000-m individual and team pursuits.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 31 (11), S. 1677–1685&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Brosnan, M. J.; Martin, D. T.; Hahn, A. G.; Gore, C. J.; Hawley, J. A. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Impaired interval exercise responses in elite female cyclists at moderate simulated altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 89 (5), S. 1819–1824&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Cangley, P.; Passfield, L.; Carter, H.; Bailey, M. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The Effect of Variable Gradients on Pacing in Cycling Time-Trials.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 32 (02), S. 132–136&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Carpes, F.P.; Rossato, M.; Faria, I.E.; Bolli Mota, C. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Bilateral pedaling asymmetry during a simulated 40-km cycling timetrial.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Med Phys Fitness 47 (1), S. 51–57&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Clark, Sally A.; Bourdon, P. C.; Schmidt, W.; Singh, B.; Cable, G.; Onus, K. J. et al. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The effect of acute simulated moderate altitude on power, performance and pacing strategies in well-trained cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 102 (1), S. 45–55&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Clark, Sally A.; Quod, M. J.; Clark, M. A.; Martin, D. T.; Saunders, P. U.; Gore, C. J. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Time course of haemoglobin mass during 21 days live high:train low simulated altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 106 (3), S. 399–406&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Clark, S.K.; Johnson, Thomas M. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Selenium stable isotope investigation into selenium biogeochemical cycling in a lacustrine environment: Sweitzer Lake, Colorado.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Environ. Qual. 39 (6), S. 2200–2210&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Coleman, D.A.; Wiles, J.D.; Nunn, M.; Smith, M.F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reliability of sprint test indices in well-trained cyclists. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (5), S. 383–387&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Doherty, M.; Balmer, J.; Davison, R.C.R.; Robinson, L.; Smith, P.M. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reliability of a combined 3-min constant load and performance cycling test.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 24 (5), S. 366–371&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Duc, S.; Betik, A-C; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| EMG activity does not change during a time trial in competitive cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (2), S. 145–150&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Duc, S.; Villerius, V.; Bertucci, W.; Pernin, J.N.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Muscular activity level during pedalling is not affected by crank inertial load.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 95 (2-3), S. 260–264&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Duc, S.; Villerius, V.; Bertucci, W.; Grappe, F. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and reproducibility of the ErgomoPro power meter compared with the SRM and Powertap power meters.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 2 (3), S. 270–281&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Eastwood, A.; Sharpe, K.; Bourdon, P.C.; Woolford, S.M.; Saunders, P.U.; Robertson, E.Y. et al. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Within-subject variation in hemoglobin mass in elite athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 44 (4), S. 725–732&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Ebert, T.R.; Martin, D.T.; McDonald, W.; Victor, J.; Plummer, J.; Withers, R.T. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Power output during women's World Cup road cycle racing.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 95 (5-6), S. 529–536&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ebert, T.R.; Martin, D.T.; Stephens, B.; Withers, R.T. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Power output during a professional men's road-cycling tour.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 1 (4), S. 324–335&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Emonson, D. L.; Aminuddin, A. H.; Wight, R. L.; Scroop, G. C.; Gore, C. J. (1997)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Training-induced increases in sea level VO2max and endurance are not enhanced by acute hypobaric exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 76 (1), S. 8–12&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Faiss, R.; Praz, M.; Meichtry, A.; Gobelet, C.; Deriaz, O. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The effect of mountain bike suspensions on vibrations and off-road uphill performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Med Phys Fitness 47 (2), S. 151–158&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Fu, Qi; Townsend, N.E.; Shiller, S.M.; Martini, E.R.; Okazaki, K.; Shibata, S. et al. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Intermittent hypobaric hypoxia exposure does not cause sustained alterations in autonomic control of blood pressure in young athletes. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Am. J. Physiol. Regul. Integr. Comp. Physiol. 292 (5), S. R1977-84&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gardner, A.S.; Martin, J.C.; Martin, D.T.; Barras, M.; Jenkins, D.G. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Maximal torque- and power-pedaling rate relationships for elite sprint cyclists in laboratory and field tests. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 101 (3), S. 287–292&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gardner, A.S.; Martin, D.T.; Jenkins, D.G.; Dyer, I.; van Eiden, J.; Barras, M.; Martinm, J.C. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Velocity-specific fatigue: quantifying fatigue during variable velocity cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Med Sci Sports Exerc 41 (4), S. 904–911&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gardner, A.S.; Stephens, S.; Martin, D.T.; Lawton, E.; Lee, H.; Jenkins, D. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Accuracy of SRM and power tap power monitoring systems for bicycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 36 (7), S. 1252–1258&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Garvican, L.A.; Hammond, K.; Varley, Matthew C.; Gore, C.J.; Billaut, F.; Aughey, R.J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Lower Running Performance and Exacerbated Fatigue in Soccer Played at 1600 m. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Garvican, L.A.; Martin, D.T.; Clark, S.A.; Schmidt, W.F.; Gore, C.J. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Variability of erythropoietin response to sleeping at simulated altitude: a cycling case study. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 2 (3), S. 327–331.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Garvican, L.A.; Pottgiesser, T.; Martin, D.T.; Schumacher, Y.O.; Barras, M.; Gore, C.J. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The contribution of haemoglobin mass to increases in cycling performance induced by simulated LHTL. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 111 (6), S. 1089–1101&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Garvican, L.A.; Saunders, P.U.; Pyne, D.B.; Martin, D.T.; Robertson, E.Y.; Gore, C.J. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Hemoglobin mass response to simulated hypoxia &amp;quot;blinded&amp;quot; by noisy measurement? &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 112 (10), S. 1797-8; author reply 1799&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Giacomoni, M.; Billaut, F.; Falgairette, G. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effects of the Time of Day on Repeated All-Out Cycle Performance and Short-Term Recovery Patterns. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 27 (6), S. 468–474&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| González-Haro, C.; Galilea B., P.A.; Soria, M.; Drobnic, F.; Escanero, J.F. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Comparison of nine theoretical models for estimating the mechanical power output in cycling. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Br J Sports Med 41 (8), S. 506-9; discussion 509&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| González-Haro, C.; Galilea, P.A.; Escanero, J.F. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Comparison of different theoretical models estimating peak power output and maximal oxygen uptake in trained and elite triathletes and endurance cyclists in the velodrome. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Sci 26 (6), S. 591–601&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Goosey-Tolfrey, V.; Castle, P.; Webborn, N.; Abel, T. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Aerobic capacity and peak power output of elite quadriplegic games players.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Br J Sports Med 40 (8), S. 684–687&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gordon, R.S.; Franklin, K.L.; Davies, B.; Baker, J.S. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Further mechanical considerations between polar and SRM mobile ergometer systems during laboratory-based high-intensity, intermittent cycling activity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Res Sports Med 15 (4), S. 241–247&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, Christopher John; Clark, Sally A.; Saunders, Philo U. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Nonhematological mechanisms of improved sea-level performance after hypoxic exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 39 (9), S. 1600–1609&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A. G.; Aughey, R. J.; Martin, D. T.; Ashenden, M. J.; Clark, S. A. et al. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Live high:train low increases muscle buffer capacity and submaximal cycling efficiency.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Acta Physiol. Scand. 173 (3), S. 275–286&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A. G.; Burge, C. M.; Telford, R. D. (1997)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| VO2max and haemoglobin mass of trained athletes during high intensity training.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 18 (6), S. 477–482&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore C.J.; Hahn A.G.; Scroop G.C.; Watson D.B.; Norton K.I.; Wood R.J.; Campbell D.P. (1996 )&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Increased arterial desaturation in trained cyclists during maximal exercise at 580 m altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Physiol 80(6), S. 2204-10&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A.; Rice, A.; Bourdon, P.; Lawrence, S.; Walsh, C. et al. (1998)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Altitude training at 2690m does not increase total haemoglobin mass or sea level VO2max in world champion track cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 1 (3), S. 156–170&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A. G. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Letter to the editors - Re: Heinicke K, Heinicke I, Schmidt W, Wolfarth B. A three-week traditional altitude training increases hemoglobin mass and red cell volume in elite biathlon athletes. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (6), S. 504-5; author reply 506-7&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore C.J.; Little S.C.; Hahn A.G.; Scroop G.C.; Norton K.I.; Bourdon P.C.; Woolford (1997)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reduced performance of male and female athletes at 580 m altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 75(2), S. 136-43&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; McSharry, P. E.; Hewitt, A. J.; Saunders, P. U. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Preparation for football competition at moderate to high altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Scand J Med Sci Sports 18 Suppl 1, S. 85–95&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, Christopher J.; Rodríguez, Ferran A.; Truijens, Martin J.; Townsend, Nathan E.; Stray-Gundersen, James; Levine, Benjamin D. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Increased serum erythropoietin but not red cell production after 4 wk of intermittent hypobaric hypoxia (4,000-5,500 m).&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 101 (5), S. 1386–1393&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gough, C. E.; Sharpe, K.; Garvican, L. A.; Anson, J. M.; Saunders, P. U.; Gore, C. J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The effects of injury and illness on haemoglobin mass.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 34 (9), S. 763–769&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gough, C.E.; Saunders, P.U.; Fowlie, J.; Savage, B.; Pyne, D.B.; Anson, J.M. et al. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Influence of altitude training modality on performance and total haemoglobin mass in elite swimmers.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 112 (9), S. 3275–3285&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Groslambert, A.; Grappe, F.; Bertucci, W.; Perrey, S.; Girard, A.J.; Rouillon, J.D. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| A perceptive individual time trial performed by triathletes to estimate the anaerobic threshold. A preliminary study.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Med Phys Fitness 44 (2), S. 147–156&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Haakonssen, Eric C.; Martin, David T.; Burke, Louise M.; Jenkins, David G. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Energy expenditure of constant- and variable-intensity cycling: power meter estimates. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 45 (9), S. 1833–1840&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hahn, A. G.; Gore, C. J. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The effect of altitude on cycling performance: a challenge to traditional concepts. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 31 (7), S. 533–557&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hahn, A. G.; Gore, C. J.; Martin, D. T.; Ashenden, M. J.; Roberts, A. D.; Logan, P. A. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Hahn, A. G.; Gore, C. J.; Martin, D. T.; Ashenden, M. J.; Roberts, A. D.; Logan, P. A. (2001) &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Comp. Biochem. Physiol., Part A Mol. Integr. Physiol. 128 (4), S. 777–789&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hajoglou, A.; Foster, C.; Koning, J.J. de; Lucia, A.; Kernozek, T.W.; Porcari, J.P. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effect of warm-up on cycle time trial performance. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 37 (9), S. 1608–1614&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Hopker, J.; Myers, S.; Jobson, S.A.; Bruce, W.; Passfield, L. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of the Wattbike cycle ergometer&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 31 (10), S. 731–736&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Hurst, H.T.; Atkins, S. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Agreement between polar and SRM mobile ergometer systems during laboratory-based high-intensity, intermittent cycling activity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 24 (8), S. 863–868&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hurst, H.T.; Atkins, S. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Power output of field-based downhill mountain biking.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 24 (10), S. 1047–1053&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Davison, R.C.; Coleman, D.A.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The validity of power output recorded during exercise performance tests using a Kingcycle air-braked cycle ergometer when compared with an SRM powermeter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 21 (3), S. 195–199&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Jobson, S.A.; Passfield, L.; Atkinson, G.; Barton, G.; Scarf, P. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The analysis and utilization of cycling training data.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 39 (10), S. 833–844&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Jobson, S.; Woodside, J.; Passfield, L.; Nevill, A. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Allometric Scaling of Uphill Cycling Performance. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (09), S. 753–757&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Joch, W.; Ückert, S. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of Whole Body Cooling of - 110 °C on the Heart Frequency in Endurance Activity and in Resting Time. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| W. Phys Rehab Kur Med  14(3), S. 146-150&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Julian, Colleen G.; Gore, Christopher J.; Wilber, Randall L.; Daniels, Jack T.; Fredericson, Michael; Stray-Gundersen, James et al. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Intermittent normobaric hypoxia does not alter performance or erythropoietic markers in highly trained distance runners.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 96 (5), S. 1800–1807&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Karsten, B.; Jobson, S.A.; Hopker, J.; Passfield, L., Beedie, C. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The 3-min Test Does not Provide a Valid Measure of Critical Power Using the SRM Isokinetic Mode.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med. Sep 10. [Epub ahead of print]&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, T. A.; Gore, C. J.; Hahn, A. G.; Hopkins, W. G.; Hawley, J. A.; McKenna, M. J. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sleep in athletes undertaking protocols of exposure to nocturnal simulated altitude at 2650 m.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 8 (2), S. 222–232&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, T. A.; Hahn, A. G.; Gore, C. J.; Martin, D. T.; Chow, C. M. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sleep quality responses to atmospheric variation: case studies of two elite female cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 6 (4), S. 436–442&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, Tahnee A.; Hahn, Allan G.; Gore, Christopher J.; Wilsmore, Bradley R.; Martin, David T.; Chow, Chin-Moi (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Respiratory events and periodic breathing in cyclists sleeping at 2,650-m simulated altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 92 (5), S. 2114–2118&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, Tahnee A.; Townsend, Nathan E.; Gore, Christopher J.; Hahn, Allan G.; Clark, Sally A.; Aughey, Robert J. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sleep disturbance at simulated altitude indicated by stratified respiratory disturbance index but not hypoxic ventilatory response.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 94 (5-6), S. 569–575&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kirkland, A.; Coleman, D.; Wiles, J.D.; Hopker, J. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of the Ergomopro powermeter.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (11), S. 913–916&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Loughlin, A.F.; Skiles, G.L.; Alberts, D.W.; Schaefer, W.H. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| An ion exchange liquid chromatography/mass spectrometry method for the determination of reduced and oxidized glutathione and glutathione conjugates in hepatocytes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Pharm Biomed Anal 26 (1), S. 131–142&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|MacIntosh, B.R.; Svedahl, K.; Kim, M. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Fatigue and optimal conditions for short-term work capacity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 92 (4-5), S. 369–375&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|MacRae HS-H; Hise, K.J.; Allen, P.J. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of front and dual suspension mountain bike systems on uphill cycling performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 32 (7), S. 1276–1280&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Mc Naughton, L.R.; Sherman, R.; Roberts, S.; Bentley, D.J. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Portable gas analyser Cosmed K4b2 compared to a laboratory based mass spectrometer system.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Med Phys Fitness 45 (3), S. 315–323&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| McDaniel, J.; Subudhi, A.; Martin, J.C. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Torso stabilization reduces the metabolic cost of producing cycling power.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Can J Appl Physiol 30 (4), S. 433–441&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|McLean, Blake D.; Buttifant, David; Gore, Christopher J.; White, Kevin; Liess, Carsten; Kemp, Justin (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Physiological and performance responses to a preseason altitude-training camp in elite team-sport athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 8 (4), S. 391–399&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Meyer, T.; Gabriel, H.H.W.; Auracher, M.; Scharhag, J.; Kindermann, W. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Metabolic profile of 4 h cycling in the field with varying amounts of carbohydrate supply.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 88 (4-5), S. 431–437&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Mijnarends, D.M.; Meijers, J.M.M.; Halfens, R.J.G.; Ter Borg, S.; Luiking, Y.C.; Verlaan, S. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of tools to measure muscle mass, strength, and physical performance in community-dwelling older people: a systematic review.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Am Med Dir Assoc 14 (3), S. 170–178&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Millet, G.P.; Tronche, C.; Fuster, N.; Candau, R. (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Level ground and uphill cycling efficiency in seated and standing positions.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Med Sci Sports Exerc 34 (10), S. 1645–1652&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Millet, G.P.; Tronche, C.; Fuster, N.; Bentley, D.J.; Candau, R. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and reliability of the Polar S710 mobile cycling powermeter.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 24 (3), S. 156–161&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Mornieux, G.; Gollhofer, A.; Stapelfeldt, B. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Muscle Coordination while Pulling up During Cycling. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 31 (12), S. 843–846&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Mornieux, G.; Stapelfeldt, B.; Gollhofer, A.; Belli, A. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effects of Pedal Type and Pull-Up Action during Cycling. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (10), S. 817–822&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Neville, V.; Pain, M.T.G.; Folland, J.P. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Aerobic power and peak power of elite America's Cup sailors. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 106 (1), S. 149–157&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Neville, V.; Pain, M.T.G.; Kantor, J.; Folland, J.P. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Influence of crank length and crank-axle height on standing armcrank (grinding) power.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 42 (2), S. 381–387&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Neville, V.; Zaher, N.; Pain, M.T.G.; Folland, J.P. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Lower limb influence on standing arm-cranking ('grinding').&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 30 (10), S. 713–718&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Neya, Mitsuo; Enoki, Taisuke; Ohiwa, Nao; Kawahara, Takashi; Gore, Christopher J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Increased hemoglobin mass and VO2max with 10 h nightly simulated altitude at 3000 m.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 8 (4), S. 366–372&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Nimmerichter, A.; Eston, R.G.; Bachl, N.; Williams, C. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Longitudinal monitoring of power output and heart rate profiles in elite cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 29 (8), S. 831–840&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Nimmerichter, A.; Williams, C.; Bachl, N.; Eston, R. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Evaluation of a field test to assess performance in elite cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 31 (3), S. 160–166&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|O’Hara, J.; Thomas, A.; Seims, A.; Cooke, C.; King, R.F.G (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reliability of a High-Intensity Endurance Cycling Test.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 33 (01), S. 18–25&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Parisotto, R.; Gore, C. J.; Hahn, A. G.; Ashenden, M. J.; Olds, T. S.; Martin, D. T. et al. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reticulocyte parameters as potential discriminators of recombinant human erythropoietin abuse in elite athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 21 (7), S. 471–479&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Paton, C.D.; Hopkins, W.G. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Tests of cycling performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 31 (7), S. 489–496&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Paton, C.D.; Hopkins, W.G. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Ergometer error and biological variation in power output in a performance test with three cycle ergometers.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 27 (6), S. 444–447&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Caillaud, C.; Thompson, M.W. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Central and Peripheral Fatigue during Passive and Exercise-Induced Hyperthermia &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med. Sci. Sports Exerc. 43 (9), S. 1657 – 1665&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Caillaud, C.; Thompson, M.W. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The role of aerobic fitness and exercise intensity on endurance performance in uncompensable heat stress conditions. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol  112, S. 1989 - 1999&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Cramer, M.N.; Chapman, P.G.; Caillaud, C.; Thompson, M.W. (2011)  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Cardiovascular strain impairs prolonged self-paced exercise in the heat. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Exp Physiol 96 (2), S. 134 - 144&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Cramer, M.N.; Chapman, P.G.; Caillaud, C.; Thompson, M.W. (2011)   &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Neuromuscular function following prolonged intense self-paced exercise in hot climatic conditions. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Physiol. 111, S. 1561 – 1569&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Perrey, S.; Grappe, F.; Girard, A.; Bringard, A.; Groslambert, A.; Bertucci, W.; Rouillon, J.D. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Physiological and metabolic responses of triathletes to a simulated 30-min time-trial in cycling at self-selected intensity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 24 (2), S. 138–143&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Pester, M.; Knorr, K.-H.; Friedrich, M.W.; Wagner, M.; Loy, A. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sulfate-reducing microorganisms in wetlands - fameless actors in carbon cycling and climate change.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Front Microbiol 3, S. 72&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Pinot, J.; Grappe, F. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The record power profile to assess performance in elite cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 32 (11), S. 839–844&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Pottgiesser, Torben; Garvican, Laura A.; Martin, David T.; Featonby, Jesse M.; Gore, Christopher J.; Schumacher, Yorck O. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Short-term hematological effects upon completion of a four-week simulated altitude camp.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Physiol Perform 7 (1), S. 79–83&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Quod, M. J.; Martin, D. T.; Martin, J. C.; Laursen, P. B. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The Power Profile Predicts Road Cycling MMP.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 31 (06), S. 397–401&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Reiser, M.; Meyer, T.; Kindermann, W.; Daugs, R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Transferability of workload measurements between three different types of ergometer.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 82 (3), S. 245–249&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Reiser, R.; Hart, C. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Cycling on Rollers: Kreitler Fan Resistance at Submaximal Levels of Effort.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (3), S. 212–216&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Richalet, J-P; Gore, C. J. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Live and/or sleep high:train low, using normobaric hypoxia.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Scand J Med Sci Sports 18 Suppl 1, S. 29–37&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Roberts, A. D.; Clark, S. A.; Townsend, N. E.; Anderson, M. E.; Gore, C. J.; Hahn, A. G. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Changes in performance, maximal oxygen uptake and maximal accumulated oxygen deficit after 5, 10 and 15 days of live high:train low altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 88 (4-5), S. 390–395&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Robertson, E.Y.; Saunders, P.U.; Pyne, D.B.; Aughey, R.J.; Anson, J.M.; Gore, C.J. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reproducibility of performance changes to simulated live high/train low altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 42 (2), S. 394–401&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Robertson, E.Y.; Saunders, P.U.; Pyne, D.B.; Gore, C.J.; Anson, J.M. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effectiveness of intermittent training in hypoxia combined with live high/train low.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| . J. Appl. Physiol. 110 (2), S. 379–387&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Rodríguez, F.A.; Truijens, M.J.; Townsend, N.E.; Stray-Gundersen, J.; Gore, C.J.; Levine, B.D. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Performance of runners and swimmers after four weeks of intermittent hypobaric hypoxic exposure plus sea level training.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 103 (5), S. 1523–1535&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Sassi, A.; Rampinini, E.; Martin, D.T.; Morelli, A. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of gradient and speed on freely chosen cadence: the key role of crank inertial load.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Biomech 42 (2), S. 171–177&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P. U.; Telford, R. D.; Pyne, D. B.; Cunningham, R. B.; Gore, C. J.; Hahn, A. G.; Hawley, J. A. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Improved running economy in elite runners after 20 days of simulated moderate-altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 96 (3), S. 931–937&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P. U.; Telford, R. D.; Pyne, D. B.; Hahn, A. G.; Gore, C. J. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Improved running economy and increased hemoglobin mass in elite runners after extended moderate altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 12 (1), S. 67–72&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P.U.; Ahlgrim, C.; Vallance, B.; Green, D.J.; Robertson, E.Y.; Clark, S.A. et al. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| An attempt to quantify the placebo effect from a three-week simulated altitude training camp in elite race walkers.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 5 (4), S. 521–534&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P.U.; Pyne, David B.; Gore, C.J. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Endurance training at altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| High Alt. Med. Biol. 10 (2), S. 135–148&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P.U.; Telford, R.D.; Pyne, D.D.; Gore, C.J.; Hahn, A.G. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Improved race performance in elite middle-distance runners after cumulative altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 4 (1), S. 134–138&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Sharpe, K.; Hopkins, W.; Emslie, K.R.; Howe, C.; Trout, G.J.; Kazlauskas, R. et al. (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Development of reference ranges in elite athletes for markers of altered erythropoiesis.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Haematologica 87 (12), S. 1248–1257&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Simons, M.; van Es, E.; Hendriksen, I. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Electrically assisted cycling: a new mode for meeting physical activity guidelines?&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 41 (11), S. 2097–2102&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Smith, M.F.; Davison, R.C.; Balmer, J.; Bird, S.R. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reliability of mean power recorded during indoor and outdoor selfpaced 40 km cycling time-trials.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 22 (4), S. 270–274&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Stapelfeldt, B.; Mornieux, G.; Oberheim, R.; Belli, A.; Gollhofer, A. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Development and evaluation of a new bicycle instrument for measurements of pedal forces and power output in cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 28 (4), S. 326–332&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Stapelfeldt, B.; Schwirtz, A.; Schumacher, Y.O.; Hillebrecht, M. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Workload demands in mountain bike racing.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 25 (4), S. 294–300&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Tomas, A.; Ross, E.Z.; Martin, J.C. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Fatigue during maximal sprint cycling: unique role of cumulative contraction cycles.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 42 (7), S. 1364–1369&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Townsend, N.E.; Gore, C.J.; Hahn, A.G.; Aughey, R.J.; Clark, S.A.; Kinsman, T.A. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Hypoxic ventilatory response is correlated with increased submaximal exercise ventilation after live high, train low.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 94 (1-2), S. 207–215&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Townsend, N.E.; Gore, C.J.; Hahn, A.G.; McKenna, M.J.; Aughey, R.J.; Clark, S.A. et al. (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Living high-training low increases hypoxic ventilatory response of well-trained endurance athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 93 (4), S. 1498–1505&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Truijens, M.J.; Rodríguez, F.A.; Townsend, N.E.; Stray-Gundersen, J.; Gore, C.J.; Levine, B.D. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The effect of intermittent hypobaric hypoxic exposure and sea level training on submaximal economy in well-trained swimmers and runners.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 104 (2), S. 328–337&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Vaile, J.; Halson, S.; Gill, N.; Dawson, B. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effect of Hydrotherapy on Recovery from Fatigue.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 29 (7), S. 539–544&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| van der Woude, L.H.V.; Horstman, A.; Faas, P.; Mechielsen, S.; Bafghi, H.A.; Koning, J.J. de (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Power output and metabolic cost of synchronous and asynchronous submaximal and peak level hand cycling on a motor driven treadmill in able-bodied male subjects.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Med Eng Phys 30 (5), S. 574–580&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Villerius, V.; Duc, S.; Grappe, F. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Physiological and Neuromuscular Responses of Competitive Cyclists during a Simulated Self-Paced Interval Training Session.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (09), S. 770–777&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Vogt, S.; Heinrich, L.; Schumacher, Y. O.; Blum, A.; Roecker, K.; Dickhuth, H.-H.; Schmid, A. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Power output during stage racing in professional road cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 38 (1), S. 147–151&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Vogt, S.; Roecker, K.; Schumacher, Y. O.; Pottgiesser, T.; Dickhuth, H-H; Schmid, A.; Heinrich, L. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Cadence-power-relationship during decisive mountain ascents at the Tour de France.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 29 (3), S. 244–250&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Vogt, S.; Schumacher, Y.O.; Blum, A.; Roecker, K.; Dickhuth, H.-H.; Schmid, A.; Heinrich, L. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Cycling power output produced during flat and mountain stages in the Giro d'Italia: a case study.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Sci 25 (12), S. 1299–1305&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Vogt, S.; Schumacher, Y. O.; Roecker, K.; Dickhuth, H-H; Schoberer, U.; Schmid, A.; Heinrich, L. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Power Output during the Tour de France.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 28 (9), S. 756–761&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wahl, P.; Mathes, S.; Köhler, K.; Achtzehn, S.; Bloch, W.; Mester, J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Acute Metabolic, Hormonal, and Psychological Responses to Different Endurance Training Protocols.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Horm Metab Res 45 (11), S. 827–833&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wahl, P.; Schmidt, A.; deMarees, M.; Achtzehn, S.; Bloch, W.; Mester, J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Responses of Angiogenic Growth Factors to Exercise, to Hypoxia and to Exercise under Hypoxic Conditions.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 34 (02), S. 95–100&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wiedemann, M. S. F.; Bosquet, L. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Anaerobic Work Capacity Derived from Isokinetic and Isoinertial Cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 31 (02), S. 89–94&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wilson, M.G.; Lane, A.M.; Beedie, C.J.; Farooq, A. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Influence of accurate and inaccurate 'split-time' feedback upon 10-mile time trial cycling performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 112 (1), S. 231–236&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wooles, A.L.; Robinson, A.J.; Keen, P.S. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|A Static Method for Obtaining a Calibration Factor for SRM Bicycle Power Cranks.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sports Engineering 8 (3), S. 137-144&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=File:SRM_Literatur_13.09.2016.pdf&amp;diff=2030</id>
		<title>File:SRM Literatur 13.09.2016.pdf</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=File:SRM_Literatur_13.09.2016.pdf&amp;diff=2030"/>
				<updated>2016-09-13T12:14:59Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Internationale_Literatur_zum_SRM-Ergometer&amp;diff=2029</id>
		<title>Internationale Literatur zum SRM-Ergometer</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Internationale_Literatur_zum_SRM-Ergometer&amp;diff=2029"/>
				<updated>2016-09-13T12:13:46Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{languages&lt;br /&gt;
|de=Internationale Literatur zum SRM-Ergometer&lt;br /&gt;
|en=International publications on the SRM Ergometer&lt;br /&gt;
|cn=International publications on the SRM Ergometer&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
In der folgenden Tabelle sind  diverese Sammlungen an Publikationen zu verschiedenen Themen als PDF-Dateien verlinkt.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot;&lt;br /&gt;
|+ style=&amp;quot;padding-bottom:1em&amp;quot; | Publikationen des SRM-Ergometers &lt;br /&gt;
|- class=&amp;quot;hintergrundfarbe6&amp;quot;&lt;br /&gt;
!style=&amp;quot;width:60%&amp;quot;| Publikationen!! style=&amp;quot;width:30%&amp;quot;| Letztes Update&lt;br /&gt;
|-&lt;br /&gt;
| [[Media:SRM Literatur 13.09.2016.pdf|SRM Scientific Publications]]&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| September 2016 &lt;br /&gt;
|-&lt;br /&gt;
| [[Media:Torque_publications_2015.pdf|Torque Publications]]&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| Januar 2015&lt;br /&gt;
|-&lt;br /&gt;
| [[Media:Eccentric_Chainrings_2015.pdf|Eccentric Chainrings Publications]]&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| April 2015&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
(In der folgenden Tabelle finden Sie aktuelle internationale Literaturstellen in denen das SRM - Ergometer und / oder die SRM - Trainingssysteme für wissenschaftliche Untersuchungen eingesetzt wurden.&lt;br /&gt;
[[Media:SRM_Scientific_Publications_06-2016.pdf|Hier]] finden sie die internationalen Literaturstellen in einem pfd - Dokument zusammengefasst.)&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot;&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|- class=&amp;quot;hintergrundfarbe6&amp;quot;&lt;br /&gt;
!style=&amp;quot;width:30%&amp;quot;| Autor!! style=&amp;quot;width:30%&amp;quot; | Titel!! style=&amp;quot;width:30%&amp;quot; | Publikation&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Abbiss, C.R.; Quod, M.J.; Martin, David T.; Netto, K.J.; Nosaka, K.; Lee, H. et al. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Dynamic pacing strategies during the cycle phase of an Ironman triathlon.  &lt;br /&gt;
|style=&amp;quot;vertical-align:top&amp;quot;| Med Sci Sports Exerc 38 (4), S. 726–734&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Abbiss, C.R.; Quod, M.J.; Levin, G.; Martin, D.T.; Laursen, P.B. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Accuracy of the Velotron ergometer and SRM power meter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 30 (2), S. 107–112.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Abel, T.; Burkett, B.; Schneider, S.; Lindschulten, R.; Strüder, H. K. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The exercise profile of an ultra-long handcycling race: the Styrkeprøven experience.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Spinal Cord 48 (12), S. 894–898.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Antonutto, G.; Capelli, C.; Girardis, M.; Zamparo, P.; di Prampero P.E. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of microgravity on maximal power of lower limbs during very short efforts in humans.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Physiol 86(1), S. 85-92.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Arkesteijn, M.; Hopker, J.; Jobson, S.; Passfield, L. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The Effect of Turbo Trainer Cycling on Pedalling Technique and Cycling Efficiency.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 34 (06), S. 520–525&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M. J.; Gore, C. J.; Burge, C. M.; Clough, M. L.; Bourdon, P. C.; Dobson, G. P.; Hahn, A. G. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Skin-prick blood samples are reliable for estimating Hb mass with the CO-dilution technique.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 79 (6), S. 535–537.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M. J.; Gore, C. J.; Dobson, G. P.; Boston, T. T.; Parisotto, R.; Emslie, K. R. et al. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Simulated moderate altitude elevates serum erythropoietin but does not increase reticulocyte production in well-trained runners.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 81 (5), S. 428–435&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Gore, C. J.; Dobson, G. P.; Hahn, A. G. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| &amp;quot;Live high, train low&amp;quot; does not change the total haemoglobin mass of male endurance athletes sleeping at a simulated altitude of 3000 m for 23 nights. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 80 (5), S. 479–484.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Gore, C. J.; Martin, D. T.; Dobson, G. P.; Hahn, A. G. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of a 12-day &amp;quot;live high, train low&amp;quot; camp on reticulocyte production and haemoglobin mass in elite female road cyclists.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 80 (5), S. 472–478.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Hahn, A. G.; Martin, D. T.; Logan, P.; Parisotto, R.; Gore, C. J. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| A comparison of the physiological response to simulated altitude exposure and r-HuEpo administration.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 19 (11), S. 831–837&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Gore, C.J.; Parisotto, R.; Sharpe, K.; Hopkins, W.G.; Hahn, A.G. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effect of altitude on second-generation blood tests to detect erythropoietin abuse by athletes.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Haematologica 88 (9), S. 1053–1062&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Aughey, R. J.; Clark, S. A.; Gore, C. J.; Townsend, N. E.; Hahn, A. G.; Kinsman, T. A. et al. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Interspersed normoxia during live high, train low interventions reverses an early reduction in muscle Na+, K +ATPase activity in well-trained athletes.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 98 (3), S. 299–309&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Aughey, R. J.; Gore, C. J.; Hahn, A. G.; Garnham, A. P.; Clark, S. A.; Petersen, A. C. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Chronic intermittent hypoxia and incremental cycling exercise independently depress muscle in vitro maximal Na+-K+-ATPase activity in well-trained athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 98 (1), S. 186–192&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashman, S.B.; Monk, T.H.; Kupfer, D.J.; Clark, C.H.; Myers, F.S.; Frank, E.; Leibenluft (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Relationship between social rhythms and mood in patients with rapid cycling bipolar disorder.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Psychiatry Res 86 (1), S. 1–8&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Austin, N.; Nilwik, R.; Herzog, W. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| In vivo operational fascicle lengths of vastus lateralis during submaximal and maximal cycling.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Biomech 43 (12), S. 2394–2399&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Balmer, J.; Bird, S.; Davison, R.C.R.; Doherty, M.; Smith, P. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Mechanically braked Wingate powers: agreement between SRM, corrected and conventional methods of measurement.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 22 (7), S. 661–667&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Bird, S.; Davison, R.; Lucia, A. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effect of age on 16.1-km time-trial performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 26 (2), S. 197–206&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Davison, R.C.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Peak power predicts performance power during an outdoor 16.1-km cycling time trial.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 32 (8), S. 1485–1490&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Balmer, J.; Davison, R.C.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reliability of an air-braked ergometer to record peak power during a maximal cycling test.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 32 (10), S. 1790–1793&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Davison, R.C.; Coleman, D.A.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The validity of power output recorded during exercise performance tests using a Kingcycle air-braked cycle ergometer when compared with an SRM powermeter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 21 (3), S. 195–199&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bassett, D.R.; Kyle, C. R.; Passfield, L.; Broker, J.P.; Burke, E.R. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Comparing cycling world hour records, 1967-1996: modeling with empirical data.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 31 (11), S. 1665–1676&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bentley, D. J.; McNaughton, L. R.; Thompson, D.; Vleck, V. E.; Batterham, A. M. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Peak power output, the lactate threshold, and time trial performance in cyclists. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 33 (12), S. 2077–2081&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Crequy, S.; Chiementin, X. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and Reliability of the G-Cog BMX Powermeter.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Bertucci, W.; Duc, S.; Villerius, V.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of the Axiom PowerTrain cycle ergometer when compared with an SRM powermeter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (1), S. 59–65&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Duc, S.; Villerius, V.; Pernin, J. N.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and reliability of the PowerTap mobile cycling powermeter when compared with the SRM Device.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (10), S. 868–873&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Grappe, F.; Girard, A.; Betik, A.; Rouillon, J.D. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects on the crank torque profile when changing pedalling cadence in level ground and uphill road cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Biomech 38 (5), S. 1003–1010&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Grappe, F.; Groslambert, A. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Laboratory versus outdoor cycling conditions: differences in pedaling biomechanics. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Biomech 23 (2), S. 87–92&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Taiar, R.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Differences between sprint tests under laboratory and actual cycling conditions. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Med Phys Fitness 45 (3), S. 277–283&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Billaut, François; Gore, Christopher J.; Aughey, Robert J. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Enhancing team-sport athlete performance: is altitude training relevant?&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 42 (9), S. 751–767&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Brickley, G.; Dekerle, J.; Hammond, A.; Pringle, J.; Carter, H. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Assessment of Maximal Aerobic Power and Critical Power in a Single 90-s Isokinetic All-Out Cycling Test.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 28 (5), S. 414–419&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Broker, J.P.; Kyle, C.R.; Burke, E.R. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Racing cyclist power requirements in the 4000-m individual and team pursuits.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 31 (11), S. 1677–1685&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Brosnan, M. J.; Martin, D. T.; Hahn, A. G.; Gore, C. J.; Hawley, J. A. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Impaired interval exercise responses in elite female cyclists at moderate simulated altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 89 (5), S. 1819–1824&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Cangley, P.; Passfield, L.; Carter, H.; Bailey, M. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The Effect of Variable Gradients on Pacing in Cycling Time-Trials.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 32 (02), S. 132–136&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Carpes, F.P.; Rossato, M.; Faria, I.E.; Bolli Mota, C. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Bilateral pedaling asymmetry during a simulated 40-km cycling timetrial.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Med Phys Fitness 47 (1), S. 51–57&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Clark, Sally A.; Bourdon, P. C.; Schmidt, W.; Singh, B.; Cable, G.; Onus, K. J. et al. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The effect of acute simulated moderate altitude on power, performance and pacing strategies in well-trained cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 102 (1), S. 45–55&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Clark, Sally A.; Quod, M. J.; Clark, M. A.; Martin, D. T.; Saunders, P. U.; Gore, C. J. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Time course of haemoglobin mass during 21 days live high:train low simulated altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 106 (3), S. 399–406&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Clark, S.K.; Johnson, Thomas M. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Selenium stable isotope investigation into selenium biogeochemical cycling in a lacustrine environment: Sweitzer Lake, Colorado.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Environ. Qual. 39 (6), S. 2200–2210&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Coleman, D.A.; Wiles, J.D.; Nunn, M.; Smith, M.F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reliability of sprint test indices in well-trained cyclists. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (5), S. 383–387&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Doherty, M.; Balmer, J.; Davison, R.C.R.; Robinson, L.; Smith, P.M. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reliability of a combined 3-min constant load and performance cycling test.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 24 (5), S. 366–371&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Duc, S.; Betik, A-C; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| EMG activity does not change during a time trial in competitive cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (2), S. 145–150&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Duc, S.; Villerius, V.; Bertucci, W.; Pernin, J.N.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Muscular activity level during pedalling is not affected by crank inertial load.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 95 (2-3), S. 260–264&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Duc, S.; Villerius, V.; Bertucci, W.; Grappe, F. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and reproducibility of the ErgomoPro power meter compared with the SRM and Powertap power meters.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 2 (3), S. 270–281&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Eastwood, A.; Sharpe, K.; Bourdon, P.C.; Woolford, S.M.; Saunders, P.U.; Robertson, E.Y. et al. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Within-subject variation in hemoglobin mass in elite athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 44 (4), S. 725–732&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Ebert, T.R.; Martin, D.T.; McDonald, W.; Victor, J.; Plummer, J.; Withers, R.T. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Power output during women's World Cup road cycle racing.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 95 (5-6), S. 529–536&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ebert, T.R.; Martin, D.T.; Stephens, B.; Withers, R.T. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Power output during a professional men's road-cycling tour.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 1 (4), S. 324–335&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Emonson, D. L.; Aminuddin, A. H.; Wight, R. L.; Scroop, G. C.; Gore, C. J. (1997)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Training-induced increases in sea level VO2max and endurance are not enhanced by acute hypobaric exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 76 (1), S. 8–12&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Faiss, R.; Praz, M.; Meichtry, A.; Gobelet, C.; Deriaz, O. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The effect of mountain bike suspensions on vibrations and off-road uphill performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Med Phys Fitness 47 (2), S. 151–158&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Fu, Qi; Townsend, N.E.; Shiller, S.M.; Martini, E.R.; Okazaki, K.; Shibata, S. et al. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Intermittent hypobaric hypoxia exposure does not cause sustained alterations in autonomic control of blood pressure in young athletes. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Am. J. Physiol. Regul. Integr. Comp. Physiol. 292 (5), S. R1977-84&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gardner, A.S.; Martin, J.C.; Martin, D.T.; Barras, M.; Jenkins, D.G. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Maximal torque- and power-pedaling rate relationships for elite sprint cyclists in laboratory and field tests. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 101 (3), S. 287–292&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gardner, A.S.; Martin, D.T.; Jenkins, D.G.; Dyer, I.; van Eiden, J.; Barras, M.; Martinm, J.C. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Velocity-specific fatigue: quantifying fatigue during variable velocity cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Med Sci Sports Exerc 41 (4), S. 904–911&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gardner, A.S.; Stephens, S.; Martin, D.T.; Lawton, E.; Lee, H.; Jenkins, D. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Accuracy of SRM and power tap power monitoring systems for bicycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 36 (7), S. 1252–1258&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Garvican, L.A.; Hammond, K.; Varley, Matthew C.; Gore, C.J.; Billaut, F.; Aughey, R.J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Lower Running Performance and Exacerbated Fatigue in Soccer Played at 1600 m. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Garvican, L.A.; Martin, D.T.; Clark, S.A.; Schmidt, W.F.; Gore, C.J. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Variability of erythropoietin response to sleeping at simulated altitude: a cycling case study. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 2 (3), S. 327–331.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Garvican, L.A.; Pottgiesser, T.; Martin, D.T.; Schumacher, Y.O.; Barras, M.; Gore, C.J. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The contribution of haemoglobin mass to increases in cycling performance induced by simulated LHTL. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 111 (6), S. 1089–1101&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Garvican, L.A.; Saunders, P.U.; Pyne, D.B.; Martin, D.T.; Robertson, E.Y.; Gore, C.J. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Hemoglobin mass response to simulated hypoxia &amp;quot;blinded&amp;quot; by noisy measurement? &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 112 (10), S. 1797-8; author reply 1799&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Giacomoni, M.; Billaut, F.; Falgairette, G. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effects of the Time of Day on Repeated All-Out Cycle Performance and Short-Term Recovery Patterns. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 27 (6), S. 468–474&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| González-Haro, C.; Galilea B., P.A.; Soria, M.; Drobnic, F.; Escanero, J.F. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Comparison of nine theoretical models for estimating the mechanical power output in cycling. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Br J Sports Med 41 (8), S. 506-9; discussion 509&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| González-Haro, C.; Galilea, P.A.; Escanero, J.F. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Comparison of different theoretical models estimating peak power output and maximal oxygen uptake in trained and elite triathletes and endurance cyclists in the velodrome. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Sci 26 (6), S. 591–601&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Goosey-Tolfrey, V.; Castle, P.; Webborn, N.; Abel, T. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Aerobic capacity and peak power output of elite quadriplegic games players.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Br J Sports Med 40 (8), S. 684–687&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gordon, R.S.; Franklin, K.L.; Davies, B.; Baker, J.S. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Further mechanical considerations between polar and SRM mobile ergometer systems during laboratory-based high-intensity, intermittent cycling activity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Res Sports Med 15 (4), S. 241–247&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, Christopher John; Clark, Sally A.; Saunders, Philo U. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Nonhematological mechanisms of improved sea-level performance after hypoxic exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 39 (9), S. 1600–1609&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A. G.; Aughey, R. J.; Martin, D. T.; Ashenden, M. J.; Clark, S. A. et al. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Live high:train low increases muscle buffer capacity and submaximal cycling efficiency.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Acta Physiol. Scand. 173 (3), S. 275–286&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A. G.; Burge, C. M.; Telford, R. D. (1997)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| VO2max and haemoglobin mass of trained athletes during high intensity training.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 18 (6), S. 477–482&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore C.J.; Hahn A.G.; Scroop G.C.; Watson D.B.; Norton K.I.; Wood R.J.; Campbell D.P. (1996 )&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Increased arterial desaturation in trained cyclists during maximal exercise at 580 m altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Physiol 80(6), S. 2204-10&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A.; Rice, A.; Bourdon, P.; Lawrence, S.; Walsh, C. et al. (1998)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Altitude training at 2690m does not increase total haemoglobin mass or sea level VO2max in world champion track cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 1 (3), S. 156–170&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A. G. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Letter to the editors - Re: Heinicke K, Heinicke I, Schmidt W, Wolfarth B. A three-week traditional altitude training increases hemoglobin mass and red cell volume in elite biathlon athletes. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (6), S. 504-5; author reply 506-7&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore C.J.; Little S.C.; Hahn A.G.; Scroop G.C.; Norton K.I.; Bourdon P.C.; Woolford (1997)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reduced performance of male and female athletes at 580 m altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 75(2), S. 136-43&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; McSharry, P. E.; Hewitt, A. J.; Saunders, P. U. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Preparation for football competition at moderate to high altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Scand J Med Sci Sports 18 Suppl 1, S. 85–95&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, Christopher J.; Rodríguez, Ferran A.; Truijens, Martin J.; Townsend, Nathan E.; Stray-Gundersen, James; Levine, Benjamin D. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Increased serum erythropoietin but not red cell production after 4 wk of intermittent hypobaric hypoxia (4,000-5,500 m).&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 101 (5), S. 1386–1393&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gough, C. E.; Sharpe, K.; Garvican, L. A.; Anson, J. M.; Saunders, P. U.; Gore, C. J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The effects of injury and illness on haemoglobin mass.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 34 (9), S. 763–769&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gough, C.E.; Saunders, P.U.; Fowlie, J.; Savage, B.; Pyne, D.B.; Anson, J.M. et al. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Influence of altitude training modality on performance and total haemoglobin mass in elite swimmers.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 112 (9), S. 3275–3285&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Groslambert, A.; Grappe, F.; Bertucci, W.; Perrey, S.; Girard, A.J.; Rouillon, J.D. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| A perceptive individual time trial performed by triathletes to estimate the anaerobic threshold. A preliminary study.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Med Phys Fitness 44 (2), S. 147–156&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Haakonssen, Eric C.; Martin, David T.; Burke, Louise M.; Jenkins, David G. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Energy expenditure of constant- and variable-intensity cycling: power meter estimates. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 45 (9), S. 1833–1840&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hahn, A. G.; Gore, C. J. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The effect of altitude on cycling performance: a challenge to traditional concepts. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 31 (7), S. 533–557&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hahn, A. G.; Gore, C. J.; Martin, D. T.; Ashenden, M. J.; Roberts, A. D.; Logan, P. A. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Hahn, A. G.; Gore, C. J.; Martin, D. T.; Ashenden, M. J.; Roberts, A. D.; Logan, P. A. (2001) &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Comp. Biochem. Physiol., Part A Mol. Integr. Physiol. 128 (4), S. 777–789&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hajoglou, A.; Foster, C.; Koning, J.J. de; Lucia, A.; Kernozek, T.W.; Porcari, J.P. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effect of warm-up on cycle time trial performance. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 37 (9), S. 1608–1614&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Hopker, J.; Myers, S.; Jobson, S.A.; Bruce, W.; Passfield, L. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of the Wattbike cycle ergometer&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 31 (10), S. 731–736&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Hurst, H.T.; Atkins, S. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Agreement between polar and SRM mobile ergometer systems during laboratory-based high-intensity, intermittent cycling activity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 24 (8), S. 863–868&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hurst, H.T.; Atkins, S. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Power output of field-based downhill mountain biking.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 24 (10), S. 1047–1053&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Davison, R.C.; Coleman, D.A.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The validity of power output recorded during exercise performance tests using a Kingcycle air-braked cycle ergometer when compared with an SRM powermeter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 21 (3), S. 195–199&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Jobson, S.A.; Passfield, L.; Atkinson, G.; Barton, G.; Scarf, P. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The analysis and utilization of cycling training data.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 39 (10), S. 833–844&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Jobson, S.; Woodside, J.; Passfield, L.; Nevill, A. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Allometric Scaling of Uphill Cycling Performance. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (09), S. 753–757&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Joch, W.; Ückert, S. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of Whole Body Cooling of - 110 °C on the Heart Frequency in Endurance Activity and in Resting Time. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| W. Phys Rehab Kur Med  14(3), S. 146-150&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Julian, Colleen G.; Gore, Christopher J.; Wilber, Randall L.; Daniels, Jack T.; Fredericson, Michael; Stray-Gundersen, James et al. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Intermittent normobaric hypoxia does not alter performance or erythropoietic markers in highly trained distance runners.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 96 (5), S. 1800–1807&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Karsten, B.; Jobson, S.A.; Hopker, J.; Passfield, L., Beedie, C. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The 3-min Test Does not Provide a Valid Measure of Critical Power Using the SRM Isokinetic Mode.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med. Sep 10. [Epub ahead of print]&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, T. A.; Gore, C. J.; Hahn, A. G.; Hopkins, W. G.; Hawley, J. A.; McKenna, M. J. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sleep in athletes undertaking protocols of exposure to nocturnal simulated altitude at 2650 m.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 8 (2), S. 222–232&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, T. A.; Hahn, A. G.; Gore, C. J.; Martin, D. T.; Chow, C. M. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sleep quality responses to atmospheric variation: case studies of two elite female cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 6 (4), S. 436–442&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, Tahnee A.; Hahn, Allan G.; Gore, Christopher J.; Wilsmore, Bradley R.; Martin, David T.; Chow, Chin-Moi (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Respiratory events and periodic breathing in cyclists sleeping at 2,650-m simulated altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 92 (5), S. 2114–2118&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, Tahnee A.; Townsend, Nathan E.; Gore, Christopher J.; Hahn, Allan G.; Clark, Sally A.; Aughey, Robert J. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sleep disturbance at simulated altitude indicated by stratified respiratory disturbance index but not hypoxic ventilatory response.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 94 (5-6), S. 569–575&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kirkland, A.; Coleman, D.; Wiles, J.D.; Hopker, J. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of the Ergomopro powermeter.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (11), S. 913–916&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Loughlin, A.F.; Skiles, G.L.; Alberts, D.W.; Schaefer, W.H. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| An ion exchange liquid chromatography/mass spectrometry method for the determination of reduced and oxidized glutathione and glutathione conjugates in hepatocytes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Pharm Biomed Anal 26 (1), S. 131–142&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|MacIntosh, B.R.; Svedahl, K.; Kim, M. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Fatigue and optimal conditions for short-term work capacity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 92 (4-5), S. 369–375&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|MacRae HS-H; Hise, K.J.; Allen, P.J. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of front and dual suspension mountain bike systems on uphill cycling performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 32 (7), S. 1276–1280&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Mc Naughton, L.R.; Sherman, R.; Roberts, S.; Bentley, D.J. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Portable gas analyser Cosmed K4b2 compared to a laboratory based mass spectrometer system.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Med Phys Fitness 45 (3), S. 315–323&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| McDaniel, J.; Subudhi, A.; Martin, J.C. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Torso stabilization reduces the metabolic cost of producing cycling power.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Can J Appl Physiol 30 (4), S. 433–441&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|McLean, Blake D.; Buttifant, David; Gore, Christopher J.; White, Kevin; Liess, Carsten; Kemp, Justin (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Physiological and performance responses to a preseason altitude-training camp in elite team-sport athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 8 (4), S. 391–399&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Meyer, T.; Gabriel, H.H.W.; Auracher, M.; Scharhag, J.; Kindermann, W. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Metabolic profile of 4 h cycling in the field with varying amounts of carbohydrate supply.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 88 (4-5), S. 431–437&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Mijnarends, D.M.; Meijers, J.M.M.; Halfens, R.J.G.; Ter Borg, S.; Luiking, Y.C.; Verlaan, S. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of tools to measure muscle mass, strength, and physical performance in community-dwelling older people: a systematic review.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Am Med Dir Assoc 14 (3), S. 170–178&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Millet, G.P.; Tronche, C.; Fuster, N.; Candau, R. (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Level ground and uphill cycling efficiency in seated and standing positions.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Med Sci Sports Exerc 34 (10), S. 1645–1652&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Millet, G.P.; Tronche, C.; Fuster, N.; Bentley, D.J.; Candau, R. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and reliability of the Polar S710 mobile cycling powermeter.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 24 (3), S. 156–161&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Mornieux, G.; Gollhofer, A.; Stapelfeldt, B. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Muscle Coordination while Pulling up During Cycling. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 31 (12), S. 843–846&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Mornieux, G.; Stapelfeldt, B.; Gollhofer, A.; Belli, A. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effects of Pedal Type and Pull-Up Action during Cycling. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (10), S. 817–822&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Neville, V.; Pain, M.T.G.; Folland, J.P. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Aerobic power and peak power of elite America's Cup sailors. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 106 (1), S. 149–157&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Neville, V.; Pain, M.T.G.; Kantor, J.; Folland, J.P. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Influence of crank length and crank-axle height on standing armcrank (grinding) power.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 42 (2), S. 381–387&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Neville, V.; Zaher, N.; Pain, M.T.G.; Folland, J.P. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Lower limb influence on standing arm-cranking ('grinding').&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 30 (10), S. 713–718&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Neya, Mitsuo; Enoki, Taisuke; Ohiwa, Nao; Kawahara, Takashi; Gore, Christopher J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Increased hemoglobin mass and VO2max with 10 h nightly simulated altitude at 3000 m.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 8 (4), S. 366–372&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Nimmerichter, A.; Eston, R.G.; Bachl, N.; Williams, C. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Longitudinal monitoring of power output and heart rate profiles in elite cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 29 (8), S. 831–840&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Nimmerichter, A.; Williams, C.; Bachl, N.; Eston, R. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Evaluation of a field test to assess performance in elite cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 31 (3), S. 160–166&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|O’Hara, J.; Thomas, A.; Seims, A.; Cooke, C.; King, R.F.G (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reliability of a High-Intensity Endurance Cycling Test.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 33 (01), S. 18–25&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Parisotto, R.; Gore, C. J.; Hahn, A. G.; Ashenden, M. J.; Olds, T. S.; Martin, D. T. et al. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reticulocyte parameters as potential discriminators of recombinant human erythropoietin abuse in elite athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 21 (7), S. 471–479&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Paton, C.D.; Hopkins, W.G. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Tests of cycling performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 31 (7), S. 489–496&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Paton, C.D.; Hopkins, W.G. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Ergometer error and biological variation in power output in a performance test with three cycle ergometers.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 27 (6), S. 444–447&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Caillaud, C.; Thompson, M.W. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Central and Peripheral Fatigue during Passive and Exercise-Induced Hyperthermia &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med. Sci. Sports Exerc. 43 (9), S. 1657 – 1665&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Caillaud, C.; Thompson, M.W. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The role of aerobic fitness and exercise intensity on endurance performance in uncompensable heat stress conditions. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol  112, S. 1989 - 1999&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Cramer, M.N.; Chapman, P.G.; Caillaud, C.; Thompson, M.W. (2011)  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Cardiovascular strain impairs prolonged self-paced exercise in the heat. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Exp Physiol 96 (2), S. 134 - 144&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Cramer, M.N.; Chapman, P.G.; Caillaud, C.; Thompson, M.W. (2011)   &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Neuromuscular function following prolonged intense self-paced exercise in hot climatic conditions. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Physiol. 111, S. 1561 – 1569&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Perrey, S.; Grappe, F.; Girard, A.; Bringard, A.; Groslambert, A.; Bertucci, W.; Rouillon, J.D. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Physiological and metabolic responses of triathletes to a simulated 30-min time-trial in cycling at self-selected intensity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 24 (2), S. 138–143&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Pester, M.; Knorr, K.-H.; Friedrich, M.W.; Wagner, M.; Loy, A. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sulfate-reducing microorganisms in wetlands - fameless actors in carbon cycling and climate change.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Front Microbiol 3, S. 72&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Pinot, J.; Grappe, F. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The record power profile to assess performance in elite cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 32 (11), S. 839–844&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Pottgiesser, Torben; Garvican, Laura A.; Martin, David T.; Featonby, Jesse M.; Gore, Christopher J.; Schumacher, Yorck O. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Short-term hematological effects upon completion of a four-week simulated altitude camp.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Physiol Perform 7 (1), S. 79–83&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Quod, M. J.; Martin, D. T.; Martin, J. C.; Laursen, P. B. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The Power Profile Predicts Road Cycling MMP.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 31 (06), S. 397–401&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Reiser, M.; Meyer, T.; Kindermann, W.; Daugs, R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Transferability of workload measurements between three different types of ergometer.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 82 (3), S. 245–249&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Reiser, R.; Hart, C. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Cycling on Rollers: Kreitler Fan Resistance at Submaximal Levels of Effort.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (3), S. 212–216&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Richalet, J-P; Gore, C. J. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Live and/or sleep high:train low, using normobaric hypoxia.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Scand J Med Sci Sports 18 Suppl 1, S. 29–37&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Roberts, A. D.; Clark, S. A.; Townsend, N. E.; Anderson, M. E.; Gore, C. J.; Hahn, A. G. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Changes in performance, maximal oxygen uptake and maximal accumulated oxygen deficit after 5, 10 and 15 days of live high:train low altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 88 (4-5), S. 390–395&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Robertson, E.Y.; Saunders, P.U.; Pyne, D.B.; Aughey, R.J.; Anson, J.M.; Gore, C.J. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reproducibility of performance changes to simulated live high/train low altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 42 (2), S. 394–401&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Robertson, E.Y.; Saunders, P.U.; Pyne, D.B.; Gore, C.J.; Anson, J.M. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effectiveness of intermittent training in hypoxia combined with live high/train low.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| . J. Appl. Physiol. 110 (2), S. 379–387&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Rodríguez, F.A.; Truijens, M.J.; Townsend, N.E.; Stray-Gundersen, J.; Gore, C.J.; Levine, B.D. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Performance of runners and swimmers after four weeks of intermittent hypobaric hypoxic exposure plus sea level training.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 103 (5), S. 1523–1535&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Sassi, A.; Rampinini, E.; Martin, D.T.; Morelli, A. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of gradient and speed on freely chosen cadence: the key role of crank inertial load.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Biomech 42 (2), S. 171–177&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P. U.; Telford, R. D.; Pyne, D. B.; Cunningham, R. B.; Gore, C. J.; Hahn, A. G.; Hawley, J. A. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Improved running economy in elite runners after 20 days of simulated moderate-altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 96 (3), S. 931–937&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P. U.; Telford, R. D.; Pyne, D. B.; Hahn, A. G.; Gore, C. J. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Improved running economy and increased hemoglobin mass in elite runners after extended moderate altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 12 (1), S. 67–72&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P.U.; Ahlgrim, C.; Vallance, B.; Green, D.J.; Robertson, E.Y.; Clark, S.A. et al. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| An attempt to quantify the placebo effect from a three-week simulated altitude training camp in elite race walkers.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 5 (4), S. 521–534&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P.U.; Pyne, David B.; Gore, C.J. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Endurance training at altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| High Alt. Med. Biol. 10 (2), S. 135–148&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P.U.; Telford, R.D.; Pyne, D.D.; Gore, C.J.; Hahn, A.G. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Improved race performance in elite middle-distance runners after cumulative altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 4 (1), S. 134–138&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Sharpe, K.; Hopkins, W.; Emslie, K.R.; Howe, C.; Trout, G.J.; Kazlauskas, R. et al. (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Development of reference ranges in elite athletes for markers of altered erythropoiesis.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Haematologica 87 (12), S. 1248–1257&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Simons, M.; van Es, E.; Hendriksen, I. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Electrically assisted cycling: a new mode for meeting physical activity guidelines?&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 41 (11), S. 2097–2102&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Smith, M.F.; Davison, R.C.; Balmer, J.; Bird, S.R. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reliability of mean power recorded during indoor and outdoor selfpaced 40 km cycling time-trials.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 22 (4), S. 270–274&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Stapelfeldt, B.; Mornieux, G.; Oberheim, R.; Belli, A.; Gollhofer, A. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Development and evaluation of a new bicycle instrument for measurements of pedal forces and power output in cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 28 (4), S. 326–332&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Stapelfeldt, B.; Schwirtz, A.; Schumacher, Y.O.; Hillebrecht, M. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Workload demands in mountain bike racing.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 25 (4), S. 294–300&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Tomas, A.; Ross, E.Z.; Martin, J.C. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Fatigue during maximal sprint cycling: unique role of cumulative contraction cycles.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 42 (7), S. 1364–1369&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Townsend, N.E.; Gore, C.J.; Hahn, A.G.; Aughey, R.J.; Clark, S.A.; Kinsman, T.A. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Hypoxic ventilatory response is correlated with increased submaximal exercise ventilation after live high, train low.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 94 (1-2), S. 207–215&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Townsend, N.E.; Gore, C.J.; Hahn, A.G.; McKenna, M.J.; Aughey, R.J.; Clark, S.A. et al. (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Living high-training low increases hypoxic ventilatory response of well-trained endurance athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 93 (4), S. 1498–1505&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Truijens, M.J.; Rodríguez, F.A.; Townsend, N.E.; Stray-Gundersen, J.; Gore, C.J.; Levine, B.D. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The effect of intermittent hypobaric hypoxic exposure and sea level training on submaximal economy in well-trained swimmers and runners.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 104 (2), S. 328–337&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Vaile, J.; Halson, S.; Gill, N.; Dawson, B. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effect of Hydrotherapy on Recovery from Fatigue.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 29 (7), S. 539–544&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| van der Woude, L.H.V.; Horstman, A.; Faas, P.; Mechielsen, S.; Bafghi, H.A.; Koning, J.J. de (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Power output and metabolic cost of synchronous and asynchronous submaximal and peak level hand cycling on a motor driven treadmill in able-bodied male subjects.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Med Eng Phys 30 (5), S. 574–580&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Villerius, V.; Duc, S.; Grappe, F. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Physiological and Neuromuscular Responses of Competitive Cyclists during a Simulated Self-Paced Interval Training Session.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (09), S. 770–777&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Vogt, S.; Heinrich, L.; Schumacher, Y. O.; Blum, A.; Roecker, K.; Dickhuth, H.-H.; Schmid, A. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Power output during stage racing in professional road cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 38 (1), S. 147–151&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Vogt, S.; Roecker, K.; Schumacher, Y. O.; Pottgiesser, T.; Dickhuth, H-H; Schmid, A.; Heinrich, L. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Cadence-power-relationship during decisive mountain ascents at the Tour de France.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 29 (3), S. 244–250&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Vogt, S.; Schumacher, Y.O.; Blum, A.; Roecker, K.; Dickhuth, H.-H.; Schmid, A.; Heinrich, L. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Cycling power output produced during flat and mountain stages in the Giro d'Italia: a case study.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Sci 25 (12), S. 1299–1305&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Vogt, S.; Schumacher, Y. O.; Roecker, K.; Dickhuth, H-H; Schoberer, U.; Schmid, A.; Heinrich, L. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Power Output during the Tour de France.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 28 (9), S. 756–761&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wahl, P.; Mathes, S.; Köhler, K.; Achtzehn, S.; Bloch, W.; Mester, J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Acute Metabolic, Hormonal, and Psychological Responses to Different Endurance Training Protocols.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Horm Metab Res 45 (11), S. 827–833&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wahl, P.; Schmidt, A.; deMarees, M.; Achtzehn, S.; Bloch, W.; Mester, J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Responses of Angiogenic Growth Factors to Exercise, to Hypoxia and to Exercise under Hypoxic Conditions.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 34 (02), S. 95–100&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wiedemann, M. S. F.; Bosquet, L. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Anaerobic Work Capacity Derived from Isokinetic and Isoinertial Cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 31 (02), S. 89–94&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wilson, M.G.; Lane, A.M.; Beedie, C.J.; Farooq, A. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Influence of accurate and inaccurate 'split-time' feedback upon 10-mile time trial cycling performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 112 (1), S. 231–236&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wooles, A.L.; Robinson, A.J.; Keen, P.S. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|A Static Method for Obtaining a Calibration Factor for SRM Bicycle Power Cranks.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sports Engineering 8 (3), S. 137-144&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Main_Page&amp;diff=2028</id>
		<title>Main Page</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Main_Page&amp;diff=2028"/>
				<updated>2016-09-01T20:30:27Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: Undo revision 2027 by Administrator (talk)&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;#REDIRECT [[Einleitung]]&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Main_Page&amp;diff=2027</id>
		<title>Main Page</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Main_Page&amp;diff=2027"/>
				<updated>2016-09-01T20:29:37Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{languages&lt;br /&gt;
|de=Einleitung&lt;br /&gt;
|en=Introduction&lt;br /&gt;
|cn=Introduction&lt;br /&gt;
}}&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
 File:SRM-Ergometer-01.jpg|Das SRM - Hochleistungsergometer&lt;br /&gt;
 File:SRM-Ergometer-02.jpg|Das SRM - Powermeter Wissenschaft&lt;br /&gt;
 File:SRM-Ergometer-03.jpg|Individuell einstellbare Sattelposition &lt;br /&gt;
 File:SRM-Ergometer-04.jpg|SRM Ergometer mit Mobile Support System (MSS) &lt;br /&gt;
 File:SRM-Ergometer-05.jpg|Das SRM Ergometer in der Leistunsgdiagnostik &lt;br /&gt;
 File:SRM-Ergometer-06.jpg|SRM - Software: Darstellung Testprotokoll und Torque - Analyse&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[File:SRM-Ergometer-04.jpg|thumb|SRM Ergometer mit Mobile Support System (MSS)]]&lt;br /&gt;
&lt;br /&gt;
Das so gennante SRM - Hochleistungsergometer wurde für den Einsatz mit Radfahrern in Zusammenarbeit mit dem Bund Deutscher Radfahrer (BDR), mit Peter Keen von der British Cycling Federation und mit Dr. Wolfgang Stockhausen vom Universitätsklinikum Freiburg entwickelt. &lt;br /&gt;
&lt;br /&gt;
Die Idee war es ein exaktes und wissenschaftlich zuverlässiges Ergometer zu konstruieren, welches den hohen Drehmomenten der weltweit stärksten Radfahrer widerstehen kann und diese Drehmomente auch messen kann. &lt;br /&gt;
&lt;br /&gt;
Inzwischen wird das SRM - Ergometer weltweit von renommierten Universitäten und Leistunsgdiagnostikern für wissenschaftliche Fragestellungen im Labor, für leistungsphysiologische Untersuchungen und als Trainingsgerät zur professionellen Trainingsbegleitung mit hoher Validität eingesetzt.&lt;br /&gt;
&lt;br /&gt;
Das SRM - Ergometer erlaubt eine individuelle Einstellung der Sitzposition für den Radfahrer, sowohl für Sprinter als auch für Triathleten. In das Ergometer wurden Standard - Fahrrad Teile (Lenker, Sättel, Kurbeln, etc.) und verschieden große Schwungmassen integriert. &lt;br /&gt;
&lt;br /&gt;
Dadurch kann die kinetische Energie für eine Vielzahl von verschiedenen Testprofilen  &lt;br /&gt;
simuliert und genutzt werden. Das Ziel ist es mit dem Fahren auf dem SRM - Ergometer dem realen Fahren auf dem eigenen Rad in der Ebene oder auch bergauf sehr nahe zu kommen. &lt;br /&gt;
&lt;br /&gt;
Die Steuerung der mechanischen Konstruktion der Bremsanlage des Ergometers übernimmt die dazugehörige und speziell entwickelte SRM - Software. Sie bietet eine große Flexibilität um eigene Testprotokolle mit den verschienden Arbeitsweisen des Ergometers zu programmieren.&lt;br /&gt;
&lt;br /&gt;
Für das Training und für die Leistungsdiagnostik können sowohl isokinetische als auch hyperbolische Tests für jede Art von Radfahrer generiet werden. Die Steuerung durch die Software erlaubt die Programmierung von Rampenprotokollen, alle Varianten von Stufentests und Trainingsintervalle für BMX-, Bahnrad-, Straßenfahrer, Mountainbiker und Sprinter.&lt;br /&gt;
&lt;br /&gt;
Das Herzstück des SRM - Hochleistungsergometers ist das SRM PowerMeter Wissenschaft, welches eine anerkannte wissenschaftliche Genauigkeit von ± 0,5% erreicht.&lt;br /&gt;
&lt;br /&gt;
== Technische Daten ==&lt;br /&gt;
&lt;br /&gt;
[[File:Technische-Daten-des-SRM-Ergometer.jpg|thumb|Technische Daten des SRM-Ergometers]]&lt;br /&gt;
&lt;br /&gt;
Technische Eckpunkte des Hochleistungseergometers sind: &lt;br /&gt;
&lt;br /&gt;
* SRM - Ergometer mit integriertem SRM Training System Wissenschaft Version (Messgenauigkeit +/- 0,5%)&lt;br /&gt;
* Der Rahmen ist aus hochfesten Aluminiumprofilteilen geschweißt&lt;br /&gt;
* Schwingend gelagerter Getriebeblock mit Wirbelstrombremse und variabler Schwungmasse. Die schwingende Lagerung gewährleistet eine geringe Geräuschentwicklung&lt;br /&gt;
* Die Wirbelstrombremse wird mit +/- 24 Volt vom Netzteil aus angesteuert &lt;br /&gt;
* Bremsleistung: von 20 bis 2500 Watt; kurzfristig sogar bis 4000 Watt&lt;br /&gt;
* Zwei veränderbare Schwungmassen und 14 - Gang Rohloff - Nabenschaltung simulieren authentisch die kinetische Energie und das &amp;quot;Gefühl&amp;quot; mit realistischen Geschwindigkeiten zu fahren. Dadurch ist die Anpassung an das Körpergewicht des Sportlers in kleinen Schritten möglich&lt;br /&gt;
* Sitzposition und Lenker können in verschiedenen Positionen für Fahrer zwischen 140 cm und 200 cm Größe eingestellt werden &lt;br /&gt;
* Enger Q - Faktor von 151 mm&lt;br /&gt;
* Individuell einstellbare Kurbellänge von 150 - 190 mm in 2,5 mm Schritten&lt;br /&gt;
* Isokinetischer und hyperbolischer Betriebsmodus programmierbar &lt;br /&gt;
* Einfacher Wechsel und Montagemöglichkeit von Standardfahrradteilen (verschiedene Kurbellängen, Pedale, Lenker, Sättel, Kettenblätter, etc.)&lt;br /&gt;
* Die SRMWin Software zur einfachen Programmierung von Tests und zur Auswertung der Daten ist im Paket enthalten.&lt;br /&gt;
* Das Gewicht liegt bei etwa 100 kg, um eine hohe Standsicherheit zu gewährleisten&lt;br /&gt;
* An der Vorderseite befinden sich zwei Rollen, auf denen das Ergometer nach Anheben der hinteren Stellbeine gut gerollt und transportiert werden kann &lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- [[en:Introduction]] --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[Category:Ergometer]]&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Einleitung&amp;diff=2026</id>
		<title>Einleitung</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Einleitung&amp;diff=2026"/>
				<updated>2016-09-01T20:26:13Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{languages&lt;br /&gt;
|de=Einleitung&lt;br /&gt;
|en=Introduction&lt;br /&gt;
|cn=Introduction&lt;br /&gt;
}}&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
 File:SRM-Ergometer-01.jpg|Das SRM - Hochleistungsergometer&lt;br /&gt;
 File:SRM-Ergometer-02.jpg|Das SRM - Powermeter Wissenschaft&lt;br /&gt;
 File:SRM-Ergometer-03.jpg|Individuell einstellbare Sattelposition &lt;br /&gt;
 File:SRM-Ergometer-04.jpg|SRM Ergometer mit Mobile Support System (MSS) &lt;br /&gt;
 File:SRM-Ergometer-05.jpg|Das SRM Ergometer in der Leistunsgdiagnostik &lt;br /&gt;
 File:SRM-Ergometer-06.jpg|SRM - Software: Darstellung Testprotokoll und Torque - Analyse&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[File:SRM-Ergometer-04.jpg|thumb|SRM Ergometer mit Mobile Support System (MSS)]]&lt;br /&gt;
&lt;br /&gt;
Das so gennante SRM - Hochleistungsergometer wurde für den Einsatz mit Radfahrern in Zusammenarbeit mit dem Bund Deutscher Radfahrer (BDR), mit Peter Keen von der British Cycling Federation und mit Dr. Wolfgang Stockhausen vom Universitätsklinikum Freiburg entwickelt. &lt;br /&gt;
&lt;br /&gt;
Die Idee war es ein exaktes und wissenschaftlich zuverlässiges Ergometer zu konstruieren, welches den hohen Drehmomenten der weltweit stärksten Radfahrer widerstehen kann und diese Drehmomente auch messen kann. &lt;br /&gt;
&lt;br /&gt;
Inzwischen wird das SRM - Ergometer weltweit von renommierten Universitäten und Leistunsgdiagnostikern für wissenschaftliche Fragestellungen im Labor, für leistungsphysiologische Untersuchungen und als Trainingsgerät zur professionellen Trainingsbegleitung mit hoher Validität eingesetzt.&lt;br /&gt;
&lt;br /&gt;
Das SRM - Ergometer erlaubt eine individuelle Einstellung der Sitzposition für den Radfahrer, sowohl für Sprinter als auch für Triathleten. In das Ergometer wurden Standard - Fahrrad Teile (Lenker, Sättel, Kurbeln, etc.) und verschieden große Schwungmassen integriert. &lt;br /&gt;
&lt;br /&gt;
Dadurch kann die kinetische Energie für eine Vielzahl von verschiedenen Testprofilen  &lt;br /&gt;
simuliert und genutzt werden. Das Ziel ist es mit dem Fahren auf dem SRM - Ergometer dem realen Fahren auf dem eigenen Rad in der Ebene oder auch bergauf sehr nahe zu kommen. &lt;br /&gt;
&lt;br /&gt;
Die Steuerung der mechanischen Konstruktion der Bremsanlage des Ergometers übernimmt die dazugehörige und speziell entwickelte SRM - Software. Sie bietet eine große Flexibilität um eigene Testprotokolle mit den verschienden Arbeitsweisen des Ergometers zu programmieren.&lt;br /&gt;
&lt;br /&gt;
Für das Training und für die Leistungsdiagnostik können sowohl isokinetische als auch hyperbolische Tests für jede Art von Radfahrer generiet werden. Die Steuerung durch die Software erlaubt die Programmierung von Rampenprotokollen, alle Varianten von Stufentests und Trainingsintervalle für BMX-, Bahnrad-, Straßenfahrer, Mountainbiker und Sprinter.&lt;br /&gt;
&lt;br /&gt;
Das Herzstück des SRM - Hochleistungsergometers ist das SRM PowerMeter Wissenschaft, welches eine anerkannte wissenschaftliche Genauigkeit von ± 0,5% erreicht.&lt;br /&gt;
&lt;br /&gt;
== Technische Daten ==&lt;br /&gt;
&lt;br /&gt;
[[File:Technische-Daten-des-SRM-Ergometer.jpg|thumb|Technische Daten des SRM-Ergometers]]&lt;br /&gt;
&lt;br /&gt;
Technische Eckpunkte des Hochleistungseergometers sind: &lt;br /&gt;
&lt;br /&gt;
* SRM - Ergometer mit integriertem SRM Training System Wissenschaft Version (Messgenauigkeit +/- 0,5%)&lt;br /&gt;
* Der Rahmen ist aus hochfesten Aluminiumprofilteilen geschweißt&lt;br /&gt;
* Schwingend gelagerter Getriebeblock mit Wirbelstrombremse und variabler Schwungmasse. Die schwingende Lagerung gewährleistet eine geringe Geräuschentwicklung&lt;br /&gt;
* Die Wirbelstrombremse wird mit +/- 24 Volt vom Netzteil aus angesteuert &lt;br /&gt;
* Bremsleistung: von 20 bis 2500 Watt; kurzfristig sogar bis 4000 Watt&lt;br /&gt;
* Zwei veränderbare Schwungmassen und 14 - Gang Rohloff - Nabenschaltung simulieren authentisch die kinetische Energie und das &amp;quot;Gefühl&amp;quot; mit realistischen Geschwindigkeiten zu fahren. Dadurch ist die Anpassung an das Körpergewicht des Sportlers in kleinen Schritten möglich&lt;br /&gt;
* Sitzposition und Lenker können in verschiedenen Positionen für Fahrer zwischen 140 cm und 200 cm Größe eingestellt werden &lt;br /&gt;
* Enger Q - Faktor von 151 mm&lt;br /&gt;
* Individuell einstellbare Kurbellänge von 150 - 190 mm in 2,5 mm Schritten&lt;br /&gt;
* Isokinetischer und hyperbolischer Betriebsmodus programmierbar &lt;br /&gt;
* Einfacher Wechsel und Montagemöglichkeit von Standardfahrradteilen (verschiedene Kurbellängen, Pedale, Lenker, Sättel, Kettenblätter, etc.)&lt;br /&gt;
* Die SRMWin Software zur einfachen Programmierung von Tests und zur Auswertung der Daten ist im Paket enthalten.&lt;br /&gt;
* Das Gewicht liegt bei etwa 100 kg, um eine hohe Standsicherheit zu gewährleisten&lt;br /&gt;
* An der Vorderseite befinden sich zwei Rollen, auf denen das Ergometer nach Anheben der hinteren Stellbeine gut gerollt und transportiert werden kann &lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- [[en:Introduction]] --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[Category:Ergometer]]&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Einleitung&amp;diff=2025</id>
		<title>Einleitung</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Einleitung&amp;diff=2025"/>
				<updated>2016-09-01T20:25:10Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: Administrator moved page Main Page to Einleitung without leaving a redirect&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Einleitung&amp;diff=2024</id>
		<title>Einleitung</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Einleitung&amp;diff=2024"/>
				<updated>2016-09-01T20:24:48Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: Created blank page&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Main_Page&amp;diff=2023</id>
		<title>Main Page</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Main_Page&amp;diff=2023"/>
				<updated>2016-09-01T20:18:32Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: Administrator moved page Main Page to Einleitung&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;#REDIRECT [[Einleitung]]&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Template:Languages&amp;diff=2019</id>
		<title>Template:Languages</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Template:Languages&amp;diff=2019"/>
				<updated>2016-09-01T19:58:08Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{box&lt;br /&gt;
| header = Languages&lt;br /&gt;
| text = &lt;br /&gt;
{{{#if:{{{de|}}} | {{Language|de|{{{de|}}}|Deutsch}} | }}}&lt;br /&gt;
{{{#if:{{{en|}}} | {{Language|en|{{{en|}}}|English}} | }}}&lt;br /&gt;
}}&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=MediaWiki:Sidebar&amp;diff=2018</id>
		<title>MediaWiki:Sidebar</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=MediaWiki:Sidebar&amp;diff=2018"/>
				<updated>2016-07-02T07:01:55Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;** Einleitung|Einleitung&lt;br /&gt;
&lt;br /&gt;
** Mechanische Grundlagen|Mechanische Grundlagen&lt;br /&gt;
** Elektronische Grundlagen|Elektronische Grundlagen&lt;br /&gt;
** Kalibrierung des Ergometers|Kalibrierung&lt;br /&gt;
** SRM-Online Einstellungen in der SRMWin-Software|SRM-Online Einstellungen&lt;br /&gt;
** SRM-Online in der praktischen Darstellung|SRM-Online Praxis&lt;br /&gt;
** Datenexport|Datenexport  &lt;br /&gt;
** Torque Analysis - Tretkraftanalyse|Tretkraftanalyse&lt;br /&gt;
** FAQ's zum SRM-Ergometer|FAQ's&lt;br /&gt;
** Troubleshooting|Troubleshooting&lt;br /&gt;
** Wartung &amp;amp; Service|Wartung &amp;amp; Service&lt;br /&gt;
** Handbücher|Handbücher&lt;br /&gt;
** Internationale Literatur zum SRM-Ergometer|Literatur&lt;br /&gt;
** Referenzen|Referenzen&lt;br /&gt;
&lt;br /&gt;
* Quick Links&lt;br /&gt;
** recentchanges-url|recentchanges&lt;br /&gt;
** {{SERVER}}{{SCRIPTPATH}}/index.php?title=MediaWiki:Sidebar&amp;amp;action=edit| Edit Navigation&lt;br /&gt;
&lt;br /&gt;
* TOOLBOX&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=MediaWiki:Sidebar&amp;diff=2017</id>
		<title>MediaWiki:Sidebar</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=MediaWiki:Sidebar&amp;diff=2017"/>
				<updated>2016-07-02T07:01:32Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;** de:Einleitung|Einleitung&lt;br /&gt;
&lt;br /&gt;
** Mechanische Grundlagen|Mechanische Grundlagen&lt;br /&gt;
** Elektronische Grundlagen|Elektronische Grundlagen&lt;br /&gt;
** Kalibrierung des Ergometers|Kalibrierung&lt;br /&gt;
** SRM-Online Einstellungen in der SRMWin-Software|SRM-Online Einstellungen&lt;br /&gt;
** SRM-Online in der praktischen Darstellung|SRM-Online Praxis&lt;br /&gt;
** Datenexport|Datenexport  &lt;br /&gt;
** Torque Analysis - Tretkraftanalyse|Tretkraftanalyse&lt;br /&gt;
** FAQ's zum SRM-Ergometer|FAQ's&lt;br /&gt;
** Troubleshooting|Troubleshooting&lt;br /&gt;
** Wartung &amp;amp; Service|Wartung &amp;amp; Service&lt;br /&gt;
** Handbücher|Handbücher&lt;br /&gt;
** Internationale Literatur zum SRM-Ergometer|Literatur&lt;br /&gt;
** Referenzen|Referenzen&lt;br /&gt;
&lt;br /&gt;
* Quick Links&lt;br /&gt;
** recentchanges-url|recentchanges&lt;br /&gt;
** {{SERVER}}{{SCRIPTPATH}}/index.php?title=MediaWiki:Sidebar&amp;amp;action=edit| Edit Navigation&lt;br /&gt;
&lt;br /&gt;
* TOOLBOX&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Internationale_Literatur_zum_SRM-Ergometer&amp;diff=2016</id>
		<title>Internationale Literatur zum SRM-Ergometer</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Internationale_Literatur_zum_SRM-Ergometer&amp;diff=2016"/>
				<updated>2016-06-29T08:45:15Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{languages&lt;br /&gt;
|de=Internationale Literatur zum SRM-Ergometer&lt;br /&gt;
|en=International publications on the SRM Ergometer&lt;br /&gt;
|cn=International publications on the SRM Ergometer&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
In der folgenden Tabelle sind  diverese Sammlungen an Publikationen zu verschiedenen Themen als PDF-Dateien verlinkt.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot;&lt;br /&gt;
|+ style=&amp;quot;padding-bottom:1em&amp;quot; | Publikationen des SRM-Ergometers &lt;br /&gt;
|- class=&amp;quot;hintergrundfarbe6&amp;quot;&lt;br /&gt;
!style=&amp;quot;width:60%&amp;quot;| Publikationen!! style=&amp;quot;width:30%&amp;quot;| Letztes Update&lt;br /&gt;
|-&lt;br /&gt;
| [[Media:SRM_Scientific_Publications_06-2016.pdf|SRM Scientific Publications]]&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| Juni 2016 &lt;br /&gt;
|-&lt;br /&gt;
| [[Media:Torque_publications_2015.pdf|Torque Publications]]&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| Januar 2015&lt;br /&gt;
|-&lt;br /&gt;
| [[Media:Eccentric_Chainrings_2015.pdf|Eccentric Chainrings Publications]]&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| April 2015&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
(In der folgenden Tabelle finden Sie aktuelle internationale Literaturstellen in denen das SRM - Ergometer und / oder die SRM - Trainingssysteme für wissenschaftliche Untersuchungen eingesetzt wurden.&lt;br /&gt;
[[Media:SRM_Scientific_Publications_06-2016.pdf|Hier]] finden sie die internationalen Literaturstellen in einem pfd - Dokument zusammengefasst.)&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot;&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|- class=&amp;quot;hintergrundfarbe6&amp;quot;&lt;br /&gt;
!style=&amp;quot;width:30%&amp;quot;| Autor!! style=&amp;quot;width:30%&amp;quot; | Titel!! style=&amp;quot;width:30%&amp;quot; | Publikation&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Abbiss, C.R.; Quod, M.J.; Martin, David T.; Netto, K.J.; Nosaka, K.; Lee, H. et al. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Dynamic pacing strategies during the cycle phase of an Ironman triathlon.  &lt;br /&gt;
|style=&amp;quot;vertical-align:top&amp;quot;| Med Sci Sports Exerc 38 (4), S. 726–734&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Abbiss, C.R.; Quod, M.J.; Levin, G.; Martin, D.T.; Laursen, P.B. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Accuracy of the Velotron ergometer and SRM power meter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 30 (2), S. 107–112.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Abel, T.; Burkett, B.; Schneider, S.; Lindschulten, R.; Strüder, H. K. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The exercise profile of an ultra-long handcycling race: the Styrkeprøven experience.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Spinal Cord 48 (12), S. 894–898.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Antonutto, G.; Capelli, C.; Girardis, M.; Zamparo, P.; di Prampero P.E. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of microgravity on maximal power of lower limbs during very short efforts in humans.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Physiol 86(1), S. 85-92.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Arkesteijn, M.; Hopker, J.; Jobson, S.; Passfield, L. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The Effect of Turbo Trainer Cycling on Pedalling Technique and Cycling Efficiency.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 34 (06), S. 520–525&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M. J.; Gore, C. J.; Burge, C. M.; Clough, M. L.; Bourdon, P. C.; Dobson, G. P.; Hahn, A. G. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Skin-prick blood samples are reliable for estimating Hb mass with the CO-dilution technique.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 79 (6), S. 535–537.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M. J.; Gore, C. J.; Dobson, G. P.; Boston, T. T.; Parisotto, R.; Emslie, K. R. et al. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Simulated moderate altitude elevates serum erythropoietin but does not increase reticulocyte production in well-trained runners.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 81 (5), S. 428–435&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Gore, C. J.; Dobson, G. P.; Hahn, A. G. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| &amp;quot;Live high, train low&amp;quot; does not change the total haemoglobin mass of male endurance athletes sleeping at a simulated altitude of 3000 m for 23 nights. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 80 (5), S. 479–484.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Gore, C. J.; Martin, D. T.; Dobson, G. P.; Hahn, A. G. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of a 12-day &amp;quot;live high, train low&amp;quot; camp on reticulocyte production and haemoglobin mass in elite female road cyclists.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 80 (5), S. 472–478.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Hahn, A. G.; Martin, D. T.; Logan, P.; Parisotto, R.; Gore, C. J. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| A comparison of the physiological response to simulated altitude exposure and r-HuEpo administration.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 19 (11), S. 831–837&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Gore, C.J.; Parisotto, R.; Sharpe, K.; Hopkins, W.G.; Hahn, A.G. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effect of altitude on second-generation blood tests to detect erythropoietin abuse by athletes.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Haematologica 88 (9), S. 1053–1062&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Aughey, R. J.; Clark, S. A.; Gore, C. J.; Townsend, N. E.; Hahn, A. G.; Kinsman, T. A. et al. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Interspersed normoxia during live high, train low interventions reverses an early reduction in muscle Na+, K +ATPase activity in well-trained athletes.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 98 (3), S. 299–309&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Aughey, R. J.; Gore, C. J.; Hahn, A. G.; Garnham, A. P.; Clark, S. A.; Petersen, A. C. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Chronic intermittent hypoxia and incremental cycling exercise independently depress muscle in vitro maximal Na+-K+-ATPase activity in well-trained athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 98 (1), S. 186–192&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashman, S.B.; Monk, T.H.; Kupfer, D.J.; Clark, C.H.; Myers, F.S.; Frank, E.; Leibenluft (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Relationship between social rhythms and mood in patients with rapid cycling bipolar disorder.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Psychiatry Res 86 (1), S. 1–8&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Austin, N.; Nilwik, R.; Herzog, W. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| In vivo operational fascicle lengths of vastus lateralis during submaximal and maximal cycling.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Biomech 43 (12), S. 2394–2399&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Balmer, J.; Bird, S.; Davison, R.C.R.; Doherty, M.; Smith, P. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Mechanically braked Wingate powers: agreement between SRM, corrected and conventional methods of measurement.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 22 (7), S. 661–667&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Bird, S.; Davison, R.; Lucia, A. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effect of age on 16.1-km time-trial performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 26 (2), S. 197–206&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Davison, R.C.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Peak power predicts performance power during an outdoor 16.1-km cycling time trial.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 32 (8), S. 1485–1490&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Balmer, J.; Davison, R.C.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reliability of an air-braked ergometer to record peak power during a maximal cycling test.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 32 (10), S. 1790–1793&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Davison, R.C.; Coleman, D.A.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The validity of power output recorded during exercise performance tests using a Kingcycle air-braked cycle ergometer when compared with an SRM powermeter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 21 (3), S. 195–199&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bassett, D.R.; Kyle, C. R.; Passfield, L.; Broker, J.P.; Burke, E.R. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Comparing cycling world hour records, 1967-1996: modeling with empirical data.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 31 (11), S. 1665–1676&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bentley, D. J.; McNaughton, L. R.; Thompson, D.; Vleck, V. E.; Batterham, A. M. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Peak power output, the lactate threshold, and time trial performance in cyclists. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 33 (12), S. 2077–2081&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Crequy, S.; Chiementin, X. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and Reliability of the G-Cog BMX Powermeter.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Bertucci, W.; Duc, S.; Villerius, V.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of the Axiom PowerTrain cycle ergometer when compared with an SRM powermeter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (1), S. 59–65&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Duc, S.; Villerius, V.; Pernin, J. N.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and reliability of the PowerTap mobile cycling powermeter when compared with the SRM Device.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (10), S. 868–873&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Grappe, F.; Girard, A.; Betik, A.; Rouillon, J.D. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects on the crank torque profile when changing pedalling cadence in level ground and uphill road cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Biomech 38 (5), S. 1003–1010&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Grappe, F.; Groslambert, A. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Laboratory versus outdoor cycling conditions: differences in pedaling biomechanics. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Biomech 23 (2), S. 87–92&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Taiar, R.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Differences between sprint tests under laboratory and actual cycling conditions. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Med Phys Fitness 45 (3), S. 277–283&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Billaut, François; Gore, Christopher J.; Aughey, Robert J. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Enhancing team-sport athlete performance: is altitude training relevant?&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 42 (9), S. 751–767&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Brickley, G.; Dekerle, J.; Hammond, A.; Pringle, J.; Carter, H. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Assessment of Maximal Aerobic Power and Critical Power in a Single 90-s Isokinetic All-Out Cycling Test.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 28 (5), S. 414–419&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Broker, J.P.; Kyle, C.R.; Burke, E.R. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Racing cyclist power requirements in the 4000-m individual and team pursuits.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 31 (11), S. 1677–1685&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Brosnan, M. J.; Martin, D. T.; Hahn, A. G.; Gore, C. J.; Hawley, J. A. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Impaired interval exercise responses in elite female cyclists at moderate simulated altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 89 (5), S. 1819–1824&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Cangley, P.; Passfield, L.; Carter, H.; Bailey, M. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The Effect of Variable Gradients on Pacing in Cycling Time-Trials.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 32 (02), S. 132–136&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Carpes, F.P.; Rossato, M.; Faria, I.E.; Bolli Mota, C. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Bilateral pedaling asymmetry during a simulated 40-km cycling timetrial.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Med Phys Fitness 47 (1), S. 51–57&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Clark, Sally A.; Bourdon, P. C.; Schmidt, W.; Singh, B.; Cable, G.; Onus, K. J. et al. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The effect of acute simulated moderate altitude on power, performance and pacing strategies in well-trained cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 102 (1), S. 45–55&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Clark, Sally A.; Quod, M. J.; Clark, M. A.; Martin, D. T.; Saunders, P. U.; Gore, C. J. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Time course of haemoglobin mass during 21 days live high:train low simulated altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 106 (3), S. 399–406&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Clark, S.K.; Johnson, Thomas M. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Selenium stable isotope investigation into selenium biogeochemical cycling in a lacustrine environment: Sweitzer Lake, Colorado.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Environ. Qual. 39 (6), S. 2200–2210&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Coleman, D.A.; Wiles, J.D.; Nunn, M.; Smith, M.F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reliability of sprint test indices in well-trained cyclists. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (5), S. 383–387&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Doherty, M.; Balmer, J.; Davison, R.C.R.; Robinson, L.; Smith, P.M. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reliability of a combined 3-min constant load and performance cycling test.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 24 (5), S. 366–371&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Duc, S.; Betik, A-C; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| EMG activity does not change during a time trial in competitive cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (2), S. 145–150&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Duc, S.; Villerius, V.; Bertucci, W.; Pernin, J.N.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Muscular activity level during pedalling is not affected by crank inertial load.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 95 (2-3), S. 260–264&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Duc, S.; Villerius, V.; Bertucci, W.; Grappe, F. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and reproducibility of the ErgomoPro power meter compared with the SRM and Powertap power meters.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 2 (3), S. 270–281&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Eastwood, A.; Sharpe, K.; Bourdon, P.C.; Woolford, S.M.; Saunders, P.U.; Robertson, E.Y. et al. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Within-subject variation in hemoglobin mass in elite athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 44 (4), S. 725–732&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Ebert, T.R.; Martin, D.T.; McDonald, W.; Victor, J.; Plummer, J.; Withers, R.T. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Power output during women's World Cup road cycle racing.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 95 (5-6), S. 529–536&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ebert, T.R.; Martin, D.T.; Stephens, B.; Withers, R.T. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Power output during a professional men's road-cycling tour.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 1 (4), S. 324–335&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Emonson, D. L.; Aminuddin, A. H.; Wight, R. L.; Scroop, G. C.; Gore, C. J. (1997)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Training-induced increases in sea level VO2max and endurance are not enhanced by acute hypobaric exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 76 (1), S. 8–12&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Faiss, R.; Praz, M.; Meichtry, A.; Gobelet, C.; Deriaz, O. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The effect of mountain bike suspensions on vibrations and off-road uphill performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Med Phys Fitness 47 (2), S. 151–158&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Fu, Qi; Townsend, N.E.; Shiller, S.M.; Martini, E.R.; Okazaki, K.; Shibata, S. et al. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Intermittent hypobaric hypoxia exposure does not cause sustained alterations in autonomic control of blood pressure in young athletes. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Am. J. Physiol. Regul. Integr. Comp. Physiol. 292 (5), S. R1977-84&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gardner, A.S.; Martin, J.C.; Martin, D.T.; Barras, M.; Jenkins, D.G. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Maximal torque- and power-pedaling rate relationships for elite sprint cyclists in laboratory and field tests. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 101 (3), S. 287–292&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gardner, A.S.; Martin, D.T.; Jenkins, D.G.; Dyer, I.; van Eiden, J.; Barras, M.; Martinm, J.C. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Velocity-specific fatigue: quantifying fatigue during variable velocity cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Med Sci Sports Exerc 41 (4), S. 904–911&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gardner, A.S.; Stephens, S.; Martin, D.T.; Lawton, E.; Lee, H.; Jenkins, D. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Accuracy of SRM and power tap power monitoring systems for bicycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 36 (7), S. 1252–1258&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Garvican, L.A.; Hammond, K.; Varley, Matthew C.; Gore, C.J.; Billaut, F.; Aughey, R.J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Lower Running Performance and Exacerbated Fatigue in Soccer Played at 1600 m. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Garvican, L.A.; Martin, D.T.; Clark, S.A.; Schmidt, W.F.; Gore, C.J. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Variability of erythropoietin response to sleeping at simulated altitude: a cycling case study. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 2 (3), S. 327–331.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Garvican, L.A.; Pottgiesser, T.; Martin, D.T.; Schumacher, Y.O.; Barras, M.; Gore, C.J. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The contribution of haemoglobin mass to increases in cycling performance induced by simulated LHTL. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 111 (6), S. 1089–1101&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Garvican, L.A.; Saunders, P.U.; Pyne, D.B.; Martin, D.T.; Robertson, E.Y.; Gore, C.J. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Hemoglobin mass response to simulated hypoxia &amp;quot;blinded&amp;quot; by noisy measurement? &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 112 (10), S. 1797-8; author reply 1799&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Giacomoni, M.; Billaut, F.; Falgairette, G. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effects of the Time of Day on Repeated All-Out Cycle Performance and Short-Term Recovery Patterns. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 27 (6), S. 468–474&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| González-Haro, C.; Galilea B., P.A.; Soria, M.; Drobnic, F.; Escanero, J.F. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Comparison of nine theoretical models for estimating the mechanical power output in cycling. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Br J Sports Med 41 (8), S. 506-9; discussion 509&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| González-Haro, C.; Galilea, P.A.; Escanero, J.F. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Comparison of different theoretical models estimating peak power output and maximal oxygen uptake in trained and elite triathletes and endurance cyclists in the velodrome. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Sci 26 (6), S. 591–601&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Goosey-Tolfrey, V.; Castle, P.; Webborn, N.; Abel, T. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Aerobic capacity and peak power output of elite quadriplegic games players.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Br J Sports Med 40 (8), S. 684–687&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gordon, R.S.; Franklin, K.L.; Davies, B.; Baker, J.S. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Further mechanical considerations between polar and SRM mobile ergometer systems during laboratory-based high-intensity, intermittent cycling activity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Res Sports Med 15 (4), S. 241–247&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, Christopher John; Clark, Sally A.; Saunders, Philo U. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Nonhematological mechanisms of improved sea-level performance after hypoxic exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 39 (9), S. 1600–1609&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A. G.; Aughey, R. J.; Martin, D. T.; Ashenden, M. J.; Clark, S. A. et al. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Live high:train low increases muscle buffer capacity and submaximal cycling efficiency.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Acta Physiol. Scand. 173 (3), S. 275–286&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A. G.; Burge, C. M.; Telford, R. D. (1997)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| VO2max and haemoglobin mass of trained athletes during high intensity training.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 18 (6), S. 477–482&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore C.J.; Hahn A.G.; Scroop G.C.; Watson D.B.; Norton K.I.; Wood R.J.; Campbell D.P. (1996 )&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Increased arterial desaturation in trained cyclists during maximal exercise at 580 m altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Physiol 80(6), S. 2204-10&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A.; Rice, A.; Bourdon, P.; Lawrence, S.; Walsh, C. et al. (1998)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Altitude training at 2690m does not increase total haemoglobin mass or sea level VO2max in world champion track cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 1 (3), S. 156–170&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A. G. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Letter to the editors - Re: Heinicke K, Heinicke I, Schmidt W, Wolfarth B. A three-week traditional altitude training increases hemoglobin mass and red cell volume in elite biathlon athletes. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (6), S. 504-5; author reply 506-7&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore C.J.; Little S.C.; Hahn A.G.; Scroop G.C.; Norton K.I.; Bourdon P.C.; Woolford (1997)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reduced performance of male and female athletes at 580 m altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 75(2), S. 136-43&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; McSharry, P. E.; Hewitt, A. J.; Saunders, P. U. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Preparation for football competition at moderate to high altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Scand J Med Sci Sports 18 Suppl 1, S. 85–95&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, Christopher J.; Rodríguez, Ferran A.; Truijens, Martin J.; Townsend, Nathan E.; Stray-Gundersen, James; Levine, Benjamin D. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Increased serum erythropoietin but not red cell production after 4 wk of intermittent hypobaric hypoxia (4,000-5,500 m).&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 101 (5), S. 1386–1393&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gough, C. E.; Sharpe, K.; Garvican, L. A.; Anson, J. M.; Saunders, P. U.; Gore, C. J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The effects of injury and illness on haemoglobin mass.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 34 (9), S. 763–769&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gough, C.E.; Saunders, P.U.; Fowlie, J.; Savage, B.; Pyne, D.B.; Anson, J.M. et al. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Influence of altitude training modality on performance and total haemoglobin mass in elite swimmers.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 112 (9), S. 3275–3285&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Groslambert, A.; Grappe, F.; Bertucci, W.; Perrey, S.; Girard, A.J.; Rouillon, J.D. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| A perceptive individual time trial performed by triathletes to estimate the anaerobic threshold. A preliminary study.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Med Phys Fitness 44 (2), S. 147–156&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Haakonssen, Eric C.; Martin, David T.; Burke, Louise M.; Jenkins, David G. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Energy expenditure of constant- and variable-intensity cycling: power meter estimates. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 45 (9), S. 1833–1840&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hahn, A. G.; Gore, C. J. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The effect of altitude on cycling performance: a challenge to traditional concepts. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 31 (7), S. 533–557&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hahn, A. G.; Gore, C. J.; Martin, D. T.; Ashenden, M. J.; Roberts, A. D.; Logan, P. A. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Hahn, A. G.; Gore, C. J.; Martin, D. T.; Ashenden, M. J.; Roberts, A. D.; Logan, P. A. (2001) &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Comp. Biochem. Physiol., Part A Mol. Integr. Physiol. 128 (4), S. 777–789&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hajoglou, A.; Foster, C.; Koning, J.J. de; Lucia, A.; Kernozek, T.W.; Porcari, J.P. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effect of warm-up on cycle time trial performance. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 37 (9), S. 1608–1614&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Hopker, J.; Myers, S.; Jobson, S.A.; Bruce, W.; Passfield, L. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of the Wattbike cycle ergometer&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 31 (10), S. 731–736&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Hurst, H.T.; Atkins, S. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Agreement between polar and SRM mobile ergometer systems during laboratory-based high-intensity, intermittent cycling activity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 24 (8), S. 863–868&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hurst, H.T.; Atkins, S. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Power output of field-based downhill mountain biking.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 24 (10), S. 1047–1053&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Davison, R.C.; Coleman, D.A.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The validity of power output recorded during exercise performance tests using a Kingcycle air-braked cycle ergometer when compared with an SRM powermeter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 21 (3), S. 195–199&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Jobson, S.A.; Passfield, L.; Atkinson, G.; Barton, G.; Scarf, P. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The analysis and utilization of cycling training data.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 39 (10), S. 833–844&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Jobson, S.; Woodside, J.; Passfield, L.; Nevill, A. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Allometric Scaling of Uphill Cycling Performance. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (09), S. 753–757&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Joch, W.; Ückert, S. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of Whole Body Cooling of - 110 °C on the Heart Frequency in Endurance Activity and in Resting Time. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| W. Phys Rehab Kur Med  14(3), S. 146-150&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Julian, Colleen G.; Gore, Christopher J.; Wilber, Randall L.; Daniels, Jack T.; Fredericson, Michael; Stray-Gundersen, James et al. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Intermittent normobaric hypoxia does not alter performance or erythropoietic markers in highly trained distance runners.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 96 (5), S. 1800–1807&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Karsten, B.; Jobson, S.A.; Hopker, J.; Passfield, L., Beedie, C. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The 3-min Test Does not Provide a Valid Measure of Critical Power Using the SRM Isokinetic Mode.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med. Sep 10. [Epub ahead of print]&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, T. A.; Gore, C. J.; Hahn, A. G.; Hopkins, W. G.; Hawley, J. A.; McKenna, M. J. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sleep in athletes undertaking protocols of exposure to nocturnal simulated altitude at 2650 m.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 8 (2), S. 222–232&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, T. A.; Hahn, A. G.; Gore, C. J.; Martin, D. T.; Chow, C. M. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sleep quality responses to atmospheric variation: case studies of two elite female cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 6 (4), S. 436–442&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, Tahnee A.; Hahn, Allan G.; Gore, Christopher J.; Wilsmore, Bradley R.; Martin, David T.; Chow, Chin-Moi (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Respiratory events and periodic breathing in cyclists sleeping at 2,650-m simulated altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 92 (5), S. 2114–2118&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, Tahnee A.; Townsend, Nathan E.; Gore, Christopher J.; Hahn, Allan G.; Clark, Sally A.; Aughey, Robert J. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sleep disturbance at simulated altitude indicated by stratified respiratory disturbance index but not hypoxic ventilatory response.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 94 (5-6), S. 569–575&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kirkland, A.; Coleman, D.; Wiles, J.D.; Hopker, J. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of the Ergomopro powermeter.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (11), S. 913–916&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Loughlin, A.F.; Skiles, G.L.; Alberts, D.W.; Schaefer, W.H. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| An ion exchange liquid chromatography/mass spectrometry method for the determination of reduced and oxidized glutathione and glutathione conjugates in hepatocytes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Pharm Biomed Anal 26 (1), S. 131–142&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|MacIntosh, B.R.; Svedahl, K.; Kim, M. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Fatigue and optimal conditions for short-term work capacity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 92 (4-5), S. 369–375&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|MacRae HS-H; Hise, K.J.; Allen, P.J. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of front and dual suspension mountain bike systems on uphill cycling performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 32 (7), S. 1276–1280&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Mc Naughton, L.R.; Sherman, R.; Roberts, S.; Bentley, D.J. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Portable gas analyser Cosmed K4b2 compared to a laboratory based mass spectrometer system.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Med Phys Fitness 45 (3), S. 315–323&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| McDaniel, J.; Subudhi, A.; Martin, J.C. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Torso stabilization reduces the metabolic cost of producing cycling power.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Can J Appl Physiol 30 (4), S. 433–441&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|McLean, Blake D.; Buttifant, David; Gore, Christopher J.; White, Kevin; Liess, Carsten; Kemp, Justin (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Physiological and performance responses to a preseason altitude-training camp in elite team-sport athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 8 (4), S. 391–399&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Meyer, T.; Gabriel, H.H.W.; Auracher, M.; Scharhag, J.; Kindermann, W. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Metabolic profile of 4 h cycling in the field with varying amounts of carbohydrate supply.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 88 (4-5), S. 431–437&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Mijnarends, D.M.; Meijers, J.M.M.; Halfens, R.J.G.; Ter Borg, S.; Luiking, Y.C.; Verlaan, S. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of tools to measure muscle mass, strength, and physical performance in community-dwelling older people: a systematic review.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Am Med Dir Assoc 14 (3), S. 170–178&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Millet, G.P.; Tronche, C.; Fuster, N.; Candau, R. (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Level ground and uphill cycling efficiency in seated and standing positions.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Med Sci Sports Exerc 34 (10), S. 1645–1652&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Millet, G.P.; Tronche, C.; Fuster, N.; Bentley, D.J.; Candau, R. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and reliability of the Polar S710 mobile cycling powermeter.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 24 (3), S. 156–161&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Mornieux, G.; Gollhofer, A.; Stapelfeldt, B. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Muscle Coordination while Pulling up During Cycling. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 31 (12), S. 843–846&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Mornieux, G.; Stapelfeldt, B.; Gollhofer, A.; Belli, A. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effects of Pedal Type and Pull-Up Action during Cycling. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (10), S. 817–822&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Neville, V.; Pain, M.T.G.; Folland, J.P. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Aerobic power and peak power of elite America's Cup sailors. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 106 (1), S. 149–157&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Neville, V.; Pain, M.T.G.; Kantor, J.; Folland, J.P. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Influence of crank length and crank-axle height on standing armcrank (grinding) power.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 42 (2), S. 381–387&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Neville, V.; Zaher, N.; Pain, M.T.G.; Folland, J.P. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Lower limb influence on standing arm-cranking ('grinding').&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 30 (10), S. 713–718&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Neya, Mitsuo; Enoki, Taisuke; Ohiwa, Nao; Kawahara, Takashi; Gore, Christopher J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Increased hemoglobin mass and VO2max with 10 h nightly simulated altitude at 3000 m.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 8 (4), S. 366–372&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Nimmerichter, A.; Eston, R.G.; Bachl, N.; Williams, C. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Longitudinal monitoring of power output and heart rate profiles in elite cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 29 (8), S. 831–840&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Nimmerichter, A.; Williams, C.; Bachl, N.; Eston, R. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Evaluation of a field test to assess performance in elite cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 31 (3), S. 160–166&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|O’Hara, J.; Thomas, A.; Seims, A.; Cooke, C.; King, R.F.G (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reliability of a High-Intensity Endurance Cycling Test.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 33 (01), S. 18–25&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Parisotto, R.; Gore, C. J.; Hahn, A. G.; Ashenden, M. J.; Olds, T. S.; Martin, D. T. et al. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reticulocyte parameters as potential discriminators of recombinant human erythropoietin abuse in elite athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 21 (7), S. 471–479&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Paton, C.D.; Hopkins, W.G. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Tests of cycling performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 31 (7), S. 489–496&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Paton, C.D.; Hopkins, W.G. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Ergometer error and biological variation in power output in a performance test with three cycle ergometers.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 27 (6), S. 444–447&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Caillaud, C.; Thompson, M.W. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Central and Peripheral Fatigue during Passive and Exercise-Induced Hyperthermia &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med. Sci. Sports Exerc. 43 (9), S. 1657 – 1665&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Caillaud, C.; Thompson, M.W. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The role of aerobic fitness and exercise intensity on endurance performance in uncompensable heat stress conditions. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol  112, S. 1989 - 1999&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Cramer, M.N.; Chapman, P.G.; Caillaud, C.; Thompson, M.W. (2011)  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Cardiovascular strain impairs prolonged self-paced exercise in the heat. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Exp Physiol 96 (2), S. 134 - 144&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Cramer, M.N.; Chapman, P.G.; Caillaud, C.; Thompson, M.W. (2011)   &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Neuromuscular function following prolonged intense self-paced exercise in hot climatic conditions. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Physiol. 111, S. 1561 – 1569&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Perrey, S.; Grappe, F.; Girard, A.; Bringard, A.; Groslambert, A.; Bertucci, W.; Rouillon, J.D. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Physiological and metabolic responses of triathletes to a simulated 30-min time-trial in cycling at self-selected intensity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 24 (2), S. 138–143&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Pester, M.; Knorr, K.-H.; Friedrich, M.W.; Wagner, M.; Loy, A. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sulfate-reducing microorganisms in wetlands - fameless actors in carbon cycling and climate change.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Front Microbiol 3, S. 72&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Pinot, J.; Grappe, F. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The record power profile to assess performance in elite cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 32 (11), S. 839–844&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Pottgiesser, Torben; Garvican, Laura A.; Martin, David T.; Featonby, Jesse M.; Gore, Christopher J.; Schumacher, Yorck O. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Short-term hematological effects upon completion of a four-week simulated altitude camp.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Physiol Perform 7 (1), S. 79–83&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Quod, M. J.; Martin, D. T.; Martin, J. C.; Laursen, P. B. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The Power Profile Predicts Road Cycling MMP.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 31 (06), S. 397–401&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Reiser, M.; Meyer, T.; Kindermann, W.; Daugs, R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Transferability of workload measurements between three different types of ergometer.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 82 (3), S. 245–249&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Reiser, R.; Hart, C. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Cycling on Rollers: Kreitler Fan Resistance at Submaximal Levels of Effort.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (3), S. 212–216&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Richalet, J-P; Gore, C. J. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Live and/or sleep high:train low, using normobaric hypoxia.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Scand J Med Sci Sports 18 Suppl 1, S. 29–37&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Roberts, A. D.; Clark, S. A.; Townsend, N. E.; Anderson, M. E.; Gore, C. J.; Hahn, A. G. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Changes in performance, maximal oxygen uptake and maximal accumulated oxygen deficit after 5, 10 and 15 days of live high:train low altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 88 (4-5), S. 390–395&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Robertson, E.Y.; Saunders, P.U.; Pyne, D.B.; Aughey, R.J.; Anson, J.M.; Gore, C.J. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reproducibility of performance changes to simulated live high/train low altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 42 (2), S. 394–401&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Robertson, E.Y.; Saunders, P.U.; Pyne, D.B.; Gore, C.J.; Anson, J.M. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effectiveness of intermittent training in hypoxia combined with live high/train low.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| . J. Appl. Physiol. 110 (2), S. 379–387&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Rodríguez, F.A.; Truijens, M.J.; Townsend, N.E.; Stray-Gundersen, J.; Gore, C.J.; Levine, B.D. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Performance of runners and swimmers after four weeks of intermittent hypobaric hypoxic exposure plus sea level training.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 103 (5), S. 1523–1535&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Sassi, A.; Rampinini, E.; Martin, D.T.; Morelli, A. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of gradient and speed on freely chosen cadence: the key role of crank inertial load.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Biomech 42 (2), S. 171–177&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P. U.; Telford, R. D.; Pyne, D. B.; Cunningham, R. B.; Gore, C. J.; Hahn, A. G.; Hawley, J. A. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Improved running economy in elite runners after 20 days of simulated moderate-altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 96 (3), S. 931–937&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P. U.; Telford, R. D.; Pyne, D. B.; Hahn, A. G.; Gore, C. J. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Improved running economy and increased hemoglobin mass in elite runners after extended moderate altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 12 (1), S. 67–72&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P.U.; Ahlgrim, C.; Vallance, B.; Green, D.J.; Robertson, E.Y.; Clark, S.A. et al. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| An attempt to quantify the placebo effect from a three-week simulated altitude training camp in elite race walkers.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 5 (4), S. 521–534&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P.U.; Pyne, David B.; Gore, C.J. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Endurance training at altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| High Alt. Med. Biol. 10 (2), S. 135–148&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P.U.; Telford, R.D.; Pyne, D.D.; Gore, C.J.; Hahn, A.G. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Improved race performance in elite middle-distance runners after cumulative altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 4 (1), S. 134–138&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Sharpe, K.; Hopkins, W.; Emslie, K.R.; Howe, C.; Trout, G.J.; Kazlauskas, R. et al. (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Development of reference ranges in elite athletes for markers of altered erythropoiesis.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Haematologica 87 (12), S. 1248–1257&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Simons, M.; van Es, E.; Hendriksen, I. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Electrically assisted cycling: a new mode for meeting physical activity guidelines?&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 41 (11), S. 2097–2102&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Smith, M.F.; Davison, R.C.; Balmer, J.; Bird, S.R. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reliability of mean power recorded during indoor and outdoor selfpaced 40 km cycling time-trials.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 22 (4), S. 270–274&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Stapelfeldt, B.; Mornieux, G.; Oberheim, R.; Belli, A.; Gollhofer, A. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Development and evaluation of a new bicycle instrument for measurements of pedal forces and power output in cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 28 (4), S. 326–332&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Stapelfeldt, B.; Schwirtz, A.; Schumacher, Y.O.; Hillebrecht, M. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Workload demands in mountain bike racing.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 25 (4), S. 294–300&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Tomas, A.; Ross, E.Z.; Martin, J.C. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Fatigue during maximal sprint cycling: unique role of cumulative contraction cycles.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 42 (7), S. 1364–1369&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Townsend, N.E.; Gore, C.J.; Hahn, A.G.; Aughey, R.J.; Clark, S.A.; Kinsman, T.A. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Hypoxic ventilatory response is correlated with increased submaximal exercise ventilation after live high, train low.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 94 (1-2), S. 207–215&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Townsend, N.E.; Gore, C.J.; Hahn, A.G.; McKenna, M.J.; Aughey, R.J.; Clark, S.A. et al. (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Living high-training low increases hypoxic ventilatory response of well-trained endurance athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 93 (4), S. 1498–1505&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Truijens, M.J.; Rodríguez, F.A.; Townsend, N.E.; Stray-Gundersen, J.; Gore, C.J.; Levine, B.D. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The effect of intermittent hypobaric hypoxic exposure and sea level training on submaximal economy in well-trained swimmers and runners.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 104 (2), S. 328–337&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Vaile, J.; Halson, S.; Gill, N.; Dawson, B. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effect of Hydrotherapy on Recovery from Fatigue.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 29 (7), S. 539–544&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| van der Woude, L.H.V.; Horstman, A.; Faas, P.; Mechielsen, S.; Bafghi, H.A.; Koning, J.J. de (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Power output and metabolic cost of synchronous and asynchronous submaximal and peak level hand cycling on a motor driven treadmill in able-bodied male subjects.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Med Eng Phys 30 (5), S. 574–580&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Villerius, V.; Duc, S.; Grappe, F. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Physiological and Neuromuscular Responses of Competitive Cyclists during a Simulated Self-Paced Interval Training Session.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (09), S. 770–777&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Vogt, S.; Heinrich, L.; Schumacher, Y. O.; Blum, A.; Roecker, K.; Dickhuth, H.-H.; Schmid, A. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Power output during stage racing in professional road cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 38 (1), S. 147–151&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Vogt, S.; Roecker, K.; Schumacher, Y. O.; Pottgiesser, T.; Dickhuth, H-H; Schmid, A.; Heinrich, L. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Cadence-power-relationship during decisive mountain ascents at the Tour de France.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 29 (3), S. 244–250&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Vogt, S.; Schumacher, Y.O.; Blum, A.; Roecker, K.; Dickhuth, H.-H.; Schmid, A.; Heinrich, L. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Cycling power output produced during flat and mountain stages in the Giro d'Italia: a case study.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Sci 25 (12), S. 1299–1305&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Vogt, S.; Schumacher, Y. O.; Roecker, K.; Dickhuth, H-H; Schoberer, U.; Schmid, A.; Heinrich, L. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Power Output during the Tour de France.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 28 (9), S. 756–761&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wahl, P.; Mathes, S.; Köhler, K.; Achtzehn, S.; Bloch, W.; Mester, J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Acute Metabolic, Hormonal, and Psychological Responses to Different Endurance Training Protocols.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Horm Metab Res 45 (11), S. 827–833&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wahl, P.; Schmidt, A.; deMarees, M.; Achtzehn, S.; Bloch, W.; Mester, J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Responses of Angiogenic Growth Factors to Exercise, to Hypoxia and to Exercise under Hypoxic Conditions.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 34 (02), S. 95–100&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wiedemann, M. S. F.; Bosquet, L. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Anaerobic Work Capacity Derived from Isokinetic and Isoinertial Cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 31 (02), S. 89–94&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wilson, M.G.; Lane, A.M.; Beedie, C.J.; Farooq, A. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Influence of accurate and inaccurate 'split-time' feedback upon 10-mile time trial cycling performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 112 (1), S. 231–236&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wooles, A.L.; Robinson, A.J.; Keen, P.S. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|A Static Method for Obtaining a Calibration Factor for SRM Bicycle Power Cranks.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sports Engineering 8 (3), S. 137-144&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Internationale_Literatur_zum_SRM-Ergometer&amp;diff=2015</id>
		<title>Internationale Literatur zum SRM-Ergometer</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Internationale_Literatur_zum_SRM-Ergometer&amp;diff=2015"/>
				<updated>2016-06-29T08:43:47Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{languages&lt;br /&gt;
|de=Internationale Literatur zum SRM-Ergometer&lt;br /&gt;
|en=International publications on the SRM Ergometer&lt;br /&gt;
|cn=International publications on the SRM Ergometer&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
In der folgenden Tabelle sind  diverese Sammlungen an Publikationen zu verschiedenen Themen als PDF-Dateien verlinkt.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot;&lt;br /&gt;
|+ style=&amp;quot;padding-bottom:1em&amp;quot; | Publikationen des SRM-Ergometers &lt;br /&gt;
|- class=&amp;quot;hintergrundfarbe6&amp;quot;&lt;br /&gt;
!style=&amp;quot;width:60%&amp;quot;| Publikationen!! style=&amp;quot;width:30%&amp;quot;| Letztes Update&lt;br /&gt;
|-&lt;br /&gt;
| [[Media:SRM_Scientific_Publications_06-2016.pdf|SRM Scientific Publications]]&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| Juni 2016 &lt;br /&gt;
|-&lt;br /&gt;
| [[Media:Torque_publications_2015.pdf|Torque Publications]]&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| Januar 2015&lt;br /&gt;
|-&lt;br /&gt;
| [[Media:Eccentric_Chainrings_2015.pdf|Eccentric Chainrings Publications]]&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| April 2015&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
(In der folgenden Tabelle finden Sie aktuelle internationale Literaturstellen in denen das SRM - Ergometer und / oder die SRM - Trainingssysteme für wissenschaftliche Untersuchungen eingesetzt wurden.&lt;br /&gt;
[[Media:Scientific Publications SRM 2013.pdf|Hier]] finden sie die internationalen Literaturstellen in einem pfd - Dokument zusammengefasst.)&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot;&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|- class=&amp;quot;hintergrundfarbe6&amp;quot;&lt;br /&gt;
!style=&amp;quot;width:30%&amp;quot;| Autor!! style=&amp;quot;width:30%&amp;quot; | Titel!! style=&amp;quot;width:30%&amp;quot; | Publikation&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Abbiss, C.R.; Quod, M.J.; Martin, David T.; Netto, K.J.; Nosaka, K.; Lee, H. et al. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Dynamic pacing strategies during the cycle phase of an Ironman triathlon.  &lt;br /&gt;
|style=&amp;quot;vertical-align:top&amp;quot;| Med Sci Sports Exerc 38 (4), S. 726–734&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Abbiss, C.R.; Quod, M.J.; Levin, G.; Martin, D.T.; Laursen, P.B. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Accuracy of the Velotron ergometer and SRM power meter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 30 (2), S. 107–112.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Abel, T.; Burkett, B.; Schneider, S.; Lindschulten, R.; Strüder, H. K. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The exercise profile of an ultra-long handcycling race: the Styrkeprøven experience.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Spinal Cord 48 (12), S. 894–898.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Antonutto, G.; Capelli, C.; Girardis, M.; Zamparo, P.; di Prampero P.E. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of microgravity on maximal power of lower limbs during very short efforts in humans.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Physiol 86(1), S. 85-92.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Arkesteijn, M.; Hopker, J.; Jobson, S.; Passfield, L. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The Effect of Turbo Trainer Cycling on Pedalling Technique and Cycling Efficiency.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 34 (06), S. 520–525&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M. J.; Gore, C. J.; Burge, C. M.; Clough, M. L.; Bourdon, P. C.; Dobson, G. P.; Hahn, A. G. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Skin-prick blood samples are reliable for estimating Hb mass with the CO-dilution technique.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 79 (6), S. 535–537.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M. J.; Gore, C. J.; Dobson, G. P.; Boston, T. T.; Parisotto, R.; Emslie, K. R. et al. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Simulated moderate altitude elevates serum erythropoietin but does not increase reticulocyte production in well-trained runners.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 81 (5), S. 428–435&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Gore, C. J.; Dobson, G. P.; Hahn, A. G. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| &amp;quot;Live high, train low&amp;quot; does not change the total haemoglobin mass of male endurance athletes sleeping at a simulated altitude of 3000 m for 23 nights. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 80 (5), S. 479–484.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Gore, C. J.; Martin, D. T.; Dobson, G. P.; Hahn, A. G. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of a 12-day &amp;quot;live high, train low&amp;quot; camp on reticulocyte production and haemoglobin mass in elite female road cyclists.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 80 (5), S. 472–478.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Hahn, A. G.; Martin, D. T.; Logan, P.; Parisotto, R.; Gore, C. J. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| A comparison of the physiological response to simulated altitude exposure and r-HuEpo administration.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 19 (11), S. 831–837&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Gore, C.J.; Parisotto, R.; Sharpe, K.; Hopkins, W.G.; Hahn, A.G. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effect of altitude on second-generation blood tests to detect erythropoietin abuse by athletes.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Haematologica 88 (9), S. 1053–1062&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Aughey, R. J.; Clark, S. A.; Gore, C. J.; Townsend, N. E.; Hahn, A. G.; Kinsman, T. A. et al. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Interspersed normoxia during live high, train low interventions reverses an early reduction in muscle Na+, K +ATPase activity in well-trained athletes.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 98 (3), S. 299–309&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Aughey, R. J.; Gore, C. J.; Hahn, A. G.; Garnham, A. P.; Clark, S. A.; Petersen, A. C. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Chronic intermittent hypoxia and incremental cycling exercise independently depress muscle in vitro maximal Na+-K+-ATPase activity in well-trained athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 98 (1), S. 186–192&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashman, S.B.; Monk, T.H.; Kupfer, D.J.; Clark, C.H.; Myers, F.S.; Frank, E.; Leibenluft (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Relationship between social rhythms and mood in patients with rapid cycling bipolar disorder.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Psychiatry Res 86 (1), S. 1–8&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Austin, N.; Nilwik, R.; Herzog, W. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| In vivo operational fascicle lengths of vastus lateralis during submaximal and maximal cycling.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Biomech 43 (12), S. 2394–2399&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Balmer, J.; Bird, S.; Davison, R.C.R.; Doherty, M.; Smith, P. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Mechanically braked Wingate powers: agreement between SRM, corrected and conventional methods of measurement.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 22 (7), S. 661–667&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Bird, S.; Davison, R.; Lucia, A. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effect of age on 16.1-km time-trial performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 26 (2), S. 197–206&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Davison, R.C.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Peak power predicts performance power during an outdoor 16.1-km cycling time trial.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 32 (8), S. 1485–1490&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Balmer, J.; Davison, R.C.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reliability of an air-braked ergometer to record peak power during a maximal cycling test.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 32 (10), S. 1790–1793&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Davison, R.C.; Coleman, D.A.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The validity of power output recorded during exercise performance tests using a Kingcycle air-braked cycle ergometer when compared with an SRM powermeter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 21 (3), S. 195–199&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bassett, D.R.; Kyle, C. R.; Passfield, L.; Broker, J.P.; Burke, E.R. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Comparing cycling world hour records, 1967-1996: modeling with empirical data.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 31 (11), S. 1665–1676&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bentley, D. J.; McNaughton, L. R.; Thompson, D.; Vleck, V. E.; Batterham, A. M. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Peak power output, the lactate threshold, and time trial performance in cyclists. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 33 (12), S. 2077–2081&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Crequy, S.; Chiementin, X. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and Reliability of the G-Cog BMX Powermeter.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Bertucci, W.; Duc, S.; Villerius, V.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of the Axiom PowerTrain cycle ergometer when compared with an SRM powermeter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (1), S. 59–65&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Duc, S.; Villerius, V.; Pernin, J. N.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and reliability of the PowerTap mobile cycling powermeter when compared with the SRM Device.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (10), S. 868–873&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Grappe, F.; Girard, A.; Betik, A.; Rouillon, J.D. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects on the crank torque profile when changing pedalling cadence in level ground and uphill road cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Biomech 38 (5), S. 1003–1010&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Grappe, F.; Groslambert, A. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Laboratory versus outdoor cycling conditions: differences in pedaling biomechanics. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Biomech 23 (2), S. 87–92&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Taiar, R.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Differences between sprint tests under laboratory and actual cycling conditions. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Med Phys Fitness 45 (3), S. 277–283&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Billaut, François; Gore, Christopher J.; Aughey, Robert J. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Enhancing team-sport athlete performance: is altitude training relevant?&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 42 (9), S. 751–767&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Brickley, G.; Dekerle, J.; Hammond, A.; Pringle, J.; Carter, H. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Assessment of Maximal Aerobic Power and Critical Power in a Single 90-s Isokinetic All-Out Cycling Test.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 28 (5), S. 414–419&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Broker, J.P.; Kyle, C.R.; Burke, E.R. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Racing cyclist power requirements in the 4000-m individual and team pursuits.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 31 (11), S. 1677–1685&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Brosnan, M. J.; Martin, D. T.; Hahn, A. G.; Gore, C. J.; Hawley, J. A. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Impaired interval exercise responses in elite female cyclists at moderate simulated altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 89 (5), S. 1819–1824&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Cangley, P.; Passfield, L.; Carter, H.; Bailey, M. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The Effect of Variable Gradients on Pacing in Cycling Time-Trials.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 32 (02), S. 132–136&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Carpes, F.P.; Rossato, M.; Faria, I.E.; Bolli Mota, C. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Bilateral pedaling asymmetry during a simulated 40-km cycling timetrial.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Med Phys Fitness 47 (1), S. 51–57&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Clark, Sally A.; Bourdon, P. C.; Schmidt, W.; Singh, B.; Cable, G.; Onus, K. J. et al. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The effect of acute simulated moderate altitude on power, performance and pacing strategies in well-trained cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 102 (1), S. 45–55&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Clark, Sally A.; Quod, M. J.; Clark, M. A.; Martin, D. T.; Saunders, P. U.; Gore, C. J. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Time course of haemoglobin mass during 21 days live high:train low simulated altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 106 (3), S. 399–406&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Clark, S.K.; Johnson, Thomas M. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Selenium stable isotope investigation into selenium biogeochemical cycling in a lacustrine environment: Sweitzer Lake, Colorado.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Environ. Qual. 39 (6), S. 2200–2210&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Coleman, D.A.; Wiles, J.D.; Nunn, M.; Smith, M.F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reliability of sprint test indices in well-trained cyclists. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (5), S. 383–387&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Doherty, M.; Balmer, J.; Davison, R.C.R.; Robinson, L.; Smith, P.M. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reliability of a combined 3-min constant load and performance cycling test.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 24 (5), S. 366–371&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Duc, S.; Betik, A-C; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| EMG activity does not change during a time trial in competitive cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (2), S. 145–150&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Duc, S.; Villerius, V.; Bertucci, W.; Pernin, J.N.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Muscular activity level during pedalling is not affected by crank inertial load.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 95 (2-3), S. 260–264&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Duc, S.; Villerius, V.; Bertucci, W.; Grappe, F. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and reproducibility of the ErgomoPro power meter compared with the SRM and Powertap power meters.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 2 (3), S. 270–281&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Eastwood, A.; Sharpe, K.; Bourdon, P.C.; Woolford, S.M.; Saunders, P.U.; Robertson, E.Y. et al. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Within-subject variation in hemoglobin mass in elite athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 44 (4), S. 725–732&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Ebert, T.R.; Martin, D.T.; McDonald, W.; Victor, J.; Plummer, J.; Withers, R.T. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Power output during women's World Cup road cycle racing.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 95 (5-6), S. 529–536&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ebert, T.R.; Martin, D.T.; Stephens, B.; Withers, R.T. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Power output during a professional men's road-cycling tour.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 1 (4), S. 324–335&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Emonson, D. L.; Aminuddin, A. H.; Wight, R. L.; Scroop, G. C.; Gore, C. J. (1997)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Training-induced increases in sea level VO2max and endurance are not enhanced by acute hypobaric exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 76 (1), S. 8–12&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Faiss, R.; Praz, M.; Meichtry, A.; Gobelet, C.; Deriaz, O. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The effect of mountain bike suspensions on vibrations and off-road uphill performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Med Phys Fitness 47 (2), S. 151–158&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Fu, Qi; Townsend, N.E.; Shiller, S.M.; Martini, E.R.; Okazaki, K.; Shibata, S. et al. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Intermittent hypobaric hypoxia exposure does not cause sustained alterations in autonomic control of blood pressure in young athletes. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Am. J. Physiol. Regul. Integr. Comp. Physiol. 292 (5), S. R1977-84&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gardner, A.S.; Martin, J.C.; Martin, D.T.; Barras, M.; Jenkins, D.G. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Maximal torque- and power-pedaling rate relationships for elite sprint cyclists in laboratory and field tests. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 101 (3), S. 287–292&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gardner, A.S.; Martin, D.T.; Jenkins, D.G.; Dyer, I.; van Eiden, J.; Barras, M.; Martinm, J.C. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Velocity-specific fatigue: quantifying fatigue during variable velocity cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Med Sci Sports Exerc 41 (4), S. 904–911&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gardner, A.S.; Stephens, S.; Martin, D.T.; Lawton, E.; Lee, H.; Jenkins, D. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Accuracy of SRM and power tap power monitoring systems for bicycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 36 (7), S. 1252–1258&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Garvican, L.A.; Hammond, K.; Varley, Matthew C.; Gore, C.J.; Billaut, F.; Aughey, R.J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Lower Running Performance and Exacerbated Fatigue in Soccer Played at 1600 m. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Garvican, L.A.; Martin, D.T.; Clark, S.A.; Schmidt, W.F.; Gore, C.J. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Variability of erythropoietin response to sleeping at simulated altitude: a cycling case study. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 2 (3), S. 327–331.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Garvican, L.A.; Pottgiesser, T.; Martin, D.T.; Schumacher, Y.O.; Barras, M.; Gore, C.J. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The contribution of haemoglobin mass to increases in cycling performance induced by simulated LHTL. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 111 (6), S. 1089–1101&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Garvican, L.A.; Saunders, P.U.; Pyne, D.B.; Martin, D.T.; Robertson, E.Y.; Gore, C.J. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Hemoglobin mass response to simulated hypoxia &amp;quot;blinded&amp;quot; by noisy measurement? &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 112 (10), S. 1797-8; author reply 1799&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Giacomoni, M.; Billaut, F.; Falgairette, G. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effects of the Time of Day on Repeated All-Out Cycle Performance and Short-Term Recovery Patterns. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 27 (6), S. 468–474&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| González-Haro, C.; Galilea B., P.A.; Soria, M.; Drobnic, F.; Escanero, J.F. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Comparison of nine theoretical models for estimating the mechanical power output in cycling. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Br J Sports Med 41 (8), S. 506-9; discussion 509&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| González-Haro, C.; Galilea, P.A.; Escanero, J.F. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Comparison of different theoretical models estimating peak power output and maximal oxygen uptake in trained and elite triathletes and endurance cyclists in the velodrome. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Sci 26 (6), S. 591–601&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Goosey-Tolfrey, V.; Castle, P.; Webborn, N.; Abel, T. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Aerobic capacity and peak power output of elite quadriplegic games players.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Br J Sports Med 40 (8), S. 684–687&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gordon, R.S.; Franklin, K.L.; Davies, B.; Baker, J.S. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Further mechanical considerations between polar and SRM mobile ergometer systems during laboratory-based high-intensity, intermittent cycling activity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Res Sports Med 15 (4), S. 241–247&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, Christopher John; Clark, Sally A.; Saunders, Philo U. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Nonhematological mechanisms of improved sea-level performance after hypoxic exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 39 (9), S. 1600–1609&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A. G.; Aughey, R. J.; Martin, D. T.; Ashenden, M. J.; Clark, S. A. et al. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Live high:train low increases muscle buffer capacity and submaximal cycling efficiency.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Acta Physiol. Scand. 173 (3), S. 275–286&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A. G.; Burge, C. M.; Telford, R. D. (1997)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| VO2max and haemoglobin mass of trained athletes during high intensity training.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 18 (6), S. 477–482&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore C.J.; Hahn A.G.; Scroop G.C.; Watson D.B.; Norton K.I.; Wood R.J.; Campbell D.P. (1996 )&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Increased arterial desaturation in trained cyclists during maximal exercise at 580 m altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Physiol 80(6), S. 2204-10&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A.; Rice, A.; Bourdon, P.; Lawrence, S.; Walsh, C. et al. (1998)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Altitude training at 2690m does not increase total haemoglobin mass or sea level VO2max in world champion track cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 1 (3), S. 156–170&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A. G. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Letter to the editors - Re: Heinicke K, Heinicke I, Schmidt W, Wolfarth B. A three-week traditional altitude training increases hemoglobin mass and red cell volume in elite biathlon athletes. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (6), S. 504-5; author reply 506-7&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore C.J.; Little S.C.; Hahn A.G.; Scroop G.C.; Norton K.I.; Bourdon P.C.; Woolford (1997)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reduced performance of male and female athletes at 580 m altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 75(2), S. 136-43&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; McSharry, P. E.; Hewitt, A. J.; Saunders, P. U. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Preparation for football competition at moderate to high altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Scand J Med Sci Sports 18 Suppl 1, S. 85–95&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, Christopher J.; Rodríguez, Ferran A.; Truijens, Martin J.; Townsend, Nathan E.; Stray-Gundersen, James; Levine, Benjamin D. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Increased serum erythropoietin but not red cell production after 4 wk of intermittent hypobaric hypoxia (4,000-5,500 m).&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 101 (5), S. 1386–1393&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gough, C. E.; Sharpe, K.; Garvican, L. A.; Anson, J. M.; Saunders, P. U.; Gore, C. J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The effects of injury and illness on haemoglobin mass.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 34 (9), S. 763–769&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gough, C.E.; Saunders, P.U.; Fowlie, J.; Savage, B.; Pyne, D.B.; Anson, J.M. et al. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Influence of altitude training modality on performance and total haemoglobin mass in elite swimmers.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 112 (9), S. 3275–3285&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Groslambert, A.; Grappe, F.; Bertucci, W.; Perrey, S.; Girard, A.J.; Rouillon, J.D. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| A perceptive individual time trial performed by triathletes to estimate the anaerobic threshold. A preliminary study.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Med Phys Fitness 44 (2), S. 147–156&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Haakonssen, Eric C.; Martin, David T.; Burke, Louise M.; Jenkins, David G. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Energy expenditure of constant- and variable-intensity cycling: power meter estimates. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 45 (9), S. 1833–1840&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hahn, A. G.; Gore, C. J. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The effect of altitude on cycling performance: a challenge to traditional concepts. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 31 (7), S. 533–557&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hahn, A. G.; Gore, C. J.; Martin, D. T.; Ashenden, M. J.; Roberts, A. D.; Logan, P. A. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Hahn, A. G.; Gore, C. J.; Martin, D. T.; Ashenden, M. J.; Roberts, A. D.; Logan, P. A. (2001) &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Comp. Biochem. Physiol., Part A Mol. Integr. Physiol. 128 (4), S. 777–789&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hajoglou, A.; Foster, C.; Koning, J.J. de; Lucia, A.; Kernozek, T.W.; Porcari, J.P. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effect of warm-up on cycle time trial performance. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 37 (9), S. 1608–1614&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Hopker, J.; Myers, S.; Jobson, S.A.; Bruce, W.; Passfield, L. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of the Wattbike cycle ergometer&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 31 (10), S. 731–736&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Hurst, H.T.; Atkins, S. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Agreement between polar and SRM mobile ergometer systems during laboratory-based high-intensity, intermittent cycling activity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 24 (8), S. 863–868&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hurst, H.T.; Atkins, S. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Power output of field-based downhill mountain biking.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 24 (10), S. 1047–1053&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Davison, R.C.; Coleman, D.A.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The validity of power output recorded during exercise performance tests using a Kingcycle air-braked cycle ergometer when compared with an SRM powermeter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 21 (3), S. 195–199&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Jobson, S.A.; Passfield, L.; Atkinson, G.; Barton, G.; Scarf, P. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The analysis and utilization of cycling training data.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 39 (10), S. 833–844&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Jobson, S.; Woodside, J.; Passfield, L.; Nevill, A. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Allometric Scaling of Uphill Cycling Performance. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (09), S. 753–757&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Joch, W.; Ückert, S. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of Whole Body Cooling of - 110 °C on the Heart Frequency in Endurance Activity and in Resting Time. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| W. Phys Rehab Kur Med  14(3), S. 146-150&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Julian, Colleen G.; Gore, Christopher J.; Wilber, Randall L.; Daniels, Jack T.; Fredericson, Michael; Stray-Gundersen, James et al. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Intermittent normobaric hypoxia does not alter performance or erythropoietic markers in highly trained distance runners.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 96 (5), S. 1800–1807&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Karsten, B.; Jobson, S.A.; Hopker, J.; Passfield, L., Beedie, C. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The 3-min Test Does not Provide a Valid Measure of Critical Power Using the SRM Isokinetic Mode.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med. Sep 10. [Epub ahead of print]&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, T. A.; Gore, C. J.; Hahn, A. G.; Hopkins, W. G.; Hawley, J. A.; McKenna, M. J. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sleep in athletes undertaking protocols of exposure to nocturnal simulated altitude at 2650 m.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 8 (2), S. 222–232&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, T. A.; Hahn, A. G.; Gore, C. J.; Martin, D. T.; Chow, C. M. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sleep quality responses to atmospheric variation: case studies of two elite female cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 6 (4), S. 436–442&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, Tahnee A.; Hahn, Allan G.; Gore, Christopher J.; Wilsmore, Bradley R.; Martin, David T.; Chow, Chin-Moi (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Respiratory events and periodic breathing in cyclists sleeping at 2,650-m simulated altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 92 (5), S. 2114–2118&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, Tahnee A.; Townsend, Nathan E.; Gore, Christopher J.; Hahn, Allan G.; Clark, Sally A.; Aughey, Robert J. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sleep disturbance at simulated altitude indicated by stratified respiratory disturbance index but not hypoxic ventilatory response.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 94 (5-6), S. 569–575&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kirkland, A.; Coleman, D.; Wiles, J.D.; Hopker, J. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of the Ergomopro powermeter.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (11), S. 913–916&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Loughlin, A.F.; Skiles, G.L.; Alberts, D.W.; Schaefer, W.H. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| An ion exchange liquid chromatography/mass spectrometry method for the determination of reduced and oxidized glutathione and glutathione conjugates in hepatocytes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Pharm Biomed Anal 26 (1), S. 131–142&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|MacIntosh, B.R.; Svedahl, K.; Kim, M. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Fatigue and optimal conditions for short-term work capacity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 92 (4-5), S. 369–375&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|MacRae HS-H; Hise, K.J.; Allen, P.J. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of front and dual suspension mountain bike systems on uphill cycling performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 32 (7), S. 1276–1280&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Mc Naughton, L.R.; Sherman, R.; Roberts, S.; Bentley, D.J. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Portable gas analyser Cosmed K4b2 compared to a laboratory based mass spectrometer system.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Med Phys Fitness 45 (3), S. 315–323&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| McDaniel, J.; Subudhi, A.; Martin, J.C. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Torso stabilization reduces the metabolic cost of producing cycling power.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Can J Appl Physiol 30 (4), S. 433–441&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|McLean, Blake D.; Buttifant, David; Gore, Christopher J.; White, Kevin; Liess, Carsten; Kemp, Justin (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Physiological and performance responses to a preseason altitude-training camp in elite team-sport athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 8 (4), S. 391–399&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Meyer, T.; Gabriel, H.H.W.; Auracher, M.; Scharhag, J.; Kindermann, W. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Metabolic profile of 4 h cycling in the field with varying amounts of carbohydrate supply.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 88 (4-5), S. 431–437&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Mijnarends, D.M.; Meijers, J.M.M.; Halfens, R.J.G.; Ter Borg, S.; Luiking, Y.C.; Verlaan, S. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of tools to measure muscle mass, strength, and physical performance in community-dwelling older people: a systematic review.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Am Med Dir Assoc 14 (3), S. 170–178&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Millet, G.P.; Tronche, C.; Fuster, N.; Candau, R. (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Level ground and uphill cycling efficiency in seated and standing positions.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Med Sci Sports Exerc 34 (10), S. 1645–1652&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Millet, G.P.; Tronche, C.; Fuster, N.; Bentley, D.J.; Candau, R. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and reliability of the Polar S710 mobile cycling powermeter.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 24 (3), S. 156–161&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Mornieux, G.; Gollhofer, A.; Stapelfeldt, B. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Muscle Coordination while Pulling up During Cycling. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 31 (12), S. 843–846&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Mornieux, G.; Stapelfeldt, B.; Gollhofer, A.; Belli, A. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effects of Pedal Type and Pull-Up Action during Cycling. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (10), S. 817–822&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Neville, V.; Pain, M.T.G.; Folland, J.P. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Aerobic power and peak power of elite America's Cup sailors. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 106 (1), S. 149–157&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Neville, V.; Pain, M.T.G.; Kantor, J.; Folland, J.P. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Influence of crank length and crank-axle height on standing armcrank (grinding) power.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 42 (2), S. 381–387&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Neville, V.; Zaher, N.; Pain, M.T.G.; Folland, J.P. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Lower limb influence on standing arm-cranking ('grinding').&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 30 (10), S. 713–718&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Neya, Mitsuo; Enoki, Taisuke; Ohiwa, Nao; Kawahara, Takashi; Gore, Christopher J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Increased hemoglobin mass and VO2max with 10 h nightly simulated altitude at 3000 m.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 8 (4), S. 366–372&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Nimmerichter, A.; Eston, R.G.; Bachl, N.; Williams, C. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Longitudinal monitoring of power output and heart rate profiles in elite cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 29 (8), S. 831–840&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Nimmerichter, A.; Williams, C.; Bachl, N.; Eston, R. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Evaluation of a field test to assess performance in elite cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 31 (3), S. 160–166&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|O’Hara, J.; Thomas, A.; Seims, A.; Cooke, C.; King, R.F.G (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reliability of a High-Intensity Endurance Cycling Test.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 33 (01), S. 18–25&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Parisotto, R.; Gore, C. J.; Hahn, A. G.; Ashenden, M. J.; Olds, T. S.; Martin, D. T. et al. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reticulocyte parameters as potential discriminators of recombinant human erythropoietin abuse in elite athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 21 (7), S. 471–479&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Paton, C.D.; Hopkins, W.G. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Tests of cycling performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 31 (7), S. 489–496&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Paton, C.D.; Hopkins, W.G. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Ergometer error and biological variation in power output in a performance test with three cycle ergometers.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 27 (6), S. 444–447&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Caillaud, C.; Thompson, M.W. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Central and Peripheral Fatigue during Passive and Exercise-Induced Hyperthermia &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med. Sci. Sports Exerc. 43 (9), S. 1657 – 1665&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Caillaud, C.; Thompson, M.W. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The role of aerobic fitness and exercise intensity on endurance performance in uncompensable heat stress conditions. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol  112, S. 1989 - 1999&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Cramer, M.N.; Chapman, P.G.; Caillaud, C.; Thompson, M.W. (2011)  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Cardiovascular strain impairs prolonged self-paced exercise in the heat. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Exp Physiol 96 (2), S. 134 - 144&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Cramer, M.N.; Chapman, P.G.; Caillaud, C.; Thompson, M.W. (2011)   &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Neuromuscular function following prolonged intense self-paced exercise in hot climatic conditions. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Physiol. 111, S. 1561 – 1569&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Perrey, S.; Grappe, F.; Girard, A.; Bringard, A.; Groslambert, A.; Bertucci, W.; Rouillon, J.D. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Physiological and metabolic responses of triathletes to a simulated 30-min time-trial in cycling at self-selected intensity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 24 (2), S. 138–143&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Pester, M.; Knorr, K.-H.; Friedrich, M.W.; Wagner, M.; Loy, A. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sulfate-reducing microorganisms in wetlands - fameless actors in carbon cycling and climate change.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Front Microbiol 3, S. 72&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Pinot, J.; Grappe, F. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The record power profile to assess performance in elite cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 32 (11), S. 839–844&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Pottgiesser, Torben; Garvican, Laura A.; Martin, David T.; Featonby, Jesse M.; Gore, Christopher J.; Schumacher, Yorck O. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Short-term hematological effects upon completion of a four-week simulated altitude camp.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Physiol Perform 7 (1), S. 79–83&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Quod, M. J.; Martin, D. T.; Martin, J. C.; Laursen, P. B. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The Power Profile Predicts Road Cycling MMP.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 31 (06), S. 397–401&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Reiser, M.; Meyer, T.; Kindermann, W.; Daugs, R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Transferability of workload measurements between three different types of ergometer.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 82 (3), S. 245–249&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Reiser, R.; Hart, C. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Cycling on Rollers: Kreitler Fan Resistance at Submaximal Levels of Effort.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (3), S. 212–216&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Richalet, J-P; Gore, C. J. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Live and/or sleep high:train low, using normobaric hypoxia.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Scand J Med Sci Sports 18 Suppl 1, S. 29–37&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Roberts, A. D.; Clark, S. A.; Townsend, N. E.; Anderson, M. E.; Gore, C. J.; Hahn, A. G. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Changes in performance, maximal oxygen uptake and maximal accumulated oxygen deficit after 5, 10 and 15 days of live high:train low altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 88 (4-5), S. 390–395&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Robertson, E.Y.; Saunders, P.U.; Pyne, D.B.; Aughey, R.J.; Anson, J.M.; Gore, C.J. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reproducibility of performance changes to simulated live high/train low altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 42 (2), S. 394–401&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Robertson, E.Y.; Saunders, P.U.; Pyne, D.B.; Gore, C.J.; Anson, J.M. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effectiveness of intermittent training in hypoxia combined with live high/train low.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| . J. Appl. Physiol. 110 (2), S. 379–387&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Rodríguez, F.A.; Truijens, M.J.; Townsend, N.E.; Stray-Gundersen, J.; Gore, C.J.; Levine, B.D. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Performance of runners and swimmers after four weeks of intermittent hypobaric hypoxic exposure plus sea level training.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 103 (5), S. 1523–1535&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Sassi, A.; Rampinini, E.; Martin, D.T.; Morelli, A. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of gradient and speed on freely chosen cadence: the key role of crank inertial load.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Biomech 42 (2), S. 171–177&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P. U.; Telford, R. D.; Pyne, D. B.; Cunningham, R. B.; Gore, C. J.; Hahn, A. G.; Hawley, J. A. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Improved running economy in elite runners after 20 days of simulated moderate-altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 96 (3), S. 931–937&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P. U.; Telford, R. D.; Pyne, D. B.; Hahn, A. G.; Gore, C. J. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Improved running economy and increased hemoglobin mass in elite runners after extended moderate altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 12 (1), S. 67–72&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P.U.; Ahlgrim, C.; Vallance, B.; Green, D.J.; Robertson, E.Y.; Clark, S.A. et al. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| An attempt to quantify the placebo effect from a three-week simulated altitude training camp in elite race walkers.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 5 (4), S. 521–534&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P.U.; Pyne, David B.; Gore, C.J. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Endurance training at altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| High Alt. Med. Biol. 10 (2), S. 135–148&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P.U.; Telford, R.D.; Pyne, D.D.; Gore, C.J.; Hahn, A.G. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Improved race performance in elite middle-distance runners after cumulative altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 4 (1), S. 134–138&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Sharpe, K.; Hopkins, W.; Emslie, K.R.; Howe, C.; Trout, G.J.; Kazlauskas, R. et al. (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Development of reference ranges in elite athletes for markers of altered erythropoiesis.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Haematologica 87 (12), S. 1248–1257&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Simons, M.; van Es, E.; Hendriksen, I. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Electrically assisted cycling: a new mode for meeting physical activity guidelines?&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 41 (11), S. 2097–2102&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Smith, M.F.; Davison, R.C.; Balmer, J.; Bird, S.R. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reliability of mean power recorded during indoor and outdoor selfpaced 40 km cycling time-trials.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 22 (4), S. 270–274&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Stapelfeldt, B.; Mornieux, G.; Oberheim, R.; Belli, A.; Gollhofer, A. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Development and evaluation of a new bicycle instrument for measurements of pedal forces and power output in cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 28 (4), S. 326–332&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Stapelfeldt, B.; Schwirtz, A.; Schumacher, Y.O.; Hillebrecht, M. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Workload demands in mountain bike racing.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 25 (4), S. 294–300&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Tomas, A.; Ross, E.Z.; Martin, J.C. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Fatigue during maximal sprint cycling: unique role of cumulative contraction cycles.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 42 (7), S. 1364–1369&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Townsend, N.E.; Gore, C.J.; Hahn, A.G.; Aughey, R.J.; Clark, S.A.; Kinsman, T.A. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Hypoxic ventilatory response is correlated with increased submaximal exercise ventilation after live high, train low.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 94 (1-2), S. 207–215&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Townsend, N.E.; Gore, C.J.; Hahn, A.G.; McKenna, M.J.; Aughey, R.J.; Clark, S.A. et al. (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Living high-training low increases hypoxic ventilatory response of well-trained endurance athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 93 (4), S. 1498–1505&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Truijens, M.J.; Rodríguez, F.A.; Townsend, N.E.; Stray-Gundersen, J.; Gore, C.J.; Levine, B.D. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The effect of intermittent hypobaric hypoxic exposure and sea level training on submaximal economy in well-trained swimmers and runners.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 104 (2), S. 328–337&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Vaile, J.; Halson, S.; Gill, N.; Dawson, B. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effect of Hydrotherapy on Recovery from Fatigue.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 29 (7), S. 539–544&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| van der Woude, L.H.V.; Horstman, A.; Faas, P.; Mechielsen, S.; Bafghi, H.A.; Koning, J.J. de (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Power output and metabolic cost of synchronous and asynchronous submaximal and peak level hand cycling on a motor driven treadmill in able-bodied male subjects.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Med Eng Phys 30 (5), S. 574–580&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Villerius, V.; Duc, S.; Grappe, F. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Physiological and Neuromuscular Responses of Competitive Cyclists during a Simulated Self-Paced Interval Training Session.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (09), S. 770–777&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Vogt, S.; Heinrich, L.; Schumacher, Y. O.; Blum, A.; Roecker, K.; Dickhuth, H.-H.; Schmid, A. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Power output during stage racing in professional road cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 38 (1), S. 147–151&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Vogt, S.; Roecker, K.; Schumacher, Y. O.; Pottgiesser, T.; Dickhuth, H-H; Schmid, A.; Heinrich, L. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Cadence-power-relationship during decisive mountain ascents at the Tour de France.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 29 (3), S. 244–250&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Vogt, S.; Schumacher, Y.O.; Blum, A.; Roecker, K.; Dickhuth, H.-H.; Schmid, A.; Heinrich, L. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Cycling power output produced during flat and mountain stages in the Giro d'Italia: a case study.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Sci 25 (12), S. 1299–1305&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Vogt, S.; Schumacher, Y. O.; Roecker, K.; Dickhuth, H-H; Schoberer, U.; Schmid, A.; Heinrich, L. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Power Output during the Tour de France.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 28 (9), S. 756–761&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wahl, P.; Mathes, S.; Köhler, K.; Achtzehn, S.; Bloch, W.; Mester, J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Acute Metabolic, Hormonal, and Psychological Responses to Different Endurance Training Protocols.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Horm Metab Res 45 (11), S. 827–833&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wahl, P.; Schmidt, A.; deMarees, M.; Achtzehn, S.; Bloch, W.; Mester, J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Responses of Angiogenic Growth Factors to Exercise, to Hypoxia and to Exercise under Hypoxic Conditions.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 34 (02), S. 95–100&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wiedemann, M. S. F.; Bosquet, L. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Anaerobic Work Capacity Derived from Isokinetic and Isoinertial Cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 31 (02), S. 89–94&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wilson, M.G.; Lane, A.M.; Beedie, C.J.; Farooq, A. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Influence of accurate and inaccurate 'split-time' feedback upon 10-mile time trial cycling performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 112 (1), S. 231–236&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wooles, A.L.; Robinson, A.J.; Keen, P.S. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|A Static Method for Obtaining a Calibration Factor for SRM Bicycle Power Cranks.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sports Engineering 8 (3), S. 137-144&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Internationale_Literatur_zum_SRM-Ergometer&amp;diff=2014</id>
		<title>Internationale Literatur zum SRM-Ergometer</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Internationale_Literatur_zum_SRM-Ergometer&amp;diff=2014"/>
				<updated>2016-06-29T08:41:12Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{languages&lt;br /&gt;
|de=Internationale Literatur zum SRM-Ergometer&lt;br /&gt;
|en=International publications on the SRM Ergometer&lt;br /&gt;
|cn=International publications on the SRM Ergometer&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
In der folgenden Tabelle sind  diverese Sammlungen an Publikationen zu verschiedenen Themen als PDF-Dateien verlinkt.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot;&lt;br /&gt;
|+ style=&amp;quot;padding-bottom:1em&amp;quot; | Publikationen des SRM-Ergometers &lt;br /&gt;
|- class=&amp;quot;hintergrundfarbe6&amp;quot;&lt;br /&gt;
!style=&amp;quot;width:60%&amp;quot;| Publikationen!! style=&amp;quot;width:30%&amp;quot;| Letztes Update&lt;br /&gt;
|-&lt;br /&gt;
| [[Media:SRM_Scientific_Publications_06-2016.pdf|SRM Scientific Publications]]&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| Juni 2016 &lt;br /&gt;
|-&lt;br /&gt;
| [[Media:Torque_publications_2015.pdf|Torque Publications]]&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| Januar 2015&lt;br /&gt;
|-&lt;br /&gt;
| [[Media:Eccentric_Chainrings_2015.pdf|Eccentric Chainrings Publications]]&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| April 2015&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* Abbiss, C. R., Quod, M. J., Levin, G., Martin, D. T. &amp;amp; Laursen, P. B. (2009): Accuracy of the Velotron ergometer and SRM power meter. International journal of sports medicine, 30 (2), 107-112. doi: 10.1055/s-0028-1103285.&lt;br /&gt;
&lt;br /&gt;
* Abbiss, C. R., Quod, M. J., Martin, D. T., Netto, K. J., Nosaka, K., Lee, H. et al. (2006): Dynamic pacing strategies during the cycle phase of an Ironman triathlon. Medicine and science in sports and exercise, 38 (4), 726-734. doi: 10.1249/01.mss.0000210202.33070.55.&lt;br /&gt;
&lt;br /&gt;
* Abel, T., Burkett, B., Schneider, S., Lindschulten, R. &amp;amp; Strüder, H. K. (2010): The exercise profile of an ultra-long handcycling race: the Styrkeprøven experience. Spinal cord, 48 (12), 894-898. doi: 10.1038/sc.2010.40.&lt;br /&gt;
&lt;br /&gt;
* Antonutto, G., Capelli, C., Girardis, M., Zamparo, P. &amp;amp; Di Prampero, P. E. (1999): Effects of microgravity on maximal power of lower limbs during very short efforts in humans. Journal of applied physiology (Bethesda, Md, 86 (1), 85-92.&lt;br /&gt;
&lt;br /&gt;
* Arkesteijn, M., Hopker, J., Jobson, S. &amp;amp; Passfield, L. (2013): The Effect of Turbo Trainer Cycling on Pedalling Technique and Cycling Efficiency. International journal of sports medicine, 34 (06), 520-525. doi: 10.1055/s-0032-1327658.&lt;br /&gt;
&lt;br /&gt;
* Ashenden, M. J., Gore, C. J., Burge, C. M., Clough, M. L., Bourdon, P. C., Dobson, G. P. et al. (1999): Skin-prick blood samples are reliable for estimating Hb mass with the CO-dilution technique. European journal of applied physiology and occupational physiology, 79 (6), 535-537.&lt;br /&gt;
&lt;br /&gt;
* Ashenden, M. J., Gore, C. J., Dobson, G. P., Boston, T. T., Parisotto, R., Emslie, K. R. et al. (2000): Simulated moderate altitude elevates serum erythropoietin but does not increase reticulocyte production in well-trained runners. European journal of applied physiology, 81 (5), 428-435. doi: 10.1007/s004210050064.&lt;br /&gt;
* &lt;br /&gt;
* Ashenden, M. J., Gore, C. J., Dobson, G. P. &amp;amp; Hahn, A. G. (1999): &amp;quot;Live high, train low&amp;quot; does not change the total haemoglobin mass of male endurance athletes sleeping at a simulated altitude of 3000 m for 23 nights. European journal of applied physiology and occupational physiology, 80 (5), 479-484.&lt;br /&gt;
&lt;br /&gt;
* Ashenden, M. J., Gore, C. J., Martin, D. T., Dobson, G. P. &amp;amp; Hahn, A. G. (1999): Effects of a 12-day &amp;quot;live high, train low&amp;quot; camp on reticulocyte production and haemoglobin mass in elite female road cyclists. European journal of applied physiology and occupational physiology, 80 (5), 472-478.&lt;br /&gt;
&lt;br /&gt;
* Ashenden, M. J., Hahn, A. G., Martin, D. T., Logan, P., Parisotto, R. &amp;amp; Gore, C. J. (2001): A comparison of the physiological response to simulated altitude exposure and r-HuEpo administration. Journal of sports sciences, 19 (11), 831-837. doi: 10.1080/026404101753113778.&lt;br /&gt;
&lt;br /&gt;
* Ashenden, M. J., Gore, C. J., Parisotto, R., Sharpe, K., Hopkins, W. G. &amp;amp; Hahn, A. G. (2003): Effect of altitude on second-generation blood tests to detect erythropoietin abuse by athletes. Haematologica, 88 (9), 1053-1062.&lt;br /&gt;
&lt;br /&gt;
* Aughey, R. J., Clark, S. A., Gore, C. J., Townsend, N. E., Hahn, A. G., Kinsman, T. A. et al. (2006): Interspersed normoxia during live high, train low interventions reverses an early reduction in muscle Na+, K +ATPase activity in well-trained athletes. European journal of applied physiology, 98 (3), 299-309. doi: 10.1007/s00421-006-0280-z.&lt;br /&gt;
&lt;br /&gt;
* Aughey, R. J., Gore, C. J., Hahn, A. G., Garnham, A. P., Clark, S. A., Petersen, A. C. et al. (2005): Chronic intermittent hypoxia and incremental cycling exercise independently depress muscle in vitro maximal Na+-K+-ATPase activity in well-trained athletes. Journal of applied physiology (Bethesda, Md. : 1985), 98 (1), 186-192. doi: 10.1152/japplphysiol.01335.2003.&lt;br /&gt;
&lt;br /&gt;
* Austin, N., Nilwik, R. &amp;amp; Herzog, W. (2010): In vivo operational fascicle lengths of vastus lateralis during sub-maximal and maximal cycling. Journal of biomechanics, 43 (12), 2394-2399. doi: 10.1016/j.jbiomech.2010.04.016.&lt;br /&gt;
&lt;br /&gt;
* Balmer, J., Davison, R. C. &amp;amp; Bird, S. R. (2000): Peak power predicts performance power during an outdoor 16.1-km cycling time trial. Medicine and science in sports and exercise, 32 (8), 1485-1490.&lt;br /&gt;
&lt;br /&gt;
* Balmer, J., Davison, R. C. &amp;amp; Bird, S. R. (2000): Reliability of an air-braked ergometer to record peak power during a maximal cycling test. Medicine and science in sports and exercise, 32 (10), 1790-1793.Balmer, Davison et al. 2000 – The validity of power output&lt;br /&gt;
&lt;br /&gt;
* Balmer, J., Davison, R. C., Coleman, D. A. &amp;amp; Bird, S. R. (2000): The validity of power output recorded during exercise performance tests using a Kingcycle air-braked cycle ergometer when compared with an SRM powermeter. International journal of sports medicine, 21 (3), 195-199. doi: 10.1055/s-2000-9466.&lt;br /&gt;
&lt;br /&gt;
* Balmer, J., Bird, S., Davison, R. C. R., Doherty, M. &amp;amp; Smith, P. (2004): Mechanically braked Wingate powers: agreement between SRM, corrected and conventional methods of measurement. Journal of sports sciences, 22 (7), 661-667. doi: 10.1080/02640410310001655831.&lt;br /&gt;
&lt;br /&gt;
* Balmer, J., Bird, S., Davison, R. &amp;amp; Lucia, A. (2008): Effect of age on 16.1-km time-trial performance. Journal of sports sciences, 26 (2), 197-206. doi: 10.1080/02640410701446901.&lt;br /&gt;
&lt;br /&gt;
* Barratt, P. (2008): SRM Torque Analysis of Standing Starts in Track Cycling (P85). In  The Engineering of Sport 7 (Volume 1, S. 443-448).&lt;br /&gt;
&lt;br /&gt;
* Bassett, D. R., Kyle, C. R., Passfield, L., Broker, J. P. &amp;amp; Burke, E. R. (1999): Comparing cycling world hour records, 1967-1996: modeling with empirical data. Medicine and science in sports and exercise, 31 (11), 1665-1676.&lt;br /&gt;
&lt;br /&gt;
* Bentley, D. J., McNaughton, L. R., Thompson, D., Vleck, V. E. &amp;amp; Batterham, A. M. (2001): Peak power output, the lactate threshold, and time trial performance in cyclists. Medicine and science in sports and exercise, 33 (12), 2077-2081.&lt;br /&gt;
* &lt;br /&gt;
* Bertucci, W., Crequy, S. &amp;amp; Chiementin, X. (2012). Validity and Reliability of the G-Cog BMX Powermeter. International journal of sports medicine. doi: 10.1055/s-0031-1301319.&lt;br /&gt;
&lt;br /&gt;
* Bertucci, W., Duc, S., Villerius, V. &amp;amp; Grappe, F. (2005): Validity and reliability of the Axiom PowerTrain cycle ergometer when compared with an SRM powermeter. International journal of sports medicine, 26 (1), 59-65. doi: 10.1055/s-2004-817855.&lt;br /&gt;
* &lt;br /&gt;
* Bertucci, W., Duc, S., Villerius, V., Pernin, J. N. &amp;amp; Grappe, F. (2005): Validity and reliability of the PowerTap mobile cycling powermeter when compared with the SRM Device. International journal of sports medicine, 26 (10), 868-873. doi: 10.1055/s-2005-837463.&lt;br /&gt;
* &lt;br /&gt;
* Bertucci, W., Taiar, R. &amp;amp; Grappe, F. (2005): Differences between sprint tests under laboratory and actual cycling conditions. The Journal of sports medicine and physical  fitness, 45 (3), 277-283.&lt;br /&gt;
* &lt;br /&gt;
* Bertucci, W., Grappe, F., Girard, A., Betik, A. &amp;amp; Rouillon, J. D. (2005): Effects on the crank torque profile when changing pedalling cadence in level ground and uphill road cycling. Journal of biomechanics, 38 (5), 1003-1010. doi: 10.1016/j.jbiomech.2004.05.037.&lt;br /&gt;
* &lt;br /&gt;
* Bertucci, W., Grappe, F. &amp;amp; Groslambert, A. (2007): Laboratory versus outdoor cycling conditions: differences in pedaling biomechanics. Journal of applied biomechanics, 23 (2), 87-92.&lt;br /&gt;
* &lt;br /&gt;
* Billaut, F., Gore, C. J. &amp;amp; Aughey, R. J. (2012): Enhancing team-sport athlete performance: is altitude training relevant? Sports medicine (Auckland, N.Z.), 42 (9), 751-767. doi: 10.2165/11634050-000000000-00000.&lt;br /&gt;
* &lt;br /&gt;
* Brickley, G., Dekerle, J., Hammond, A., Pringle, J. &amp;amp; Carter, H. (2007): Assessment of Maximal Aerobic Power and Critical Power in a Single 90-s Isokinetic All-Out Cycling Test. International journal of sports medicine, 28 (5), 414-419. doi: 10.1055/s-2006-924513.&lt;br /&gt;
* &lt;br /&gt;
* Broker, J. P., Kyle, C. R. &amp;amp; Burke, E. R. (1999): Racing cyclist power requirements in the 4000-m individual and team pursuits. Medicine and science in sports and exercise, 31 (11), 1677-1685.&lt;br /&gt;
* &lt;br /&gt;
* Brosnan, M. J., Martin, D. T., Hahn, A. G., Gore, C. J. &amp;amp; Hawley, J. A. (2000): Impaired interval exercise responses in elite female cyclists at moderate simulated altitude. Journal of applied physiology (Bethesda, Md. : 1985), 89 (5), 1819-1824.&lt;br /&gt;
* &lt;br /&gt;
* Cangley, P., Passfield, L., Carter, H. &amp;amp; Bailey, M. (2011): The Effect of Variable Gradients on Pacing in Cycling Time-Trials. International journal of sports medicine, 32 (02), 132-136. doi: 10.1055/s-0030-1268440.&lt;br /&gt;
* &lt;br /&gt;
* Carpes, F. P., Rossato, M., Faria, I. E. &amp;amp; Bolli Mota, C. (2007): Bilateral pedaling asymmetry during a simulated 40-km cycling time-trial. The Journal of sports medicine and physical fitness, 47 (1), 51-57.&lt;br /&gt;
* &lt;br /&gt;
* Clark, S. A., Bourdon, P. C., Schmidt, W., Singh, B., Cable, G., Onus, K. J. et al. (2007): The effect of acute simulated moderate altitude on power, performance and pacing strategies in well-trained cyclists. European journal of applied physiology, 102 (1), 45-55. doi: 10.1007/s00421-007-0554-0.&lt;br /&gt;
* &lt;br /&gt;
* Clark, S. A., Quod, M. J., Clark, M. A., Martin, D. T., Saunders, P. U. &amp;amp; Gore, C. J. (2009): Time course of haemoglobin mass during 21 days live high:train low simulated altitude. European journal of applied physiology, 106 (3), 399-406. doi: 10.1007/s00421-009-1027-4.&lt;br /&gt;
* &lt;br /&gt;
* Clark, S. K. &amp;amp; Johnson, T. M. (2010): Selenium stable isotope investigation into selenium biogeochemical cycling in a lacustrine environment: Sweitzer Lake, Colorado. Journal of environmental quality, 39 (6), 2200-2210.&lt;br /&gt;
* &lt;br /&gt;
* Coleman, D. A., Wiles, J. D., Nunn, M. &amp;amp; Smith, M. F. (2005): Reliability of sprint test indices in well-trained cyclists. International journal of sports medicine, 26 (5), 383-387. doi: 10.1055/s-2004-821226.&lt;br /&gt;
* &lt;br /&gt;
* Doherty, M., Balmer, J., Davison, R. C. R., Robinson, L. &amp;amp; Smith, P. M. (2003): Reliability of a combined 3-min constant load and performance cycling test. International journal of sports medicine, 24 (5), 366-371. doi: 10.1055/s-2003-40700.&lt;br /&gt;
* &lt;br /&gt;
* Duc, S., Betik, A.-C. &amp;amp; Grappe, F. (2005): EMG activity does not change during a time trial in competitive cyclists. International journal of sports medicine, 26 (2), 145-150. doi: 10.1055/s-2004-817922.&lt;br /&gt;
* &lt;br /&gt;
* Duc, S., Villerius, V., Bertucci, W. &amp;amp; Grappe, F. (2007): Validity and reproducibility of the ErgomoPro power meter compared  with the SRM and Powertap power meters. International journal of sports physiology and performance, 2 (3), 270-281.&lt;br /&gt;
* &lt;br /&gt;
* Duc, S., Villerius, V., Bertucci, W., Pernin, J. N. &amp;amp; Grappe, F. (2005): Muscular activity level during pedalling is not affected by crank inertial load. European journal of applied physiology, 95 (2-3), 260-264. doi: 10.1007/s00421-005-1401-9.&lt;br /&gt;
* &lt;br /&gt;
* Duc, S., Villerius, V., Bertucci, W. &amp;amp; Grappe, F. (2007): Validity and reproducibility of the ErgomoPro power meter compared with the SRM and Powertap power meters. International journal of sports physiology and performance, 2 (3), 270-281.&lt;br /&gt;
* &lt;br /&gt;
* Eastwood, A., Sharpe, K., Bourdon, P. C., Woolford, S. M., Saunders, P. U., Robertson, E. Y. et al. (2012): Within-subject variation in hemoglobin mass in elite athletes. Medicine and science in sports and exercise, 44 (4), 725-732. doi: 10.1249/MSS.0b013e318238ea7f.&lt;br /&gt;
* &lt;br /&gt;
* Ebert, T. R., Martin, D. T., McDonald, W., Victor, J., Plummer, J. &amp;amp; Withers, R. T. (2005): Power output during women's World Cup road cycle racing. European journal of applied physiology, 95 (5-6), 529-536. doi: 10.1007/s00421-005-0039-y.&lt;br /&gt;
* &lt;br /&gt;
* Ebert, T. R., Martin, D. T., Stephens, B. &amp;amp; Withers, R. T. (2006): Power output during a professional men's road-cycling tour. International journal of sports physiology and performance, 1 (4), 324-335.&lt;br /&gt;
* &lt;br /&gt;
* Emonson, D. L., Aminuddin, A. H., Wight, R. L., Scroop, G. C. &amp;amp; Gore, C. J. (1997): Training-induced increases in sea level VO2max and endurance are not enhanced by acute hypobaric exposure. European journal of applied physiology and occupational physiology, 76 (1), 8-12.&lt;br /&gt;
* &lt;br /&gt;
* Faiss, R., Praz, M., Meichtry, A., Gobelet, C. &amp;amp; Deriaz, O. (2007): The effect of mountain bike suspensions on vibrations and off-road uphill performance. The Journal of sports medicine and physical fitness, 47 (2), 151-158.&lt;br /&gt;
* &lt;br /&gt;
* Frese, S., Valdivieso, P., Jaecker, V. C., Harms, S. A., Konou, T. M., Tappe, K. A. et al. (2016): Expression of Metabolic and Myogenic Factors during two Competitive Seasons in Elite Junior Cyclists. Deutsche Zeitschrift für Sportmedizin, 2016 (06), 150-158. doi: 10.5960/dzsm.2016.239.&lt;br /&gt;
* &lt;br /&gt;
* Fu, Q., Townsend, N. E., Shiller, S. M., Martini, E. R., Okazaki, K., Shibata, S. et al. (2007): Intermittent hypobaric hypoxia exposure does not cause sustained alterations in autonomic control of blood pressure in young athletes. American journal of physiology. Regulatory, integrative and comparative physiology, 292 (5), R1977-84. doi: 10.1152/ajpregu.00622.2006.&lt;br /&gt;
* &lt;br /&gt;
* Gardner, A. S., Martin, D. T., Jenkins, D. G., Dyer, I., van Eiden, J., Barras, M. et al. (2009): Velocity-specific fatigue: quantifying fatigue during variable velocity cycling. Medicine and science in sports and exercise, 41 (4), 904-911. doi: 10.1249/MSS.0b013e318190c2cc.&lt;br /&gt;
* &lt;br /&gt;
* Gardner, A. S., Martin, J. C., Martin, D. T., Barras, M. &amp;amp; Jenkins, D. G. (2007): Maximal torque- and power-pedaling rate relationships for elite sprint cyclists in laboratory and field tests. European journal of applied physiology, 101 (3), 287-292. doi: 10.1007/s00421-007-0498-4.&lt;br /&gt;
* &lt;br /&gt;
* Gardner, A. S., Stephens, S., Martin, D. T., Lawton, E., Lee, H. &amp;amp; Jenkins, D. (2004): Accuracy of SRM and power tap power monitoring systems for bicycling. Medicine and science in sports and exercise, 36 (7), 1252-1258.&lt;br /&gt;
* &lt;br /&gt;
* Garvican, L. A., Hammond, K., Varley, M. C., Gore, C. J., Billaut, F. &amp;amp; Aughey, R. J. (2013): Lower Running Performance and Exacerbated Fatigue in Soccer Played at 1600 m. International journal of sports physiology and performance.&lt;br /&gt;
* &lt;br /&gt;
* Garvican, L. A., Martin, D. T., Clark, S. A., Schmidt, W. F. &amp;amp; Gore, C. J. (2007): Variability of erythropoietin response to sleeping at simulated altitude: a cycling case study. International journal of sports physiology and performance, 2 (3), 327-331.&lt;br /&gt;
* &lt;br /&gt;
* Garvican, L. A., Pottgiesser, T., Martin, D. T., Schumacher, Y. O., Barras, M. &amp;amp; Gore, C. J. (2011): The contribution of haemoglobin mass to increases in cycling performance induced by simulated LHTL. European journal of applied physiology, 111 (6), 1089-1101. doi: 10.1007/s00421-010-1732-z.&lt;br /&gt;
* &lt;br /&gt;
* Garvican, L. A., Saunders, P. U., Pyne, D. B., Martin, D. T., Robertson, E. Y. &amp;amp; Gore, C. J. (2012): Hemoglobin mass response to simulated hypoxia &amp;quot;blinded&amp;quot; by noisy measurement? Journal of applied physiology (Bethesda, Md. : 1985), 112 (10), 1797-8; author reply 1799. doi: 10.1152/japplphysiol.00212.2012.&lt;br /&gt;
* &lt;br /&gt;
* Giacomoni, M., Billaut, F. &amp;amp; Falgairette, G. (2006): Effects of the Time of Day on Repeated All-Out Cycle Performance and Short-Term Recovery Patterns. International journal of sports medicine, 27 (6), 468-474. doi: 10.1055/s-2005-865822.&lt;br /&gt;
* &lt;br /&gt;
* González-Haro, C., Galilea, P. A. &amp;amp; Escanero, J. F. (2008):Comparison of different theoretical models estimating peak power output and maximal oxygen uptake in trained and elite triathletes and endurance cyclists in the velodrome. Journal of sports sciences, 26 (6), 591-601. doi: 10.1080/02640410701646245.&lt;br /&gt;
* &lt;br /&gt;
* González-Haro, C., Galilea Ballarini, P. A., Soria, M., Drobnic, F. &amp;amp; Escanero, J. F. (2007): Comparison of nine theoretical models for estimating the mechanical power output in cycling. British journal of sports medicine, 41 (8), 506-9; discussion 509. doi: 10.1136/bjsm.2006.034934.&lt;br /&gt;
* &lt;br /&gt;
* Goosey-Tolfrey, V., Castle, P., Webborn, N. &amp;amp; Abel, T. (2006). Aerobic capacity and peak power output of elite quadriplegic games players. British journal of sports medicine, 40 (8), 684-687. doi: 10.1136/bjsm.2006.026815.&lt;br /&gt;
* &lt;br /&gt;
* Gordon, R. S., Franklin, K. L., Davies, B. &amp;amp; Baker, J. S. (2007): Further mechanical considerations between polar and SRM mobile ergometer systems during laboratory-based high-intensity, intermittent cycling activity. Research in sports medicine (Print), 15 (4), 241-247. doi: 10.1080/15438620701525540.&lt;br /&gt;
* &lt;br /&gt;
* Gore, C. J., Hahn, A., Rice, A., Bourdon, P., Lawrence, S., Walsh, C. et al. (1998): Altitude training at 2690m does not increase total haemoglobin mass or sea level VO2max in world champion track cyclists. Journal of science and medicine in sport / Sports Medicine Australia, 1 (3), 156-170.&lt;br /&gt;
* &lt;br /&gt;
* Gore, C. J. &amp;amp; Hahn, A. G. (2005): Letter to the editors - Re: Heinicke K, Heinicke I, Schmidt W, Wolfarth B. A three-week traditional altitude training increases hemoglobin mass and red cell volume in elite biathlon athletes. Int J Sports Med 2005; 26: 350-355. International journal of sports medicine, 26 (6), 504-5; author reply 506-7. doi: 10.1055/s-2005-865832.&lt;br /&gt;
* &lt;br /&gt;
* Gore, C. J., Hahn, A. G., Aughey, R. J., Martin, D. T., Ashenden, M. J., Clark, S. A. et al. (2001): Live high:train low increases muscle buffer capacity and submaximal cycling efficiency. Acta physiologica Scandinavica, 173 (3), 275-286. doi: 10.1046/j.1365-201X.2001.00906.x.&lt;br /&gt;
* &lt;br /&gt;
* Gore, C. J., Hahn, A. G., Burge, C. M. &amp;amp; Telford, R. D. (1997): VO2max and haemoglobin mass of trained athletes during high intensity training. International journal of sports medicine, 18 (6), 477-482. doi: 10.1055/s-2007-972667.&lt;br /&gt;
* &lt;br /&gt;
* Gore, C. J., Hahn, A. G., Scroop, G. C., Watson, D. B., Norton, K. I., Wood, R. J. et al. (1996): Increased arterial desaturation in trained cyclists during maximal exercise at 580 m altitude. Journal of applied physiology (Bethesda, Md. : 1985), 80 (6), 2204-2210.&lt;br /&gt;
* &lt;br /&gt;
* Gore, C. J., Little, S. C., Hahn, A. G., Scroop, G. C., Norton, K. I., Bourdon, P. C. et al. (1997): Reduced performance of male and female athletes at 580 m altitude. European journal of applied physiology and occupational physiology, 75 (2), 136-143.&lt;br /&gt;
* &lt;br /&gt;
* Gore, C. J., McSharry, P. E., Hewitt, A. J. &amp;amp; Saunders, P. U. (2008): Preparation for football competition at moderate to high altitude. Scandinavian journal of medicine &amp;amp; science in sports, 18 Suppl 1, 85-95. doi: 10.1111/j.1600-0838.2008.00836.x.&lt;br /&gt;
* &lt;br /&gt;
* Gore, C. J., Rodríguez, F. A., Truijens, M. J., Townsend, N. E., Stray-Gundersen, J. &amp;amp; Levine, B. D. (2006): Increased serum erythropoietin but not red cell production after 4 wk of intermittent hypobaric hypoxia (4,000-5,500 m). Journal of applied physiology (Bethesda, Md. : 1985), 101 (5), 1386-1393. doi: 10.1152/japplphysiol.00342.2006.&lt;br /&gt;
* &lt;br /&gt;
* Gore, C. J., Clark, S. A. &amp;amp; Saunders, P. U. (2007): Nonhematological mechanisms of improved sea-level performance after hypoxic exposure. Medicine and science in sports and exercise, 39 (9), 1600-1609. doi: 10.1249/mss.0b013e3180de49d3.&lt;br /&gt;
* &lt;br /&gt;
* Gough, C. E., Sharpe, K., Garvican, L. A., Anson, J. M., Saunders, P. U. &amp;amp; Gore, C. J. (2013): The effects of injury and illness on haemoglobin mass. International journal of sports medicine, 34 (9), 763-769. doi: 10.1055/s-0033-1333692.&lt;br /&gt;
* &lt;br /&gt;
* Gough, C. E., Saunders, P. U., Fowlie, J., Savage, B., Pyne, D. B., Anson, J. M. et al. (2012): Influence of altitude training modality on performance and total haemoglobin mass in elite swimmers. European journal of applied physiology, 112 (9), 3275-3285. doi: 10.1007/s00421-011-2291-7.&lt;br /&gt;
* &lt;br /&gt;
* Groslambert, A., Grappe, F., Bertucci, W., Perrey, S., Girard, A. J. &amp;amp; Rouillon, J. D. (2004): A perceptive individual time trial performed by triathletes to estimate the anaerobic threshold. A preliminary study. The Journal of sports medicine and physical fitness, 44 (2), 147-156.&lt;br /&gt;
* &lt;br /&gt;
* Haakonssen, E. C., Martin, D. T., Burke, L. M. &amp;amp; Jenkins, D. G. (2013): Energy expenditure of constant- and variable-intensity cycling: power meter estimates. Medicine and science in sports and exercise, 45 (9), 1833-1840. doi: 10.1249/MSS.0b013e31828e18e6.&lt;br /&gt;
* &lt;br /&gt;
* Hahn, A. G. &amp;amp; Gore, C. J. (2001): The effect of altitude on cycling performance: a challenge to traditional concepts. Sports medicine (Auckland, N.Z.), 31 (7), 533-557.&lt;br /&gt;
* &lt;br /&gt;
* Hahn, A. G., Gore, C. J., Martin, D. T., Ashenden, M. J., Roberts, A. D. &amp;amp; Logan, P. A. (2001): An evaluation of the concept of living at moderate altitude and training at sea level. Comparative biochemistry and physiology. Part A, Molecular &amp;amp; integrative physiology, 128 (4), 777-789.&lt;br /&gt;
* &lt;br /&gt;
* Hajoglou, A., Foster, C., Koning, J. J. de, Lucia, A., Kernozek, T. W. &amp;amp; Porcari, J. P. (2005): Effect of warm-up on cycle time trial performance. Medicine and science in sports and exercise, 37 (9), 1608-1614.&lt;br /&gt;
* &lt;br /&gt;
* Hopker, J., Myers, S., Jobson, S. A., Bruce, W. &amp;amp; Passfield, L. (2010): Validity and reliability of the Wattbike cycle ergometer. International journal of sports medicine, 31 (10), 731-736. doi: 10.1055/s-0030-1261968.&lt;br /&gt;
* &lt;br /&gt;
* Hurst, H. T. &amp;amp; Atkins, S. (2006): Agreement between polar and SRM mobile ergometer systems during laboratory-based high-intensity, intermittent cycling activity. Journal of sports sciences, 24 (8), 863-868. doi: 10.1080/02640410500245678.&lt;br /&gt;
* &lt;br /&gt;
* Hurst, H. T. &amp;amp; Atkins, S. (2006): Power output of field-based downhill mountain biking. Journal of sports sciences, 24 (10), 1047-1053. doi: 10.1080/02640410500431997.&lt;br /&gt;
* &lt;br /&gt;
* Jobson, S., Woodside, J., Passfield, L. &amp;amp; Nevill, A. (2008): Allometric Scaling of Uphill Cycling Performance. International journal of sports medicine, 29 (09), 753-757. doi: 10.1055/s-2007-989441.&lt;br /&gt;
* &lt;br /&gt;
* Jobson, S. A., Passfield, L., Atkinson, G., Barton, G. &amp;amp; Scarf, P. (2009): The analysis and utilization of cycling training data. Sports medicine (Auckland, N.Z.), 39 (10), 833-844. doi: 10.2165/11317840-000000000-00000.&lt;br /&gt;
* &lt;br /&gt;
* Julian, C. G., Gore, C. J., Wilber, R. L., Daniels, J. T., Fredericson, M., Stray-Gundersen, J. et al. (2004): Intermittent normobaric hypoxia does not alter performance or erythropoietic markers in highly trained distance runners. Journal of applied physiology (Bethesda, Md. : 1985), 96 (5), 1800-1807. doi: 10.1152/japplphysiol.00969.2003.&lt;br /&gt;
* &lt;br /&gt;
* Karsten, B., Jobson, S. A., Hopker, J., Jimenez, A. &amp;amp; Beedie, C. (2014): High Agreement between Laboratory and Field Estimates of Critical Power in Cycling. International journal of sports medicine, 35 (4), 298-303. doi: 10.1055/s-0033-1349844.&lt;br /&gt;
* &lt;br /&gt;
* Karsten, B., Jobson, S. A., Hopker, J., Passfield, L. &amp;amp; Beedie, C. (2013): The 3-min Test Does not Provide a Valid Measure of Critical Power Using the SRM Isokinetic Mode. International journal of sports medicine. doi: 10.1055/s-0033-1349093.&lt;br /&gt;
* &lt;br /&gt;
* Kinsman, T. A., Gore, C. J., Hahn, A. G., Hopkins, W. G., Hawley, J. A., McKenna, M. J. et al. (2005): Sleep in athletes undertaking protocols of exposure to nocturnal simulated altitude at 2650 m. Journal of science and medicine in sport / Sports Medicine Australia, 8 (2), 222-232.&lt;br /&gt;
* &lt;br /&gt;
* Kinsman, T. A., Hahn, A. G., Gore, C. J., Martin, D. T. &amp;amp; Chow, C. M. (2003): Sleep quality responses to atmospheric variation: case studies of two elite female cyclists. Journal of science and medicine in sport / Sports Medicine Australia, 6 (4), 436-442.&lt;br /&gt;
* &lt;br /&gt;
* Kinsman, T. A., Hahn, A. G., Gore, C. J., Wilsmore, B. R., Martin, D. T. &amp;amp; Chow, C.-M. (2002): Respiratory events and periodic breathing in cyclists sleeping at 2,650-m simulated altitude. Journal of applied physiology (Bethesda, Md. : 1985), 92 (5), 2114-2118. doi: 10.1152/japplphysiol.00737.2001.&lt;br /&gt;
* &lt;br /&gt;
* Kinsman, T. A., Townsend, N. E., Gore, C. J., Hahn, A. G., Clark, S. A., Aughey, R. J. et al. (2005): Sleep disturbance at simulated altitude indicated by stratified respiratory disturbance index but not hypoxic ventilatory response. European journal of applied physiology, 94 (5-6), 569-575. doi: 10.1007/s00421-005-1368-6.&lt;br /&gt;
* &lt;br /&gt;
* Kirkland, A., Coleman, D., Wiles, J. D. &amp;amp; Hopker, J. (2008): Validity and reliability of the Ergomopro powermeter. International journal of sports medicine, 29 (11), 913-916. doi: 10.1055/s-2008-1038621.&lt;br /&gt;
* &lt;br /&gt;
* Loughlin, A. F., Skiles, G. L., Alberts, D. W. &amp;amp; Schaefer, W. H. (2001): An ion exchange liquid chromatography/mass spectrometry method for the determination of reduced and oxidized glutathione and glutathione conjugates in hepatocytes. Journal of pharmaceutical and biomedical analysis, 26 (1), 131-142.&lt;br /&gt;
* &lt;br /&gt;
* MacIntosh, B. R., Svedahl, K. &amp;amp; Kim, M. (2004): Fatigue and optimal conditions for short-term work capacity. European journal of applied physiology, 92 (4-5), 369-375. doi: 10.1007/s00421-004-1177-3.&lt;br /&gt;
* &lt;br /&gt;
* MacRae HS-H, Hise, K. J. &amp;amp; Allen, P. J. (2000): Effects of front and dual suspension mountain bike systems on uphill cycling performance. Medicine and science in sports and exercise, 32 (7), 1276-1280.&lt;br /&gt;
* &lt;br /&gt;
* Maier, T., Steiner, T., Trösch, S., Müller, B. &amp;amp; Wehrlin, J. P. (2014): Reliability of power meter calibration by mathematical modelling of treadmill cycling. J Sci Cycling (Vol. 3(2), 28).&lt;br /&gt;
* &lt;br /&gt;
* Mc Naughton, L. R., Sherman, R., Roberts, S. &amp;amp; Bentley, D. J. (2005): Portable gas analyser Cosmed K4b2 compared to a laboratory based mass spectrometer system. The Journal of sports medicine and physical fitness, 45 (3), 315-323.&lt;br /&gt;
* &lt;br /&gt;
* McDaniel, J., Subudhi, A. &amp;amp; Martin, J. C. (2005): Torso stabilization reduces the metabolic cost of producing cycling power. Canadian journal of applied physiology = Revue canadienne de physiologie appliquée, 30 (4), 433-441.&lt;br /&gt;
* &lt;br /&gt;
* McLean, B. D., Buttifant, D., Gore, C. J., White, K., Liess, C. &amp;amp; Kemp, J. (2013): Physiological and performance responses to a preseason altitude-training camp in elite team-sport athletes. International journal of sports physiology and performance, 8 (4), 391-399.&lt;br /&gt;
* &lt;br /&gt;
* Menaspa, P., Quod, M., Martin, D. T., Peiffer, J. J. &amp;amp; Abbiss, C. R. (2015): Physical Demands of Sprinting in Professional Road Cycling. International journal of sports medicine, 36 (13), 1058-1062. doi: 10.1055/s-0035-1554697.&lt;br /&gt;
* &lt;br /&gt;
* Meyer, T., Gabriel, H. H. W., Auracher, M., Scharhag, J. &amp;amp; Kindermann, W. (2003): Metabolic profile of 4 h cycling in the field with varying amounts of carbohydrate supply. European journal of applied physiology, 88 (4-5), 431-437. doi: 10.1007/s00421-002-0712-3.&lt;br /&gt;
* &lt;br /&gt;
* Mijnarends, D. M., Meijers, J. M. M., Halfens, R. J. G., Ter Borg, S., Luiking, Y. C., Verlaan, S. et al. (2013): Validity and reliability of tools to measure muscle mass, strength, and physical performance in community-dwelling older people: a systematic review. Journal of the American Medical Directors Association, 14 (3), 170-178. doi: 10.1016/j.jamda.2012.10.009.&lt;br /&gt;
* &lt;br /&gt;
* Millet, G. P., Tronche, C., Fuster, N., Bentley, D. J. &amp;amp; Candau, R. (2003): Validity and reliability of the Polar S710 mobile cycling powermeter. International journal of sports medicine, 24 (3), 156-161. doi: 10.1055/s-2003-39083.&lt;br /&gt;
* &lt;br /&gt;
* Millet, G. P., Tronche, C., Fuster, N. &amp;amp; Candau, R. (2002): Level ground and uphill cycling efficiency in seated and standing positions. Medicine and science in sports and exercise, 34 (10), 1645-1652. doi: 10.1249/01.MSS.0000031482.14781.D7.&lt;br /&gt;
* &lt;br /&gt;
* Mornieux, G., Gollhofer, A. &amp;amp; Stapelfeldt, B. (2010): Muscle Coordination while Pulling up During Cycling. International journal of sports medicine, 31 (12), 843-846. doi: 10.1055/s-0030-1263140.&lt;br /&gt;
* &lt;br /&gt;
* Mornieux, G., Stapelfeldt, B., Gollhofer, A. &amp;amp; Belli, A. (2008): Effects of Pedal Type and Pull-Up Action during Cycling: International journal of sports medicine, 29 (10), 817-822. doi: 10.1055/s-2008-1038374.&lt;br /&gt;
* &lt;br /&gt;
* Neville, V., Zaher, N., Pain, M. T. G. &amp;amp; Folland, J. P. (2009): Lower limb influence on standing arm-cranking ('grinding'). International journal of sports medicine, 30 (10), 713-718. doi: 10.1055/s-0029-1231044.&lt;br /&gt;
* &lt;br /&gt;
* Neville, V., Pain, M. T. G. &amp;amp; Folland, J. P. (2009): Aerobic power and peak power of elite America's Cup sailors. European journal of applied physiology, 106 (1), 149-157. doi: 10.1007/s00421-009-1002-0.&lt;br /&gt;
* &lt;br /&gt;
* Neville, V., Pain, M. T. G., Kantor, J. &amp;amp; Folland, J. P. (2010): Influence of crank length and crank-axle height on standing arm-crank (grinding) power. Medicine and science in sports and exercise, 42 (2), 381-387. doi: 10.1249/MSS.0b013e3181b46f3a.&lt;br /&gt;
* &lt;br /&gt;
* Neya, M., Enoki, T., Ohiwa, N., Kawahara, T. &amp;amp; Gore, C. J. (2013) Increased hemoglobin mass and VO2max with 10 h nightly simulated altitude at 3000 m. International journal of sports physiology and performance, 8 (4), 366-372.&lt;br /&gt;
* &lt;br /&gt;
* Nimmerichter, A., Williams, C., Bachl, N. &amp;amp; Eston, R. (2010): Evaluation of a field test to assess performance in elite cyclists. International journal of sports medicine, 31 (3), 160-166. doi: 10.1055/s-0029-1243222.&lt;br /&gt;
* &lt;br /&gt;
* Nimmerichter, A., Eston, R. G., Bachl, N. &amp;amp; Williams, C. (2011): Longitudinal monitoring of power output and heart rate profiles in elite cyclists. Journal of sports sciences, 29 (8), 831-840. doi: 10.1080/02640414.2011.561869.&lt;br /&gt;
* &lt;br /&gt;
* Nimmerichter, A. &amp;amp; Williams, C. A. (2015): Comparison of power output during ergometer and track cycling in adolescent cyclists. Journal of strength and conditioning research / National Strength &amp;amp; Conditioning Association, 29 (4), 1049-1056. doi: 10.1519/JSC.0000000000000723.&lt;br /&gt;
* &lt;br /&gt;
* O’Hara, J., Thomas, A., Seims, A., Cooke, C. &amp;amp; King, R. (2012): Reliability of a High-Intensity Endurance Cycling Test. International journal of sports medicine, 33 (01), 18-25. doi: 10.1055/s-0031-1284340.&lt;br /&gt;
* &lt;br /&gt;
* Parisotto, R., Gore, C. J., Hahn, A. G., Ashenden, M. J., Olds, T. S., Martin, D. T. et al. (2000): Reticulocyte parameters as potential discriminators of recombinant human erythropoietin abuse in elite athletes. International journal of sports medicine, 21 (7), 471-479. doi: 10.1055/s-2000-7421.&lt;br /&gt;
* &lt;br /&gt;
* Paton, C. D. &amp;amp; Hopkins, W. G. (2001): Tests of cycling performance. Sports medicine (Auckland, N.Z.), 31 (7), 489-496.&lt;br /&gt;
* &lt;br /&gt;
* Paton, C. D. &amp;amp; Hopkins, W. G. (2006): Ergometer error and biological variation in power output in a performance test with three cycle ergometers. International journal of sports medicine, 27 (6), 444-447. doi: 10.1055/s-2005-865781.&lt;br /&gt;
* &lt;br /&gt;
* Périard, J. D., Caillaud, C. &amp;amp; Thompson, M. W. (2011): Central and peripheral fatigue during passive and exercise-induced hyperthermia. Medicine and science in sports and exercise, 43 (9), 1657-1665. doi: 10.1249/MSS.0b013e3182148a9a.&lt;br /&gt;
* &lt;br /&gt;
* Périard, J. D., Caillaud, C. &amp;amp; Thompson, M. W. (2012): The role of aerobic fitness and exercise intensity on endurance performance in uncompensable heat stress conditions. European journal of applied physiology, 112 (6), 1989-1999. doi: 10.1007/s00421-011-2165-z.&lt;br /&gt;
* &lt;br /&gt;
* Périard, J. D., Cramer, M. N., Chapman, P. G., Caillaud, C. &amp;amp; Thompson, M. W. (2011): Cardiovascular strain impairs prolonged self-paced exercise in the heat. Experimental physiology, 96 (2), 134-144. doi: 10.1113/expphysiol.2010.054213.&lt;br /&gt;
* &lt;br /&gt;
* Périard, J. D., Cramer, M. N., Chapman, P. G., Caillaud, C. &amp;amp; Thompson, M. W. (2011): Neuromuscular function following prolonged intense self-paced exercise in hot climatic conditions. European journal of applied physiology, 111 (8), 1561-1569. doi: 10.1007/s00421-010-1781-3.&lt;br /&gt;
* &lt;br /&gt;
* Perrey, S., Grappe, F., Girard, A., Bringard, A., Groslambert, A., Bertucci, W. et al. (2003): Physiological and metabolic responses of triathletes to a simulated 30-min time-trial in cycling at self-selected intensity. International journal of sports medicine, 24 (2), 138-143. doi: 10.1055/s-2003-38200.&lt;br /&gt;
* &lt;br /&gt;
* Pinot, J. &amp;amp; Grappe, F. (2011): The record power profile to assess performance in elite cyclists. International journal of sports medicine, 32 (11), 839-844. doi: 10.1055/s-0031-1279773.&lt;br /&gt;
* &lt;br /&gt;
* Pottgiesser, T., Garvican, L. A., Martin, D. T., Featonby, J. M., Gore, C. J. &amp;amp; Schumacher, Y. O. (2012): Short-term hematological effects upon completion of a four-week simulated altitude camp. International journal of sports physiology and performance, 7 (1), 79-83.&lt;br /&gt;
* &lt;br /&gt;
* Quod, M. J., Martin, D. T., Martin, J. C. &amp;amp; Laursen, P. B. (2010): The Power Profile Predicts Road Cycling MMP. International journal of sports medicine, 31 (06), 397-401. doi: 10.1055/s-0030-1247528.&lt;br /&gt;
* &lt;br /&gt;
* Reiser, M., Meyer, T., Kindermann, W. &amp;amp; Daugs, R. (2000): Transferability of workload measurements between three different types of ergometer. European journal of applied physiology, 82 (3), 245-249. doi: 10.1007/s004210050678.&lt;br /&gt;
* &lt;br /&gt;
* Reiser, R. &amp;amp; Hart, C. (2008): Cycling on Rollers: Kreitler Fan Resistance at Submaximal Levels of Effort. International journal of sports medicine, 29 (3), 212-216. doi: 10.1055/s-2007-965002.&lt;br /&gt;
* &lt;br /&gt;
* Richalet, J.-P. &amp;amp; Gore, C. J. (2008): Live and/or sleep high:train low, using normobaric hypoxia. Scandinavian journal of medicine &amp;amp; science in sports, 18 Suppl 1, 29-37. doi: 10.1111/j.1600-0838.2008.00830.x.&lt;br /&gt;
* &lt;br /&gt;
* Roberts, A. D., Clark, S. A., Townsend, N. E., Anderson, M. E., Gore, C. J. &amp;amp; Hahn, A. G. (2003): Changes in performance, maximal oxygen uptake and maximal accumulated oxygen deficit after 5, 10 and 15 days of live high:train low altitude exposure. European journal of applied physiology, 88 (4-5), 390-395. doi: 10.1007/s00421-002-0720-3.&lt;br /&gt;
* &lt;br /&gt;
* Robertson, E. Y., Saunders, P. U., Pyne, D. B., Aughey, R. J., Anson, J. M. &amp;amp; Gore, C. J. (2010): Reproducibility of performance changes to simulated live high/train low altitude. Medicine and science in sports and exercise, 42 (2), 394-401. doi: 10.1249/MSS.0b013e3181b34b57.&lt;br /&gt;
* &lt;br /&gt;
* Robertson, E. Y., Saunders, P. U., Pyne, D. B., Gore, C. J. &amp;amp; Anson, J. M. (2010): Effectiveness of intermittent training in hypoxia combined with live high/train low. European journal of applied physiology, 110 (2), 379-387. doi: 10.1007/s00421-010-1516-5.&lt;br /&gt;
* &lt;br /&gt;
* Rodríguez, F. A., Truijens, M. J., Townsend, N. E., Stray-Gundersen, J., Gore, C. J. &amp;amp; Levine, B. D. (2007): Performance of runners and swimmers after four weeks of intermittent hypobaric hypoxic exposure plus sea level training. Journal of applied physiology (Bethesda, Md. : 1985), 103 (5), 1523-1535. doi: 10.1152/japplphysiol.01320.2006.&lt;br /&gt;
* &lt;br /&gt;
* Rylands, L. P., Roberts, S. J. &amp;amp; Hurst, H. T. (2015): Variability in Laboratory vs. Field Testing of Peak Power, Torque, and Time of Peak Power Production Among Elite Bicycle Motocross Cyclists. Journal of strength and conditioning research / National Strength &amp;amp; Conditioning Association, 29 (9), 2635-2640. doi: 10.1519/JSC.0000000000000884.&lt;br /&gt;
* &lt;br /&gt;
* Sassi, A., Rampinini, E., Martin, D. T. &amp;amp; Morelli, A. (2009): Effects of gradient and speed on freely chosen cadence: the key role of crank inertial load. Journal of biomechanics, 42 (2), 171-177. doi: 10.1016/j.jbiomech.2008.10.008.&lt;br /&gt;
* &lt;br /&gt;
* Saunders, P. U., Telford, R. D., Pyne, D. B., Cunningham, R. B., Gore, C. J., Hahn, A. G. et al. (2004): Improved running economy in elite runners after 20 days of simulated moderate-altitude exposure. Journal of applied physiology (Bethesda, Md. : 1985), 96 (3), 931-937. doi: 10.1152/japplphysiol.00725.2003.&lt;br /&gt;
* &lt;br /&gt;
* Saunders, P. U., Telford, R. D., Pyne, D. B., Hahn, A. G. &amp;amp; Gore, C. J. (2009): Improved running economy and increased hemoglobin mass in elite runners after extended moderate altitude exposure. Journal of science and medicine in sport / Sports Medicine Australia, 12 (1), 67-72. doi: 10.1016/j.jsams.2007.08.014.&lt;br /&gt;
* &lt;br /&gt;
* Saunders, P. U., Ahlgrim, C., Vallance, B., Green, D. J., Robertson, E. Y., Clark, S. A. et al. (2010): An attempt to quantify the placebo effect from a three-week simulated altitude training camp in elite race walkers. International journal of sports physiology and performance, 5 (4), 521-534.&lt;br /&gt;
* &lt;br /&gt;
* Saunders, P. U., Pyne, D. B. &amp;amp; Gore, C. J. (2009): Endurance training at altitude. High altitude medicine &amp;amp; biology, 10 (2), 135-148. doi: 10.1089/ham.2008.1092.&lt;br /&gt;
* &lt;br /&gt;
* Saunders, P. U., Telford, R. D., Pyne, D. D., Gore, C. J. &amp;amp; Hahn, A. G. (2009): Improved race performance in elite middle-distance runners after cumulative altitude exposure. International journal of sports physiology and performance, 4 (1), 134-138.&lt;br /&gt;
* &lt;br /&gt;
* Sharpe, K., Hopkins, W., Emslie, K. R., Howe, C., Trout, G. J., Kazlauskas, R. et al. (2002): Development of reference ranges in elite athletes for markers of altered erythropoiesis. Haematologica, 87 (12), 1248-1257.&lt;br /&gt;
* &lt;br /&gt;
* Simons, M., van Es, E. &amp;amp; Hendriksen, I. (2009): Electrically assisted cycling: a new mode for meeting physical activity guidelines? Medicine and science in sports and exercise, 41 (11), 2097-2102. doi: 10.1249/MSS.0b013e3181a6aaa4.&lt;br /&gt;
* &lt;br /&gt;
* Smith, M. F., Davison, R. C., Balmer, J. &amp;amp; Bird, S. R. (2001): Reliability of mean power recorded during indoor and outdoor self-paced 40 km cycling time-trials. International journal of sports medicine, 22 (4), 270-274. doi: 10.1055/s-2001-13813.&lt;br /&gt;
* &lt;br /&gt;
* Sparks, S. A., Dove, B., Bridge, C. A., Midgely, A. W. &amp;amp; McNaughton, L. R. (2014): Validity and Reliability of the Look Keo Power Pedal System for Measuring Power Output During Incremental and Repeated Sprint Cycling. International journal of sports physiology and performance. doi: 10.1123/ijspp.2013-0317.&lt;br /&gt;
* &lt;br /&gt;
* Stapelfeldt, B., Mornieux, G., Oberheim, R., Belli, A. &amp;amp; Gollhofer, A. (2007): Development and evaluation of a new bicycle instrument for measurements of pedal forces and power output in cycling. International journal of sports medicine, 28 (4), 326-332. doi: 10.1055/s-2006-924352.&lt;br /&gt;
* &lt;br /&gt;
* Stapelfeldt, B., Schwirtz, A., Schumacher, Y. O. &amp;amp; Hillebrecht, M. (2004): Workload demands in mountain bike racing. International journal of sports medicine, 25 (4), 294-300. doi: 10.1055/s-2004-819937.&lt;br /&gt;
* &lt;br /&gt;
* Tomas, A., Ross, E. Z. &amp;amp; Martin, J. C. (2010): Fatigue during maximal sprint cycling: unique role of cumulative contraction cycles. Medicine and science in sports and exercise, 42 (7), 1364-1369. doi: 10.1249/MSS.0b013e3181cae2ce.&lt;br /&gt;
* &lt;br /&gt;
* Townsend, N. E., Gore, C. J., Ebert, T. R., Martin, D. T., Hahn, A. G. &amp;amp; Chow, C.-M. (2016): Ventilatory acclimatisation is beneficial for high-intensity exercise at altitude in elite cyclists. European journal of sport science, 1-8. doi: 10.1080/17461391.2016.1139190.&lt;br /&gt;
* &lt;br /&gt;
* Townsend, N. E., Gore, C. J., Hahn, A. G., Aughey, R. J., Clark, S. A., Kinsman, T. A. et al. (2005): Hypoxic ventilatory response is correlated with increased submaximal exercise ventilation after live high, train low. European journal of applied physiology, 94 (1-2), 207-215. doi: 10.1007/s00421-004-1252-9.&lt;br /&gt;
* &lt;br /&gt;
* Townsend, N. E., Gore, C. J., Hahn, A. G., McKenna, M. J., Aughey, R. J., Clark, S. A. et al. (2002): Living high-training low increases hypoxic ventilatory response of well-trained endurance athletes. Journal of applied physiology (Bethesda, Md. : 1985), 93 (4), 1498-1505. doi: 10.1152/japplphysiol.00381.2002.&lt;br /&gt;
* &lt;br /&gt;
* Truijens, M. J., Rodríguez, F. A., Townsend, N. E., Stray-Gundersen, J., Gore, C. J. &amp;amp; Levine, B. D. (2008). The effect of intermittent hypobaric hypoxic exposure and sea level training on submaximal economy in well-trained swimmers and runners. Journal of applied physiology (Bethesda, Md. : 1985), 104 (2), 328-337. doi: 10.1152/japplphysiol.01324.2006.&lt;br /&gt;
* &lt;br /&gt;
* Vaile, J., Halson, S., Gill, N. &amp;amp; Dawson, B. (2008): Effect of Hydrotherapy on Recovery from Fatigue. International journal of sports medicine, 29 (7), 539-544. doi: 10.1055/s-2007-989267.&lt;br /&gt;
* &lt;br /&gt;
* van der Woude, L. H. V., Horstman, A., Faas, P., Mechielsen, S., Bafghi, H. A. &amp;amp; Koning, J. J. de. (2008): Power output and metabolic cost of synchronous and asynchronous submaximal and peak level hand cycling on a motor driven treadmill in able-bodied male subjects. Medical engineering &amp;amp; physics, 30 (5), 574-580. doi: 10.1016/j.medengphy.2007.06.006.&lt;br /&gt;
* &lt;br /&gt;
* Villerius, V., Duc, S. &amp;amp; Grappe, F. (2008): Physiological and Neuromuscular Responses of Competitive Cyclists during a Simulated Self-Paced Interval Training Session. International journal of sports medicine, 29 (09), 770-777. doi: 10.1055/s-2007-989317.&lt;br /&gt;
* &lt;br /&gt;
* Vogt, S., Roecker, K., Schumacher, Y. O., Pottgiesser, T., Dickhuth, H.-H., Schmid, A. et al. (2008): Cadence-power-relationship during decisive mountain ascents at the Tour de France. International journal of sports medicine, 29 (3), 244-250. doi: 10.1055/s-2007-965353.&lt;br /&gt;
* &lt;br /&gt;
* Vogt, S., Schumacher, Y. O., Roecker, K., Dickhuth, H.-H., Schoberer, U., Schmid, A. et al. (2007). Power Output during the Tour de France. International journal of sports medicine, 28 (9), 756-761. doi: 10.1055/s-2007-964982.&lt;br /&gt;
* &lt;br /&gt;
* Vogt, S., Heinrich, L., Schumacher, Y. O., Blum, A., Roecker, K., Dickhuth, H.-H. et al. (2006): Power output during stage racing in professional road cycling. Medicine and science in sports and exercise, 38 (1), 147-151.&lt;br /&gt;
* &lt;br /&gt;
* Vogt, S., Schumacher, Y. O., Blum, A., Roecker, K., Dickhuth, H.-H., Schmid, A. et al. (2007): Cycling power output produced during flat and mountain stages in the Giro d'Italia: a case study. Journal of sports sciences, 25 (12), 1299-1305. doi: 10.1080/02640410601001632.&lt;br /&gt;
* &lt;br /&gt;
* Wahl, P., Mathes, S., Köhler, K., Achtzehn, S., Bloch, W. &amp;amp; Mester, J. (2013): Acute Metabolic, Hormonal, and Psychological Responses to Different Endurance Training Protocols. Hormone and Metabolic Research, 45 (11), 827-833. doi: 10.1055/s-0033-1347242.&lt;br /&gt;
* &lt;br /&gt;
* Wahl, P., Schmidt, A., deMarees, M., Achtzehn, S., Bloch, W. &amp;amp; Mester, J. (2013): Responses of Angiogenic Growth Factors to Exercise, to Hypoxia and to Exercise under Hypoxic Conditions. International journal of sports medicine, 34 (02), 95-100. doi: 10.1055/s-0032-1314815.&lt;br /&gt;
* &lt;br /&gt;
* Wiedemann, M. S. F. &amp;amp; Bosquet, L. (2010): Anaerobic Work Capacity Derived from Isokinetic and Isoinertial Cycling. International journal of sports medicine, 31 (02), 89-94. doi: 10.1055/s-0029-1233466.&lt;br /&gt;
* &lt;br /&gt;
* Wilson, M. G., Lane, A. M., Beedie, C. J. &amp;amp; Farooq, A. (2012): Influence of accurate and inaccurate 'split-time' feedback upon 10-mile time trial cycling performance. European journal of applied physiology, 112 (1), 231-236. doi: 10.1007/s00421-011-1977-1.&lt;br /&gt;
* &lt;br /&gt;
* Wu, S. S. X., Peiffer, J. J., Brisswalter, J., Nosaka, K., Lau, W. Y. &amp;amp; Abbiss, C. R. (2015): Pacing strategies during the swim, cycle and run disciplines of sprint, Olympic and half-Ironman triathlons. European journal of applied physiology, 115 (5), 1147-1154. doi: 10.1007/s00421-014-3096-2.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
(In der folgenden Tabelle finden Sie aktuelle internationale Literaturstellen in denen das SRM - Ergometer und / oder die SRM - Trainingssysteme für wissenschaftliche Untersuchungen eingesetzt wurden.&lt;br /&gt;
[[Media:Scientific Publications SRM 2013.pdf|Hier]] finden sie die internationalen Literaturstellen in einem pfd - Dokument zusammengefasst.)&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot;&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|- class=&amp;quot;hintergrundfarbe6&amp;quot;&lt;br /&gt;
!style=&amp;quot;width:30%&amp;quot;| Autor!! style=&amp;quot;width:30%&amp;quot; | Titel!! style=&amp;quot;width:30%&amp;quot; | Publikation&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Abbiss, C.R.; Quod, M.J.; Martin, David T.; Netto, K.J.; Nosaka, K.; Lee, H. et al. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Dynamic pacing strategies during the cycle phase of an Ironman triathlon.  &lt;br /&gt;
|style=&amp;quot;vertical-align:top&amp;quot;| Med Sci Sports Exerc 38 (4), S. 726–734&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Abbiss, C.R.; Quod, M.J.; Levin, G.; Martin, D.T.; Laursen, P.B. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Accuracy of the Velotron ergometer and SRM power meter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 30 (2), S. 107–112.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Abel, T.; Burkett, B.; Schneider, S.; Lindschulten, R.; Strüder, H. K. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The exercise profile of an ultra-long handcycling race: the Styrkeprøven experience.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Spinal Cord 48 (12), S. 894–898.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Antonutto, G.; Capelli, C.; Girardis, M.; Zamparo, P.; di Prampero P.E. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of microgravity on maximal power of lower limbs during very short efforts in humans.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Physiol 86(1), S. 85-92.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Arkesteijn, M.; Hopker, J.; Jobson, S.; Passfield, L. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The Effect of Turbo Trainer Cycling on Pedalling Technique and Cycling Efficiency.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 34 (06), S. 520–525&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M. J.; Gore, C. J.; Burge, C. M.; Clough, M. L.; Bourdon, P. C.; Dobson, G. P.; Hahn, A. G. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Skin-prick blood samples are reliable for estimating Hb mass with the CO-dilution technique.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 79 (6), S. 535–537.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M. J.; Gore, C. J.; Dobson, G. P.; Boston, T. T.; Parisotto, R.; Emslie, K. R. et al. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Simulated moderate altitude elevates serum erythropoietin but does not increase reticulocyte production in well-trained runners.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 81 (5), S. 428–435&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Gore, C. J.; Dobson, G. P.; Hahn, A. G. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| &amp;quot;Live high, train low&amp;quot; does not change the total haemoglobin mass of male endurance athletes sleeping at a simulated altitude of 3000 m for 23 nights. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 80 (5), S. 479–484.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Gore, C. J.; Martin, D. T.; Dobson, G. P.; Hahn, A. G. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of a 12-day &amp;quot;live high, train low&amp;quot; camp on reticulocyte production and haemoglobin mass in elite female road cyclists.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 80 (5), S. 472–478.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Hahn, A. G.; Martin, D. T.; Logan, P.; Parisotto, R.; Gore, C. J. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| A comparison of the physiological response to simulated altitude exposure and r-HuEpo administration.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 19 (11), S. 831–837&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Gore, C.J.; Parisotto, R.; Sharpe, K.; Hopkins, W.G.; Hahn, A.G. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effect of altitude on second-generation blood tests to detect erythropoietin abuse by athletes.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Haematologica 88 (9), S. 1053–1062&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Aughey, R. J.; Clark, S. A.; Gore, C. J.; Townsend, N. E.; Hahn, A. G.; Kinsman, T. A. et al. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Interspersed normoxia during live high, train low interventions reverses an early reduction in muscle Na+, K +ATPase activity in well-trained athletes.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 98 (3), S. 299–309&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Aughey, R. J.; Gore, C. J.; Hahn, A. G.; Garnham, A. P.; Clark, S. A.; Petersen, A. C. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Chronic intermittent hypoxia and incremental cycling exercise independently depress muscle in vitro maximal Na+-K+-ATPase activity in well-trained athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 98 (1), S. 186–192&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashman, S.B.; Monk, T.H.; Kupfer, D.J.; Clark, C.H.; Myers, F.S.; Frank, E.; Leibenluft (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Relationship between social rhythms and mood in patients with rapid cycling bipolar disorder.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Psychiatry Res 86 (1), S. 1–8&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Austin, N.; Nilwik, R.; Herzog, W. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| In vivo operational fascicle lengths of vastus lateralis during submaximal and maximal cycling.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Biomech 43 (12), S. 2394–2399&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Balmer, J.; Bird, S.; Davison, R.C.R.; Doherty, M.; Smith, P. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Mechanically braked Wingate powers: agreement between SRM, corrected and conventional methods of measurement.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 22 (7), S. 661–667&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Bird, S.; Davison, R.; Lucia, A. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effect of age on 16.1-km time-trial performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 26 (2), S. 197–206&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Davison, R.C.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Peak power predicts performance power during an outdoor 16.1-km cycling time trial.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 32 (8), S. 1485–1490&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Balmer, J.; Davison, R.C.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reliability of an air-braked ergometer to record peak power during a maximal cycling test.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 32 (10), S. 1790–1793&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Davison, R.C.; Coleman, D.A.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The validity of power output recorded during exercise performance tests using a Kingcycle air-braked cycle ergometer when compared with an SRM powermeter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 21 (3), S. 195–199&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bassett, D.R.; Kyle, C. R.; Passfield, L.; Broker, J.P.; Burke, E.R. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Comparing cycling world hour records, 1967-1996: modeling with empirical data.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 31 (11), S. 1665–1676&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bentley, D. J.; McNaughton, L. R.; Thompson, D.; Vleck, V. E.; Batterham, A. M. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Peak power output, the lactate threshold, and time trial performance in cyclists. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 33 (12), S. 2077–2081&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Crequy, S.; Chiementin, X. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and Reliability of the G-Cog BMX Powermeter.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Bertucci, W.; Duc, S.; Villerius, V.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of the Axiom PowerTrain cycle ergometer when compared with an SRM powermeter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (1), S. 59–65&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Duc, S.; Villerius, V.; Pernin, J. N.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and reliability of the PowerTap mobile cycling powermeter when compared with the SRM Device.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (10), S. 868–873&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Grappe, F.; Girard, A.; Betik, A.; Rouillon, J.D. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects on the crank torque profile when changing pedalling cadence in level ground and uphill road cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Biomech 38 (5), S. 1003–1010&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Grappe, F.; Groslambert, A. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Laboratory versus outdoor cycling conditions: differences in pedaling biomechanics. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Biomech 23 (2), S. 87–92&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Taiar, R.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Differences between sprint tests under laboratory and actual cycling conditions. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Med Phys Fitness 45 (3), S. 277–283&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Billaut, François; Gore, Christopher J.; Aughey, Robert J. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Enhancing team-sport athlete performance: is altitude training relevant?&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 42 (9), S. 751–767&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Brickley, G.; Dekerle, J.; Hammond, A.; Pringle, J.; Carter, H. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Assessment of Maximal Aerobic Power and Critical Power in a Single 90-s Isokinetic All-Out Cycling Test.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 28 (5), S. 414–419&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Broker, J.P.; Kyle, C.R.; Burke, E.R. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Racing cyclist power requirements in the 4000-m individual and team pursuits.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 31 (11), S. 1677–1685&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Brosnan, M. J.; Martin, D. T.; Hahn, A. G.; Gore, C. J.; Hawley, J. A. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Impaired interval exercise responses in elite female cyclists at moderate simulated altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 89 (5), S. 1819–1824&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Cangley, P.; Passfield, L.; Carter, H.; Bailey, M. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The Effect of Variable Gradients on Pacing in Cycling Time-Trials.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 32 (02), S. 132–136&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Carpes, F.P.; Rossato, M.; Faria, I.E.; Bolli Mota, C. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Bilateral pedaling asymmetry during a simulated 40-km cycling timetrial.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Med Phys Fitness 47 (1), S. 51–57&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Clark, Sally A.; Bourdon, P. C.; Schmidt, W.; Singh, B.; Cable, G.; Onus, K. J. et al. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The effect of acute simulated moderate altitude on power, performance and pacing strategies in well-trained cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 102 (1), S. 45–55&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Clark, Sally A.; Quod, M. J.; Clark, M. A.; Martin, D. T.; Saunders, P. U.; Gore, C. J. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Time course of haemoglobin mass during 21 days live high:train low simulated altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 106 (3), S. 399–406&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Clark, S.K.; Johnson, Thomas M. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Selenium stable isotope investigation into selenium biogeochemical cycling in a lacustrine environment: Sweitzer Lake, Colorado.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Environ. Qual. 39 (6), S. 2200–2210&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Coleman, D.A.; Wiles, J.D.; Nunn, M.; Smith, M.F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reliability of sprint test indices in well-trained cyclists. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (5), S. 383–387&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Doherty, M.; Balmer, J.; Davison, R.C.R.; Robinson, L.; Smith, P.M. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reliability of a combined 3-min constant load and performance cycling test.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 24 (5), S. 366–371&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Duc, S.; Betik, A-C; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| EMG activity does not change during a time trial in competitive cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (2), S. 145–150&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Duc, S.; Villerius, V.; Bertucci, W.; Pernin, J.N.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Muscular activity level during pedalling is not affected by crank inertial load.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 95 (2-3), S. 260–264&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Duc, S.; Villerius, V.; Bertucci, W.; Grappe, F. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and reproducibility of the ErgomoPro power meter compared with the SRM and Powertap power meters.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 2 (3), S. 270–281&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Eastwood, A.; Sharpe, K.; Bourdon, P.C.; Woolford, S.M.; Saunders, P.U.; Robertson, E.Y. et al. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Within-subject variation in hemoglobin mass in elite athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 44 (4), S. 725–732&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Ebert, T.R.; Martin, D.T.; McDonald, W.; Victor, J.; Plummer, J.; Withers, R.T. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Power output during women's World Cup road cycle racing.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 95 (5-6), S. 529–536&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ebert, T.R.; Martin, D.T.; Stephens, B.; Withers, R.T. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Power output during a professional men's road-cycling tour.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 1 (4), S. 324–335&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Emonson, D. L.; Aminuddin, A. H.; Wight, R. L.; Scroop, G. C.; Gore, C. J. (1997)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Training-induced increases in sea level VO2max and endurance are not enhanced by acute hypobaric exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 76 (1), S. 8–12&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Faiss, R.; Praz, M.; Meichtry, A.; Gobelet, C.; Deriaz, O. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The effect of mountain bike suspensions on vibrations and off-road uphill performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Med Phys Fitness 47 (2), S. 151–158&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Fu, Qi; Townsend, N.E.; Shiller, S.M.; Martini, E.R.; Okazaki, K.; Shibata, S. et al. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Intermittent hypobaric hypoxia exposure does not cause sustained alterations in autonomic control of blood pressure in young athletes. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Am. J. Physiol. Regul. Integr. Comp. Physiol. 292 (5), S. R1977-84&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gardner, A.S.; Martin, J.C.; Martin, D.T.; Barras, M.; Jenkins, D.G. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Maximal torque- and power-pedaling rate relationships for elite sprint cyclists in laboratory and field tests. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 101 (3), S. 287–292&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gardner, A.S.; Martin, D.T.; Jenkins, D.G.; Dyer, I.; van Eiden, J.; Barras, M.; Martinm, J.C. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Velocity-specific fatigue: quantifying fatigue during variable velocity cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Med Sci Sports Exerc 41 (4), S. 904–911&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gardner, A.S.; Stephens, S.; Martin, D.T.; Lawton, E.; Lee, H.; Jenkins, D. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Accuracy of SRM and power tap power monitoring systems for bicycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 36 (7), S. 1252–1258&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Garvican, L.A.; Hammond, K.; Varley, Matthew C.; Gore, C.J.; Billaut, F.; Aughey, R.J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Lower Running Performance and Exacerbated Fatigue in Soccer Played at 1600 m. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Garvican, L.A.; Martin, D.T.; Clark, S.A.; Schmidt, W.F.; Gore, C.J. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Variability of erythropoietin response to sleeping at simulated altitude: a cycling case study. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 2 (3), S. 327–331.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Garvican, L.A.; Pottgiesser, T.; Martin, D.T.; Schumacher, Y.O.; Barras, M.; Gore, C.J. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The contribution of haemoglobin mass to increases in cycling performance induced by simulated LHTL. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 111 (6), S. 1089–1101&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Garvican, L.A.; Saunders, P.U.; Pyne, D.B.; Martin, D.T.; Robertson, E.Y.; Gore, C.J. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Hemoglobin mass response to simulated hypoxia &amp;quot;blinded&amp;quot; by noisy measurement? &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 112 (10), S. 1797-8; author reply 1799&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Giacomoni, M.; Billaut, F.; Falgairette, G. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effects of the Time of Day on Repeated All-Out Cycle Performance and Short-Term Recovery Patterns. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 27 (6), S. 468–474&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| González-Haro, C.; Galilea B., P.A.; Soria, M.; Drobnic, F.; Escanero, J.F. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Comparison of nine theoretical models for estimating the mechanical power output in cycling. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Br J Sports Med 41 (8), S. 506-9; discussion 509&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| González-Haro, C.; Galilea, P.A.; Escanero, J.F. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Comparison of different theoretical models estimating peak power output and maximal oxygen uptake in trained and elite triathletes and endurance cyclists in the velodrome. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Sci 26 (6), S. 591–601&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Goosey-Tolfrey, V.; Castle, P.; Webborn, N.; Abel, T. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Aerobic capacity and peak power output of elite quadriplegic games players.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Br J Sports Med 40 (8), S. 684–687&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gordon, R.S.; Franklin, K.L.; Davies, B.; Baker, J.S. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Further mechanical considerations between polar and SRM mobile ergometer systems during laboratory-based high-intensity, intermittent cycling activity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Res Sports Med 15 (4), S. 241–247&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, Christopher John; Clark, Sally A.; Saunders, Philo U. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Nonhematological mechanisms of improved sea-level performance after hypoxic exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 39 (9), S. 1600–1609&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A. G.; Aughey, R. J.; Martin, D. T.; Ashenden, M. J.; Clark, S. A. et al. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Live high:train low increases muscle buffer capacity and submaximal cycling efficiency.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Acta Physiol. Scand. 173 (3), S. 275–286&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A. G.; Burge, C. M.; Telford, R. D. (1997)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| VO2max and haemoglobin mass of trained athletes during high intensity training.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 18 (6), S. 477–482&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore C.J.; Hahn A.G.; Scroop G.C.; Watson D.B.; Norton K.I.; Wood R.J.; Campbell D.P. (1996 )&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Increased arterial desaturation in trained cyclists during maximal exercise at 580 m altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Physiol 80(6), S. 2204-10&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A.; Rice, A.; Bourdon, P.; Lawrence, S.; Walsh, C. et al. (1998)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Altitude training at 2690m does not increase total haemoglobin mass or sea level VO2max in world champion track cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 1 (3), S. 156–170&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A. G. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Letter to the editors - Re: Heinicke K, Heinicke I, Schmidt W, Wolfarth B. A three-week traditional altitude training increases hemoglobin mass and red cell volume in elite biathlon athletes. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (6), S. 504-5; author reply 506-7&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore C.J.; Little S.C.; Hahn A.G.; Scroop G.C.; Norton K.I.; Bourdon P.C.; Woolford (1997)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reduced performance of male and female athletes at 580 m altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 75(2), S. 136-43&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; McSharry, P. E.; Hewitt, A. J.; Saunders, P. U. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Preparation for football competition at moderate to high altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Scand J Med Sci Sports 18 Suppl 1, S. 85–95&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, Christopher J.; Rodríguez, Ferran A.; Truijens, Martin J.; Townsend, Nathan E.; Stray-Gundersen, James; Levine, Benjamin D. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Increased serum erythropoietin but not red cell production after 4 wk of intermittent hypobaric hypoxia (4,000-5,500 m).&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 101 (5), S. 1386–1393&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gough, C. E.; Sharpe, K.; Garvican, L. A.; Anson, J. M.; Saunders, P. U.; Gore, C. J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The effects of injury and illness on haemoglobin mass.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 34 (9), S. 763–769&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gough, C.E.; Saunders, P.U.; Fowlie, J.; Savage, B.; Pyne, D.B.; Anson, J.M. et al. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Influence of altitude training modality on performance and total haemoglobin mass in elite swimmers.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 112 (9), S. 3275–3285&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Groslambert, A.; Grappe, F.; Bertucci, W.; Perrey, S.; Girard, A.J.; Rouillon, J.D. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| A perceptive individual time trial performed by triathletes to estimate the anaerobic threshold. A preliminary study.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Med Phys Fitness 44 (2), S. 147–156&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Haakonssen, Eric C.; Martin, David T.; Burke, Louise M.; Jenkins, David G. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Energy expenditure of constant- and variable-intensity cycling: power meter estimates. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 45 (9), S. 1833–1840&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hahn, A. G.; Gore, C. J. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The effect of altitude on cycling performance: a challenge to traditional concepts. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 31 (7), S. 533–557&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hahn, A. G.; Gore, C. J.; Martin, D. T.; Ashenden, M. J.; Roberts, A. D.; Logan, P. A. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Hahn, A. G.; Gore, C. J.; Martin, D. T.; Ashenden, M. J.; Roberts, A. D.; Logan, P. A. (2001) &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Comp. Biochem. Physiol., Part A Mol. Integr. Physiol. 128 (4), S. 777–789&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hajoglou, A.; Foster, C.; Koning, J.J. de; Lucia, A.; Kernozek, T.W.; Porcari, J.P. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effect of warm-up on cycle time trial performance. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 37 (9), S. 1608–1614&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Hopker, J.; Myers, S.; Jobson, S.A.; Bruce, W.; Passfield, L. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of the Wattbike cycle ergometer&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 31 (10), S. 731–736&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Hurst, H.T.; Atkins, S. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Agreement between polar and SRM mobile ergometer systems during laboratory-based high-intensity, intermittent cycling activity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 24 (8), S. 863–868&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hurst, H.T.; Atkins, S. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Power output of field-based downhill mountain biking.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 24 (10), S. 1047–1053&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Davison, R.C.; Coleman, D.A.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The validity of power output recorded during exercise performance tests using a Kingcycle air-braked cycle ergometer when compared with an SRM powermeter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 21 (3), S. 195–199&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Jobson, S.A.; Passfield, L.; Atkinson, G.; Barton, G.; Scarf, P. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The analysis and utilization of cycling training data.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 39 (10), S. 833–844&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Jobson, S.; Woodside, J.; Passfield, L.; Nevill, A. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Allometric Scaling of Uphill Cycling Performance. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (09), S. 753–757&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Joch, W.; Ückert, S. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of Whole Body Cooling of - 110 °C on the Heart Frequency in Endurance Activity and in Resting Time. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| W. Phys Rehab Kur Med  14(3), S. 146-150&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Julian, Colleen G.; Gore, Christopher J.; Wilber, Randall L.; Daniels, Jack T.; Fredericson, Michael; Stray-Gundersen, James et al. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Intermittent normobaric hypoxia does not alter performance or erythropoietic markers in highly trained distance runners.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 96 (5), S. 1800–1807&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Karsten, B.; Jobson, S.A.; Hopker, J.; Passfield, L., Beedie, C. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The 3-min Test Does not Provide a Valid Measure of Critical Power Using the SRM Isokinetic Mode.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med. Sep 10. [Epub ahead of print]&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, T. A.; Gore, C. J.; Hahn, A. G.; Hopkins, W. G.; Hawley, J. A.; McKenna, M. J. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sleep in athletes undertaking protocols of exposure to nocturnal simulated altitude at 2650 m.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 8 (2), S. 222–232&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, T. A.; Hahn, A. G.; Gore, C. J.; Martin, D. T.; Chow, C. M. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sleep quality responses to atmospheric variation: case studies of two elite female cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 6 (4), S. 436–442&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, Tahnee A.; Hahn, Allan G.; Gore, Christopher J.; Wilsmore, Bradley R.; Martin, David T.; Chow, Chin-Moi (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Respiratory events and periodic breathing in cyclists sleeping at 2,650-m simulated altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 92 (5), S. 2114–2118&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, Tahnee A.; Townsend, Nathan E.; Gore, Christopher J.; Hahn, Allan G.; Clark, Sally A.; Aughey, Robert J. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sleep disturbance at simulated altitude indicated by stratified respiratory disturbance index but not hypoxic ventilatory response.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 94 (5-6), S. 569–575&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kirkland, A.; Coleman, D.; Wiles, J.D.; Hopker, J. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of the Ergomopro powermeter.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (11), S. 913–916&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Loughlin, A.F.; Skiles, G.L.; Alberts, D.W.; Schaefer, W.H. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| An ion exchange liquid chromatography/mass spectrometry method for the determination of reduced and oxidized glutathione and glutathione conjugates in hepatocytes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Pharm Biomed Anal 26 (1), S. 131–142&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|MacIntosh, B.R.; Svedahl, K.; Kim, M. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Fatigue and optimal conditions for short-term work capacity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 92 (4-5), S. 369–375&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|MacRae HS-H; Hise, K.J.; Allen, P.J. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of front and dual suspension mountain bike systems on uphill cycling performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 32 (7), S. 1276–1280&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Mc Naughton, L.R.; Sherman, R.; Roberts, S.; Bentley, D.J. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Portable gas analyser Cosmed K4b2 compared to a laboratory based mass spectrometer system.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Med Phys Fitness 45 (3), S. 315–323&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| McDaniel, J.; Subudhi, A.; Martin, J.C. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Torso stabilization reduces the metabolic cost of producing cycling power.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Can J Appl Physiol 30 (4), S. 433–441&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|McLean, Blake D.; Buttifant, David; Gore, Christopher J.; White, Kevin; Liess, Carsten; Kemp, Justin (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Physiological and performance responses to a preseason altitude-training camp in elite team-sport athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 8 (4), S. 391–399&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Meyer, T.; Gabriel, H.H.W.; Auracher, M.; Scharhag, J.; Kindermann, W. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Metabolic profile of 4 h cycling in the field with varying amounts of carbohydrate supply.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 88 (4-5), S. 431–437&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Mijnarends, D.M.; Meijers, J.M.M.; Halfens, R.J.G.; Ter Borg, S.; Luiking, Y.C.; Verlaan, S. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of tools to measure muscle mass, strength, and physical performance in community-dwelling older people: a systematic review.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Am Med Dir Assoc 14 (3), S. 170–178&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Millet, G.P.; Tronche, C.; Fuster, N.; Candau, R. (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Level ground and uphill cycling efficiency in seated and standing positions.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Med Sci Sports Exerc 34 (10), S. 1645–1652&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Millet, G.P.; Tronche, C.; Fuster, N.; Bentley, D.J.; Candau, R. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and reliability of the Polar S710 mobile cycling powermeter.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 24 (3), S. 156–161&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Mornieux, G.; Gollhofer, A.; Stapelfeldt, B. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Muscle Coordination while Pulling up During Cycling. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 31 (12), S. 843–846&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Mornieux, G.; Stapelfeldt, B.; Gollhofer, A.; Belli, A. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effects of Pedal Type and Pull-Up Action during Cycling. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (10), S. 817–822&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Neville, V.; Pain, M.T.G.; Folland, J.P. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Aerobic power and peak power of elite America's Cup sailors. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 106 (1), S. 149–157&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Neville, V.; Pain, M.T.G.; Kantor, J.; Folland, J.P. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Influence of crank length and crank-axle height on standing armcrank (grinding) power.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 42 (2), S. 381–387&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Neville, V.; Zaher, N.; Pain, M.T.G.; Folland, J.P. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Lower limb influence on standing arm-cranking ('grinding').&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 30 (10), S. 713–718&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Neya, Mitsuo; Enoki, Taisuke; Ohiwa, Nao; Kawahara, Takashi; Gore, Christopher J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Increased hemoglobin mass and VO2max with 10 h nightly simulated altitude at 3000 m.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 8 (4), S. 366–372&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Nimmerichter, A.; Eston, R.G.; Bachl, N.; Williams, C. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Longitudinal monitoring of power output and heart rate profiles in elite cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 29 (8), S. 831–840&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Nimmerichter, A.; Williams, C.; Bachl, N.; Eston, R. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Evaluation of a field test to assess performance in elite cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 31 (3), S. 160–166&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|O’Hara, J.; Thomas, A.; Seims, A.; Cooke, C.; King, R.F.G (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reliability of a High-Intensity Endurance Cycling Test.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 33 (01), S. 18–25&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Parisotto, R.; Gore, C. J.; Hahn, A. G.; Ashenden, M. J.; Olds, T. S.; Martin, D. T. et al. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reticulocyte parameters as potential discriminators of recombinant human erythropoietin abuse in elite athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 21 (7), S. 471–479&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Paton, C.D.; Hopkins, W.G. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Tests of cycling performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 31 (7), S. 489–496&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Paton, C.D.; Hopkins, W.G. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Ergometer error and biological variation in power output in a performance test with three cycle ergometers.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 27 (6), S. 444–447&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Caillaud, C.; Thompson, M.W. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Central and Peripheral Fatigue during Passive and Exercise-Induced Hyperthermia &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med. Sci. Sports Exerc. 43 (9), S. 1657 – 1665&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Caillaud, C.; Thompson, M.W. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The role of aerobic fitness and exercise intensity on endurance performance in uncompensable heat stress conditions. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol  112, S. 1989 - 1999&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Cramer, M.N.; Chapman, P.G.; Caillaud, C.; Thompson, M.W. (2011)  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Cardiovascular strain impairs prolonged self-paced exercise in the heat. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Exp Physiol 96 (2), S. 134 - 144&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Cramer, M.N.; Chapman, P.G.; Caillaud, C.; Thompson, M.W. (2011)   &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Neuromuscular function following prolonged intense self-paced exercise in hot climatic conditions. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Physiol. 111, S. 1561 – 1569&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Perrey, S.; Grappe, F.; Girard, A.; Bringard, A.; Groslambert, A.; Bertucci, W.; Rouillon, J.D. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Physiological and metabolic responses of triathletes to a simulated 30-min time-trial in cycling at self-selected intensity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 24 (2), S. 138–143&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Pester, M.; Knorr, K.-H.; Friedrich, M.W.; Wagner, M.; Loy, A. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sulfate-reducing microorganisms in wetlands - fameless actors in carbon cycling and climate change.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Front Microbiol 3, S. 72&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Pinot, J.; Grappe, F. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The record power profile to assess performance in elite cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 32 (11), S. 839–844&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Pottgiesser, Torben; Garvican, Laura A.; Martin, David T.; Featonby, Jesse M.; Gore, Christopher J.; Schumacher, Yorck O. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Short-term hematological effects upon completion of a four-week simulated altitude camp.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Physiol Perform 7 (1), S. 79–83&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Quod, M. J.; Martin, D. T.; Martin, J. C.; Laursen, P. B. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The Power Profile Predicts Road Cycling MMP.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 31 (06), S. 397–401&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Reiser, M.; Meyer, T.; Kindermann, W.; Daugs, R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Transferability of workload measurements between three different types of ergometer.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 82 (3), S. 245–249&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Reiser, R.; Hart, C. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Cycling on Rollers: Kreitler Fan Resistance at Submaximal Levels of Effort.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (3), S. 212–216&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Richalet, J-P; Gore, C. J. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Live and/or sleep high:train low, using normobaric hypoxia.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Scand J Med Sci Sports 18 Suppl 1, S. 29–37&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Roberts, A. D.; Clark, S. A.; Townsend, N. E.; Anderson, M. E.; Gore, C. J.; Hahn, A. G. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Changes in performance, maximal oxygen uptake and maximal accumulated oxygen deficit after 5, 10 and 15 days of live high:train low altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 88 (4-5), S. 390–395&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Robertson, E.Y.; Saunders, P.U.; Pyne, D.B.; Aughey, R.J.; Anson, J.M.; Gore, C.J. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reproducibility of performance changes to simulated live high/train low altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 42 (2), S. 394–401&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Robertson, E.Y.; Saunders, P.U.; Pyne, D.B.; Gore, C.J.; Anson, J.M. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effectiveness of intermittent training in hypoxia combined with live high/train low.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| . J. Appl. Physiol. 110 (2), S. 379–387&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Rodríguez, F.A.; Truijens, M.J.; Townsend, N.E.; Stray-Gundersen, J.; Gore, C.J.; Levine, B.D. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Performance of runners and swimmers after four weeks of intermittent hypobaric hypoxic exposure plus sea level training.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 103 (5), S. 1523–1535&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Sassi, A.; Rampinini, E.; Martin, D.T.; Morelli, A. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of gradient and speed on freely chosen cadence: the key role of crank inertial load.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Biomech 42 (2), S. 171–177&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P. U.; Telford, R. D.; Pyne, D. B.; Cunningham, R. B.; Gore, C. J.; Hahn, A. G.; Hawley, J. A. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Improved running economy in elite runners after 20 days of simulated moderate-altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 96 (3), S. 931–937&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P. U.; Telford, R. D.; Pyne, D. B.; Hahn, A. G.; Gore, C. J. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Improved running economy and increased hemoglobin mass in elite runners after extended moderate altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 12 (1), S. 67–72&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P.U.; Ahlgrim, C.; Vallance, B.; Green, D.J.; Robertson, E.Y.; Clark, S.A. et al. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| An attempt to quantify the placebo effect from a three-week simulated altitude training camp in elite race walkers.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 5 (4), S. 521–534&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P.U.; Pyne, David B.; Gore, C.J. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Endurance training at altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| High Alt. Med. Biol. 10 (2), S. 135–148&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P.U.; Telford, R.D.; Pyne, D.D.; Gore, C.J.; Hahn, A.G. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Improved race performance in elite middle-distance runners after cumulative altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 4 (1), S. 134–138&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Sharpe, K.; Hopkins, W.; Emslie, K.R.; Howe, C.; Trout, G.J.; Kazlauskas, R. et al. (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Development of reference ranges in elite athletes for markers of altered erythropoiesis.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Haematologica 87 (12), S. 1248–1257&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Simons, M.; van Es, E.; Hendriksen, I. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Electrically assisted cycling: a new mode for meeting physical activity guidelines?&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 41 (11), S. 2097–2102&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Smith, M.F.; Davison, R.C.; Balmer, J.; Bird, S.R. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reliability of mean power recorded during indoor and outdoor selfpaced 40 km cycling time-trials.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 22 (4), S. 270–274&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Stapelfeldt, B.; Mornieux, G.; Oberheim, R.; Belli, A.; Gollhofer, A. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Development and evaluation of a new bicycle instrument for measurements of pedal forces and power output in cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 28 (4), S. 326–332&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Stapelfeldt, B.; Schwirtz, A.; Schumacher, Y.O.; Hillebrecht, M. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Workload demands in mountain bike racing.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 25 (4), S. 294–300&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Tomas, A.; Ross, E.Z.; Martin, J.C. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Fatigue during maximal sprint cycling: unique role of cumulative contraction cycles.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 42 (7), S. 1364–1369&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Townsend, N.E.; Gore, C.J.; Hahn, A.G.; Aughey, R.J.; Clark, S.A.; Kinsman, T.A. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Hypoxic ventilatory response is correlated with increased submaximal exercise ventilation after live high, train low.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 94 (1-2), S. 207–215&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Townsend, N.E.; Gore, C.J.; Hahn, A.G.; McKenna, M.J.; Aughey, R.J.; Clark, S.A. et al. (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Living high-training low increases hypoxic ventilatory response of well-trained endurance athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 93 (4), S. 1498–1505&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Truijens, M.J.; Rodríguez, F.A.; Townsend, N.E.; Stray-Gundersen, J.; Gore, C.J.; Levine, B.D. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The effect of intermittent hypobaric hypoxic exposure and sea level training on submaximal economy in well-trained swimmers and runners.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 104 (2), S. 328–337&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Vaile, J.; Halson, S.; Gill, N.; Dawson, B. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effect of Hydrotherapy on Recovery from Fatigue.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 29 (7), S. 539–544&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| van der Woude, L.H.V.; Horstman, A.; Faas, P.; Mechielsen, S.; Bafghi, H.A.; Koning, J.J. de (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Power output and metabolic cost of synchronous and asynchronous submaximal and peak level hand cycling on a motor driven treadmill in able-bodied male subjects.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Med Eng Phys 30 (5), S. 574–580&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Villerius, V.; Duc, S.; Grappe, F. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Physiological and Neuromuscular Responses of Competitive Cyclists during a Simulated Self-Paced Interval Training Session.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (09), S. 770–777&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Vogt, S.; Heinrich, L.; Schumacher, Y. O.; Blum, A.; Roecker, K.; Dickhuth, H.-H.; Schmid, A. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Power output during stage racing in professional road cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 38 (1), S. 147–151&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Vogt, S.; Roecker, K.; Schumacher, Y. O.; Pottgiesser, T.; Dickhuth, H-H; Schmid, A.; Heinrich, L. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Cadence-power-relationship during decisive mountain ascents at the Tour de France.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 29 (3), S. 244–250&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Vogt, S.; Schumacher, Y.O.; Blum, A.; Roecker, K.; Dickhuth, H.-H.; Schmid, A.; Heinrich, L. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Cycling power output produced during flat and mountain stages in the Giro d'Italia: a case study.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Sci 25 (12), S. 1299–1305&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Vogt, S.; Schumacher, Y. O.; Roecker, K.; Dickhuth, H-H; Schoberer, U.; Schmid, A.; Heinrich, L. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Power Output during the Tour de France.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 28 (9), S. 756–761&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wahl, P.; Mathes, S.; Köhler, K.; Achtzehn, S.; Bloch, W.; Mester, J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Acute Metabolic, Hormonal, and Psychological Responses to Different Endurance Training Protocols.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Horm Metab Res 45 (11), S. 827–833&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wahl, P.; Schmidt, A.; deMarees, M.; Achtzehn, S.; Bloch, W.; Mester, J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Responses of Angiogenic Growth Factors to Exercise, to Hypoxia and to Exercise under Hypoxic Conditions.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 34 (02), S. 95–100&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wiedemann, M. S. F.; Bosquet, L. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Anaerobic Work Capacity Derived from Isokinetic and Isoinertial Cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 31 (02), S. 89–94&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wilson, M.G.; Lane, A.M.; Beedie, C.J.; Farooq, A. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Influence of accurate and inaccurate 'split-time' feedback upon 10-mile time trial cycling performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 112 (1), S. 231–236&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wooles, A.L.; Robinson, A.J.; Keen, P.S. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|A Static Method for Obtaining a Calibration Factor for SRM Bicycle Power Cranks.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sports Engineering 8 (3), S. 137-144&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Internationale_Literatur_zum_SRM-Ergometer&amp;diff=2013</id>
		<title>Internationale Literatur zum SRM-Ergometer</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Internationale_Literatur_zum_SRM-Ergometer&amp;diff=2013"/>
				<updated>2016-06-29T08:39:59Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{languages&lt;br /&gt;
|de=Internationale Literatur zum SRM-Ergometer&lt;br /&gt;
|en=International publications on the SRM Ergometer&lt;br /&gt;
|cn=International publications on the SRM Ergometer&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
In der folgenden Tabelle sind  diverese Sammlungen an Publikationen zu verschiedenen Themen als PDF-Dateien verlinkt.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot;&lt;br /&gt;
|+ style=&amp;quot;padding-bottom:1em&amp;quot; | Publikationen des SRM-Ergometers &lt;br /&gt;
|- class=&amp;quot;hintergrundfarbe6&amp;quot;&lt;br /&gt;
!style=&amp;quot;width:60%&amp;quot;| Publikationen!! style=&amp;quot;width:30%&amp;quot;| Letztes Update&lt;br /&gt;
|-&lt;br /&gt;
| [[Media:SRM_Scientific_Publications_06-2016.pdf|SRM Scientific Publications]]&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| Juni 2016 &lt;br /&gt;
|-&lt;br /&gt;
| [[Media:Torque_publications_2015.pdf|Torque Publications]]&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| Januar 2015&lt;br /&gt;
|-&lt;br /&gt;
| [[Media:Eccentric_Chainrings_2015.pdf|Eccentric Chainrings Publications]]&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| April 2015&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* Abbiss, C. R., Quod, M. J., Levin, G., Martin, D. T. &amp;amp; Laursen, P. B. (2009): Accuracy of the Velotron ergometer and SRM power meter. International journal of sports medicine, 30 (2), 107-112. doi: 10.1055/s-0028-1103285.&lt;br /&gt;
* &lt;br /&gt;
* Abbiss, C. R., Quod, M. J., Martin, D. T., Netto, K. J., Nosaka, K., Lee, H. et al. (2006): Dynamic pacing strategies during the cycle phase of an Ironman triathlon. Medicine and science in sports and exercise, 38 (4), 726-734. doi: 10.1249/01.mss.0000210202.33070.55.&lt;br /&gt;
* &lt;br /&gt;
* Abel, T., Burkett, B., Schneider, S., Lindschulten, R. &amp;amp; Strüder, H. K. (2010): The exercise profile of an ultra-long handcycling race: the Styrkeprøven experience. Spinal cord, 48 (12), 894-898. doi: 10.1038/sc.2010.40.&lt;br /&gt;
* &lt;br /&gt;
* Antonutto, G., Capelli, C., Girardis, M., Zamparo, P. &amp;amp; Di Prampero, P. E. (1999): Effects of microgravity on maximal power of lower limbs during very short efforts in humans. Journal of applied physiology (Bethesda, Md, 86 (1), 85-92.&lt;br /&gt;
* &lt;br /&gt;
* Arkesteijn, M., Hopker, J., Jobson, S. &amp;amp; Passfield, L. (2013): The Effect of Turbo Trainer Cycling on Pedalling Technique and Cycling Efficiency. International journal of sports medicine, 34 (06), 520-525. doi: 10.1055/s-0032-1327658.&lt;br /&gt;
* &lt;br /&gt;
* Ashenden, M. J., Gore, C. J., Burge, C. M., Clough, M. L., Bourdon, P. C., Dobson, G. P. et al. (1999): Skin-prick blood samples are reliable for estimating Hb mass with the CO-dilution technique. European journal of applied physiology and occupational physiology, 79 (6), 535-537.&lt;br /&gt;
* &lt;br /&gt;
* Ashenden, M. J., Gore, C. J., Dobson, G. P., Boston, T. T., Parisotto, R., Emslie, K. R. et al. (2000): Simulated moderate altitude elevates serum erythropoietin but does not increase reticulocyte production in well-trained runners. European journal of applied physiology, 81 (5), 428-435. doi: 10.1007/s004210050064.&lt;br /&gt;
* &lt;br /&gt;
* Ashenden, M. J., Gore, C. J., Dobson, G. P. &amp;amp; Hahn, A. G. (1999): &amp;quot;Live high, train low&amp;quot; does not change the total haemoglobin mass of male endurance athletes sleeping at a simulated altitude of 3000 m for 23 nights. European journal of applied physiology and occupational physiology, 80 (5), 479-484.&lt;br /&gt;
* &lt;br /&gt;
* Ashenden, M. J., Gore, C. J., Martin, D. T., Dobson, G. P. &amp;amp; Hahn, A. G. (1999): Effects of a 12-day &amp;quot;live high, train low&amp;quot; camp on reticulocyte production and haemoglobin mass in elite female road cyclists. European journal of applied physiology and occupational physiology, 80 (5), 472-478.&lt;br /&gt;
* &lt;br /&gt;
* Ashenden, M. J., Hahn, A. G., Martin, D. T., Logan, P., Parisotto, R. &amp;amp; Gore, C. J. (2001): A comparison of the physiological response to simulated altitude exposure and r-HuEpo administration. Journal of sports sciences, 19 (11), 831-837. doi: 10.1080/026404101753113778.&lt;br /&gt;
* &lt;br /&gt;
* Ashenden, M. J., Gore, C. J., Parisotto, R., Sharpe, K., Hopkins, W. G. &amp;amp; Hahn, A. G. (2003): Effect of altitude on second-generation blood tests to detect erythropoietin abuse by athletes. Haematologica, 88 (9), 1053-1062.&lt;br /&gt;
* &lt;br /&gt;
* Aughey, R. J., Clark, S. A., Gore, C. J., Townsend, N. E., Hahn, A. G., Kinsman, T. A. et al. (2006): Interspersed normoxia during live high, train low interventions reverses an early reduction in muscle Na+, K +ATPase activity in well-trained athletes. European journal of applied physiology, 98 (3), 299-309. doi: 10.1007/s00421-006-0280-z.&lt;br /&gt;
* &lt;br /&gt;
* Aughey, R. J., Gore, C. J., Hahn, A. G., Garnham, A. P., Clark, S. A., Petersen, A. C. et al. (2005): Chronic intermittent hypoxia and incremental cycling exercise independently depress muscle in vitro maximal Na+-K+-ATPase activity in well-trained athletes. Journal of applied physiology (Bethesda, Md. : 1985), 98 (1), 186-192. doi: 10.1152/japplphysiol.01335.2003.&lt;br /&gt;
* &lt;br /&gt;
* Austin, N., Nilwik, R. &amp;amp; Herzog, W. (2010): In vivo operational fascicle lengths of vastus lateralis during sub-maximal and maximal cycling. Journal of biomechanics, 43 (12), 2394-2399. doi: 10.1016/j.jbiomech.2010.04.016.&lt;br /&gt;
* &lt;br /&gt;
* Balmer, J., Davison, R. C. &amp;amp; Bird, S. R. (2000): Peak power predicts performance power during an outdoor 16.1-km cycling time trial. Medicine and science in sports and exercise, 32 (8), 1485-1490.&lt;br /&gt;
* &lt;br /&gt;
* Balmer, J., Davison, R. C. &amp;amp; Bird, S. R. (2000): Reliability of an air-braked ergometer to record peak power during a maximal cycling test. Medicine and science in sports and exercise, 32 (10), 1790-1793.Balmer, Davison et al. 2000 – The validity of power output&lt;br /&gt;
* &lt;br /&gt;
* Balmer, J., Davison, R. C., Coleman, D. A. &amp;amp; Bird, S. R. (2000): The validity of power output recorded during exercise performance tests using a Kingcycle air-braked cycle ergometer when compared with an SRM powermeter. International journal of sports medicine, 21 (3), 195-199. doi: 10.1055/s-2000-9466.&lt;br /&gt;
* &lt;br /&gt;
* Balmer, J., Bird, S., Davison, R. C. R., Doherty, M. &amp;amp; Smith, P. (2004): Mechanically braked Wingate powers: agreement between SRM, corrected and conventional methods of measurement. Journal of sports sciences, 22 (7), 661-667. doi: 10.1080/02640410310001655831.&lt;br /&gt;
* &lt;br /&gt;
* Balmer, J., Bird, S., Davison, R. &amp;amp; Lucia, A. (2008): Effect of age on 16.1-km time-trial performance. Journal of sports sciences, 26 (2), 197-206. doi: 10.1080/02640410701446901.&lt;br /&gt;
* &lt;br /&gt;
* Barratt, P. (2008): SRM Torque Analysis of Standing Starts in Track Cycling (P85). In  The Engineering of Sport 7 (Volume 1, S. 443-448).&lt;br /&gt;
* &lt;br /&gt;
* Bassett, D. R., Kyle, C. R., Passfield, L., Broker, J. P. &amp;amp; Burke, E. R. (1999): Comparing cycling world hour records, 1967-1996: modeling with empirical data. Medicine and science in sports and exercise, 31 (11), 1665-1676.&lt;br /&gt;
* &lt;br /&gt;
* Bentley, D. J., McNaughton, L. R., Thompson, D., Vleck, V. E. &amp;amp; Batterham, A. M. (2001): Peak power output, the lactate threshold, and time trial performance in cyclists. Medicine and science in sports and exercise, 33 (12), 2077-2081.&lt;br /&gt;
* &lt;br /&gt;
* Bertucci, W., Crequy, S. &amp;amp; Chiementin, X. (2012). Validity and Reliability of the G-Cog BMX Powermeter. International journal of sports medicine. doi: 10.1055/s-0031-1301319.&lt;br /&gt;
* &lt;br /&gt;
* Bertucci, W., Duc, S., Villerius, V. &amp;amp; Grappe, F. (2005): Validity and reliability of the Axiom PowerTrain cycle ergometer when compared with an SRM powermeter. International journal of sports medicine, 26 (1), 59-65. doi: 10.1055/s-2004-817855.&lt;br /&gt;
* &lt;br /&gt;
* Bertucci, W., Duc, S., Villerius, V., Pernin, J. N. &amp;amp; Grappe, F. (2005): Validity and reliability of the PowerTap mobile cycling powermeter when compared with the SRM Device. International journal of sports medicine, 26 (10), 868-873. doi: 10.1055/s-2005-837463.&lt;br /&gt;
* &lt;br /&gt;
* Bertucci, W., Taiar, R. &amp;amp; Grappe, F. (2005): Differences between sprint tests under laboratory and actual cycling conditions. The Journal of sports medicine and physical  fitness, 45 (3), 277-283.&lt;br /&gt;
* &lt;br /&gt;
* Bertucci, W., Grappe, F., Girard, A., Betik, A. &amp;amp; Rouillon, J. D. (2005): Effects on the crank torque profile when changing pedalling cadence in level ground and uphill road cycling. Journal of biomechanics, 38 (5), 1003-1010. doi: 10.1016/j.jbiomech.2004.05.037.&lt;br /&gt;
* &lt;br /&gt;
* Bertucci, W., Grappe, F. &amp;amp; Groslambert, A. (2007): Laboratory versus outdoor cycling conditions: differences in pedaling biomechanics. Journal of applied biomechanics, 23 (2), 87-92.&lt;br /&gt;
* &lt;br /&gt;
* Billaut, F., Gore, C. J. &amp;amp; Aughey, R. J. (2012): Enhancing team-sport athlete performance: is altitude training relevant? Sports medicine (Auckland, N.Z.), 42 (9), 751-767. doi: 10.2165/11634050-000000000-00000.&lt;br /&gt;
* &lt;br /&gt;
* Brickley, G., Dekerle, J., Hammond, A., Pringle, J. &amp;amp; Carter, H. (2007): Assessment of Maximal Aerobic Power and Critical Power in a Single 90-s Isokinetic All-Out Cycling Test. International journal of sports medicine, 28 (5), 414-419. doi: 10.1055/s-2006-924513.&lt;br /&gt;
* &lt;br /&gt;
* Broker, J. P., Kyle, C. R. &amp;amp; Burke, E. R. (1999): Racing cyclist power requirements in the 4000-m individual and team pursuits. Medicine and science in sports and exercise, 31 (11), 1677-1685.&lt;br /&gt;
* &lt;br /&gt;
* Brosnan, M. J., Martin, D. T., Hahn, A. G., Gore, C. J. &amp;amp; Hawley, J. A. (2000): Impaired interval exercise responses in elite female cyclists at moderate simulated altitude. Journal of applied physiology (Bethesda, Md. : 1985), 89 (5), 1819-1824.&lt;br /&gt;
* &lt;br /&gt;
* Cangley, P., Passfield, L., Carter, H. &amp;amp; Bailey, M. (2011): The Effect of Variable Gradients on Pacing in Cycling Time-Trials. International journal of sports medicine, 32 (02), 132-136. doi: 10.1055/s-0030-1268440.&lt;br /&gt;
* &lt;br /&gt;
* Carpes, F. P., Rossato, M., Faria, I. E. &amp;amp; Bolli Mota, C. (2007): Bilateral pedaling asymmetry during a simulated 40-km cycling time-trial. The Journal of sports medicine and physical fitness, 47 (1), 51-57.&lt;br /&gt;
* &lt;br /&gt;
* Clark, S. A., Bourdon, P. C., Schmidt, W., Singh, B., Cable, G., Onus, K. J. et al. (2007): The effect of acute simulated moderate altitude on power, performance and pacing strategies in well-trained cyclists. European journal of applied physiology, 102 (1), 45-55. doi: 10.1007/s00421-007-0554-0.&lt;br /&gt;
* &lt;br /&gt;
* Clark, S. A., Quod, M. J., Clark, M. A., Martin, D. T., Saunders, P. U. &amp;amp; Gore, C. J. (2009): Time course of haemoglobin mass during 21 days live high:train low simulated altitude. European journal of applied physiology, 106 (3), 399-406. doi: 10.1007/s00421-009-1027-4.&lt;br /&gt;
* &lt;br /&gt;
* Clark, S. K. &amp;amp; Johnson, T. M. (2010): Selenium stable isotope investigation into selenium biogeochemical cycling in a lacustrine environment: Sweitzer Lake, Colorado. Journal of environmental quality, 39 (6), 2200-2210.&lt;br /&gt;
* &lt;br /&gt;
* Coleman, D. A., Wiles, J. D., Nunn, M. &amp;amp; Smith, M. F. (2005): Reliability of sprint test indices in well-trained cyclists. International journal of sports medicine, 26 (5), 383-387. doi: 10.1055/s-2004-821226.&lt;br /&gt;
* &lt;br /&gt;
* Doherty, M., Balmer, J., Davison, R. C. R., Robinson, L. &amp;amp; Smith, P. M. (2003): Reliability of a combined 3-min constant load and performance cycling test. International journal of sports medicine, 24 (5), 366-371. doi: 10.1055/s-2003-40700.&lt;br /&gt;
* &lt;br /&gt;
* Duc, S., Betik, A.-C. &amp;amp; Grappe, F. (2005): EMG activity does not change during a time trial in competitive cyclists. International journal of sports medicine, 26 (2), 145-150. doi: 10.1055/s-2004-817922.&lt;br /&gt;
* &lt;br /&gt;
* Duc, S., Villerius, V., Bertucci, W. &amp;amp; Grappe, F. (2007): Validity and reproducibility of the ErgomoPro power meter compared  with the SRM and Powertap power meters. International journal of sports physiology and performance, 2 (3), 270-281.&lt;br /&gt;
* &lt;br /&gt;
* Duc, S., Villerius, V., Bertucci, W., Pernin, J. N. &amp;amp; Grappe, F. (2005): Muscular activity level during pedalling is not affected by crank inertial load. European journal of applied physiology, 95 (2-3), 260-264. doi: 10.1007/s00421-005-1401-9.&lt;br /&gt;
* &lt;br /&gt;
* Duc, S., Villerius, V., Bertucci, W. &amp;amp; Grappe, F. (2007): Validity and reproducibility of the ErgomoPro power meter compared with the SRM and Powertap power meters. International journal of sports physiology and performance, 2 (3), 270-281.&lt;br /&gt;
* &lt;br /&gt;
* Eastwood, A., Sharpe, K., Bourdon, P. C., Woolford, S. M., Saunders, P. U., Robertson, E. Y. et al. (2012): Within-subject variation in hemoglobin mass in elite athletes. Medicine and science in sports and exercise, 44 (4), 725-732. doi: 10.1249/MSS.0b013e318238ea7f.&lt;br /&gt;
* &lt;br /&gt;
* Ebert, T. R., Martin, D. T., McDonald, W., Victor, J., Plummer, J. &amp;amp; Withers, R. T. (2005): Power output during women's World Cup road cycle racing. European journal of applied physiology, 95 (5-6), 529-536. doi: 10.1007/s00421-005-0039-y.&lt;br /&gt;
* &lt;br /&gt;
* Ebert, T. R., Martin, D. T., Stephens, B. &amp;amp; Withers, R. T. (2006): Power output during a professional men's road-cycling tour. International journal of sports physiology and performance, 1 (4), 324-335.&lt;br /&gt;
* &lt;br /&gt;
* Emonson, D. L., Aminuddin, A. H., Wight, R. L., Scroop, G. C. &amp;amp; Gore, C. J. (1997): Training-induced increases in sea level VO2max and endurance are not enhanced by acute hypobaric exposure. European journal of applied physiology and occupational physiology, 76 (1), 8-12.&lt;br /&gt;
* &lt;br /&gt;
* Faiss, R., Praz, M., Meichtry, A., Gobelet, C. &amp;amp; Deriaz, O. (2007): The effect of mountain bike suspensions on vibrations and off-road uphill performance. The Journal of sports medicine and physical fitness, 47 (2), 151-158.&lt;br /&gt;
* &lt;br /&gt;
* Frese, S., Valdivieso, P., Jaecker, V. C., Harms, S. A., Konou, T. M., Tappe, K. A. et al. (2016): Expression of Metabolic and Myogenic Factors during two Competitive Seasons in Elite Junior Cyclists. Deutsche Zeitschrift für Sportmedizin, 2016 (06), 150-158. doi: 10.5960/dzsm.2016.239.&lt;br /&gt;
* &lt;br /&gt;
* Fu, Q., Townsend, N. E., Shiller, S. M., Martini, E. R., Okazaki, K., Shibata, S. et al. (2007): Intermittent hypobaric hypoxia exposure does not cause sustained alterations in autonomic control of blood pressure in young athletes. American journal of physiology. Regulatory, integrative and comparative physiology, 292 (5), R1977-84. doi: 10.1152/ajpregu.00622.2006.&lt;br /&gt;
* &lt;br /&gt;
* Gardner, A. S., Martin, D. T., Jenkins, D. G., Dyer, I., van Eiden, J., Barras, M. et al. (2009): Velocity-specific fatigue: quantifying fatigue during variable velocity cycling. Medicine and science in sports and exercise, 41 (4), 904-911. doi: 10.1249/MSS.0b013e318190c2cc.&lt;br /&gt;
* &lt;br /&gt;
* Gardner, A. S., Martin, J. C., Martin, D. T., Barras, M. &amp;amp; Jenkins, D. G. (2007): Maximal torque- and power-pedaling rate relationships for elite sprint cyclists in laboratory and field tests. European journal of applied physiology, 101 (3), 287-292. doi: 10.1007/s00421-007-0498-4.&lt;br /&gt;
* &lt;br /&gt;
* Gardner, A. S., Stephens, S., Martin, D. T., Lawton, E., Lee, H. &amp;amp; Jenkins, D. (2004): Accuracy of SRM and power tap power monitoring systems for bicycling. Medicine and science in sports and exercise, 36 (7), 1252-1258.&lt;br /&gt;
* &lt;br /&gt;
* Garvican, L. A., Hammond, K., Varley, M. C., Gore, C. J., Billaut, F. &amp;amp; Aughey, R. J. (2013): Lower Running Performance and Exacerbated Fatigue in Soccer Played at 1600 m. International journal of sports physiology and performance.&lt;br /&gt;
* &lt;br /&gt;
* Garvican, L. A., Martin, D. T., Clark, S. A., Schmidt, W. F. &amp;amp; Gore, C. J. (2007): Variability of erythropoietin response to sleeping at simulated altitude: a cycling case study. International journal of sports physiology and performance, 2 (3), 327-331.&lt;br /&gt;
* &lt;br /&gt;
* Garvican, L. A., Pottgiesser, T., Martin, D. T., Schumacher, Y. O., Barras, M. &amp;amp; Gore, C. J. (2011): The contribution of haemoglobin mass to increases in cycling performance induced by simulated LHTL. European journal of applied physiology, 111 (6), 1089-1101. doi: 10.1007/s00421-010-1732-z.&lt;br /&gt;
* &lt;br /&gt;
* Garvican, L. A., Saunders, P. U., Pyne, D. B., Martin, D. T., Robertson, E. Y. &amp;amp; Gore, C. J. (2012): Hemoglobin mass response to simulated hypoxia &amp;quot;blinded&amp;quot; by noisy measurement? Journal of applied physiology (Bethesda, Md. : 1985), 112 (10), 1797-8; author reply 1799. doi: 10.1152/japplphysiol.00212.2012.&lt;br /&gt;
* &lt;br /&gt;
* Giacomoni, M., Billaut, F. &amp;amp; Falgairette, G. (2006): Effects of the Time of Day on Repeated All-Out Cycle Performance and Short-Term Recovery Patterns. International journal of sports medicine, 27 (6), 468-474. doi: 10.1055/s-2005-865822.&lt;br /&gt;
* &lt;br /&gt;
* González-Haro, C., Galilea, P. A. &amp;amp; Escanero, J. F. (2008):Comparison of different theoretical models estimating peak power output and maximal oxygen uptake in trained and elite triathletes and endurance cyclists in the velodrome. Journal of sports sciences, 26 (6), 591-601. doi: 10.1080/02640410701646245.&lt;br /&gt;
* &lt;br /&gt;
* González-Haro, C., Galilea Ballarini, P. A., Soria, M., Drobnic, F. &amp;amp; Escanero, J. F. (2007): Comparison of nine theoretical models for estimating the mechanical power output in cycling. British journal of sports medicine, 41 (8), 506-9; discussion 509. doi: 10.1136/bjsm.2006.034934.&lt;br /&gt;
* &lt;br /&gt;
* Goosey-Tolfrey, V., Castle, P., Webborn, N. &amp;amp; Abel, T. (2006). Aerobic capacity and peak power output of elite quadriplegic games players. British journal of sports medicine, 40 (8), 684-687. doi: 10.1136/bjsm.2006.026815.&lt;br /&gt;
* &lt;br /&gt;
* Gordon, R. S., Franklin, K. L., Davies, B. &amp;amp; Baker, J. S. (2007): Further mechanical considerations between polar and SRM mobile ergometer systems during laboratory-based high-intensity, intermittent cycling activity. Research in sports medicine (Print), 15 (4), 241-247. doi: 10.1080/15438620701525540.&lt;br /&gt;
* &lt;br /&gt;
* Gore, C. J., Hahn, A., Rice, A., Bourdon, P., Lawrence, S., Walsh, C. et al. (1998): Altitude training at 2690m does not increase total haemoglobin mass or sea level VO2max in world champion track cyclists. Journal of science and medicine in sport / Sports Medicine Australia, 1 (3), 156-170.&lt;br /&gt;
* &lt;br /&gt;
* Gore, C. J. &amp;amp; Hahn, A. G. (2005): Letter to the editors - Re: Heinicke K, Heinicke I, Schmidt W, Wolfarth B. A three-week traditional altitude training increases hemoglobin mass and red cell volume in elite biathlon athletes. Int J Sports Med 2005; 26: 350-355. International journal of sports medicine, 26 (6), 504-5; author reply 506-7. doi: 10.1055/s-2005-865832.&lt;br /&gt;
* &lt;br /&gt;
* Gore, C. J., Hahn, A. G., Aughey, R. J., Martin, D. T., Ashenden, M. J., Clark, S. A. et al. (2001): Live high:train low increases muscle buffer capacity and submaximal cycling efficiency. Acta physiologica Scandinavica, 173 (3), 275-286. doi: 10.1046/j.1365-201X.2001.00906.x.&lt;br /&gt;
* &lt;br /&gt;
* Gore, C. J., Hahn, A. G., Burge, C. M. &amp;amp; Telford, R. D. (1997): VO2max and haemoglobin mass of trained athletes during high intensity training. International journal of sports medicine, 18 (6), 477-482. doi: 10.1055/s-2007-972667.&lt;br /&gt;
* &lt;br /&gt;
* Gore, C. J., Hahn, A. G., Scroop, G. C., Watson, D. B., Norton, K. I., Wood, R. J. et al. (1996): Increased arterial desaturation in trained cyclists during maximal exercise at 580 m altitude. Journal of applied physiology (Bethesda, Md. : 1985), 80 (6), 2204-2210.&lt;br /&gt;
* &lt;br /&gt;
* Gore, C. J., Little, S. C., Hahn, A. G., Scroop, G. C., Norton, K. I., Bourdon, P. C. et al. (1997): Reduced performance of male and female athletes at 580 m altitude. European journal of applied physiology and occupational physiology, 75 (2), 136-143.&lt;br /&gt;
* &lt;br /&gt;
* Gore, C. J., McSharry, P. E., Hewitt, A. J. &amp;amp; Saunders, P. U. (2008): Preparation for football competition at moderate to high altitude. Scandinavian journal of medicine &amp;amp; science in sports, 18 Suppl 1, 85-95. doi: 10.1111/j.1600-0838.2008.00836.x.&lt;br /&gt;
* &lt;br /&gt;
* Gore, C. J., Rodríguez, F. A., Truijens, M. J., Townsend, N. E., Stray-Gundersen, J. &amp;amp; Levine, B. D. (2006): Increased serum erythropoietin but not red cell production after 4 wk of intermittent hypobaric hypoxia (4,000-5,500 m). Journal of applied physiology (Bethesda, Md. : 1985), 101 (5), 1386-1393. doi: 10.1152/japplphysiol.00342.2006.&lt;br /&gt;
* &lt;br /&gt;
* Gore, C. J., Clark, S. A. &amp;amp; Saunders, P. U. (2007): Nonhematological mechanisms of improved sea-level performance after hypoxic exposure. Medicine and science in sports and exercise, 39 (9), 1600-1609. doi: 10.1249/mss.0b013e3180de49d3.&lt;br /&gt;
* &lt;br /&gt;
* Gough, C. E., Sharpe, K., Garvican, L. A., Anson, J. M., Saunders, P. U. &amp;amp; Gore, C. J. (2013): The effects of injury and illness on haemoglobin mass. International journal of sports medicine, 34 (9), 763-769. doi: 10.1055/s-0033-1333692.&lt;br /&gt;
* &lt;br /&gt;
* Gough, C. E., Saunders, P. U., Fowlie, J., Savage, B., Pyne, D. B., Anson, J. M. et al. (2012): Influence of altitude training modality on performance and total haemoglobin mass in elite swimmers. European journal of applied physiology, 112 (9), 3275-3285. doi: 10.1007/s00421-011-2291-7.&lt;br /&gt;
* &lt;br /&gt;
* Groslambert, A., Grappe, F., Bertucci, W., Perrey, S., Girard, A. J. &amp;amp; Rouillon, J. D. (2004): A perceptive individual time trial performed by triathletes to estimate the anaerobic threshold. A preliminary study. The Journal of sports medicine and physical fitness, 44 (2), 147-156.&lt;br /&gt;
* &lt;br /&gt;
* Haakonssen, E. C., Martin, D. T., Burke, L. M. &amp;amp; Jenkins, D. G. (2013): Energy expenditure of constant- and variable-intensity cycling: power meter estimates. Medicine and science in sports and exercise, 45 (9), 1833-1840. doi: 10.1249/MSS.0b013e31828e18e6.&lt;br /&gt;
* &lt;br /&gt;
* Hahn, A. G. &amp;amp; Gore, C. J. (2001): The effect of altitude on cycling performance: a challenge to traditional concepts. Sports medicine (Auckland, N.Z.), 31 (7), 533-557.&lt;br /&gt;
* &lt;br /&gt;
* Hahn, A. G., Gore, C. J., Martin, D. T., Ashenden, M. J., Roberts, A. D. &amp;amp; Logan, P. A. (2001): An evaluation of the concept of living at moderate altitude and training at sea level. Comparative biochemistry and physiology. Part A, Molecular &amp;amp; integrative physiology, 128 (4), 777-789.&lt;br /&gt;
* &lt;br /&gt;
* Hajoglou, A., Foster, C., Koning, J. J. de, Lucia, A., Kernozek, T. W. &amp;amp; Porcari, J. P. (2005): Effect of warm-up on cycle time trial performance. Medicine and science in sports and exercise, 37 (9), 1608-1614.&lt;br /&gt;
* &lt;br /&gt;
* Hopker, J., Myers, S., Jobson, S. A., Bruce, W. &amp;amp; Passfield, L. (2010): Validity and reliability of the Wattbike cycle ergometer. International journal of sports medicine, 31 (10), 731-736. doi: 10.1055/s-0030-1261968.&lt;br /&gt;
* &lt;br /&gt;
* Hurst, H. T. &amp;amp; Atkins, S. (2006): Agreement between polar and SRM mobile ergometer systems during laboratory-based high-intensity, intermittent cycling activity. Journal of sports sciences, 24 (8), 863-868. doi: 10.1080/02640410500245678.&lt;br /&gt;
* &lt;br /&gt;
* Hurst, H. T. &amp;amp; Atkins, S. (2006): Power output of field-based downhill mountain biking. Journal of sports sciences, 24 (10), 1047-1053. doi: 10.1080/02640410500431997.&lt;br /&gt;
* &lt;br /&gt;
* Jobson, S., Woodside, J., Passfield, L. &amp;amp; Nevill, A. (2008): Allometric Scaling of Uphill Cycling Performance. International journal of sports medicine, 29 (09), 753-757. doi: 10.1055/s-2007-989441.&lt;br /&gt;
* &lt;br /&gt;
* Jobson, S. A., Passfield, L., Atkinson, G., Barton, G. &amp;amp; Scarf, P. (2009): The analysis and utilization of cycling training data. Sports medicine (Auckland, N.Z.), 39 (10), 833-844. doi: 10.2165/11317840-000000000-00000.&lt;br /&gt;
* &lt;br /&gt;
* Julian, C. G., Gore, C. J., Wilber, R. L., Daniels, J. T., Fredericson, M., Stray-Gundersen, J. et al. (2004): Intermittent normobaric hypoxia does not alter performance or erythropoietic markers in highly trained distance runners. Journal of applied physiology (Bethesda, Md. : 1985), 96 (5), 1800-1807. doi: 10.1152/japplphysiol.00969.2003.&lt;br /&gt;
* &lt;br /&gt;
* Karsten, B., Jobson, S. A., Hopker, J., Jimenez, A. &amp;amp; Beedie, C. (2014): High Agreement between Laboratory and Field Estimates of Critical Power in Cycling. International journal of sports medicine, 35 (4), 298-303. doi: 10.1055/s-0033-1349844.&lt;br /&gt;
* &lt;br /&gt;
* Karsten, B., Jobson, S. A., Hopker, J., Passfield, L. &amp;amp; Beedie, C. (2013): The 3-min Test Does not Provide a Valid Measure of Critical Power Using the SRM Isokinetic Mode. International journal of sports medicine. doi: 10.1055/s-0033-1349093.&lt;br /&gt;
* &lt;br /&gt;
* Kinsman, T. A., Gore, C. J., Hahn, A. G., Hopkins, W. G., Hawley, J. A., McKenna, M. J. et al. (2005): Sleep in athletes undertaking protocols of exposure to nocturnal simulated altitude at 2650 m. Journal of science and medicine in sport / Sports Medicine Australia, 8 (2), 222-232.&lt;br /&gt;
* &lt;br /&gt;
* Kinsman, T. A., Hahn, A. G., Gore, C. J., Martin, D. T. &amp;amp; Chow, C. M. (2003): Sleep quality responses to atmospheric variation: case studies of two elite female cyclists. Journal of science and medicine in sport / Sports Medicine Australia, 6 (4), 436-442.&lt;br /&gt;
* &lt;br /&gt;
* Kinsman, T. A., Hahn, A. G., Gore, C. J., Wilsmore, B. R., Martin, D. T. &amp;amp; Chow, C.-M. (2002): Respiratory events and periodic breathing in cyclists sleeping at 2,650-m simulated altitude. Journal of applied physiology (Bethesda, Md. : 1985), 92 (5), 2114-2118. doi: 10.1152/japplphysiol.00737.2001.&lt;br /&gt;
* &lt;br /&gt;
* Kinsman, T. A., Townsend, N. E., Gore, C. J., Hahn, A. G., Clark, S. A., Aughey, R. J. et al. (2005): Sleep disturbance at simulated altitude indicated by stratified respiratory disturbance index but not hypoxic ventilatory response. European journal of applied physiology, 94 (5-6), 569-575. doi: 10.1007/s00421-005-1368-6.&lt;br /&gt;
* &lt;br /&gt;
* Kirkland, A., Coleman, D., Wiles, J. D. &amp;amp; Hopker, J. (2008): Validity and reliability of the Ergomopro powermeter. International journal of sports medicine, 29 (11), 913-916. doi: 10.1055/s-2008-1038621.&lt;br /&gt;
* &lt;br /&gt;
* Loughlin, A. F., Skiles, G. L., Alberts, D. W. &amp;amp; Schaefer, W. H. (2001): An ion exchange liquid chromatography/mass spectrometry method for the determination of reduced and oxidized glutathione and glutathione conjugates in hepatocytes. Journal of pharmaceutical and biomedical analysis, 26 (1), 131-142.&lt;br /&gt;
* &lt;br /&gt;
* MacIntosh, B. R., Svedahl, K. &amp;amp; Kim, M. (2004): Fatigue and optimal conditions for short-term work capacity. European journal of applied physiology, 92 (4-5), 369-375. doi: 10.1007/s00421-004-1177-3.&lt;br /&gt;
* &lt;br /&gt;
* MacRae HS-H, Hise, K. J. &amp;amp; Allen, P. J. (2000): Effects of front and dual suspension mountain bike systems on uphill cycling performance. Medicine and science in sports and exercise, 32 (7), 1276-1280.&lt;br /&gt;
* &lt;br /&gt;
* Maier, T., Steiner, T., Trösch, S., Müller, B. &amp;amp; Wehrlin, J. P. (2014): Reliability of power meter calibration by mathematical modelling of treadmill cycling. J Sci Cycling (Vol. 3(2), 28).&lt;br /&gt;
* &lt;br /&gt;
* Mc Naughton, L. R., Sherman, R., Roberts, S. &amp;amp; Bentley, D. J. (2005): Portable gas analyser Cosmed K4b2 compared to a laboratory based mass spectrometer system. The Journal of sports medicine and physical fitness, 45 (3), 315-323.&lt;br /&gt;
* &lt;br /&gt;
* McDaniel, J., Subudhi, A. &amp;amp; Martin, J. C. (2005): Torso stabilization reduces the metabolic cost of producing cycling power. Canadian journal of applied physiology = Revue canadienne de physiologie appliquée, 30 (4), 433-441.&lt;br /&gt;
* &lt;br /&gt;
* McLean, B. D., Buttifant, D., Gore, C. J., White, K., Liess, C. &amp;amp; Kemp, J. (2013): Physiological and performance responses to a preseason altitude-training camp in elite team-sport athletes. International journal of sports physiology and performance, 8 (4), 391-399.&lt;br /&gt;
* &lt;br /&gt;
* Menaspa, P., Quod, M., Martin, D. T., Peiffer, J. J. &amp;amp; Abbiss, C. R. (2015): Physical Demands of Sprinting in Professional Road Cycling. International journal of sports medicine, 36 (13), 1058-1062. doi: 10.1055/s-0035-1554697.&lt;br /&gt;
* &lt;br /&gt;
* Meyer, T., Gabriel, H. H. W., Auracher, M., Scharhag, J. &amp;amp; Kindermann, W. (2003): Metabolic profile of 4 h cycling in the field with varying amounts of carbohydrate supply. European journal of applied physiology, 88 (4-5), 431-437. doi: 10.1007/s00421-002-0712-3.&lt;br /&gt;
* &lt;br /&gt;
* Mijnarends, D. M., Meijers, J. M. M., Halfens, R. J. G., Ter Borg, S., Luiking, Y. C., Verlaan, S. et al. (2013): Validity and reliability of tools to measure muscle mass, strength, and physical performance in community-dwelling older people: a systematic review. Journal of the American Medical Directors Association, 14 (3), 170-178. doi: 10.1016/j.jamda.2012.10.009.&lt;br /&gt;
* &lt;br /&gt;
* Millet, G. P., Tronche, C., Fuster, N., Bentley, D. J. &amp;amp; Candau, R. (2003): Validity and reliability of the Polar S710 mobile cycling powermeter. International journal of sports medicine, 24 (3), 156-161. doi: 10.1055/s-2003-39083.&lt;br /&gt;
* &lt;br /&gt;
* Millet, G. P., Tronche, C., Fuster, N. &amp;amp; Candau, R. (2002): Level ground and uphill cycling efficiency in seated and standing positions. Medicine and science in sports and exercise, 34 (10), 1645-1652. doi: 10.1249/01.MSS.0000031482.14781.D7.&lt;br /&gt;
* &lt;br /&gt;
* Mornieux, G., Gollhofer, A. &amp;amp; Stapelfeldt, B. (2010): Muscle Coordination while Pulling up During Cycling. International journal of sports medicine, 31 (12), 843-846. doi: 10.1055/s-0030-1263140.&lt;br /&gt;
* &lt;br /&gt;
* Mornieux, G., Stapelfeldt, B., Gollhofer, A. &amp;amp; Belli, A. (2008): Effects of Pedal Type and Pull-Up Action during Cycling: International journal of sports medicine, 29 (10), 817-822. doi: 10.1055/s-2008-1038374.&lt;br /&gt;
* &lt;br /&gt;
* Neville, V., Zaher, N., Pain, M. T. G. &amp;amp; Folland, J. P. (2009): Lower limb influence on standing arm-cranking ('grinding'). International journal of sports medicine, 30 (10), 713-718. doi: 10.1055/s-0029-1231044.&lt;br /&gt;
* &lt;br /&gt;
* Neville, V., Pain, M. T. G. &amp;amp; Folland, J. P. (2009): Aerobic power and peak power of elite America's Cup sailors. European journal of applied physiology, 106 (1), 149-157. doi: 10.1007/s00421-009-1002-0.&lt;br /&gt;
* &lt;br /&gt;
* Neville, V., Pain, M. T. G., Kantor, J. &amp;amp; Folland, J. P. (2010): Influence of crank length and crank-axle height on standing arm-crank (grinding) power. Medicine and science in sports and exercise, 42 (2), 381-387. doi: 10.1249/MSS.0b013e3181b46f3a.&lt;br /&gt;
* &lt;br /&gt;
* Neya, M., Enoki, T., Ohiwa, N., Kawahara, T. &amp;amp; Gore, C. J. (2013) Increased hemoglobin mass and VO2max with 10 h nightly simulated altitude at 3000 m. International journal of sports physiology and performance, 8 (4), 366-372.&lt;br /&gt;
* &lt;br /&gt;
* Nimmerichter, A., Williams, C., Bachl, N. &amp;amp; Eston, R. (2010): Evaluation of a field test to assess performance in elite cyclists. International journal of sports medicine, 31 (3), 160-166. doi: 10.1055/s-0029-1243222.&lt;br /&gt;
* &lt;br /&gt;
* Nimmerichter, A., Eston, R. G., Bachl, N. &amp;amp; Williams, C. (2011): Longitudinal monitoring of power output and heart rate profiles in elite cyclists. Journal of sports sciences, 29 (8), 831-840. doi: 10.1080/02640414.2011.561869.&lt;br /&gt;
* &lt;br /&gt;
* Nimmerichter, A. &amp;amp; Williams, C. A. (2015): Comparison of power output during ergometer and track cycling in adolescent cyclists. Journal of strength and conditioning research / National Strength &amp;amp; Conditioning Association, 29 (4), 1049-1056. doi: 10.1519/JSC.0000000000000723.&lt;br /&gt;
* &lt;br /&gt;
* O’Hara, J., Thomas, A., Seims, A., Cooke, C. &amp;amp; King, R. (2012): Reliability of a High-Intensity Endurance Cycling Test. International journal of sports medicine, 33 (01), 18-25. doi: 10.1055/s-0031-1284340.&lt;br /&gt;
* &lt;br /&gt;
* Parisotto, R., Gore, C. J., Hahn, A. G., Ashenden, M. J., Olds, T. S., Martin, D. T. et al. (2000): Reticulocyte parameters as potential discriminators of recombinant human erythropoietin abuse in elite athletes. International journal of sports medicine, 21 (7), 471-479. doi: 10.1055/s-2000-7421.&lt;br /&gt;
* &lt;br /&gt;
* Paton, C. D. &amp;amp; Hopkins, W. G. (2001): Tests of cycling performance. Sports medicine (Auckland, N.Z.), 31 (7), 489-496.&lt;br /&gt;
* &lt;br /&gt;
* Paton, C. D. &amp;amp; Hopkins, W. G. (2006): Ergometer error and biological variation in power output in a performance test with three cycle ergometers. International journal of sports medicine, 27 (6), 444-447. doi: 10.1055/s-2005-865781.&lt;br /&gt;
* &lt;br /&gt;
* Périard, J. D., Caillaud, C. &amp;amp; Thompson, M. W. (2011): Central and peripheral fatigue during passive and exercise-induced hyperthermia. Medicine and science in sports and exercise, 43 (9), 1657-1665. doi: 10.1249/MSS.0b013e3182148a9a.&lt;br /&gt;
* &lt;br /&gt;
* Périard, J. D., Caillaud, C. &amp;amp; Thompson, M. W. (2012): The role of aerobic fitness and exercise intensity on endurance performance in uncompensable heat stress conditions. European journal of applied physiology, 112 (6), 1989-1999. doi: 10.1007/s00421-011-2165-z.&lt;br /&gt;
* &lt;br /&gt;
* Périard, J. D., Cramer, M. N., Chapman, P. G., Caillaud, C. &amp;amp; Thompson, M. W. (2011): Cardiovascular strain impairs prolonged self-paced exercise in the heat. Experimental physiology, 96 (2), 134-144. doi: 10.1113/expphysiol.2010.054213.&lt;br /&gt;
* &lt;br /&gt;
* Périard, J. D., Cramer, M. N., Chapman, P. G., Caillaud, C. &amp;amp; Thompson, M. W. (2011): Neuromuscular function following prolonged intense self-paced exercise in hot climatic conditions. European journal of applied physiology, 111 (8), 1561-1569. doi: 10.1007/s00421-010-1781-3.&lt;br /&gt;
* &lt;br /&gt;
* Perrey, S., Grappe, F., Girard, A., Bringard, A., Groslambert, A., Bertucci, W. et al. (2003): Physiological and metabolic responses of triathletes to a simulated 30-min time-trial in cycling at self-selected intensity. International journal of sports medicine, 24 (2), 138-143. doi: 10.1055/s-2003-38200.&lt;br /&gt;
* &lt;br /&gt;
* Pinot, J. &amp;amp; Grappe, F. (2011): The record power profile to assess performance in elite cyclists. International journal of sports medicine, 32 (11), 839-844. doi: 10.1055/s-0031-1279773.&lt;br /&gt;
* &lt;br /&gt;
* Pottgiesser, T., Garvican, L. A., Martin, D. T., Featonby, J. M., Gore, C. J. &amp;amp; Schumacher, Y. O. (2012): Short-term hematological effects upon completion of a four-week simulated altitude camp. International journal of sports physiology and performance, 7 (1), 79-83.&lt;br /&gt;
* &lt;br /&gt;
* Quod, M. J., Martin, D. T., Martin, J. C. &amp;amp; Laursen, P. B. (2010): The Power Profile Predicts Road Cycling MMP. International journal of sports medicine, 31 (06), 397-401. doi: 10.1055/s-0030-1247528.&lt;br /&gt;
* &lt;br /&gt;
* Reiser, M., Meyer, T., Kindermann, W. &amp;amp; Daugs, R. (2000): Transferability of workload measurements between three different types of ergometer. European journal of applied physiology, 82 (3), 245-249. doi: 10.1007/s004210050678.&lt;br /&gt;
* &lt;br /&gt;
* Reiser, R. &amp;amp; Hart, C. (2008): Cycling on Rollers: Kreitler Fan Resistance at Submaximal Levels of Effort. International journal of sports medicine, 29 (3), 212-216. doi: 10.1055/s-2007-965002.&lt;br /&gt;
* &lt;br /&gt;
* Richalet, J.-P. &amp;amp; Gore, C. J. (2008): Live and/or sleep high:train low, using normobaric hypoxia. Scandinavian journal of medicine &amp;amp; science in sports, 18 Suppl 1, 29-37. doi: 10.1111/j.1600-0838.2008.00830.x.&lt;br /&gt;
* &lt;br /&gt;
* Roberts, A. D., Clark, S. A., Townsend, N. E., Anderson, M. E., Gore, C. J. &amp;amp; Hahn, A. G. (2003): Changes in performance, maximal oxygen uptake and maximal accumulated oxygen deficit after 5, 10 and 15 days of live high:train low altitude exposure. European journal of applied physiology, 88 (4-5), 390-395. doi: 10.1007/s00421-002-0720-3.&lt;br /&gt;
* &lt;br /&gt;
* Robertson, E. Y., Saunders, P. U., Pyne, D. B., Aughey, R. J., Anson, J. M. &amp;amp; Gore, C. J. (2010): Reproducibility of performance changes to simulated live high/train low altitude. Medicine and science in sports and exercise, 42 (2), 394-401. doi: 10.1249/MSS.0b013e3181b34b57.&lt;br /&gt;
* &lt;br /&gt;
* Robertson, E. Y., Saunders, P. U., Pyne, D. B., Gore, C. J. &amp;amp; Anson, J. M. (2010): Effectiveness of intermittent training in hypoxia combined with live high/train low. European journal of applied physiology, 110 (2), 379-387. doi: 10.1007/s00421-010-1516-5.&lt;br /&gt;
* &lt;br /&gt;
* Rodríguez, F. A., Truijens, M. J., Townsend, N. E., Stray-Gundersen, J., Gore, C. J. &amp;amp; Levine, B. D. (2007): Performance of runners and swimmers after four weeks of intermittent hypobaric hypoxic exposure plus sea level training. Journal of applied physiology (Bethesda, Md. : 1985), 103 (5), 1523-1535. doi: 10.1152/japplphysiol.01320.2006.&lt;br /&gt;
* &lt;br /&gt;
* Rylands, L. P., Roberts, S. J. &amp;amp; Hurst, H. T. (2015): Variability in Laboratory vs. Field Testing of Peak Power, Torque, and Time of Peak Power Production Among Elite Bicycle Motocross Cyclists. Journal of strength and conditioning research / National Strength &amp;amp; Conditioning Association, 29 (9), 2635-2640. doi: 10.1519/JSC.0000000000000884.&lt;br /&gt;
* &lt;br /&gt;
* Sassi, A., Rampinini, E., Martin, D. T. &amp;amp; Morelli, A. (2009): Effects of gradient and speed on freely chosen cadence: the key role of crank inertial load. Journal of biomechanics, 42 (2), 171-177. doi: 10.1016/j.jbiomech.2008.10.008.&lt;br /&gt;
* &lt;br /&gt;
* Saunders, P. U., Telford, R. D., Pyne, D. B., Cunningham, R. B., Gore, C. J., Hahn, A. G. et al. (2004): Improved running economy in elite runners after 20 days of simulated moderate-altitude exposure. Journal of applied physiology (Bethesda, Md. : 1985), 96 (3), 931-937. doi: 10.1152/japplphysiol.00725.2003.&lt;br /&gt;
* &lt;br /&gt;
* Saunders, P. U., Telford, R. D., Pyne, D. B., Hahn, A. G. &amp;amp; Gore, C. J. (2009): Improved running economy and increased hemoglobin mass in elite runners after extended moderate altitude exposure. Journal of science and medicine in sport / Sports Medicine Australia, 12 (1), 67-72. doi: 10.1016/j.jsams.2007.08.014.&lt;br /&gt;
* &lt;br /&gt;
* Saunders, P. U., Ahlgrim, C., Vallance, B., Green, D. J., Robertson, E. Y., Clark, S. A. et al. (2010): An attempt to quantify the placebo effect from a three-week simulated altitude training camp in elite race walkers. International journal of sports physiology and performance, 5 (4), 521-534.&lt;br /&gt;
* &lt;br /&gt;
* Saunders, P. U., Pyne, D. B. &amp;amp; Gore, C. J. (2009): Endurance training at altitude. High altitude medicine &amp;amp; biology, 10 (2), 135-148. doi: 10.1089/ham.2008.1092.&lt;br /&gt;
* &lt;br /&gt;
* Saunders, P. U., Telford, R. D., Pyne, D. D., Gore, C. J. &amp;amp; Hahn, A. G. (2009): Improved race performance in elite middle-distance runners after cumulative altitude exposure. International journal of sports physiology and performance, 4 (1), 134-138.&lt;br /&gt;
* &lt;br /&gt;
* Sharpe, K., Hopkins, W., Emslie, K. R., Howe, C., Trout, G. J., Kazlauskas, R. et al. (2002): Development of reference ranges in elite athletes for markers of altered erythropoiesis. Haematologica, 87 (12), 1248-1257.&lt;br /&gt;
* &lt;br /&gt;
* Simons, M., van Es, E. &amp;amp; Hendriksen, I. (2009): Electrically assisted cycling: a new mode for meeting physical activity guidelines? Medicine and science in sports and exercise, 41 (11), 2097-2102. doi: 10.1249/MSS.0b013e3181a6aaa4.&lt;br /&gt;
* &lt;br /&gt;
* Smith, M. F., Davison, R. C., Balmer, J. &amp;amp; Bird, S. R. (2001): Reliability of mean power recorded during indoor and outdoor self-paced 40 km cycling time-trials. International journal of sports medicine, 22 (4), 270-274. doi: 10.1055/s-2001-13813.&lt;br /&gt;
* &lt;br /&gt;
* Sparks, S. A., Dove, B., Bridge, C. A., Midgely, A. W. &amp;amp; McNaughton, L. R. (2014): Validity and Reliability of the Look Keo Power Pedal System for Measuring Power Output During Incremental and Repeated Sprint Cycling. International journal of sports physiology and performance. doi: 10.1123/ijspp.2013-0317.&lt;br /&gt;
* &lt;br /&gt;
* Stapelfeldt, B., Mornieux, G., Oberheim, R., Belli, A. &amp;amp; Gollhofer, A. (2007): Development and evaluation of a new bicycle instrument for measurements of pedal forces and power output in cycling. International journal of sports medicine, 28 (4), 326-332. doi: 10.1055/s-2006-924352.&lt;br /&gt;
* &lt;br /&gt;
* Stapelfeldt, B., Schwirtz, A., Schumacher, Y. O. &amp;amp; Hillebrecht, M. (2004): Workload demands in mountain bike racing. International journal of sports medicine, 25 (4), 294-300. doi: 10.1055/s-2004-819937.&lt;br /&gt;
* &lt;br /&gt;
* Tomas, A., Ross, E. Z. &amp;amp; Martin, J. C. (2010): Fatigue during maximal sprint cycling: unique role of cumulative contraction cycles. Medicine and science in sports and exercise, 42 (7), 1364-1369. doi: 10.1249/MSS.0b013e3181cae2ce.&lt;br /&gt;
* &lt;br /&gt;
* Townsend, N. E., Gore, C. J., Ebert, T. R., Martin, D. T., Hahn, A. G. &amp;amp; Chow, C.-M. (2016): Ventilatory acclimatisation is beneficial for high-intensity exercise at altitude in elite cyclists. European journal of sport science, 1-8. doi: 10.1080/17461391.2016.1139190.&lt;br /&gt;
* &lt;br /&gt;
* Townsend, N. E., Gore, C. J., Hahn, A. G., Aughey, R. J., Clark, S. A., Kinsman, T. A. et al. (2005): Hypoxic ventilatory response is correlated with increased submaximal exercise ventilation after live high, train low. European journal of applied physiology, 94 (1-2), 207-215. doi: 10.1007/s00421-004-1252-9.&lt;br /&gt;
* &lt;br /&gt;
* Townsend, N. E., Gore, C. J., Hahn, A. G., McKenna, M. J., Aughey, R. J., Clark, S. A. et al. (2002): Living high-training low increases hypoxic ventilatory response of well-trained endurance athletes. Journal of applied physiology (Bethesda, Md. : 1985), 93 (4), 1498-1505. doi: 10.1152/japplphysiol.00381.2002.&lt;br /&gt;
* &lt;br /&gt;
* Truijens, M. J., Rodríguez, F. A., Townsend, N. E., Stray-Gundersen, J., Gore, C. J. &amp;amp; Levine, B. D. (2008). The effect of intermittent hypobaric hypoxic exposure and sea level training on submaximal economy in well-trained swimmers and runners. Journal of applied physiology (Bethesda, Md. : 1985), 104 (2), 328-337. doi: 10.1152/japplphysiol.01324.2006.&lt;br /&gt;
* &lt;br /&gt;
* Vaile, J., Halson, S., Gill, N. &amp;amp; Dawson, B. (2008): Effect of Hydrotherapy on Recovery from Fatigue. International journal of sports medicine, 29 (7), 539-544. doi: 10.1055/s-2007-989267.&lt;br /&gt;
* &lt;br /&gt;
* van der Woude, L. H. V., Horstman, A., Faas, P., Mechielsen, S., Bafghi, H. A. &amp;amp; Koning, J. J. de. (2008): Power output and metabolic cost of synchronous and asynchronous submaximal and peak level hand cycling on a motor driven treadmill in able-bodied male subjects. Medical engineering &amp;amp; physics, 30 (5), 574-580. doi: 10.1016/j.medengphy.2007.06.006.&lt;br /&gt;
* &lt;br /&gt;
* Villerius, V., Duc, S. &amp;amp; Grappe, F. (2008): Physiological and Neuromuscular Responses of Competitive Cyclists during a Simulated Self-Paced Interval Training Session. International journal of sports medicine, 29 (09), 770-777. doi: 10.1055/s-2007-989317.&lt;br /&gt;
* &lt;br /&gt;
* Vogt, S., Roecker, K., Schumacher, Y. O., Pottgiesser, T., Dickhuth, H.-H., Schmid, A. et al. (2008): Cadence-power-relationship during decisive mountain ascents at the Tour de France. International journal of sports medicine, 29 (3), 244-250. doi: 10.1055/s-2007-965353.&lt;br /&gt;
* &lt;br /&gt;
* Vogt, S., Schumacher, Y. O., Roecker, K., Dickhuth, H.-H., Schoberer, U., Schmid, A. et al. (2007). Power Output during the Tour de France. International journal of sports medicine, 28 (9), 756-761. doi: 10.1055/s-2007-964982.&lt;br /&gt;
* &lt;br /&gt;
* Vogt, S., Heinrich, L., Schumacher, Y. O., Blum, A., Roecker, K., Dickhuth, H.-H. et al. (2006): Power output during stage racing in professional road cycling. Medicine and science in sports and exercise, 38 (1), 147-151.&lt;br /&gt;
* &lt;br /&gt;
* Vogt, S., Schumacher, Y. O., Blum, A., Roecker, K., Dickhuth, H.-H., Schmid, A. et al. (2007): Cycling power output produced during flat and mountain stages in the Giro d'Italia: a case study. Journal of sports sciences, 25 (12), 1299-1305. doi: 10.1080/02640410601001632.&lt;br /&gt;
* &lt;br /&gt;
* Wahl, P., Mathes, S., Köhler, K., Achtzehn, S., Bloch, W. &amp;amp; Mester, J. (2013): Acute Metabolic, Hormonal, and Psychological Responses to Different Endurance Training Protocols. Hormone and Metabolic Research, 45 (11), 827-833. doi: 10.1055/s-0033-1347242.&lt;br /&gt;
* &lt;br /&gt;
* Wahl, P., Schmidt, A., deMarees, M., Achtzehn, S., Bloch, W. &amp;amp; Mester, J. (2013): Responses of Angiogenic Growth Factors to Exercise, to Hypoxia and to Exercise under Hypoxic Conditions. International journal of sports medicine, 34 (02), 95-100. doi: 10.1055/s-0032-1314815.&lt;br /&gt;
* &lt;br /&gt;
* Wiedemann, M. S. F. &amp;amp; Bosquet, L. (2010): Anaerobic Work Capacity Derived from Isokinetic and Isoinertial Cycling. International journal of sports medicine, 31 (02), 89-94. doi: 10.1055/s-0029-1233466.&lt;br /&gt;
* &lt;br /&gt;
* Wilson, M. G., Lane, A. M., Beedie, C. J. &amp;amp; Farooq, A. (2012): Influence of accurate and inaccurate 'split-time' feedback upon 10-mile time trial cycling performance. European journal of applied physiology, 112 (1), 231-236. doi: 10.1007/s00421-011-1977-1.&lt;br /&gt;
* &lt;br /&gt;
* Wu, S. S. X., Peiffer, J. J., Brisswalter, J., Nosaka, K., Lau, W. Y. &amp;amp; Abbiss, C. R. (2015): Pacing strategies during the swim, cycle and run disciplines of sprint, Olympic and half-Ironman triathlons. European journal of applied physiology, 115 (5), 1147-1154. doi: 10.1007/s00421-014-3096-2.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
(In der folgenden Tabelle finden Sie aktuelle internationale Literaturstellen in denen das SRM - Ergometer und / oder die SRM - Trainingssysteme für wissenschaftliche Untersuchungen eingesetzt wurden.&lt;br /&gt;
[[Media:Scientific Publications SRM 2013.pdf|Hier]] finden sie die internationalen Literaturstellen in einem pfd - Dokument zusammengefasst.)&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot;&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|- class=&amp;quot;hintergrundfarbe6&amp;quot;&lt;br /&gt;
!style=&amp;quot;width:30%&amp;quot;| Autor!! style=&amp;quot;width:30%&amp;quot; | Titel!! style=&amp;quot;width:30%&amp;quot; | Publikation&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Abbiss, C.R.; Quod, M.J.; Martin, David T.; Netto, K.J.; Nosaka, K.; Lee, H. et al. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Dynamic pacing strategies during the cycle phase of an Ironman triathlon.  &lt;br /&gt;
|style=&amp;quot;vertical-align:top&amp;quot;| Med Sci Sports Exerc 38 (4), S. 726–734&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Abbiss, C.R.; Quod, M.J.; Levin, G.; Martin, D.T.; Laursen, P.B. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Accuracy of the Velotron ergometer and SRM power meter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 30 (2), S. 107–112.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Abel, T.; Burkett, B.; Schneider, S.; Lindschulten, R.; Strüder, H. K. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The exercise profile of an ultra-long handcycling race: the Styrkeprøven experience.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Spinal Cord 48 (12), S. 894–898.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Antonutto, G.; Capelli, C.; Girardis, M.; Zamparo, P.; di Prampero P.E. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of microgravity on maximal power of lower limbs during very short efforts in humans.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Physiol 86(1), S. 85-92.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Arkesteijn, M.; Hopker, J.; Jobson, S.; Passfield, L. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The Effect of Turbo Trainer Cycling on Pedalling Technique and Cycling Efficiency.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 34 (06), S. 520–525&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M. J.; Gore, C. J.; Burge, C. M.; Clough, M. L.; Bourdon, P. C.; Dobson, G. P.; Hahn, A. G. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Skin-prick blood samples are reliable for estimating Hb mass with the CO-dilution technique.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 79 (6), S. 535–537.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M. J.; Gore, C. J.; Dobson, G. P.; Boston, T. T.; Parisotto, R.; Emslie, K. R. et al. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Simulated moderate altitude elevates serum erythropoietin but does not increase reticulocyte production in well-trained runners.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 81 (5), S. 428–435&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Gore, C. J.; Dobson, G. P.; Hahn, A. G. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| &amp;quot;Live high, train low&amp;quot; does not change the total haemoglobin mass of male endurance athletes sleeping at a simulated altitude of 3000 m for 23 nights. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 80 (5), S. 479–484.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Gore, C. J.; Martin, D. T.; Dobson, G. P.; Hahn, A. G. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of a 12-day &amp;quot;live high, train low&amp;quot; camp on reticulocyte production and haemoglobin mass in elite female road cyclists.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 80 (5), S. 472–478.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Hahn, A. G.; Martin, D. T.; Logan, P.; Parisotto, R.; Gore, C. J. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| A comparison of the physiological response to simulated altitude exposure and r-HuEpo administration.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 19 (11), S. 831–837&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Gore, C.J.; Parisotto, R.; Sharpe, K.; Hopkins, W.G.; Hahn, A.G. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effect of altitude on second-generation blood tests to detect erythropoietin abuse by athletes.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Haematologica 88 (9), S. 1053–1062&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Aughey, R. J.; Clark, S. A.; Gore, C. J.; Townsend, N. E.; Hahn, A. G.; Kinsman, T. A. et al. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Interspersed normoxia during live high, train low interventions reverses an early reduction in muscle Na+, K +ATPase activity in well-trained athletes.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 98 (3), S. 299–309&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Aughey, R. J.; Gore, C. J.; Hahn, A. G.; Garnham, A. P.; Clark, S. A.; Petersen, A. C. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Chronic intermittent hypoxia and incremental cycling exercise independently depress muscle in vitro maximal Na+-K+-ATPase activity in well-trained athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 98 (1), S. 186–192&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashman, S.B.; Monk, T.H.; Kupfer, D.J.; Clark, C.H.; Myers, F.S.; Frank, E.; Leibenluft (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Relationship between social rhythms and mood in patients with rapid cycling bipolar disorder.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Psychiatry Res 86 (1), S. 1–8&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Austin, N.; Nilwik, R.; Herzog, W. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| In vivo operational fascicle lengths of vastus lateralis during submaximal and maximal cycling.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Biomech 43 (12), S. 2394–2399&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Balmer, J.; Bird, S.; Davison, R.C.R.; Doherty, M.; Smith, P. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Mechanically braked Wingate powers: agreement between SRM, corrected and conventional methods of measurement.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 22 (7), S. 661–667&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Bird, S.; Davison, R.; Lucia, A. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effect of age on 16.1-km time-trial performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 26 (2), S. 197–206&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Davison, R.C.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Peak power predicts performance power during an outdoor 16.1-km cycling time trial.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 32 (8), S. 1485–1490&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Balmer, J.; Davison, R.C.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reliability of an air-braked ergometer to record peak power during a maximal cycling test.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 32 (10), S. 1790–1793&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Davison, R.C.; Coleman, D.A.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The validity of power output recorded during exercise performance tests using a Kingcycle air-braked cycle ergometer when compared with an SRM powermeter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 21 (3), S. 195–199&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bassett, D.R.; Kyle, C. R.; Passfield, L.; Broker, J.P.; Burke, E.R. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Comparing cycling world hour records, 1967-1996: modeling with empirical data.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 31 (11), S. 1665–1676&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bentley, D. J.; McNaughton, L. R.; Thompson, D.; Vleck, V. E.; Batterham, A. M. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Peak power output, the lactate threshold, and time trial performance in cyclists. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 33 (12), S. 2077–2081&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Crequy, S.; Chiementin, X. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and Reliability of the G-Cog BMX Powermeter.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Bertucci, W.; Duc, S.; Villerius, V.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of the Axiom PowerTrain cycle ergometer when compared with an SRM powermeter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (1), S. 59–65&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Duc, S.; Villerius, V.; Pernin, J. N.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and reliability of the PowerTap mobile cycling powermeter when compared with the SRM Device.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (10), S. 868–873&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Grappe, F.; Girard, A.; Betik, A.; Rouillon, J.D. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects on the crank torque profile when changing pedalling cadence in level ground and uphill road cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Biomech 38 (5), S. 1003–1010&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Grappe, F.; Groslambert, A. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Laboratory versus outdoor cycling conditions: differences in pedaling biomechanics. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Biomech 23 (2), S. 87–92&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Taiar, R.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Differences between sprint tests under laboratory and actual cycling conditions. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Med Phys Fitness 45 (3), S. 277–283&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Billaut, François; Gore, Christopher J.; Aughey, Robert J. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Enhancing team-sport athlete performance: is altitude training relevant?&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 42 (9), S. 751–767&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Brickley, G.; Dekerle, J.; Hammond, A.; Pringle, J.; Carter, H. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Assessment of Maximal Aerobic Power and Critical Power in a Single 90-s Isokinetic All-Out Cycling Test.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 28 (5), S. 414–419&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Broker, J.P.; Kyle, C.R.; Burke, E.R. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Racing cyclist power requirements in the 4000-m individual and team pursuits.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 31 (11), S. 1677–1685&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Brosnan, M. J.; Martin, D. T.; Hahn, A. G.; Gore, C. J.; Hawley, J. A. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Impaired interval exercise responses in elite female cyclists at moderate simulated altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 89 (5), S. 1819–1824&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Cangley, P.; Passfield, L.; Carter, H.; Bailey, M. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The Effect of Variable Gradients on Pacing in Cycling Time-Trials.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 32 (02), S. 132–136&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Carpes, F.P.; Rossato, M.; Faria, I.E.; Bolli Mota, C. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Bilateral pedaling asymmetry during a simulated 40-km cycling timetrial.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Med Phys Fitness 47 (1), S. 51–57&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Clark, Sally A.; Bourdon, P. C.; Schmidt, W.; Singh, B.; Cable, G.; Onus, K. J. et al. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The effect of acute simulated moderate altitude on power, performance and pacing strategies in well-trained cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 102 (1), S. 45–55&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Clark, Sally A.; Quod, M. J.; Clark, M. A.; Martin, D. T.; Saunders, P. U.; Gore, C. J. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Time course of haemoglobin mass during 21 days live high:train low simulated altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 106 (3), S. 399–406&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Clark, S.K.; Johnson, Thomas M. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Selenium stable isotope investigation into selenium biogeochemical cycling in a lacustrine environment: Sweitzer Lake, Colorado.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Environ. Qual. 39 (6), S. 2200–2210&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Coleman, D.A.; Wiles, J.D.; Nunn, M.; Smith, M.F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reliability of sprint test indices in well-trained cyclists. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (5), S. 383–387&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Doherty, M.; Balmer, J.; Davison, R.C.R.; Robinson, L.; Smith, P.M. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reliability of a combined 3-min constant load and performance cycling test.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 24 (5), S. 366–371&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Duc, S.; Betik, A-C; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| EMG activity does not change during a time trial in competitive cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (2), S. 145–150&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Duc, S.; Villerius, V.; Bertucci, W.; Pernin, J.N.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Muscular activity level during pedalling is not affected by crank inertial load.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 95 (2-3), S. 260–264&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Duc, S.; Villerius, V.; Bertucci, W.; Grappe, F. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and reproducibility of the ErgomoPro power meter compared with the SRM and Powertap power meters.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 2 (3), S. 270–281&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Eastwood, A.; Sharpe, K.; Bourdon, P.C.; Woolford, S.M.; Saunders, P.U.; Robertson, E.Y. et al. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Within-subject variation in hemoglobin mass in elite athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 44 (4), S. 725–732&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Ebert, T.R.; Martin, D.T.; McDonald, W.; Victor, J.; Plummer, J.; Withers, R.T. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Power output during women's World Cup road cycle racing.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 95 (5-6), S. 529–536&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ebert, T.R.; Martin, D.T.; Stephens, B.; Withers, R.T. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Power output during a professional men's road-cycling tour.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 1 (4), S. 324–335&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Emonson, D. L.; Aminuddin, A. H.; Wight, R. L.; Scroop, G. C.; Gore, C. J. (1997)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Training-induced increases in sea level VO2max and endurance are not enhanced by acute hypobaric exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 76 (1), S. 8–12&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Faiss, R.; Praz, M.; Meichtry, A.; Gobelet, C.; Deriaz, O. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The effect of mountain bike suspensions on vibrations and off-road uphill performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Med Phys Fitness 47 (2), S. 151–158&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Fu, Qi; Townsend, N.E.; Shiller, S.M.; Martini, E.R.; Okazaki, K.; Shibata, S. et al. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Intermittent hypobaric hypoxia exposure does not cause sustained alterations in autonomic control of blood pressure in young athletes. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Am. J. Physiol. Regul. Integr. Comp. Physiol. 292 (5), S. R1977-84&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gardner, A.S.; Martin, J.C.; Martin, D.T.; Barras, M.; Jenkins, D.G. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Maximal torque- and power-pedaling rate relationships for elite sprint cyclists in laboratory and field tests. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 101 (3), S. 287–292&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gardner, A.S.; Martin, D.T.; Jenkins, D.G.; Dyer, I.; van Eiden, J.; Barras, M.; Martinm, J.C. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Velocity-specific fatigue: quantifying fatigue during variable velocity cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Med Sci Sports Exerc 41 (4), S. 904–911&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gardner, A.S.; Stephens, S.; Martin, D.T.; Lawton, E.; Lee, H.; Jenkins, D. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Accuracy of SRM and power tap power monitoring systems for bicycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 36 (7), S. 1252–1258&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Garvican, L.A.; Hammond, K.; Varley, Matthew C.; Gore, C.J.; Billaut, F.; Aughey, R.J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Lower Running Performance and Exacerbated Fatigue in Soccer Played at 1600 m. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Garvican, L.A.; Martin, D.T.; Clark, S.A.; Schmidt, W.F.; Gore, C.J. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Variability of erythropoietin response to sleeping at simulated altitude: a cycling case study. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 2 (3), S. 327–331.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Garvican, L.A.; Pottgiesser, T.; Martin, D.T.; Schumacher, Y.O.; Barras, M.; Gore, C.J. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The contribution of haemoglobin mass to increases in cycling performance induced by simulated LHTL. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 111 (6), S. 1089–1101&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Garvican, L.A.; Saunders, P.U.; Pyne, D.B.; Martin, D.T.; Robertson, E.Y.; Gore, C.J. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Hemoglobin mass response to simulated hypoxia &amp;quot;blinded&amp;quot; by noisy measurement? &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 112 (10), S. 1797-8; author reply 1799&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Giacomoni, M.; Billaut, F.; Falgairette, G. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effects of the Time of Day on Repeated All-Out Cycle Performance and Short-Term Recovery Patterns. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 27 (6), S. 468–474&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| González-Haro, C.; Galilea B., P.A.; Soria, M.; Drobnic, F.; Escanero, J.F. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Comparison of nine theoretical models for estimating the mechanical power output in cycling. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Br J Sports Med 41 (8), S. 506-9; discussion 509&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| González-Haro, C.; Galilea, P.A.; Escanero, J.F. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Comparison of different theoretical models estimating peak power output and maximal oxygen uptake in trained and elite triathletes and endurance cyclists in the velodrome. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Sci 26 (6), S. 591–601&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Goosey-Tolfrey, V.; Castle, P.; Webborn, N.; Abel, T. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Aerobic capacity and peak power output of elite quadriplegic games players.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Br J Sports Med 40 (8), S. 684–687&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gordon, R.S.; Franklin, K.L.; Davies, B.; Baker, J.S. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Further mechanical considerations between polar and SRM mobile ergometer systems during laboratory-based high-intensity, intermittent cycling activity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Res Sports Med 15 (4), S. 241–247&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, Christopher John; Clark, Sally A.; Saunders, Philo U. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Nonhematological mechanisms of improved sea-level performance after hypoxic exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 39 (9), S. 1600–1609&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A. G.; Aughey, R. J.; Martin, D. T.; Ashenden, M. J.; Clark, S. A. et al. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Live high:train low increases muscle buffer capacity and submaximal cycling efficiency.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Acta Physiol. Scand. 173 (3), S. 275–286&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A. G.; Burge, C. M.; Telford, R. D. (1997)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| VO2max and haemoglobin mass of trained athletes during high intensity training.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 18 (6), S. 477–482&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore C.J.; Hahn A.G.; Scroop G.C.; Watson D.B.; Norton K.I.; Wood R.J.; Campbell D.P. (1996 )&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Increased arterial desaturation in trained cyclists during maximal exercise at 580 m altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Physiol 80(6), S. 2204-10&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A.; Rice, A.; Bourdon, P.; Lawrence, S.; Walsh, C. et al. (1998)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Altitude training at 2690m does not increase total haemoglobin mass or sea level VO2max in world champion track cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 1 (3), S. 156–170&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A. G. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Letter to the editors - Re: Heinicke K, Heinicke I, Schmidt W, Wolfarth B. A three-week traditional altitude training increases hemoglobin mass and red cell volume in elite biathlon athletes. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (6), S. 504-5; author reply 506-7&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore C.J.; Little S.C.; Hahn A.G.; Scroop G.C.; Norton K.I.; Bourdon P.C.; Woolford (1997)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reduced performance of male and female athletes at 580 m altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 75(2), S. 136-43&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; McSharry, P. E.; Hewitt, A. J.; Saunders, P. U. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Preparation for football competition at moderate to high altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Scand J Med Sci Sports 18 Suppl 1, S. 85–95&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, Christopher J.; Rodríguez, Ferran A.; Truijens, Martin J.; Townsend, Nathan E.; Stray-Gundersen, James; Levine, Benjamin D. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Increased serum erythropoietin but not red cell production after 4 wk of intermittent hypobaric hypoxia (4,000-5,500 m).&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 101 (5), S. 1386–1393&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gough, C. E.; Sharpe, K.; Garvican, L. A.; Anson, J. M.; Saunders, P. U.; Gore, C. J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The effects of injury and illness on haemoglobin mass.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 34 (9), S. 763–769&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gough, C.E.; Saunders, P.U.; Fowlie, J.; Savage, B.; Pyne, D.B.; Anson, J.M. et al. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Influence of altitude training modality on performance and total haemoglobin mass in elite swimmers.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 112 (9), S. 3275–3285&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Groslambert, A.; Grappe, F.; Bertucci, W.; Perrey, S.; Girard, A.J.; Rouillon, J.D. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| A perceptive individual time trial performed by triathletes to estimate the anaerobic threshold. A preliminary study.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Med Phys Fitness 44 (2), S. 147–156&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Haakonssen, Eric C.; Martin, David T.; Burke, Louise M.; Jenkins, David G. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Energy expenditure of constant- and variable-intensity cycling: power meter estimates. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 45 (9), S. 1833–1840&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hahn, A. G.; Gore, C. J. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The effect of altitude on cycling performance: a challenge to traditional concepts. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 31 (7), S. 533–557&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hahn, A. G.; Gore, C. J.; Martin, D. T.; Ashenden, M. J.; Roberts, A. D.; Logan, P. A. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Hahn, A. G.; Gore, C. J.; Martin, D. T.; Ashenden, M. J.; Roberts, A. D.; Logan, P. A. (2001) &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Comp. Biochem. Physiol., Part A Mol. Integr. Physiol. 128 (4), S. 777–789&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hajoglou, A.; Foster, C.; Koning, J.J. de; Lucia, A.; Kernozek, T.W.; Porcari, J.P. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effect of warm-up on cycle time trial performance. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 37 (9), S. 1608–1614&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Hopker, J.; Myers, S.; Jobson, S.A.; Bruce, W.; Passfield, L. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of the Wattbike cycle ergometer&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 31 (10), S. 731–736&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Hurst, H.T.; Atkins, S. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Agreement between polar and SRM mobile ergometer systems during laboratory-based high-intensity, intermittent cycling activity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 24 (8), S. 863–868&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hurst, H.T.; Atkins, S. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Power output of field-based downhill mountain biking.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 24 (10), S. 1047–1053&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Davison, R.C.; Coleman, D.A.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The validity of power output recorded during exercise performance tests using a Kingcycle air-braked cycle ergometer when compared with an SRM powermeter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 21 (3), S. 195–199&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Jobson, S.A.; Passfield, L.; Atkinson, G.; Barton, G.; Scarf, P. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The analysis and utilization of cycling training data.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 39 (10), S. 833–844&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Jobson, S.; Woodside, J.; Passfield, L.; Nevill, A. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Allometric Scaling of Uphill Cycling Performance. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (09), S. 753–757&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Joch, W.; Ückert, S. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of Whole Body Cooling of - 110 °C on the Heart Frequency in Endurance Activity and in Resting Time. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| W. Phys Rehab Kur Med  14(3), S. 146-150&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Julian, Colleen G.; Gore, Christopher J.; Wilber, Randall L.; Daniels, Jack T.; Fredericson, Michael; Stray-Gundersen, James et al. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Intermittent normobaric hypoxia does not alter performance or erythropoietic markers in highly trained distance runners.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 96 (5), S. 1800–1807&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Karsten, B.; Jobson, S.A.; Hopker, J.; Passfield, L., Beedie, C. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The 3-min Test Does not Provide a Valid Measure of Critical Power Using the SRM Isokinetic Mode.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med. Sep 10. [Epub ahead of print]&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, T. A.; Gore, C. J.; Hahn, A. G.; Hopkins, W. G.; Hawley, J. A.; McKenna, M. J. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sleep in athletes undertaking protocols of exposure to nocturnal simulated altitude at 2650 m.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 8 (2), S. 222–232&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, T. A.; Hahn, A. G.; Gore, C. J.; Martin, D. T.; Chow, C. M. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sleep quality responses to atmospheric variation: case studies of two elite female cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 6 (4), S. 436–442&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, Tahnee A.; Hahn, Allan G.; Gore, Christopher J.; Wilsmore, Bradley R.; Martin, David T.; Chow, Chin-Moi (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Respiratory events and periodic breathing in cyclists sleeping at 2,650-m simulated altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 92 (5), S. 2114–2118&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, Tahnee A.; Townsend, Nathan E.; Gore, Christopher J.; Hahn, Allan G.; Clark, Sally A.; Aughey, Robert J. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sleep disturbance at simulated altitude indicated by stratified respiratory disturbance index but not hypoxic ventilatory response.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 94 (5-6), S. 569–575&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kirkland, A.; Coleman, D.; Wiles, J.D.; Hopker, J. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of the Ergomopro powermeter.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (11), S. 913–916&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Loughlin, A.F.; Skiles, G.L.; Alberts, D.W.; Schaefer, W.H. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| An ion exchange liquid chromatography/mass spectrometry method for the determination of reduced and oxidized glutathione and glutathione conjugates in hepatocytes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Pharm Biomed Anal 26 (1), S. 131–142&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|MacIntosh, B.R.; Svedahl, K.; Kim, M. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Fatigue and optimal conditions for short-term work capacity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 92 (4-5), S. 369–375&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|MacRae HS-H; Hise, K.J.; Allen, P.J. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of front and dual suspension mountain bike systems on uphill cycling performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 32 (7), S. 1276–1280&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Mc Naughton, L.R.; Sherman, R.; Roberts, S.; Bentley, D.J. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Portable gas analyser Cosmed K4b2 compared to a laboratory based mass spectrometer system.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Med Phys Fitness 45 (3), S. 315–323&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| McDaniel, J.; Subudhi, A.; Martin, J.C. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Torso stabilization reduces the metabolic cost of producing cycling power.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Can J Appl Physiol 30 (4), S. 433–441&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|McLean, Blake D.; Buttifant, David; Gore, Christopher J.; White, Kevin; Liess, Carsten; Kemp, Justin (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Physiological and performance responses to a preseason altitude-training camp in elite team-sport athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 8 (4), S. 391–399&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Meyer, T.; Gabriel, H.H.W.; Auracher, M.; Scharhag, J.; Kindermann, W. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Metabolic profile of 4 h cycling in the field with varying amounts of carbohydrate supply.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 88 (4-5), S. 431–437&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Mijnarends, D.M.; Meijers, J.M.M.; Halfens, R.J.G.; Ter Borg, S.; Luiking, Y.C.; Verlaan, S. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of tools to measure muscle mass, strength, and physical performance in community-dwelling older people: a systematic review.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Am Med Dir Assoc 14 (3), S. 170–178&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Millet, G.P.; Tronche, C.; Fuster, N.; Candau, R. (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Level ground and uphill cycling efficiency in seated and standing positions.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Med Sci Sports Exerc 34 (10), S. 1645–1652&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Millet, G.P.; Tronche, C.; Fuster, N.; Bentley, D.J.; Candau, R. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and reliability of the Polar S710 mobile cycling powermeter.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 24 (3), S. 156–161&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Mornieux, G.; Gollhofer, A.; Stapelfeldt, B. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Muscle Coordination while Pulling up During Cycling. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 31 (12), S. 843–846&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Mornieux, G.; Stapelfeldt, B.; Gollhofer, A.; Belli, A. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effects of Pedal Type and Pull-Up Action during Cycling. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (10), S. 817–822&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Neville, V.; Pain, M.T.G.; Folland, J.P. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Aerobic power and peak power of elite America's Cup sailors. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 106 (1), S. 149–157&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Neville, V.; Pain, M.T.G.; Kantor, J.; Folland, J.P. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Influence of crank length and crank-axle height on standing armcrank (grinding) power.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 42 (2), S. 381–387&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Neville, V.; Zaher, N.; Pain, M.T.G.; Folland, J.P. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Lower limb influence on standing arm-cranking ('grinding').&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 30 (10), S. 713–718&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Neya, Mitsuo; Enoki, Taisuke; Ohiwa, Nao; Kawahara, Takashi; Gore, Christopher J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Increased hemoglobin mass and VO2max with 10 h nightly simulated altitude at 3000 m.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 8 (4), S. 366–372&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Nimmerichter, A.; Eston, R.G.; Bachl, N.; Williams, C. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Longitudinal monitoring of power output and heart rate profiles in elite cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 29 (8), S. 831–840&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Nimmerichter, A.; Williams, C.; Bachl, N.; Eston, R. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Evaluation of a field test to assess performance in elite cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 31 (3), S. 160–166&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|O’Hara, J.; Thomas, A.; Seims, A.; Cooke, C.; King, R.F.G (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reliability of a High-Intensity Endurance Cycling Test.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 33 (01), S. 18–25&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Parisotto, R.; Gore, C. J.; Hahn, A. G.; Ashenden, M. J.; Olds, T. S.; Martin, D. T. et al. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reticulocyte parameters as potential discriminators of recombinant human erythropoietin abuse in elite athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 21 (7), S. 471–479&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Paton, C.D.; Hopkins, W.G. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Tests of cycling performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 31 (7), S. 489–496&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Paton, C.D.; Hopkins, W.G. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Ergometer error and biological variation in power output in a performance test with three cycle ergometers.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 27 (6), S. 444–447&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Caillaud, C.; Thompson, M.W. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Central and Peripheral Fatigue during Passive and Exercise-Induced Hyperthermia &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med. Sci. Sports Exerc. 43 (9), S. 1657 – 1665&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Caillaud, C.; Thompson, M.W. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The role of aerobic fitness and exercise intensity on endurance performance in uncompensable heat stress conditions. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol  112, S. 1989 - 1999&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Cramer, M.N.; Chapman, P.G.; Caillaud, C.; Thompson, M.W. (2011)  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Cardiovascular strain impairs prolonged self-paced exercise in the heat. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Exp Physiol 96 (2), S. 134 - 144&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Cramer, M.N.; Chapman, P.G.; Caillaud, C.; Thompson, M.W. (2011)   &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Neuromuscular function following prolonged intense self-paced exercise in hot climatic conditions. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Physiol. 111, S. 1561 – 1569&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Perrey, S.; Grappe, F.; Girard, A.; Bringard, A.; Groslambert, A.; Bertucci, W.; Rouillon, J.D. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Physiological and metabolic responses of triathletes to a simulated 30-min time-trial in cycling at self-selected intensity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 24 (2), S. 138–143&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Pester, M.; Knorr, K.-H.; Friedrich, M.W.; Wagner, M.; Loy, A. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sulfate-reducing microorganisms in wetlands - fameless actors in carbon cycling and climate change.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Front Microbiol 3, S. 72&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Pinot, J.; Grappe, F. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The record power profile to assess performance in elite cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 32 (11), S. 839–844&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Pottgiesser, Torben; Garvican, Laura A.; Martin, David T.; Featonby, Jesse M.; Gore, Christopher J.; Schumacher, Yorck O. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Short-term hematological effects upon completion of a four-week simulated altitude camp.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Physiol Perform 7 (1), S. 79–83&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Quod, M. J.; Martin, D. T.; Martin, J. C.; Laursen, P. B. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The Power Profile Predicts Road Cycling MMP.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 31 (06), S. 397–401&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Reiser, M.; Meyer, T.; Kindermann, W.; Daugs, R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Transferability of workload measurements between three different types of ergometer.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 82 (3), S. 245–249&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Reiser, R.; Hart, C. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Cycling on Rollers: Kreitler Fan Resistance at Submaximal Levels of Effort.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (3), S. 212–216&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Richalet, J-P; Gore, C. J. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Live and/or sleep high:train low, using normobaric hypoxia.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Scand J Med Sci Sports 18 Suppl 1, S. 29–37&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Roberts, A. D.; Clark, S. A.; Townsend, N. E.; Anderson, M. E.; Gore, C. J.; Hahn, A. G. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Changes in performance, maximal oxygen uptake and maximal accumulated oxygen deficit after 5, 10 and 15 days of live high:train low altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 88 (4-5), S. 390–395&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Robertson, E.Y.; Saunders, P.U.; Pyne, D.B.; Aughey, R.J.; Anson, J.M.; Gore, C.J. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reproducibility of performance changes to simulated live high/train low altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 42 (2), S. 394–401&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Robertson, E.Y.; Saunders, P.U.; Pyne, D.B.; Gore, C.J.; Anson, J.M. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effectiveness of intermittent training in hypoxia combined with live high/train low.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| . J. Appl. Physiol. 110 (2), S. 379–387&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Rodríguez, F.A.; Truijens, M.J.; Townsend, N.E.; Stray-Gundersen, J.; Gore, C.J.; Levine, B.D. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Performance of runners and swimmers after four weeks of intermittent hypobaric hypoxic exposure plus sea level training.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 103 (5), S. 1523–1535&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Sassi, A.; Rampinini, E.; Martin, D.T.; Morelli, A. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of gradient and speed on freely chosen cadence: the key role of crank inertial load.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Biomech 42 (2), S. 171–177&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P. U.; Telford, R. D.; Pyne, D. B.; Cunningham, R. B.; Gore, C. J.; Hahn, A. G.; Hawley, J. A. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Improved running economy in elite runners after 20 days of simulated moderate-altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 96 (3), S. 931–937&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P. U.; Telford, R. D.; Pyne, D. B.; Hahn, A. G.; Gore, C. J. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Improved running economy and increased hemoglobin mass in elite runners after extended moderate altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 12 (1), S. 67–72&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P.U.; Ahlgrim, C.; Vallance, B.; Green, D.J.; Robertson, E.Y.; Clark, S.A. et al. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| An attempt to quantify the placebo effect from a three-week simulated altitude training camp in elite race walkers.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 5 (4), S. 521–534&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P.U.; Pyne, David B.; Gore, C.J. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Endurance training at altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| High Alt. Med. Biol. 10 (2), S. 135–148&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P.U.; Telford, R.D.; Pyne, D.D.; Gore, C.J.; Hahn, A.G. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Improved race performance in elite middle-distance runners after cumulative altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 4 (1), S. 134–138&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Sharpe, K.; Hopkins, W.; Emslie, K.R.; Howe, C.; Trout, G.J.; Kazlauskas, R. et al. (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Development of reference ranges in elite athletes for markers of altered erythropoiesis.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Haematologica 87 (12), S. 1248–1257&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Simons, M.; van Es, E.; Hendriksen, I. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Electrically assisted cycling: a new mode for meeting physical activity guidelines?&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 41 (11), S. 2097–2102&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Smith, M.F.; Davison, R.C.; Balmer, J.; Bird, S.R. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reliability of mean power recorded during indoor and outdoor selfpaced 40 km cycling time-trials.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 22 (4), S. 270–274&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Stapelfeldt, B.; Mornieux, G.; Oberheim, R.; Belli, A.; Gollhofer, A. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Development and evaluation of a new bicycle instrument for measurements of pedal forces and power output in cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 28 (4), S. 326–332&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Stapelfeldt, B.; Schwirtz, A.; Schumacher, Y.O.; Hillebrecht, M. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Workload demands in mountain bike racing.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 25 (4), S. 294–300&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Tomas, A.; Ross, E.Z.; Martin, J.C. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Fatigue during maximal sprint cycling: unique role of cumulative contraction cycles.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 42 (7), S. 1364–1369&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Townsend, N.E.; Gore, C.J.; Hahn, A.G.; Aughey, R.J.; Clark, S.A.; Kinsman, T.A. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Hypoxic ventilatory response is correlated with increased submaximal exercise ventilation after live high, train low.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 94 (1-2), S. 207–215&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Townsend, N.E.; Gore, C.J.; Hahn, A.G.; McKenna, M.J.; Aughey, R.J.; Clark, S.A. et al. (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Living high-training low increases hypoxic ventilatory response of well-trained endurance athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 93 (4), S. 1498–1505&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Truijens, M.J.; Rodríguez, F.A.; Townsend, N.E.; Stray-Gundersen, J.; Gore, C.J.; Levine, B.D. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The effect of intermittent hypobaric hypoxic exposure and sea level training on submaximal economy in well-trained swimmers and runners.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 104 (2), S. 328–337&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Vaile, J.; Halson, S.; Gill, N.; Dawson, B. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effect of Hydrotherapy on Recovery from Fatigue.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 29 (7), S. 539–544&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| van der Woude, L.H.V.; Horstman, A.; Faas, P.; Mechielsen, S.; Bafghi, H.A.; Koning, J.J. de (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Power output and metabolic cost of synchronous and asynchronous submaximal and peak level hand cycling on a motor driven treadmill in able-bodied male subjects.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Med Eng Phys 30 (5), S. 574–580&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Villerius, V.; Duc, S.; Grappe, F. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Physiological and Neuromuscular Responses of Competitive Cyclists during a Simulated Self-Paced Interval Training Session.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (09), S. 770–777&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Vogt, S.; Heinrich, L.; Schumacher, Y. O.; Blum, A.; Roecker, K.; Dickhuth, H.-H.; Schmid, A. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Power output during stage racing in professional road cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 38 (1), S. 147–151&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Vogt, S.; Roecker, K.; Schumacher, Y. O.; Pottgiesser, T.; Dickhuth, H-H; Schmid, A.; Heinrich, L. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Cadence-power-relationship during decisive mountain ascents at the Tour de France.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 29 (3), S. 244–250&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Vogt, S.; Schumacher, Y.O.; Blum, A.; Roecker, K.; Dickhuth, H.-H.; Schmid, A.; Heinrich, L. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Cycling power output produced during flat and mountain stages in the Giro d'Italia: a case study.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Sci 25 (12), S. 1299–1305&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Vogt, S.; Schumacher, Y. O.; Roecker, K.; Dickhuth, H-H; Schoberer, U.; Schmid, A.; Heinrich, L. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Power Output during the Tour de France.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 28 (9), S. 756–761&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wahl, P.; Mathes, S.; Köhler, K.; Achtzehn, S.; Bloch, W.; Mester, J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Acute Metabolic, Hormonal, and Psychological Responses to Different Endurance Training Protocols.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Horm Metab Res 45 (11), S. 827–833&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wahl, P.; Schmidt, A.; deMarees, M.; Achtzehn, S.; Bloch, W.; Mester, J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Responses of Angiogenic Growth Factors to Exercise, to Hypoxia and to Exercise under Hypoxic Conditions.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 34 (02), S. 95–100&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wiedemann, M. S. F.; Bosquet, L. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Anaerobic Work Capacity Derived from Isokinetic and Isoinertial Cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 31 (02), S. 89–94&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wilson, M.G.; Lane, A.M.; Beedie, C.J.; Farooq, A. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Influence of accurate and inaccurate 'split-time' feedback upon 10-mile time trial cycling performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 112 (1), S. 231–236&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wooles, A.L.; Robinson, A.J.; Keen, P.S. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|A Static Method for Obtaining a Calibration Factor for SRM Bicycle Power Cranks.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sports Engineering 8 (3), S. 137-144&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Internationale_Literatur_zum_SRM-Ergometer&amp;diff=2012</id>
		<title>Internationale Literatur zum SRM-Ergometer</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Internationale_Literatur_zum_SRM-Ergometer&amp;diff=2012"/>
				<updated>2016-06-29T08:38:28Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{languages&lt;br /&gt;
|de=Internationale Literatur zum SRM-Ergometer&lt;br /&gt;
|en=International publications on the SRM Ergometer&lt;br /&gt;
|cn=International publications on the SRM Ergometer&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
In der folgenden Tabelle sind  diverese Sammlungen an Publikationen zu verschiedenen Themen als PDF-Dateien verlinkt.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot;&lt;br /&gt;
|+ style=&amp;quot;padding-bottom:1em&amp;quot; | Publikationen des SRM-Ergometers &lt;br /&gt;
|- class=&amp;quot;hintergrundfarbe6&amp;quot;&lt;br /&gt;
!style=&amp;quot;width:60%&amp;quot;| Publikationen!! style=&amp;quot;width:30%&amp;quot;| Letztes Update&lt;br /&gt;
|-&lt;br /&gt;
| [[Media:SRM_Scientific_Publications_06-2016.pdf|SRM Scientific Publications]]&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| Juni 2016 &lt;br /&gt;
|-&lt;br /&gt;
| [[Media:Torque_publications_2015.pdf|Torque Publications]]&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| Januar 2015&lt;br /&gt;
|-&lt;br /&gt;
| [[Media:Eccentric_Chainrings_2015.pdf|Eccentric Chainrings Publications]]&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| April 2015&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Abbiss, C. R., Quod, M. J., Levin, G., Martin, D. T. &amp;amp; Laursen, P. B. (2009): Accuracy of the Velotron ergometer and SRM power meter. International journal of sports medicine, 30 (2), 107-112. doi: 10.1055/s-0028-1103285.&lt;br /&gt;
&lt;br /&gt;
Abbiss, C. R., Quod, M. J., Martin, D. T., Netto, K. J., Nosaka, K., Lee, H. et al. (2006): Dynamic pacing strategies during the cycle phase of an Ironman triathlon. Medicine and science in sports and exercise, 38 (4), 726-734. doi: 10.1249/01.mss.0000210202.33070.55.&lt;br /&gt;
&lt;br /&gt;
Abel, T., Burkett, B., Schneider, S., Lindschulten, R. &amp;amp; Strüder, H. K. (2010): The exercise profile of an ultra-long handcycling race: the Styrkeprøven experience. Spinal cord, 48 (12), 894-898. doi: 10.1038/sc.2010.40.&lt;br /&gt;
&lt;br /&gt;
Antonutto, G., Capelli, C., Girardis, M., Zamparo, P. &amp;amp; Di Prampero, P. E. (1999): Effects of microgravity on maximal power of lower limbs during very short efforts in humans. Journal of applied physiology (Bethesda, Md, 86 (1), 85-92.&lt;br /&gt;
&lt;br /&gt;
Arkesteijn, M., Hopker, J., Jobson, S. &amp;amp; Passfield, L. (2013): The Effect of Turbo Trainer Cycling on Pedalling Technique and Cycling Efficiency. International journal of sports medicine, 34 (06), 520-525. doi: 10.1055/s-0032-1327658.&lt;br /&gt;
&lt;br /&gt;
Ashenden, M. J., Gore, C. J., Burge, C. M., Clough, M. L., Bourdon, P. C., Dobson, G. P. et al. (1999): Skin-prick blood samples are reliable for estimating Hb mass with the CO-dilution technique. European journal of applied physiology and occupational physiology, 79 (6), 535-537.&lt;br /&gt;
&lt;br /&gt;
Ashenden, M. J., Gore, C. J., Dobson, G. P., Boston, T. T., Parisotto, R., Emslie, K. R. et al. (2000): Simulated moderate altitude elevates serum erythropoietin but does not increase reticulocyte production in well-trained runners. European journal of applied physiology, 81 (5), 428-435. doi: 10.1007/s004210050064.&lt;br /&gt;
&lt;br /&gt;
Ashenden, M. J., Gore, C. J., Dobson, G. P. &amp;amp; Hahn, A. G. (1999): &amp;quot;Live high, train low&amp;quot; does not change the total haemoglobin mass of male endurance athletes sleeping at a simulated altitude of 3000 m for 23 nights. European journal of applied physiology and occupational physiology, 80 (5), 479-484.&lt;br /&gt;
&lt;br /&gt;
Ashenden, M. J., Gore, C. J., Martin, D. T., Dobson, G. P. &amp;amp; Hahn, A. G. (1999): Effects of a 12-day &amp;quot;live high, train low&amp;quot; camp on reticulocyte production and haemoglobin mass in elite female road cyclists. European journal of applied physiology and occupational physiology, 80 (5), 472-478.&lt;br /&gt;
&lt;br /&gt;
Ashenden, M. J., Hahn, A. G., Martin, D. T., Logan, P., Parisotto, R. &amp;amp; Gore, C. J. (2001): A comparison of the physiological response to simulated altitude exposure and r-HuEpo administration. Journal of sports sciences, 19 (11), 831-837. doi: 10.1080/026404101753113778.&lt;br /&gt;
&lt;br /&gt;
Ashenden, M. J., Gore, C. J., Parisotto, R., Sharpe, K., Hopkins, W. G. &amp;amp; Hahn, A. G. (2003): Effect of altitude on second-generation blood tests to detect erythropoietin abuse by athletes. Haematologica, 88 (9), 1053-1062.&lt;br /&gt;
&lt;br /&gt;
Aughey, R. J., Clark, S. A., Gore, C. J., Townsend, N. E., Hahn, A. G., Kinsman, T. A. et al. (2006): Interspersed normoxia during live high, train low interventions reverses an early reduction in muscle Na+, K +ATPase activity in well-trained athletes. European journal of applied physiology, 98 (3), 299-309. doi: 10.1007/s00421-006-0280-z.&lt;br /&gt;
&lt;br /&gt;
Aughey, R. J., Gore, C. J., Hahn, A. G., Garnham, A. P., Clark, S. A., Petersen, A. C. et al. (2005): Chronic intermittent hypoxia and incremental cycling exercise independently depress muscle in vitro maximal Na+-K+-ATPase activity in well-trained athletes. Journal of applied physiology (Bethesda, Md. : 1985), 98 (1), 186-192. doi: 10.1152/japplphysiol.01335.2003.&lt;br /&gt;
&lt;br /&gt;
Austin, N., Nilwik, R. &amp;amp; Herzog, W. (2010): In vivo operational fascicle lengths of vastus lateralis during sub-maximal and maximal cycling. Journal of biomechanics, 43 (12), 2394-2399. doi: 10.1016/j.jbiomech.2010.04.016.&lt;br /&gt;
&lt;br /&gt;
Balmer, J., Davison, R. C. &amp;amp; Bird, S. R. (2000): Peak power predicts performance power during an outdoor 16.1-km cycling time trial. Medicine and science in sports and exercise, 32 (8), 1485-1490.&lt;br /&gt;
&lt;br /&gt;
Balmer, J., Davison, R. C. &amp;amp; Bird, S. R. (2000): Reliability of an air-braked ergometer to record peak power during a maximal cycling test. Medicine and science in sports and exercise, 32 (10), 1790-1793.Balmer, Davison et al. 2000 – The validity of power output&lt;br /&gt;
&lt;br /&gt;
Balmer, J., Davison, R. C., Coleman, D. A. &amp;amp; Bird, S. R. (2000): The validity of power output recorded during exercise performance tests using a Kingcycle air-braked cycle ergometer when compared with an SRM powermeter. International journal of sports medicine, 21 (3), 195-199. doi: 10.1055/s-2000-9466.&lt;br /&gt;
&lt;br /&gt;
Balmer, J., Bird, S., Davison, R. C. R., Doherty, M. &amp;amp; Smith, P. (2004): Mechanically braked Wingate powers: agreement between SRM, corrected and conventional methods of measurement. Journal of sports sciences, 22 (7), 661-667. doi: 10.1080/02640410310001655831.&lt;br /&gt;
&lt;br /&gt;
Balmer, J., Bird, S., Davison, R. &amp;amp; Lucia, A. (2008): Effect of age on 16.1-km time-trial performance. Journal of sports sciences, 26 (2), 197-206. doi: 10.1080/02640410701446901.&lt;br /&gt;
&lt;br /&gt;
Barratt, P. (2008): SRM Torque Analysis of Standing Starts in Track Cycling (P85). In  The Engineering of Sport 7 (Volume 1, S. 443-448).&lt;br /&gt;
&lt;br /&gt;
Bassett, D. R., Kyle, C. R., Passfield, L., Broker, J. P. &amp;amp; Burke, E. R. (1999): Comparing cycling world hour records, 1967-1996: modeling with empirical data. Medicine and science in sports and exercise, 31 (11), 1665-1676.&lt;br /&gt;
&lt;br /&gt;
Bentley, D. J., McNaughton, L. R., Thompson, D., Vleck, V. E. &amp;amp; Batterham, A. M. (2001): Peak power output, the lactate threshold, and time trial performance in cyclists. Medicine and science in sports and exercise, 33 (12), 2077-2081.&lt;br /&gt;
&lt;br /&gt;
Bertucci, W., Crequy, S. &amp;amp; Chiementin, X. (2012). Validity and Reliability of the G-Cog BMX Powermeter. International journal of sports medicine. doi: 10.1055/s-0031-1301319.&lt;br /&gt;
&lt;br /&gt;
Bertucci, W., Duc, S., Villerius, V. &amp;amp; Grappe, F. (2005): Validity and reliability of the Axiom PowerTrain cycle ergometer when compared with an SRM powermeter. International journal of sports medicine, 26 (1), 59-65. doi: 10.1055/s-2004-817855.&lt;br /&gt;
&lt;br /&gt;
Bertucci, W., Duc, S., Villerius, V., Pernin, J. N. &amp;amp; Grappe, F. (2005): Validity and reliability of the PowerTap mobile cycling powermeter when compared with the SRM Device. International journal of sports medicine, 26 (10), 868-873. doi: 10.1055/s-2005-837463.&lt;br /&gt;
&lt;br /&gt;
Bertucci, W., Taiar, R. &amp;amp; Grappe, F. (2005): Differences between sprint tests under laboratory and actual cycling conditions. The Journal of sports medicine and physical  fitness, 45 (3), 277-283.&lt;br /&gt;
&lt;br /&gt;
Bertucci, W., Grappe, F., Girard, A., Betik, A. &amp;amp; Rouillon, J. D. (2005): Effects on the crank torque profile when changing pedalling cadence in level ground and uphill road cycling. Journal of biomechanics, 38 (5), 1003-1010. doi: 10.1016/j.jbiomech.2004.05.037.&lt;br /&gt;
&lt;br /&gt;
Bertucci, W., Grappe, F. &amp;amp; Groslambert, A. (2007): Laboratory versus outdoor cycling conditions: differences in pedaling biomechanics. Journal of applied biomechanics, 23 (2), 87-92.&lt;br /&gt;
&lt;br /&gt;
Billaut, F., Gore, C. J. &amp;amp; Aughey, R. J. (2012): Enhancing team-sport athlete performance: is altitude training relevant? Sports medicine (Auckland, N.Z.), 42 (9), 751-767. doi: 10.2165/11634050-000000000-00000.&lt;br /&gt;
&lt;br /&gt;
Brickley, G., Dekerle, J., Hammond, A., Pringle, J. &amp;amp; Carter, H. (2007): Assessment of Maximal Aerobic Power and Critical Power in a Single 90-s Isokinetic All-Out Cycling Test. International journal of sports medicine, 28 (5), 414-419. doi: 10.1055/s-2006-924513.&lt;br /&gt;
&lt;br /&gt;
Broker, J. P., Kyle, C. R. &amp;amp; Burke, E. R. (1999): Racing cyclist power requirements in the 4000-m individual and team pursuits. Medicine and science in sports and exercise, 31 (11), 1677-1685.&lt;br /&gt;
&lt;br /&gt;
Brosnan, M. J., Martin, D. T., Hahn, A. G., Gore, C. J. &amp;amp; Hawley, J. A. (2000): Impaired interval exercise responses in elite female cyclists at moderate simulated altitude. Journal of applied physiology (Bethesda, Md. : 1985), 89 (5), 1819-1824.&lt;br /&gt;
&lt;br /&gt;
Cangley, P., Passfield, L., Carter, H. &amp;amp; Bailey, M. (2011): The Effect of Variable Gradients on Pacing in Cycling Time-Trials. International journal of sports medicine, 32 (02), 132-136. doi: 10.1055/s-0030-1268440.&lt;br /&gt;
&lt;br /&gt;
Carpes, F. P., Rossato, M., Faria, I. E. &amp;amp; Bolli Mota, C. (2007): Bilateral pedaling asymmetry during a simulated 40-km cycling time-trial. The Journal of sports medicine and physical fitness, 47 (1), 51-57.&lt;br /&gt;
&lt;br /&gt;
Clark, S. A., Bourdon, P. C., Schmidt, W., Singh, B., Cable, G., Onus, K. J. et al. (2007): The effect of acute simulated moderate altitude on power, performance and pacing strategies in well-trained cyclists. European journal of applied physiology, 102 (1), 45-55. doi: 10.1007/s00421-007-0554-0.&lt;br /&gt;
&lt;br /&gt;
Clark, S. A., Quod, M. J., Clark, M. A., Martin, D. T., Saunders, P. U. &amp;amp; Gore, C. J. (2009): Time course of haemoglobin mass during 21 days live high:train low simulated altitude. European journal of applied physiology, 106 (3), 399-406. doi: 10.1007/s00421-009-1027-4.&lt;br /&gt;
&lt;br /&gt;
Clark, S. K. &amp;amp; Johnson, T. M. (2010): Selenium stable isotope investigation into selenium biogeochemical cycling in a lacustrine environment: Sweitzer Lake, Colorado. Journal of environmental quality, 39 (6), 2200-2210.&lt;br /&gt;
&lt;br /&gt;
Coleman, D. A., Wiles, J. D., Nunn, M. &amp;amp; Smith, M. F. (2005): Reliability of sprint test indices in well-trained cyclists. International journal of sports medicine, 26 (5), 383-387. doi: 10.1055/s-2004-821226.&lt;br /&gt;
&lt;br /&gt;
Doherty, M., Balmer, J., Davison, R. C. R., Robinson, L. &amp;amp; Smith, P. M. (2003): Reliability of a combined 3-min constant load and performance cycling test. International journal of sports medicine, 24 (5), 366-371. doi: 10.1055/s-2003-40700.&lt;br /&gt;
&lt;br /&gt;
Duc, S., Betik, A.-C. &amp;amp; Grappe, F. (2005): EMG activity does not change during a time trial in competitive cyclists. International journal of sports medicine, 26 (2), 145-150. doi: 10.1055/s-2004-817922.&lt;br /&gt;
&lt;br /&gt;
Duc, S., Villerius, V., Bertucci, W. &amp;amp; Grappe, F. (2007): Validity and reproducibility of the ErgomoPro power meter compared  with the SRM and Powertap power meters. International journal of sports physiology and performance, 2 (3), 270-281.&lt;br /&gt;
&lt;br /&gt;
Duc, S., Villerius, V., Bertucci, W., Pernin, J. N. &amp;amp; Grappe, F. (2005): Muscular activity level during pedalling is not affected by crank inertial load. European journal of applied physiology, 95 (2-3), 260-264. doi: 10.1007/s00421-005-1401-9.&lt;br /&gt;
&lt;br /&gt;
Duc, S., Villerius, V., Bertucci, W. &amp;amp; Grappe, F. (2007): Validity and reproducibility of the ErgomoPro power meter compared with the SRM and Powertap power meters. International journal of sports physiology and performance, 2 (3), 270-281.&lt;br /&gt;
&lt;br /&gt;
Eastwood, A., Sharpe, K., Bourdon, P. C., Woolford, S. M., Saunders, P. U., Robertson, E. Y. et al. (2012): Within-subject variation in hemoglobin mass in elite athletes. Medicine and science in sports and exercise, 44 (4), 725-732. doi: 10.1249/MSS.0b013e318238ea7f.&lt;br /&gt;
&lt;br /&gt;
Ebert, T. R., Martin, D. T., McDonald, W., Victor, J., Plummer, J. &amp;amp; Withers, R. T. (2005): Power output during women's World Cup road cycle racing. European journal of applied physiology, 95 (5-6), 529-536. doi: 10.1007/s00421-005-0039-y.&lt;br /&gt;
&lt;br /&gt;
Ebert, T. R., Martin, D. T., Stephens, B. &amp;amp; Withers, R. T. (2006): Power output during a professional men's road-cycling tour. International journal of sports physiology and performance, 1 (4), 324-335.&lt;br /&gt;
&lt;br /&gt;
Emonson, D. L., Aminuddin, A. H., Wight, R. L., Scroop, G. C. &amp;amp; Gore, C. J. (1997): Training-induced increases in sea level VO2max and endurance are not enhanced by acute hypobaric exposure. European journal of applied physiology and occupational physiology, 76 (1), 8-12.&lt;br /&gt;
&lt;br /&gt;
Faiss, R., Praz, M., Meichtry, A., Gobelet, C. &amp;amp; Deriaz, O. (2007): The effect of mountain bike suspensions on vibrations and off-road uphill performance. The Journal of sports medicine and physical fitness, 47 (2), 151-158.&lt;br /&gt;
&lt;br /&gt;
Frese, S., Valdivieso, P., Jaecker, V. C., Harms, S. A., Konou, T. M., Tappe, K. A. et al. (2016): Expression of Metabolic and Myogenic Factors during two Competitive Seasons in Elite Junior Cyclists. Deutsche Zeitschrift für Sportmedizin, 2016 (06), 150-158. doi: 10.5960/dzsm.2016.239.&lt;br /&gt;
&lt;br /&gt;
Fu, Q., Townsend, N. E., Shiller, S. M., Martini, E. R., Okazaki, K., Shibata, S. et al. (2007): Intermittent hypobaric hypoxia exposure does not cause sustained alterations in autonomic control of blood pressure in young athletes. American journal of physiology. Regulatory, integrative and comparative physiology, 292 (5), R1977-84. doi: 10.1152/ajpregu.00622.2006.&lt;br /&gt;
&lt;br /&gt;
Gardner, A. S., Martin, D. T., Jenkins, D. G., Dyer, I., van Eiden, J., Barras, M. et al. (2009): Velocity-specific fatigue: quantifying fatigue during variable velocity cycling. Medicine and science in sports and exercise, 41 (4), 904-911. doi: 10.1249/MSS.0b013e318190c2cc.&lt;br /&gt;
&lt;br /&gt;
Gardner, A. S., Martin, J. C., Martin, D. T., Barras, M. &amp;amp; Jenkins, D. G. (2007): Maximal torque- and power-pedaling rate relationships for elite sprint cyclists in laboratory and field tests. European journal of applied physiology, 101 (3), 287-292. doi: 10.1007/s00421-007-0498-4.&lt;br /&gt;
&lt;br /&gt;
Gardner, A. S., Stephens, S., Martin, D. T., Lawton, E., Lee, H. &amp;amp; Jenkins, D. (2004): Accuracy of SRM and power tap power monitoring systems for bicycling. Medicine and science in sports and exercise, 36 (7), 1252-1258.&lt;br /&gt;
&lt;br /&gt;
Garvican, L. A., Hammond, K., Varley, M. C., Gore, C. J., Billaut, F. &amp;amp; Aughey, R. J. (2013): Lower Running Performance and Exacerbated Fatigue in Soccer Played at 1600 m. International journal of sports physiology and performance.&lt;br /&gt;
&lt;br /&gt;
Garvican, L. A., Martin, D. T., Clark, S. A., Schmidt, W. F. &amp;amp; Gore, C. J. (2007): Variability of erythropoietin response to sleeping at simulated altitude: a cycling case study. International journal of sports physiology and performance, 2 (3), 327-331.&lt;br /&gt;
&lt;br /&gt;
Garvican, L. A., Pottgiesser, T., Martin, D. T., Schumacher, Y. O., Barras, M. &amp;amp; Gore, C. J. (2011): The contribution of haemoglobin mass to increases in cycling performance induced by simulated LHTL. European journal of applied physiology, 111 (6), 1089-1101. doi: 10.1007/s00421-010-1732-z.&lt;br /&gt;
&lt;br /&gt;
Garvican, L. A., Saunders, P. U., Pyne, D. B., Martin, D. T., Robertson, E. Y. &amp;amp; Gore, C. J. (2012): Hemoglobin mass response to simulated hypoxia &amp;quot;blinded&amp;quot; by noisy measurement? Journal of applied physiology (Bethesda, Md. : 1985), 112 (10), 1797-8; author reply 1799. doi: 10.1152/japplphysiol.00212.2012.&lt;br /&gt;
&lt;br /&gt;
Giacomoni, M., Billaut, F. &amp;amp; Falgairette, G. (2006): Effects of the Time of Day on Repeated All-Out Cycle Performance and Short-Term Recovery Patterns. International journal of sports medicine, 27 (6), 468-474. doi: 10.1055/s-2005-865822.&lt;br /&gt;
&lt;br /&gt;
González-Haro, C., Galilea, P. A. &amp;amp; Escanero, J. F. (2008):Comparison of different theoretical models estimating peak power output and maximal oxygen uptake in trained and elite triathletes and endurance cyclists in the velodrome. Journal of sports sciences, 26 (6), 591-601. doi: 10.1080/02640410701646245.&lt;br /&gt;
&lt;br /&gt;
González-Haro, C., Galilea Ballarini, P. A., Soria, M., Drobnic, F. &amp;amp; Escanero, J. F. (2007): Comparison of nine theoretical models for estimating the mechanical power output in cycling. British journal of sports medicine, 41 (8), 506-9; discussion 509. doi: 10.1136/bjsm.2006.034934.&lt;br /&gt;
&lt;br /&gt;
Goosey-Tolfrey, V., Castle, P., Webborn, N. &amp;amp; Abel, T. (2006). Aerobic capacity and peak power output of elite quadriplegic games players. British journal of sports medicine, 40 (8), 684-687. doi: 10.1136/bjsm.2006.026815.&lt;br /&gt;
&lt;br /&gt;
Gordon, R. S., Franklin, K. L., Davies, B. &amp;amp; Baker, J. S. (2007): Further mechanical considerations between polar and SRM mobile ergometer systems during laboratory-based high-intensity, intermittent cycling activity. Research in sports medicine (Print), 15 (4), 241-247. doi: 10.1080/15438620701525540.&lt;br /&gt;
&lt;br /&gt;
Gore, C. J., Hahn, A., Rice, A., Bourdon, P., Lawrence, S., Walsh, C. et al. (1998): Altitude training at 2690m does not increase total haemoglobin mass or sea level VO2max in world champion track cyclists. Journal of science and medicine in sport / Sports Medicine Australia, 1 (3), 156-170.&lt;br /&gt;
&lt;br /&gt;
Gore, C. J. &amp;amp; Hahn, A. G. (2005): Letter to the editors - Re: Heinicke K, Heinicke I, Schmidt W, Wolfarth B. A three-week traditional altitude training increases hemoglobin mass and red cell volume in elite biathlon athletes. Int J Sports Med 2005; 26: 350-355. International journal of sports medicine, 26 (6), 504-5; author reply 506-7. doi: 10.1055/s-2005-865832.&lt;br /&gt;
&lt;br /&gt;
Gore, C. J., Hahn, A. G., Aughey, R. J., Martin, D. T., Ashenden, M. J., Clark, S. A. et al. (2001): Live high:train low increases muscle buffer capacity and submaximal cycling efficiency. Acta physiologica Scandinavica, 173 (3), 275-286. doi: 10.1046/j.1365-201X.2001.00906.x.&lt;br /&gt;
&lt;br /&gt;
Gore, C. J., Hahn, A. G., Burge, C. M. &amp;amp; Telford, R. D. (1997): VO2max and haemoglobin mass of trained athletes during high intensity training. International journal of sports medicine, 18 (6), 477-482. doi: 10.1055/s-2007-972667.&lt;br /&gt;
&lt;br /&gt;
Gore, C. J., Hahn, A. G., Scroop, G. C., Watson, D. B., Norton, K. I., Wood, R. J. et al. (1996): Increased arterial desaturation in trained cyclists during maximal exercise at 580 m altitude. Journal of applied physiology (Bethesda, Md. : 1985), 80 (6), 2204-2210.&lt;br /&gt;
&lt;br /&gt;
Gore, C. J., Little, S. C., Hahn, A. G., Scroop, G. C., Norton, K. I., Bourdon, P. C. et al. (1997): Reduced performance of male and female athletes at 580 m altitude. European journal of applied physiology and occupational physiology, 75 (2), 136-143.&lt;br /&gt;
&lt;br /&gt;
Gore, C. J., McSharry, P. E., Hewitt, A. J. &amp;amp; Saunders, P. U. (2008): Preparation for football competition at moderate to high altitude. Scandinavian journal of medicine &amp;amp; science in sports, 18 Suppl 1, 85-95. doi: 10.1111/j.1600-0838.2008.00836.x.&lt;br /&gt;
&lt;br /&gt;
Gore, C. J., Rodríguez, F. A., Truijens, M. J., Townsend, N. E., Stray-Gundersen, J. &amp;amp; Levine, B. D. (2006): Increased serum erythropoietin but not red cell production after 4 wk of intermittent hypobaric hypoxia (4,000-5,500 m). Journal of applied physiology (Bethesda, Md. : 1985), 101 (5), 1386-1393. doi: 10.1152/japplphysiol.00342.2006.&lt;br /&gt;
&lt;br /&gt;
Gore, C. J., Clark, S. A. &amp;amp; Saunders, P. U. (2007): Nonhematological mechanisms of improved sea-level performance after hypoxic exposure. Medicine and science in sports and exercise, 39 (9), 1600-1609. doi: 10.1249/mss.0b013e3180de49d3.&lt;br /&gt;
&lt;br /&gt;
Gough, C. E., Sharpe, K., Garvican, L. A., Anson, J. M., Saunders, P. U. &amp;amp; Gore, C. J. (2013): The effects of injury and illness on haemoglobin mass. International journal of sports medicine, 34 (9), 763-769. doi: 10.1055/s-0033-1333692.&lt;br /&gt;
&lt;br /&gt;
Gough, C. E., Saunders, P. U., Fowlie, J., Savage, B., Pyne, D. B., Anson, J. M. et al. (2012): Influence of altitude training modality on performance and total haemoglobin mass in elite swimmers. European journal of applied physiology, 112 (9), 3275-3285. doi: 10.1007/s00421-011-2291-7.&lt;br /&gt;
&lt;br /&gt;
Groslambert, A., Grappe, F., Bertucci, W., Perrey, S., Girard, A. J. &amp;amp; Rouillon, J. D. (2004): A perceptive individual time trial performed by triathletes to estimate the anaerobic threshold. A preliminary study. The Journal of sports medicine and physical fitness, 44 (2), 147-156.&lt;br /&gt;
&lt;br /&gt;
Haakonssen, E. C., Martin, D. T., Burke, L. M. &amp;amp; Jenkins, D. G. (2013): Energy expenditure of constant- and variable-intensity cycling: power meter estimates. Medicine and science in sports and exercise, 45 (9), 1833-1840. doi: 10.1249/MSS.0b013e31828e18e6.&lt;br /&gt;
&lt;br /&gt;
Hahn, A. G. &amp;amp; Gore, C. J. (2001): The effect of altitude on cycling performance: a challenge to traditional concepts. Sports medicine (Auckland, N.Z.), 31 (7), 533-557.&lt;br /&gt;
&lt;br /&gt;
Hahn, A. G., Gore, C. J., Martin, D. T., Ashenden, M. J., Roberts, A. D. &amp;amp; Logan, P. A. (2001): An evaluation of the concept of living at moderate altitude and training at sea level. Comparative biochemistry and physiology. Part A, Molecular &amp;amp; integrative physiology, 128 (4), 777-789.&lt;br /&gt;
&lt;br /&gt;
Hajoglou, A., Foster, C., Koning, J. J. de, Lucia, A., Kernozek, T. W. &amp;amp; Porcari, J. P. (2005): Effect of warm-up on cycle time trial performance. Medicine and science in sports and exercise, 37 (9), 1608-1614.&lt;br /&gt;
&lt;br /&gt;
Hopker, J., Myers, S., Jobson, S. A., Bruce, W. &amp;amp; Passfield, L. (2010): Validity and reliability of the Wattbike cycle ergometer. International journal of sports medicine, 31 (10), 731-736. doi: 10.1055/s-0030-1261968.&lt;br /&gt;
&lt;br /&gt;
Hurst, H. T. &amp;amp; Atkins, S. (2006): Agreement between polar and SRM mobile ergometer systems during laboratory-based high-intensity, intermittent cycling activity. Journal of sports sciences, 24 (8), 863-868. doi: 10.1080/02640410500245678.&lt;br /&gt;
&lt;br /&gt;
Hurst, H. T. &amp;amp; Atkins, S. (2006): Power output of field-based downhill mountain biking. Journal of sports sciences, 24 (10), 1047-1053. doi: 10.1080/02640410500431997.&lt;br /&gt;
&lt;br /&gt;
Jobson, S., Woodside, J., Passfield, L. &amp;amp; Nevill, A. (2008): Allometric Scaling of Uphill Cycling Performance. International journal of sports medicine, 29 (09), 753-757. doi: 10.1055/s-2007-989441.&lt;br /&gt;
&lt;br /&gt;
Jobson, S. A., Passfield, L., Atkinson, G., Barton, G. &amp;amp; Scarf, P. (2009): The analysis and utilization of cycling training data. Sports medicine (Auckland, N.Z.), 39 (10), 833-844. doi: 10.2165/11317840-000000000-00000.&lt;br /&gt;
&lt;br /&gt;
Julian, C. G., Gore, C. J., Wilber, R. L., Daniels, J. T., Fredericson, M., Stray-Gundersen, J. et al. (2004): Intermittent normobaric hypoxia does not alter performance or erythropoietic markers in highly trained distance runners. Journal of applied physiology (Bethesda, Md. : 1985), 96 (5), 1800-1807. doi: 10.1152/japplphysiol.00969.2003.&lt;br /&gt;
&lt;br /&gt;
Karsten, B., Jobson, S. A., Hopker, J., Jimenez, A. &amp;amp; Beedie, C. (2014): High Agreement between Laboratory and Field Estimates of Critical Power in Cycling. International journal of sports medicine, 35 (4), 298-303. doi: 10.1055/s-0033-1349844.&lt;br /&gt;
&lt;br /&gt;
Karsten, B., Jobson, S. A., Hopker, J., Passfield, L. &amp;amp; Beedie, C. (2013): The 3-min Test Does not Provide a Valid Measure of Critical Power Using the SRM Isokinetic Mode. International journal of sports medicine. doi: 10.1055/s-0033-1349093.&lt;br /&gt;
&lt;br /&gt;
Kinsman, T. A., Gore, C. J., Hahn, A. G., Hopkins, W. G., Hawley, J. A., McKenna, M. J. et al. (2005): Sleep in athletes undertaking protocols of exposure to nocturnal simulated altitude at 2650 m. Journal of science and medicine in sport / Sports Medicine Australia, 8 (2), 222-232.&lt;br /&gt;
&lt;br /&gt;
Kinsman, T. A., Hahn, A. G., Gore, C. J., Martin, D. T. &amp;amp; Chow, C. M. (2003): Sleep quality responses to atmospheric variation: case studies of two elite female cyclists. Journal of science and medicine in sport / Sports Medicine Australia, 6 (4), 436-442.&lt;br /&gt;
&lt;br /&gt;
Kinsman, T. A., Hahn, A. G., Gore, C. J., Wilsmore, B. R., Martin, D. T. &amp;amp; Chow, C.-M. (2002): Respiratory events and periodic breathing in cyclists sleeping at 2,650-m simulated altitude. Journal of applied physiology (Bethesda, Md. : 1985), 92 (5), 2114-2118. doi: 10.1152/japplphysiol.00737.2001.&lt;br /&gt;
&lt;br /&gt;
Kinsman, T. A., Townsend, N. E., Gore, C. J., Hahn, A. G., Clark, S. A., Aughey, R. J. et al. (2005): Sleep disturbance at simulated altitude indicated by stratified respiratory disturbance index but not hypoxic ventilatory response. European journal of applied physiology, 94 (5-6), 569-575. doi: 10.1007/s00421-005-1368-6.&lt;br /&gt;
&lt;br /&gt;
Kirkland, A., Coleman, D., Wiles, J. D. &amp;amp; Hopker, J. (2008): Validity and reliability of the Ergomopro powermeter. International journal of sports medicine, 29 (11), 913-916. doi: 10.1055/s-2008-1038621.&lt;br /&gt;
&lt;br /&gt;
Loughlin, A. F., Skiles, G. L., Alberts, D. W. &amp;amp; Schaefer, W. H. (2001): An ion exchange liquid chromatography/mass spectrometry method for the determination of reduced and oxidized glutathione and glutathione conjugates in hepatocytes. Journal of pharmaceutical and biomedical analysis, 26 (1), 131-142.&lt;br /&gt;
&lt;br /&gt;
MacIntosh, B. R., Svedahl, K. &amp;amp; Kim, M. (2004): Fatigue and optimal conditions for short-term work capacity. European journal of applied physiology, 92 (4-5), 369-375. doi: 10.1007/s00421-004-1177-3.&lt;br /&gt;
&lt;br /&gt;
MacRae HS-H, Hise, K. J. &amp;amp; Allen, P. J. (2000): Effects of front and dual suspension mountain bike systems on uphill cycling performance. Medicine and science in sports and exercise, 32 (7), 1276-1280.&lt;br /&gt;
&lt;br /&gt;
Maier, T., Steiner, T., Trösch, S., Müller, B. &amp;amp; Wehrlin, J. P. (2014): Reliability of power meter calibration by mathematical modelling of treadmill cycling. J Sci Cycling (Vol. 3(2), 28).&lt;br /&gt;
&lt;br /&gt;
Mc Naughton, L. R., Sherman, R., Roberts, S. &amp;amp; Bentley, D. J. (2005): Portable gas analyser Cosmed K4b2 compared to a laboratory based mass spectrometer system. The Journal of sports medicine and physical fitness, 45 (3), 315-323.&lt;br /&gt;
&lt;br /&gt;
McDaniel, J., Subudhi, A. &amp;amp; Martin, J. C. (2005): Torso stabilization reduces the metabolic cost of producing cycling power. Canadian journal of applied physiology = Revue canadienne de physiologie appliquée, 30 (4), 433-441.&lt;br /&gt;
&lt;br /&gt;
McLean, B. D., Buttifant, D., Gore, C. J., White, K., Liess, C. &amp;amp; Kemp, J. (2013): Physiological and performance responses to a preseason altitude-training camp in elite team-sport athletes. International journal of sports physiology and performance, 8 (4), 391-399.&lt;br /&gt;
&lt;br /&gt;
Menaspa, P., Quod, M., Martin, D. T., Peiffer, J. J. &amp;amp; Abbiss, C. R. (2015): Physical Demands of Sprinting in Professional Road Cycling. International journal of sports medicine, 36 (13), 1058-1062. doi: 10.1055/s-0035-1554697.&lt;br /&gt;
&lt;br /&gt;
Meyer, T., Gabriel, H. H. W., Auracher, M., Scharhag, J. &amp;amp; Kindermann, W. (2003): Metabolic profile of 4 h cycling in the field with varying amounts of carbohydrate supply. European journal of applied physiology, 88 (4-5), 431-437. doi: 10.1007/s00421-002-0712-3.&lt;br /&gt;
&lt;br /&gt;
Mijnarends, D. M., Meijers, J. M. M., Halfens, R. J. G., Ter Borg, S., Luiking, Y. C., Verlaan, S. et al. (2013): Validity and reliability of tools to measure muscle mass, strength, and physical performance in community-dwelling older people: a systematic review. Journal of the American Medical Directors Association, 14 (3), 170-178. doi: 10.1016/j.jamda.2012.10.009.&lt;br /&gt;
&lt;br /&gt;
Millet, G. P., Tronche, C., Fuster, N., Bentley, D. J. &amp;amp; Candau, R. (2003): Validity and reliability of the Polar S710 mobile cycling powermeter. International journal of sports medicine, 24 (3), 156-161. doi: 10.1055/s-2003-39083.&lt;br /&gt;
&lt;br /&gt;
Millet, G. P., Tronche, C., Fuster, N. &amp;amp; Candau, R. (2002): Level ground and uphill cycling efficiency in seated and standing positions. Medicine and science in sports and exercise, 34 (10), 1645-1652. doi: 10.1249/01.MSS.0000031482.14781.D7.&lt;br /&gt;
&lt;br /&gt;
Mornieux, G., Gollhofer, A. &amp;amp; Stapelfeldt, B. (2010): Muscle Coordination while Pulling up During Cycling. International journal of sports medicine, 31 (12), 843-846. doi: 10.1055/s-0030-1263140.&lt;br /&gt;
&lt;br /&gt;
Mornieux, G., Stapelfeldt, B., Gollhofer, A. &amp;amp; Belli, A. (2008): Effects of Pedal Type and Pull-Up Action during Cycling: International journal of sports medicine, 29 (10), 817-822. doi: 10.1055/s-2008-1038374.&lt;br /&gt;
&lt;br /&gt;
Neville, V., Zaher, N., Pain, M. T. G. &amp;amp; Folland, J. P. (2009): Lower limb influence on standing arm-cranking ('grinding'). International journal of sports medicine, 30 (10), 713-718. doi: 10.1055/s-0029-1231044.&lt;br /&gt;
&lt;br /&gt;
Neville, V., Pain, M. T. G. &amp;amp; Folland, J. P. (2009): Aerobic power and peak power of elite America's Cup sailors. European journal of applied physiology, 106 (1), 149-157. doi: 10.1007/s00421-009-1002-0.&lt;br /&gt;
&lt;br /&gt;
Neville, V., Pain, M. T. G., Kantor, J. &amp;amp; Folland, J. P. (2010): Influence of crank length and crank-axle height on standing arm-crank (grinding) power. Medicine and science in sports and exercise, 42 (2), 381-387. doi: 10.1249/MSS.0b013e3181b46f3a.&lt;br /&gt;
&lt;br /&gt;
Neya, M., Enoki, T., Ohiwa, N., Kawahara, T. &amp;amp; Gore, C. J. (2013) Increased hemoglobin mass and VO2max with 10 h nightly simulated altitude at 3000 m. International journal of sports physiology and performance, 8 (4), 366-372.&lt;br /&gt;
&lt;br /&gt;
Nimmerichter, A., Williams, C., Bachl, N. &amp;amp; Eston, R. (2010): Evaluation of a field test to assess performance in elite cyclists. International journal of sports medicine, 31 (3), 160-166. doi: 10.1055/s-0029-1243222.&lt;br /&gt;
&lt;br /&gt;
Nimmerichter, A., Eston, R. G., Bachl, N. &amp;amp; Williams, C. (2011): Longitudinal monitoring of power output and heart rate profiles in elite cyclists. Journal of sports sciences, 29 (8), 831-840. doi: 10.1080/02640414.2011.561869.&lt;br /&gt;
&lt;br /&gt;
Nimmerichter, A. &amp;amp; Williams, C. A. (2015): Comparison of power output during ergometer and track cycling in adolescent cyclists. Journal of strength and conditioning research / National Strength &amp;amp; Conditioning Association, 29 (4), 1049-1056. doi: 10.1519/JSC.0000000000000723.&lt;br /&gt;
&lt;br /&gt;
O’Hara, J., Thomas, A., Seims, A., Cooke, C. &amp;amp; King, R. (2012): Reliability of a High-Intensity Endurance Cycling Test. International journal of sports medicine, 33 (01), 18-25. doi: 10.1055/s-0031-1284340.&lt;br /&gt;
&lt;br /&gt;
Parisotto, R., Gore, C. J., Hahn, A. G., Ashenden, M. J., Olds, T. S., Martin, D. T. et al. (2000): Reticulocyte parameters as potential discriminators of recombinant human erythropoietin abuse in elite athletes. International journal of sports medicine, 21 (7), 471-479. doi: 10.1055/s-2000-7421.&lt;br /&gt;
&lt;br /&gt;
Paton, C. D. &amp;amp; Hopkins, W. G. (2001): Tests of cycling performance. Sports medicine (Auckland, N.Z.), 31 (7), 489-496.&lt;br /&gt;
&lt;br /&gt;
Paton, C. D. &amp;amp; Hopkins, W. G. (2006): Ergometer error and biological variation in power output in a performance test with three cycle ergometers. International journal of sports medicine, 27 (6), 444-447. doi: 10.1055/s-2005-865781.&lt;br /&gt;
&lt;br /&gt;
Périard, J. D., Caillaud, C. &amp;amp; Thompson, M. W. (2011): Central and peripheral fatigue during passive and exercise-induced hyperthermia. Medicine and science in sports and exercise, 43 (9), 1657-1665. doi: 10.1249/MSS.0b013e3182148a9a.&lt;br /&gt;
&lt;br /&gt;
Périard, J. D., Caillaud, C. &amp;amp; Thompson, M. W. (2012): The role of aerobic fitness and exercise intensity on endurance performance in uncompensable heat stress conditions. European journal of applied physiology, 112 (6), 1989-1999. doi: 10.1007/s00421-011-2165-z.&lt;br /&gt;
&lt;br /&gt;
Périard, J. D., Cramer, M. N., Chapman, P. G., Caillaud, C. &amp;amp; Thompson, M. W. (2011): Cardiovascular strain impairs prolonged self-paced exercise in the heat. Experimental physiology, 96 (2), 134-144. doi: 10.1113/expphysiol.2010.054213.&lt;br /&gt;
&lt;br /&gt;
Périard, J. D., Cramer, M. N., Chapman, P. G., Caillaud, C. &amp;amp; Thompson, M. W. (2011): Neuromuscular function following prolonged intense self-paced exercise in hot climatic conditions. European journal of applied physiology, 111 (8), 1561-1569. doi: 10.1007/s00421-010-1781-3.&lt;br /&gt;
&lt;br /&gt;
Perrey, S., Grappe, F., Girard, A., Bringard, A., Groslambert, A., Bertucci, W. et al. (2003): Physiological and metabolic responses of triathletes to a simulated 30-min time-trial in cycling at self-selected intensity. International journal of sports medicine, 24 (2), 138-143. doi: 10.1055/s-2003-38200.&lt;br /&gt;
&lt;br /&gt;
Pinot, J. &amp;amp; Grappe, F. (2011): The record power profile to assess performance in elite cyclists. International journal of sports medicine, 32 (11), 839-844. doi: 10.1055/s-0031-1279773.&lt;br /&gt;
&lt;br /&gt;
Pottgiesser, T., Garvican, L. A., Martin, D. T., Featonby, J. M., Gore, C. J. &amp;amp; Schumacher, Y. O. (2012): Short-term hematological effects upon completion of a four-week simulated altitude camp. International journal of sports physiology and performance, 7 (1), 79-83.&lt;br /&gt;
&lt;br /&gt;
Quod, M. J., Martin, D. T., Martin, J. C. &amp;amp; Laursen, P. B. (2010): The Power Profile Predicts Road Cycling MMP. International journal of sports medicine, 31 (06), 397-401. doi: 10.1055/s-0030-1247528.&lt;br /&gt;
&lt;br /&gt;
Reiser, M., Meyer, T., Kindermann, W. &amp;amp; Daugs, R. (2000): Transferability of workload measurements between three different types of ergometer. European journal of applied physiology, 82 (3), 245-249. doi: 10.1007/s004210050678.&lt;br /&gt;
&lt;br /&gt;
Reiser, R. &amp;amp; Hart, C. (2008): Cycling on Rollers: Kreitler Fan Resistance at Submaximal Levels of Effort. International journal of sports medicine, 29 (3), 212-216. doi: 10.1055/s-2007-965002.&lt;br /&gt;
&lt;br /&gt;
Richalet, J.-P. &amp;amp; Gore, C. J. (2008): Live and/or sleep high:train low, using normobaric hypoxia. Scandinavian journal of medicine &amp;amp; science in sports, 18 Suppl 1, 29-37. doi: 10.1111/j.1600-0838.2008.00830.x.&lt;br /&gt;
&lt;br /&gt;
Roberts, A. D., Clark, S. A., Townsend, N. E., Anderson, M. E., Gore, C. J. &amp;amp; Hahn, A. G. (2003): Changes in performance, maximal oxygen uptake and maximal accumulated oxygen deficit after 5, 10 and 15 days of live high:train low altitude exposure. European journal of applied physiology, 88 (4-5), 390-395. doi: 10.1007/s00421-002-0720-3.&lt;br /&gt;
&lt;br /&gt;
Robertson, E. Y., Saunders, P. U., Pyne, D. B., Aughey, R. J., Anson, J. M. &amp;amp; Gore, C. J. (2010): Reproducibility of performance changes to simulated live high/train low altitude. Medicine and science in sports and exercise, 42 (2), 394-401. doi: 10.1249/MSS.0b013e3181b34b57.&lt;br /&gt;
&lt;br /&gt;
Robertson, E. Y., Saunders, P. U., Pyne, D. B., Gore, C. J. &amp;amp; Anson, J. M. (2010): Effectiveness of intermittent training in hypoxia combined with live high/train low. European journal of applied physiology, 110 (2), 379-387. doi: 10.1007/s00421-010-1516-5.&lt;br /&gt;
&lt;br /&gt;
Rodríguez, F. A., Truijens, M. J., Townsend, N. E., Stray-Gundersen, J., Gore, C. J. &amp;amp; Levine, B. D. (2007): Performance of runners and swimmers after four weeks of intermittent hypobaric hypoxic exposure plus sea level training. Journal of applied physiology (Bethesda, Md. : 1985), 103 (5), 1523-1535. doi: 10.1152/japplphysiol.01320.2006.&lt;br /&gt;
&lt;br /&gt;
Rylands, L. P., Roberts, S. J. &amp;amp; Hurst, H. T. (2015): Variability in Laboratory vs. Field Testing of Peak Power, Torque, and Time of Peak Power Production Among Elite Bicycle Motocross Cyclists. Journal of strength and conditioning research / National Strength &amp;amp; Conditioning Association, 29 (9), 2635-2640. doi: 10.1519/JSC.0000000000000884.&lt;br /&gt;
&lt;br /&gt;
Sassi, A., Rampinini, E., Martin, D. T. &amp;amp; Morelli, A. (2009): Effects of gradient and speed on freely chosen cadence: the key role of crank inertial load. Journal of biomechanics, 42 (2), 171-177. doi: 10.1016/j.jbiomech.2008.10.008.&lt;br /&gt;
&lt;br /&gt;
Saunders, P. U., Telford, R. D., Pyne, D. B., Cunningham, R. B., Gore, C. J., Hahn, A. G. et al. (2004): Improved running economy in elite runners after 20 days of simulated moderate-altitude exposure. Journal of applied physiology (Bethesda, Md. : 1985), 96 (3), 931-937. doi: 10.1152/japplphysiol.00725.2003.&lt;br /&gt;
&lt;br /&gt;
Saunders, P. U., Telford, R. D., Pyne, D. B., Hahn, A. G. &amp;amp; Gore, C. J. (2009): Improved running economy and increased hemoglobin mass in elite runners after extended moderate altitude exposure. Journal of science and medicine in sport / Sports Medicine Australia, 12 (1), 67-72. doi: 10.1016/j.jsams.2007.08.014.&lt;br /&gt;
&lt;br /&gt;
Saunders, P. U., Ahlgrim, C., Vallance, B., Green, D. J., Robertson, E. Y., Clark, S. A. et al. (2010): An attempt to quantify the placebo effect from a three-week simulated altitude training camp in elite race walkers. International journal of sports physiology and performance, 5 (4), 521-534.&lt;br /&gt;
&lt;br /&gt;
Saunders, P. U., Pyne, D. B. &amp;amp; Gore, C. J. (2009): Endurance training at altitude. High altitude medicine &amp;amp; biology, 10 (2), 135-148. doi: 10.1089/ham.2008.1092.&lt;br /&gt;
&lt;br /&gt;
Saunders, P. U., Telford, R. D., Pyne, D. D., Gore, C. J. &amp;amp; Hahn, A. G. (2009): Improved race performance in elite middle-distance runners after cumulative altitude exposure. International journal of sports physiology and performance, 4 (1), 134-138.&lt;br /&gt;
&lt;br /&gt;
Sharpe, K., Hopkins, W., Emslie, K. R., Howe, C., Trout, G. J., Kazlauskas, R. et al. (2002): Development of reference ranges in elite athletes for markers of altered erythropoiesis. Haematologica, 87 (12), 1248-1257.&lt;br /&gt;
&lt;br /&gt;
Simons, M., van Es, E. &amp;amp; Hendriksen, I. (2009): Electrically assisted cycling: a new mode for meeting physical activity guidelines? Medicine and science in sports and exercise, 41 (11), 2097-2102. doi: 10.1249/MSS.0b013e3181a6aaa4.&lt;br /&gt;
&lt;br /&gt;
Smith, M. F., Davison, R. C., Balmer, J. &amp;amp; Bird, S. R. (2001): Reliability of mean power recorded during indoor and outdoor self-paced 40 km cycling time-trials. International journal of sports medicine, 22 (4), 270-274. doi: 10.1055/s-2001-13813.&lt;br /&gt;
&lt;br /&gt;
Sparks, S. A., Dove, B., Bridge, C. A., Midgely, A. W. &amp;amp; McNaughton, L. R. (2014): Validity and Reliability of the Look Keo Power Pedal System for Measuring Power Output During Incremental and Repeated Sprint Cycling. International journal of sports physiology and performance. doi: 10.1123/ijspp.2013-0317.&lt;br /&gt;
&lt;br /&gt;
Stapelfeldt, B., Mornieux, G., Oberheim, R., Belli, A. &amp;amp; Gollhofer, A. (2007): Development and evaluation of a new bicycle instrument for measurements of pedal forces and power output in cycling. International journal of sports medicine, 28 (4), 326-332. doi: 10.1055/s-2006-924352.&lt;br /&gt;
&lt;br /&gt;
Stapelfeldt, B., Schwirtz, A., Schumacher, Y. O. &amp;amp; Hillebrecht, M. (2004): Workload demands in mountain bike racing. International journal of sports medicine, 25 (4), 294-300. doi: 10.1055/s-2004-819937.&lt;br /&gt;
&lt;br /&gt;
Tomas, A., Ross, E. Z. &amp;amp; Martin, J. C. (2010): Fatigue during maximal sprint cycling: unique role of cumulative contraction cycles. Medicine and science in sports and exercise, 42 (7), 1364-1369. doi: 10.1249/MSS.0b013e3181cae2ce.&lt;br /&gt;
&lt;br /&gt;
Townsend, N. E., Gore, C. J., Ebert, T. R., Martin, D. T., Hahn, A. G. &amp;amp; Chow, C.-M. (2016): Ventilatory acclimatisation is beneficial for high-intensity exercise at altitude in elite cyclists. European journal of sport science, 1-8. doi: 10.1080/17461391.2016.1139190.&lt;br /&gt;
&lt;br /&gt;
Townsend, N. E., Gore, C. J., Hahn, A. G., Aughey, R. J., Clark, S. A., Kinsman, T. A. et al. (2005): Hypoxic ventilatory response is correlated with increased submaximal exercise ventilation after live high, train low. European journal of applied physiology, 94 (1-2), 207-215. doi: 10.1007/s00421-004-1252-9.&lt;br /&gt;
&lt;br /&gt;
Townsend, N. E., Gore, C. J., Hahn, A. G., McKenna, M. J., Aughey, R. J., Clark, S. A. et al. (2002): Living high-training low increases hypoxic ventilatory response of well-trained endurance athletes. Journal of applied physiology (Bethesda, Md. : 1985), 93 (4), 1498-1505. doi: 10.1152/japplphysiol.00381.2002.&lt;br /&gt;
&lt;br /&gt;
Truijens, M. J., Rodríguez, F. A., Townsend, N. E., Stray-Gundersen, J., Gore, C. J. &amp;amp; Levine, B. D. (2008). The effect of intermittent hypobaric hypoxic exposure and sea level training on submaximal economy in well-trained swimmers and runners. Journal of applied physiology (Bethesda, Md. : 1985), 104 (2), 328-337. doi: 10.1152/japplphysiol.01324.2006.&lt;br /&gt;
&lt;br /&gt;
Vaile, J., Halson, S., Gill, N. &amp;amp; Dawson, B. (2008): Effect of Hydrotherapy on Recovery from Fatigue. International journal of sports medicine, 29 (7), 539-544. doi: 10.1055/s-2007-989267.&lt;br /&gt;
&lt;br /&gt;
van der Woude, L. H. V., Horstman, A., Faas, P., Mechielsen, S., Bafghi, H. A. &amp;amp; Koning, J. J. de. (2008): Power output and metabolic cost of synchronous and asynchronous submaximal and peak level hand cycling on a motor driven treadmill in able-bodied male subjects. Medical engineering &amp;amp; physics, 30 (5), 574-580. doi: 10.1016/j.medengphy.2007.06.006.&lt;br /&gt;
&lt;br /&gt;
Villerius, V., Duc, S. &amp;amp; Grappe, F. (2008): Physiological and Neuromuscular Responses of Competitive Cyclists during a Simulated Self-Paced Interval Training Session. International journal of sports medicine, 29 (09), 770-777. doi: 10.1055/s-2007-989317.&lt;br /&gt;
&lt;br /&gt;
Vogt, S., Roecker, K., Schumacher, Y. O., Pottgiesser, T., Dickhuth, H.-H., Schmid, A. et al. (2008): Cadence-power-relationship during decisive mountain ascents at the Tour de France. International journal of sports medicine, 29 (3), 244-250. doi: 10.1055/s-2007-965353.&lt;br /&gt;
&lt;br /&gt;
Vogt, S., Schumacher, Y. O., Roecker, K., Dickhuth, H.-H., Schoberer, U., Schmid, A. et al. (2007). Power Output during the Tour de France. International journal of sports medicine, 28 (9), 756-761. doi: 10.1055/s-2007-964982.&lt;br /&gt;
&lt;br /&gt;
Vogt, S., Heinrich, L., Schumacher, Y. O., Blum, A., Roecker, K., Dickhuth, H.-H. et al. (2006): Power output during stage racing in professional road cycling. Medicine and science in sports and exercise, 38 (1), 147-151.&lt;br /&gt;
&lt;br /&gt;
Vogt, S., Schumacher, Y. O., Blum, A., Roecker, K., Dickhuth, H.-H., Schmid, A. et al. (2007): Cycling power output produced during flat and mountain stages in the Giro d'Italia: a case study. Journal of sports sciences, 25 (12), 1299-1305. doi: 10.1080/02640410601001632.&lt;br /&gt;
&lt;br /&gt;
Wahl, P., Mathes, S., Köhler, K., Achtzehn, S., Bloch, W. &amp;amp; Mester, J. (2013): Acute Metabolic, Hormonal, and Psychological Responses to Different Endurance Training Protocols. Hormone and Metabolic Research, 45 (11), 827-833. doi: 10.1055/s-0033-1347242.&lt;br /&gt;
&lt;br /&gt;
Wahl, P., Schmidt, A., deMarees, M., Achtzehn, S., Bloch, W. &amp;amp; Mester, J. (2013): Responses of Angiogenic Growth Factors to Exercise, to Hypoxia and to Exercise under Hypoxic Conditions. International journal of sports medicine, 34 (02), 95-100. doi: 10.1055/s-0032-1314815.&lt;br /&gt;
&lt;br /&gt;
Wiedemann, M. S. F. &amp;amp; Bosquet, L. (2010): Anaerobic Work Capacity Derived from Isokinetic and Isoinertial Cycling. International journal of sports medicine, 31 (02), 89-94. doi: 10.1055/s-0029-1233466.&lt;br /&gt;
&lt;br /&gt;
Wilson, M. G., Lane, A. M., Beedie, C. J. &amp;amp; Farooq, A. (2012): Influence of accurate and inaccurate 'split-time' feedback upon 10-mile time trial cycling performance. European journal of applied physiology, 112 (1), 231-236. doi: 10.1007/s00421-011-1977-1.&lt;br /&gt;
&lt;br /&gt;
Wu, S. S. X., Peiffer, J. J., Brisswalter, J., Nosaka, K., Lau, W. Y. &amp;amp; Abbiss, C. R. (2015): Pacing strategies during the swim, cycle and run disciplines of sprint, Olympic and half-Ironman triathlons. European journal of applied physiology, 115 (5), 1147-1154. doi: 10.1007/s00421-014-3096-2.&lt;br /&gt;
&lt;br /&gt;
    Glossary&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
(In der folgenden Tabelle finden Sie aktuelle internationale Literaturstellen in denen das SRM - Ergometer und / oder die SRM - Trainingssysteme für wissenschaftliche Untersuchungen eingesetzt wurden.&lt;br /&gt;
[[Media:Scientific Publications SRM 2013.pdf|Hier]] finden sie die internationalen Literaturstellen in einem pfd - Dokument zusammengefasst.)&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot;&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|- class=&amp;quot;hintergrundfarbe6&amp;quot;&lt;br /&gt;
!style=&amp;quot;width:30%&amp;quot;| Autor!! style=&amp;quot;width:30%&amp;quot; | Titel!! style=&amp;quot;width:30%&amp;quot; | Publikation&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Abbiss, C.R.; Quod, M.J.; Martin, David T.; Netto, K.J.; Nosaka, K.; Lee, H. et al. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Dynamic pacing strategies during the cycle phase of an Ironman triathlon.  &lt;br /&gt;
|style=&amp;quot;vertical-align:top&amp;quot;| Med Sci Sports Exerc 38 (4), S. 726–734&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Abbiss, C.R.; Quod, M.J.; Levin, G.; Martin, D.T.; Laursen, P.B. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Accuracy of the Velotron ergometer and SRM power meter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 30 (2), S. 107–112.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Abel, T.; Burkett, B.; Schneider, S.; Lindschulten, R.; Strüder, H. K. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The exercise profile of an ultra-long handcycling race: the Styrkeprøven experience.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Spinal Cord 48 (12), S. 894–898.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Antonutto, G.; Capelli, C.; Girardis, M.; Zamparo, P.; di Prampero P.E. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of microgravity on maximal power of lower limbs during very short efforts in humans.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Physiol 86(1), S. 85-92.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Arkesteijn, M.; Hopker, J.; Jobson, S.; Passfield, L. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The Effect of Turbo Trainer Cycling on Pedalling Technique and Cycling Efficiency.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 34 (06), S. 520–525&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M. J.; Gore, C. J.; Burge, C. M.; Clough, M. L.; Bourdon, P. C.; Dobson, G. P.; Hahn, A. G. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Skin-prick blood samples are reliable for estimating Hb mass with the CO-dilution technique.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 79 (6), S. 535–537.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M. J.; Gore, C. J.; Dobson, G. P.; Boston, T. T.; Parisotto, R.; Emslie, K. R. et al. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Simulated moderate altitude elevates serum erythropoietin but does not increase reticulocyte production in well-trained runners.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 81 (5), S. 428–435&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Gore, C. J.; Dobson, G. P.; Hahn, A. G. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| &amp;quot;Live high, train low&amp;quot; does not change the total haemoglobin mass of male endurance athletes sleeping at a simulated altitude of 3000 m for 23 nights. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 80 (5), S. 479–484.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Gore, C. J.; Martin, D. T.; Dobson, G. P.; Hahn, A. G. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of a 12-day &amp;quot;live high, train low&amp;quot; camp on reticulocyte production and haemoglobin mass in elite female road cyclists.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 80 (5), S. 472–478.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Hahn, A. G.; Martin, D. T.; Logan, P.; Parisotto, R.; Gore, C. J. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| A comparison of the physiological response to simulated altitude exposure and r-HuEpo administration.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 19 (11), S. 831–837&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Gore, C.J.; Parisotto, R.; Sharpe, K.; Hopkins, W.G.; Hahn, A.G. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effect of altitude on second-generation blood tests to detect erythropoietin abuse by athletes.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Haematologica 88 (9), S. 1053–1062&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Aughey, R. J.; Clark, S. A.; Gore, C. J.; Townsend, N. E.; Hahn, A. G.; Kinsman, T. A. et al. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Interspersed normoxia during live high, train low interventions reverses an early reduction in muscle Na+, K +ATPase activity in well-trained athletes.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 98 (3), S. 299–309&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Aughey, R. J.; Gore, C. J.; Hahn, A. G.; Garnham, A. P.; Clark, S. A.; Petersen, A. C. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Chronic intermittent hypoxia and incremental cycling exercise independently depress muscle in vitro maximal Na+-K+-ATPase activity in well-trained athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 98 (1), S. 186–192&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashman, S.B.; Monk, T.H.; Kupfer, D.J.; Clark, C.H.; Myers, F.S.; Frank, E.; Leibenluft (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Relationship between social rhythms and mood in patients with rapid cycling bipolar disorder.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Psychiatry Res 86 (1), S. 1–8&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Austin, N.; Nilwik, R.; Herzog, W. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| In vivo operational fascicle lengths of vastus lateralis during submaximal and maximal cycling.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Biomech 43 (12), S. 2394–2399&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Balmer, J.; Bird, S.; Davison, R.C.R.; Doherty, M.; Smith, P. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Mechanically braked Wingate powers: agreement between SRM, corrected and conventional methods of measurement.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 22 (7), S. 661–667&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Bird, S.; Davison, R.; Lucia, A. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effect of age on 16.1-km time-trial performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 26 (2), S. 197–206&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Davison, R.C.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Peak power predicts performance power during an outdoor 16.1-km cycling time trial.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 32 (8), S. 1485–1490&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Balmer, J.; Davison, R.C.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reliability of an air-braked ergometer to record peak power during a maximal cycling test.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 32 (10), S. 1790–1793&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Davison, R.C.; Coleman, D.A.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The validity of power output recorded during exercise performance tests using a Kingcycle air-braked cycle ergometer when compared with an SRM powermeter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 21 (3), S. 195–199&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bassett, D.R.; Kyle, C. R.; Passfield, L.; Broker, J.P.; Burke, E.R. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Comparing cycling world hour records, 1967-1996: modeling with empirical data.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 31 (11), S. 1665–1676&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bentley, D. J.; McNaughton, L. R.; Thompson, D.; Vleck, V. E.; Batterham, A. M. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Peak power output, the lactate threshold, and time trial performance in cyclists. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 33 (12), S. 2077–2081&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Crequy, S.; Chiementin, X. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and Reliability of the G-Cog BMX Powermeter.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Bertucci, W.; Duc, S.; Villerius, V.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of the Axiom PowerTrain cycle ergometer when compared with an SRM powermeter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (1), S. 59–65&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Duc, S.; Villerius, V.; Pernin, J. N.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and reliability of the PowerTap mobile cycling powermeter when compared with the SRM Device.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (10), S. 868–873&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Grappe, F.; Girard, A.; Betik, A.; Rouillon, J.D. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects on the crank torque profile when changing pedalling cadence in level ground and uphill road cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Biomech 38 (5), S. 1003–1010&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Grappe, F.; Groslambert, A. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Laboratory versus outdoor cycling conditions: differences in pedaling biomechanics. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Biomech 23 (2), S. 87–92&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Taiar, R.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Differences between sprint tests under laboratory and actual cycling conditions. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Med Phys Fitness 45 (3), S. 277–283&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Billaut, François; Gore, Christopher J.; Aughey, Robert J. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Enhancing team-sport athlete performance: is altitude training relevant?&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 42 (9), S. 751–767&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Brickley, G.; Dekerle, J.; Hammond, A.; Pringle, J.; Carter, H. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Assessment of Maximal Aerobic Power and Critical Power in a Single 90-s Isokinetic All-Out Cycling Test.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 28 (5), S. 414–419&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Broker, J.P.; Kyle, C.R.; Burke, E.R. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Racing cyclist power requirements in the 4000-m individual and team pursuits.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 31 (11), S. 1677–1685&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Brosnan, M. J.; Martin, D. T.; Hahn, A. G.; Gore, C. J.; Hawley, J. A. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Impaired interval exercise responses in elite female cyclists at moderate simulated altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 89 (5), S. 1819–1824&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Cangley, P.; Passfield, L.; Carter, H.; Bailey, M. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The Effect of Variable Gradients on Pacing in Cycling Time-Trials.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 32 (02), S. 132–136&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Carpes, F.P.; Rossato, M.; Faria, I.E.; Bolli Mota, C. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Bilateral pedaling asymmetry during a simulated 40-km cycling timetrial.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Med Phys Fitness 47 (1), S. 51–57&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Clark, Sally A.; Bourdon, P. C.; Schmidt, W.; Singh, B.; Cable, G.; Onus, K. J. et al. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The effect of acute simulated moderate altitude on power, performance and pacing strategies in well-trained cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 102 (1), S. 45–55&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Clark, Sally A.; Quod, M. J.; Clark, M. A.; Martin, D. T.; Saunders, P. U.; Gore, C. J. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Time course of haemoglobin mass during 21 days live high:train low simulated altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 106 (3), S. 399–406&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Clark, S.K.; Johnson, Thomas M. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Selenium stable isotope investigation into selenium biogeochemical cycling in a lacustrine environment: Sweitzer Lake, Colorado.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Environ. Qual. 39 (6), S. 2200–2210&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Coleman, D.A.; Wiles, J.D.; Nunn, M.; Smith, M.F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reliability of sprint test indices in well-trained cyclists. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (5), S. 383–387&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Doherty, M.; Balmer, J.; Davison, R.C.R.; Robinson, L.; Smith, P.M. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reliability of a combined 3-min constant load and performance cycling test.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 24 (5), S. 366–371&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Duc, S.; Betik, A-C; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| EMG activity does not change during a time trial in competitive cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (2), S. 145–150&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Duc, S.; Villerius, V.; Bertucci, W.; Pernin, J.N.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Muscular activity level during pedalling is not affected by crank inertial load.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 95 (2-3), S. 260–264&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Duc, S.; Villerius, V.; Bertucci, W.; Grappe, F. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and reproducibility of the ErgomoPro power meter compared with the SRM and Powertap power meters.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 2 (3), S. 270–281&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Eastwood, A.; Sharpe, K.; Bourdon, P.C.; Woolford, S.M.; Saunders, P.U.; Robertson, E.Y. et al. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Within-subject variation in hemoglobin mass in elite athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 44 (4), S. 725–732&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Ebert, T.R.; Martin, D.T.; McDonald, W.; Victor, J.; Plummer, J.; Withers, R.T. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Power output during women's World Cup road cycle racing.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 95 (5-6), S. 529–536&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ebert, T.R.; Martin, D.T.; Stephens, B.; Withers, R.T. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Power output during a professional men's road-cycling tour.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 1 (4), S. 324–335&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Emonson, D. L.; Aminuddin, A. H.; Wight, R. L.; Scroop, G. C.; Gore, C. J. (1997)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Training-induced increases in sea level VO2max and endurance are not enhanced by acute hypobaric exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 76 (1), S. 8–12&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Faiss, R.; Praz, M.; Meichtry, A.; Gobelet, C.; Deriaz, O. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The effect of mountain bike suspensions on vibrations and off-road uphill performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Med Phys Fitness 47 (2), S. 151–158&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Fu, Qi; Townsend, N.E.; Shiller, S.M.; Martini, E.R.; Okazaki, K.; Shibata, S. et al. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Intermittent hypobaric hypoxia exposure does not cause sustained alterations in autonomic control of blood pressure in young athletes. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Am. J. Physiol. Regul. Integr. Comp. Physiol. 292 (5), S. R1977-84&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gardner, A.S.; Martin, J.C.; Martin, D.T.; Barras, M.; Jenkins, D.G. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Maximal torque- and power-pedaling rate relationships for elite sprint cyclists in laboratory and field tests. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 101 (3), S. 287–292&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gardner, A.S.; Martin, D.T.; Jenkins, D.G.; Dyer, I.; van Eiden, J.; Barras, M.; Martinm, J.C. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Velocity-specific fatigue: quantifying fatigue during variable velocity cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Med Sci Sports Exerc 41 (4), S. 904–911&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gardner, A.S.; Stephens, S.; Martin, D.T.; Lawton, E.; Lee, H.; Jenkins, D. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Accuracy of SRM and power tap power monitoring systems for bicycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 36 (7), S. 1252–1258&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Garvican, L.A.; Hammond, K.; Varley, Matthew C.; Gore, C.J.; Billaut, F.; Aughey, R.J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Lower Running Performance and Exacerbated Fatigue in Soccer Played at 1600 m. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Garvican, L.A.; Martin, D.T.; Clark, S.A.; Schmidt, W.F.; Gore, C.J. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Variability of erythropoietin response to sleeping at simulated altitude: a cycling case study. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 2 (3), S. 327–331.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Garvican, L.A.; Pottgiesser, T.; Martin, D.T.; Schumacher, Y.O.; Barras, M.; Gore, C.J. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The contribution of haemoglobin mass to increases in cycling performance induced by simulated LHTL. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 111 (6), S. 1089–1101&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Garvican, L.A.; Saunders, P.U.; Pyne, D.B.; Martin, D.T.; Robertson, E.Y.; Gore, C.J. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Hemoglobin mass response to simulated hypoxia &amp;quot;blinded&amp;quot; by noisy measurement? &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 112 (10), S. 1797-8; author reply 1799&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Giacomoni, M.; Billaut, F.; Falgairette, G. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effects of the Time of Day on Repeated All-Out Cycle Performance and Short-Term Recovery Patterns. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 27 (6), S. 468–474&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| González-Haro, C.; Galilea B., P.A.; Soria, M.; Drobnic, F.; Escanero, J.F. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Comparison of nine theoretical models for estimating the mechanical power output in cycling. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Br J Sports Med 41 (8), S. 506-9; discussion 509&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| González-Haro, C.; Galilea, P.A.; Escanero, J.F. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Comparison of different theoretical models estimating peak power output and maximal oxygen uptake in trained and elite triathletes and endurance cyclists in the velodrome. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Sci 26 (6), S. 591–601&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Goosey-Tolfrey, V.; Castle, P.; Webborn, N.; Abel, T. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Aerobic capacity and peak power output of elite quadriplegic games players.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Br J Sports Med 40 (8), S. 684–687&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gordon, R.S.; Franklin, K.L.; Davies, B.; Baker, J.S. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Further mechanical considerations between polar and SRM mobile ergometer systems during laboratory-based high-intensity, intermittent cycling activity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Res Sports Med 15 (4), S. 241–247&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, Christopher John; Clark, Sally A.; Saunders, Philo U. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Nonhematological mechanisms of improved sea-level performance after hypoxic exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 39 (9), S. 1600–1609&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A. G.; Aughey, R. J.; Martin, D. T.; Ashenden, M. J.; Clark, S. A. et al. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Live high:train low increases muscle buffer capacity and submaximal cycling efficiency.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Acta Physiol. Scand. 173 (3), S. 275–286&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A. G.; Burge, C. M.; Telford, R. D. (1997)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| VO2max and haemoglobin mass of trained athletes during high intensity training.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 18 (6), S. 477–482&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore C.J.; Hahn A.G.; Scroop G.C.; Watson D.B.; Norton K.I.; Wood R.J.; Campbell D.P. (1996 )&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Increased arterial desaturation in trained cyclists during maximal exercise at 580 m altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Physiol 80(6), S. 2204-10&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A.; Rice, A.; Bourdon, P.; Lawrence, S.; Walsh, C. et al. (1998)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Altitude training at 2690m does not increase total haemoglobin mass or sea level VO2max in world champion track cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 1 (3), S. 156–170&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A. G. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Letter to the editors - Re: Heinicke K, Heinicke I, Schmidt W, Wolfarth B. A three-week traditional altitude training increases hemoglobin mass and red cell volume in elite biathlon athletes. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (6), S. 504-5; author reply 506-7&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore C.J.; Little S.C.; Hahn A.G.; Scroop G.C.; Norton K.I.; Bourdon P.C.; Woolford (1997)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reduced performance of male and female athletes at 580 m altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 75(2), S. 136-43&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; McSharry, P. E.; Hewitt, A. J.; Saunders, P. U. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Preparation for football competition at moderate to high altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Scand J Med Sci Sports 18 Suppl 1, S. 85–95&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, Christopher J.; Rodríguez, Ferran A.; Truijens, Martin J.; Townsend, Nathan E.; Stray-Gundersen, James; Levine, Benjamin D. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Increased serum erythropoietin but not red cell production after 4 wk of intermittent hypobaric hypoxia (4,000-5,500 m).&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 101 (5), S. 1386–1393&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gough, C. E.; Sharpe, K.; Garvican, L. A.; Anson, J. M.; Saunders, P. U.; Gore, C. J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The effects of injury and illness on haemoglobin mass.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 34 (9), S. 763–769&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gough, C.E.; Saunders, P.U.; Fowlie, J.; Savage, B.; Pyne, D.B.; Anson, J.M. et al. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Influence of altitude training modality on performance and total haemoglobin mass in elite swimmers.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 112 (9), S. 3275–3285&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Groslambert, A.; Grappe, F.; Bertucci, W.; Perrey, S.; Girard, A.J.; Rouillon, J.D. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| A perceptive individual time trial performed by triathletes to estimate the anaerobic threshold. A preliminary study.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Med Phys Fitness 44 (2), S. 147–156&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Haakonssen, Eric C.; Martin, David T.; Burke, Louise M.; Jenkins, David G. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Energy expenditure of constant- and variable-intensity cycling: power meter estimates. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 45 (9), S. 1833–1840&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hahn, A. G.; Gore, C. J. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The effect of altitude on cycling performance: a challenge to traditional concepts. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 31 (7), S. 533–557&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hahn, A. G.; Gore, C. J.; Martin, D. T.; Ashenden, M. J.; Roberts, A. D.; Logan, P. A. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Hahn, A. G.; Gore, C. J.; Martin, D. T.; Ashenden, M. J.; Roberts, A. D.; Logan, P. A. (2001) &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Comp. Biochem. Physiol., Part A Mol. Integr. Physiol. 128 (4), S. 777–789&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hajoglou, A.; Foster, C.; Koning, J.J. de; Lucia, A.; Kernozek, T.W.; Porcari, J.P. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effect of warm-up on cycle time trial performance. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 37 (9), S. 1608–1614&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Hopker, J.; Myers, S.; Jobson, S.A.; Bruce, W.; Passfield, L. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of the Wattbike cycle ergometer&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 31 (10), S. 731–736&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Hurst, H.T.; Atkins, S. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Agreement between polar and SRM mobile ergometer systems during laboratory-based high-intensity, intermittent cycling activity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 24 (8), S. 863–868&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hurst, H.T.; Atkins, S. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Power output of field-based downhill mountain biking.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 24 (10), S. 1047–1053&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Davison, R.C.; Coleman, D.A.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The validity of power output recorded during exercise performance tests using a Kingcycle air-braked cycle ergometer when compared with an SRM powermeter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 21 (3), S. 195–199&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Jobson, S.A.; Passfield, L.; Atkinson, G.; Barton, G.; Scarf, P. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The analysis and utilization of cycling training data.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 39 (10), S. 833–844&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Jobson, S.; Woodside, J.; Passfield, L.; Nevill, A. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Allometric Scaling of Uphill Cycling Performance. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (09), S. 753–757&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Joch, W.; Ückert, S. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of Whole Body Cooling of - 110 °C on the Heart Frequency in Endurance Activity and in Resting Time. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| W. Phys Rehab Kur Med  14(3), S. 146-150&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Julian, Colleen G.; Gore, Christopher J.; Wilber, Randall L.; Daniels, Jack T.; Fredericson, Michael; Stray-Gundersen, James et al. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Intermittent normobaric hypoxia does not alter performance or erythropoietic markers in highly trained distance runners.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 96 (5), S. 1800–1807&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Karsten, B.; Jobson, S.A.; Hopker, J.; Passfield, L., Beedie, C. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The 3-min Test Does not Provide a Valid Measure of Critical Power Using the SRM Isokinetic Mode.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med. Sep 10. [Epub ahead of print]&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, T. A.; Gore, C. J.; Hahn, A. G.; Hopkins, W. G.; Hawley, J. A.; McKenna, M. J. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sleep in athletes undertaking protocols of exposure to nocturnal simulated altitude at 2650 m.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 8 (2), S. 222–232&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, T. A.; Hahn, A. G.; Gore, C. J.; Martin, D. T.; Chow, C. M. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sleep quality responses to atmospheric variation: case studies of two elite female cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 6 (4), S. 436–442&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, Tahnee A.; Hahn, Allan G.; Gore, Christopher J.; Wilsmore, Bradley R.; Martin, David T.; Chow, Chin-Moi (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Respiratory events and periodic breathing in cyclists sleeping at 2,650-m simulated altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 92 (5), S. 2114–2118&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, Tahnee A.; Townsend, Nathan E.; Gore, Christopher J.; Hahn, Allan G.; Clark, Sally A.; Aughey, Robert J. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sleep disturbance at simulated altitude indicated by stratified respiratory disturbance index but not hypoxic ventilatory response.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 94 (5-6), S. 569–575&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kirkland, A.; Coleman, D.; Wiles, J.D.; Hopker, J. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of the Ergomopro powermeter.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (11), S. 913–916&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Loughlin, A.F.; Skiles, G.L.; Alberts, D.W.; Schaefer, W.H. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| An ion exchange liquid chromatography/mass spectrometry method for the determination of reduced and oxidized glutathione and glutathione conjugates in hepatocytes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Pharm Biomed Anal 26 (1), S. 131–142&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|MacIntosh, B.R.; Svedahl, K.; Kim, M. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Fatigue and optimal conditions for short-term work capacity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 92 (4-5), S. 369–375&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|MacRae HS-H; Hise, K.J.; Allen, P.J. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of front and dual suspension mountain bike systems on uphill cycling performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 32 (7), S. 1276–1280&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Mc Naughton, L.R.; Sherman, R.; Roberts, S.; Bentley, D.J. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Portable gas analyser Cosmed K4b2 compared to a laboratory based mass spectrometer system.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Med Phys Fitness 45 (3), S. 315–323&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| McDaniel, J.; Subudhi, A.; Martin, J.C. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Torso stabilization reduces the metabolic cost of producing cycling power.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Can J Appl Physiol 30 (4), S. 433–441&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|McLean, Blake D.; Buttifant, David; Gore, Christopher J.; White, Kevin; Liess, Carsten; Kemp, Justin (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Physiological and performance responses to a preseason altitude-training camp in elite team-sport athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 8 (4), S. 391–399&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Meyer, T.; Gabriel, H.H.W.; Auracher, M.; Scharhag, J.; Kindermann, W. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Metabolic profile of 4 h cycling in the field with varying amounts of carbohydrate supply.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 88 (4-5), S. 431–437&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Mijnarends, D.M.; Meijers, J.M.M.; Halfens, R.J.G.; Ter Borg, S.; Luiking, Y.C.; Verlaan, S. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of tools to measure muscle mass, strength, and physical performance in community-dwelling older people: a systematic review.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Am Med Dir Assoc 14 (3), S. 170–178&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Millet, G.P.; Tronche, C.; Fuster, N.; Candau, R. (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Level ground and uphill cycling efficiency in seated and standing positions.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Med Sci Sports Exerc 34 (10), S. 1645–1652&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Millet, G.P.; Tronche, C.; Fuster, N.; Bentley, D.J.; Candau, R. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and reliability of the Polar S710 mobile cycling powermeter.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 24 (3), S. 156–161&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Mornieux, G.; Gollhofer, A.; Stapelfeldt, B. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Muscle Coordination while Pulling up During Cycling. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 31 (12), S. 843–846&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Mornieux, G.; Stapelfeldt, B.; Gollhofer, A.; Belli, A. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effects of Pedal Type and Pull-Up Action during Cycling. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (10), S. 817–822&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Neville, V.; Pain, M.T.G.; Folland, J.P. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Aerobic power and peak power of elite America's Cup sailors. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 106 (1), S. 149–157&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Neville, V.; Pain, M.T.G.; Kantor, J.; Folland, J.P. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Influence of crank length and crank-axle height on standing armcrank (grinding) power.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 42 (2), S. 381–387&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Neville, V.; Zaher, N.; Pain, M.T.G.; Folland, J.P. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Lower limb influence on standing arm-cranking ('grinding').&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 30 (10), S. 713–718&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Neya, Mitsuo; Enoki, Taisuke; Ohiwa, Nao; Kawahara, Takashi; Gore, Christopher J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Increased hemoglobin mass and VO2max with 10 h nightly simulated altitude at 3000 m.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 8 (4), S. 366–372&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Nimmerichter, A.; Eston, R.G.; Bachl, N.; Williams, C. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Longitudinal monitoring of power output and heart rate profiles in elite cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 29 (8), S. 831–840&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Nimmerichter, A.; Williams, C.; Bachl, N.; Eston, R. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Evaluation of a field test to assess performance in elite cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 31 (3), S. 160–166&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|O’Hara, J.; Thomas, A.; Seims, A.; Cooke, C.; King, R.F.G (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reliability of a High-Intensity Endurance Cycling Test.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 33 (01), S. 18–25&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Parisotto, R.; Gore, C. J.; Hahn, A. G.; Ashenden, M. J.; Olds, T. S.; Martin, D. T. et al. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reticulocyte parameters as potential discriminators of recombinant human erythropoietin abuse in elite athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 21 (7), S. 471–479&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Paton, C.D.; Hopkins, W.G. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Tests of cycling performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 31 (7), S. 489–496&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Paton, C.D.; Hopkins, W.G. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Ergometer error and biological variation in power output in a performance test with three cycle ergometers.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 27 (6), S. 444–447&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Caillaud, C.; Thompson, M.W. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Central and Peripheral Fatigue during Passive and Exercise-Induced Hyperthermia &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med. Sci. Sports Exerc. 43 (9), S. 1657 – 1665&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Caillaud, C.; Thompson, M.W. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The role of aerobic fitness and exercise intensity on endurance performance in uncompensable heat stress conditions. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol  112, S. 1989 - 1999&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Cramer, M.N.; Chapman, P.G.; Caillaud, C.; Thompson, M.W. (2011)  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Cardiovascular strain impairs prolonged self-paced exercise in the heat. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Exp Physiol 96 (2), S. 134 - 144&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Cramer, M.N.; Chapman, P.G.; Caillaud, C.; Thompson, M.W. (2011)   &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Neuromuscular function following prolonged intense self-paced exercise in hot climatic conditions. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Physiol. 111, S. 1561 – 1569&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Perrey, S.; Grappe, F.; Girard, A.; Bringard, A.; Groslambert, A.; Bertucci, W.; Rouillon, J.D. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Physiological and metabolic responses of triathletes to a simulated 30-min time-trial in cycling at self-selected intensity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 24 (2), S. 138–143&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Pester, M.; Knorr, K.-H.; Friedrich, M.W.; Wagner, M.; Loy, A. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sulfate-reducing microorganisms in wetlands - fameless actors in carbon cycling and climate change.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Front Microbiol 3, S. 72&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Pinot, J.; Grappe, F. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The record power profile to assess performance in elite cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 32 (11), S. 839–844&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Pottgiesser, Torben; Garvican, Laura A.; Martin, David T.; Featonby, Jesse M.; Gore, Christopher J.; Schumacher, Yorck O. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Short-term hematological effects upon completion of a four-week simulated altitude camp.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Physiol Perform 7 (1), S. 79–83&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Quod, M. J.; Martin, D. T.; Martin, J. C.; Laursen, P. B. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The Power Profile Predicts Road Cycling MMP.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 31 (06), S. 397–401&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Reiser, M.; Meyer, T.; Kindermann, W.; Daugs, R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Transferability of workload measurements between three different types of ergometer.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 82 (3), S. 245–249&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Reiser, R.; Hart, C. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Cycling on Rollers: Kreitler Fan Resistance at Submaximal Levels of Effort.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (3), S. 212–216&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Richalet, J-P; Gore, C. J. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Live and/or sleep high:train low, using normobaric hypoxia.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Scand J Med Sci Sports 18 Suppl 1, S. 29–37&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Roberts, A. D.; Clark, S. A.; Townsend, N. E.; Anderson, M. E.; Gore, C. J.; Hahn, A. G. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Changes in performance, maximal oxygen uptake and maximal accumulated oxygen deficit after 5, 10 and 15 days of live high:train low altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 88 (4-5), S. 390–395&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Robertson, E.Y.; Saunders, P.U.; Pyne, D.B.; Aughey, R.J.; Anson, J.M.; Gore, C.J. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reproducibility of performance changes to simulated live high/train low altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 42 (2), S. 394–401&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Robertson, E.Y.; Saunders, P.U.; Pyne, D.B.; Gore, C.J.; Anson, J.M. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effectiveness of intermittent training in hypoxia combined with live high/train low.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| . J. Appl. Physiol. 110 (2), S. 379–387&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Rodríguez, F.A.; Truijens, M.J.; Townsend, N.E.; Stray-Gundersen, J.; Gore, C.J.; Levine, B.D. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Performance of runners and swimmers after four weeks of intermittent hypobaric hypoxic exposure plus sea level training.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 103 (5), S. 1523–1535&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Sassi, A.; Rampinini, E.; Martin, D.T.; Morelli, A. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of gradient and speed on freely chosen cadence: the key role of crank inertial load.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Biomech 42 (2), S. 171–177&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P. U.; Telford, R. D.; Pyne, D. B.; Cunningham, R. B.; Gore, C. J.; Hahn, A. G.; Hawley, J. A. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Improved running economy in elite runners after 20 days of simulated moderate-altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 96 (3), S. 931–937&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P. U.; Telford, R. D.; Pyne, D. B.; Hahn, A. G.; Gore, C. J. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Improved running economy and increased hemoglobin mass in elite runners after extended moderate altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 12 (1), S. 67–72&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P.U.; Ahlgrim, C.; Vallance, B.; Green, D.J.; Robertson, E.Y.; Clark, S.A. et al. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| An attempt to quantify the placebo effect from a three-week simulated altitude training camp in elite race walkers.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 5 (4), S. 521–534&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P.U.; Pyne, David B.; Gore, C.J. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Endurance training at altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| High Alt. Med. Biol. 10 (2), S. 135–148&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P.U.; Telford, R.D.; Pyne, D.D.; Gore, C.J.; Hahn, A.G. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Improved race performance in elite middle-distance runners after cumulative altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 4 (1), S. 134–138&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Sharpe, K.; Hopkins, W.; Emslie, K.R.; Howe, C.; Trout, G.J.; Kazlauskas, R. et al. (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Development of reference ranges in elite athletes for markers of altered erythropoiesis.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Haematologica 87 (12), S. 1248–1257&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Simons, M.; van Es, E.; Hendriksen, I. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Electrically assisted cycling: a new mode for meeting physical activity guidelines?&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 41 (11), S. 2097–2102&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Smith, M.F.; Davison, R.C.; Balmer, J.; Bird, S.R. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reliability of mean power recorded during indoor and outdoor selfpaced 40 km cycling time-trials.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 22 (4), S. 270–274&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Stapelfeldt, B.; Mornieux, G.; Oberheim, R.; Belli, A.; Gollhofer, A. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Development and evaluation of a new bicycle instrument for measurements of pedal forces and power output in cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 28 (4), S. 326–332&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Stapelfeldt, B.; Schwirtz, A.; Schumacher, Y.O.; Hillebrecht, M. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Workload demands in mountain bike racing.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 25 (4), S. 294–300&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Tomas, A.; Ross, E.Z.; Martin, J.C. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Fatigue during maximal sprint cycling: unique role of cumulative contraction cycles.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 42 (7), S. 1364–1369&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Townsend, N.E.; Gore, C.J.; Hahn, A.G.; Aughey, R.J.; Clark, S.A.; Kinsman, T.A. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Hypoxic ventilatory response is correlated with increased submaximal exercise ventilation after live high, train low.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 94 (1-2), S. 207–215&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Townsend, N.E.; Gore, C.J.; Hahn, A.G.; McKenna, M.J.; Aughey, R.J.; Clark, S.A. et al. (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Living high-training low increases hypoxic ventilatory response of well-trained endurance athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 93 (4), S. 1498–1505&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Truijens, M.J.; Rodríguez, F.A.; Townsend, N.E.; Stray-Gundersen, J.; Gore, C.J.; Levine, B.D. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The effect of intermittent hypobaric hypoxic exposure and sea level training on submaximal economy in well-trained swimmers and runners.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 104 (2), S. 328–337&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Vaile, J.; Halson, S.; Gill, N.; Dawson, B. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effect of Hydrotherapy on Recovery from Fatigue.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 29 (7), S. 539–544&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| van der Woude, L.H.V.; Horstman, A.; Faas, P.; Mechielsen, S.; Bafghi, H.A.; Koning, J.J. de (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Power output and metabolic cost of synchronous and asynchronous submaximal and peak level hand cycling on a motor driven treadmill in able-bodied male subjects.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Med Eng Phys 30 (5), S. 574–580&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Villerius, V.; Duc, S.; Grappe, F. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Physiological and Neuromuscular Responses of Competitive Cyclists during a Simulated Self-Paced Interval Training Session.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (09), S. 770–777&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Vogt, S.; Heinrich, L.; Schumacher, Y. O.; Blum, A.; Roecker, K.; Dickhuth, H.-H.; Schmid, A. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Power output during stage racing in professional road cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 38 (1), S. 147–151&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Vogt, S.; Roecker, K.; Schumacher, Y. O.; Pottgiesser, T.; Dickhuth, H-H; Schmid, A.; Heinrich, L. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Cadence-power-relationship during decisive mountain ascents at the Tour de France.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 29 (3), S. 244–250&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Vogt, S.; Schumacher, Y.O.; Blum, A.; Roecker, K.; Dickhuth, H.-H.; Schmid, A.; Heinrich, L. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Cycling power output produced during flat and mountain stages in the Giro d'Italia: a case study.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Sci 25 (12), S. 1299–1305&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Vogt, S.; Schumacher, Y. O.; Roecker, K.; Dickhuth, H-H; Schoberer, U.; Schmid, A.; Heinrich, L. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Power Output during the Tour de France.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 28 (9), S. 756–761&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wahl, P.; Mathes, S.; Köhler, K.; Achtzehn, S.; Bloch, W.; Mester, J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Acute Metabolic, Hormonal, and Psychological Responses to Different Endurance Training Protocols.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Horm Metab Res 45 (11), S. 827–833&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wahl, P.; Schmidt, A.; deMarees, M.; Achtzehn, S.; Bloch, W.; Mester, J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Responses of Angiogenic Growth Factors to Exercise, to Hypoxia and to Exercise under Hypoxic Conditions.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 34 (02), S. 95–100&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wiedemann, M. S. F.; Bosquet, L. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Anaerobic Work Capacity Derived from Isokinetic and Isoinertial Cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 31 (02), S. 89–94&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wilson, M.G.; Lane, A.M.; Beedie, C.J.; Farooq, A. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Influence of accurate and inaccurate 'split-time' feedback upon 10-mile time trial cycling performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 112 (1), S. 231–236&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wooles, A.L.; Robinson, A.J.; Keen, P.S. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|A Static Method for Obtaining a Calibration Factor for SRM Bicycle Power Cranks.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sports Engineering 8 (3), S. 137-144&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=File:SRM_Scientific_Publications_06-2016.pdf&amp;diff=2011</id>
		<title>File:SRM Scientific Publications 06-2016.pdf</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=File:SRM_Scientific_Publications_06-2016.pdf&amp;diff=2011"/>
				<updated>2016-06-29T08:36:34Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Internationale_Literatur_zum_SRM-Ergometer&amp;diff=2010</id>
		<title>Internationale Literatur zum SRM-Ergometer</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Internationale_Literatur_zum_SRM-Ergometer&amp;diff=2010"/>
				<updated>2016-06-29T08:35:44Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{languages&lt;br /&gt;
|de=Internationale Literatur zum SRM-Ergometer&lt;br /&gt;
|en=International publications on the SRM Ergometer&lt;br /&gt;
|cn=International publications on the SRM Ergometer&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
In der folgenden Tabelle sind  diverese Sammlungen an Publikationen zu verschiedenen Themen als PDF-Dateien verlinkt.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot;&lt;br /&gt;
|+ style=&amp;quot;padding-bottom:1em&amp;quot; | Publikationen des SRM-Ergometers &lt;br /&gt;
|- class=&amp;quot;hintergrundfarbe6&amp;quot;&lt;br /&gt;
!style=&amp;quot;width:60%&amp;quot;| Publikationen!! style=&amp;quot;width:30%&amp;quot;| Letztes Update&lt;br /&gt;
|-&lt;br /&gt;
| [[Media:SRM_Scientific_Publications_06-2016.pdf|SRM Scientific Publications]]&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| Juni 2016 &lt;br /&gt;
|-&lt;br /&gt;
| [[Media:Torque_publications_2015.pdf|Torque Publications]]&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| Januar 2015&lt;br /&gt;
|-&lt;br /&gt;
| [[Media:Eccentric_Chainrings_2015.pdf|Eccentric Chainrings Publications]]&lt;br /&gt;
|style=&amp;quot;text-align:right&amp;quot;| April 2015&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
(In der folgenden Tabelle finden Sie aktuelle internationale Literaturstellen in denen das SRM - Ergometer und / oder die SRM - Trainingssysteme für wissenschaftliche Untersuchungen eingesetzt wurden.&lt;br /&gt;
[[Media:Scientific Publications SRM 2013.pdf|Hier]] finden sie die internationalen Literaturstellen in einem pfd - Dokument zusammengefasst.)&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot;&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|- class=&amp;quot;hintergrundfarbe6&amp;quot;&lt;br /&gt;
!style=&amp;quot;width:30%&amp;quot;| Autor!! style=&amp;quot;width:30%&amp;quot; | Titel!! style=&amp;quot;width:30%&amp;quot; | Publikation&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Abbiss, C.R.; Quod, M.J.; Martin, David T.; Netto, K.J.; Nosaka, K.; Lee, H. et al. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Dynamic pacing strategies during the cycle phase of an Ironman triathlon.  &lt;br /&gt;
|style=&amp;quot;vertical-align:top&amp;quot;| Med Sci Sports Exerc 38 (4), S. 726–734&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Abbiss, C.R.; Quod, M.J.; Levin, G.; Martin, D.T.; Laursen, P.B. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Accuracy of the Velotron ergometer and SRM power meter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 30 (2), S. 107–112.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Abel, T.; Burkett, B.; Schneider, S.; Lindschulten, R.; Strüder, H. K. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The exercise profile of an ultra-long handcycling race: the Styrkeprøven experience.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Spinal Cord 48 (12), S. 894–898.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Antonutto, G.; Capelli, C.; Girardis, M.; Zamparo, P.; di Prampero P.E. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of microgravity on maximal power of lower limbs during very short efforts in humans.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Physiol 86(1), S. 85-92.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Arkesteijn, M.; Hopker, J.; Jobson, S.; Passfield, L. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The Effect of Turbo Trainer Cycling on Pedalling Technique and Cycling Efficiency.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 34 (06), S. 520–525&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M. J.; Gore, C. J.; Burge, C. M.; Clough, M. L.; Bourdon, P. C.; Dobson, G. P.; Hahn, A. G. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Skin-prick blood samples are reliable for estimating Hb mass with the CO-dilution technique.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 79 (6), S. 535–537.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M. J.; Gore, C. J.; Dobson, G. P.; Boston, T. T.; Parisotto, R.; Emslie, K. R. et al. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Simulated moderate altitude elevates serum erythropoietin but does not increase reticulocyte production in well-trained runners.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 81 (5), S. 428–435&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Gore, C. J.; Dobson, G. P.; Hahn, A. G. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| &amp;quot;Live high, train low&amp;quot; does not change the total haemoglobin mass of male endurance athletes sleeping at a simulated altitude of 3000 m for 23 nights. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 80 (5), S. 479–484.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Gore, C. J.; Martin, D. T.; Dobson, G. P.; Hahn, A. G. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of a 12-day &amp;quot;live high, train low&amp;quot; camp on reticulocyte production and haemoglobin mass in elite female road cyclists.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 80 (5), S. 472–478.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Hahn, A. G.; Martin, D. T.; Logan, P.; Parisotto, R.; Gore, C. J. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| A comparison of the physiological response to simulated altitude exposure and r-HuEpo administration.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 19 (11), S. 831–837&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashenden, M.J.; Gore, C.J.; Parisotto, R.; Sharpe, K.; Hopkins, W.G.; Hahn, A.G. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effect of altitude on second-generation blood tests to detect erythropoietin abuse by athletes.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Haematologica 88 (9), S. 1053–1062&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Aughey, R. J.; Clark, S. A.; Gore, C. J.; Townsend, N. E.; Hahn, A. G.; Kinsman, T. A. et al. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Interspersed normoxia during live high, train low interventions reverses an early reduction in muscle Na+, K +ATPase activity in well-trained athletes.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 98 (3), S. 299–309&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Aughey, R. J.; Gore, C. J.; Hahn, A. G.; Garnham, A. P.; Clark, S. A.; Petersen, A. C. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Chronic intermittent hypoxia and incremental cycling exercise independently depress muscle in vitro maximal Na+-K+-ATPase activity in well-trained athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 98 (1), S. 186–192&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ashman, S.B.; Monk, T.H.; Kupfer, D.J.; Clark, C.H.; Myers, F.S.; Frank, E.; Leibenluft (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Relationship between social rhythms and mood in patients with rapid cycling bipolar disorder.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Psychiatry Res 86 (1), S. 1–8&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Austin, N.; Nilwik, R.; Herzog, W. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| In vivo operational fascicle lengths of vastus lateralis during submaximal and maximal cycling.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Biomech 43 (12), S. 2394–2399&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Balmer, J.; Bird, S.; Davison, R.C.R.; Doherty, M.; Smith, P. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Mechanically braked Wingate powers: agreement between SRM, corrected and conventional methods of measurement.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 22 (7), S. 661–667&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Bird, S.; Davison, R.; Lucia, A. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effect of age on 16.1-km time-trial performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 26 (2), S. 197–206&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Davison, R.C.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Peak power predicts performance power during an outdoor 16.1-km cycling time trial.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 32 (8), S. 1485–1490&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Balmer, J.; Davison, R.C.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reliability of an air-braked ergometer to record peak power during a maximal cycling test.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 32 (10), S. 1790–1793&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Davison, R.C.; Coleman, D.A.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The validity of power output recorded during exercise performance tests using a Kingcycle air-braked cycle ergometer when compared with an SRM powermeter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 21 (3), S. 195–199&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bassett, D.R.; Kyle, C. R.; Passfield, L.; Broker, J.P.; Burke, E.R. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Comparing cycling world hour records, 1967-1996: modeling with empirical data.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 31 (11), S. 1665–1676&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bentley, D. J.; McNaughton, L. R.; Thompson, D.; Vleck, V. E.; Batterham, A. M. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Peak power output, the lactate threshold, and time trial performance in cyclists. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 33 (12), S. 2077–2081&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Crequy, S.; Chiementin, X. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and Reliability of the G-Cog BMX Powermeter.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Bertucci, W.; Duc, S.; Villerius, V.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of the Axiom PowerTrain cycle ergometer when compared with an SRM powermeter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (1), S. 59–65&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Duc, S.; Villerius, V.; Pernin, J. N.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and reliability of the PowerTap mobile cycling powermeter when compared with the SRM Device.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (10), S. 868–873&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Grappe, F.; Girard, A.; Betik, A.; Rouillon, J.D. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects on the crank torque profile when changing pedalling cadence in level ground and uphill road cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Biomech 38 (5), S. 1003–1010&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Grappe, F.; Groslambert, A. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Laboratory versus outdoor cycling conditions: differences in pedaling biomechanics. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Biomech 23 (2), S. 87–92&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Bertucci, W.; Taiar, R.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Differences between sprint tests under laboratory and actual cycling conditions. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Med Phys Fitness 45 (3), S. 277–283&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Billaut, François; Gore, Christopher J.; Aughey, Robert J. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Enhancing team-sport athlete performance: is altitude training relevant?&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 42 (9), S. 751–767&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Brickley, G.; Dekerle, J.; Hammond, A.; Pringle, J.; Carter, H. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Assessment of Maximal Aerobic Power and Critical Power in a Single 90-s Isokinetic All-Out Cycling Test.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 28 (5), S. 414–419&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Broker, J.P.; Kyle, C.R.; Burke, E.R. (1999)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Racing cyclist power requirements in the 4000-m individual and team pursuits.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 31 (11), S. 1677–1685&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Brosnan, M. J.; Martin, D. T.; Hahn, A. G.; Gore, C. J.; Hawley, J. A. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Impaired interval exercise responses in elite female cyclists at moderate simulated altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 89 (5), S. 1819–1824&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Cangley, P.; Passfield, L.; Carter, H.; Bailey, M. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The Effect of Variable Gradients on Pacing in Cycling Time-Trials.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 32 (02), S. 132–136&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Carpes, F.P.; Rossato, M.; Faria, I.E.; Bolli Mota, C. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Bilateral pedaling asymmetry during a simulated 40-km cycling timetrial.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Med Phys Fitness 47 (1), S. 51–57&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Clark, Sally A.; Bourdon, P. C.; Schmidt, W.; Singh, B.; Cable, G.; Onus, K. J. et al. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The effect of acute simulated moderate altitude on power, performance and pacing strategies in well-trained cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 102 (1), S. 45–55&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Clark, Sally A.; Quod, M. J.; Clark, M. A.; Martin, D. T.; Saunders, P. U.; Gore, C. J. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Time course of haemoglobin mass during 21 days live high:train low simulated altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 106 (3), S. 399–406&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Clark, S.K.; Johnson, Thomas M. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Selenium stable isotope investigation into selenium biogeochemical cycling in a lacustrine environment: Sweitzer Lake, Colorado.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Environ. Qual. 39 (6), S. 2200–2210&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Coleman, D.A.; Wiles, J.D.; Nunn, M.; Smith, M.F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reliability of sprint test indices in well-trained cyclists. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (5), S. 383–387&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Doherty, M.; Balmer, J.; Davison, R.C.R.; Robinson, L.; Smith, P.M. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reliability of a combined 3-min constant load and performance cycling test.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 24 (5), S. 366–371&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Duc, S.; Betik, A-C; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| EMG activity does not change during a time trial in competitive cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (2), S. 145–150&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Duc, S.; Villerius, V.; Bertucci, W.; Pernin, J.N.; Grappe, F. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Muscular activity level during pedalling is not affected by crank inertial load.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 95 (2-3), S. 260–264&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Duc, S.; Villerius, V.; Bertucci, W.; Grappe, F. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and reproducibility of the ErgomoPro power meter compared with the SRM and Powertap power meters.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 2 (3), S. 270–281&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Eastwood, A.; Sharpe, K.; Bourdon, P.C.; Woolford, S.M.; Saunders, P.U.; Robertson, E.Y. et al. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Within-subject variation in hemoglobin mass in elite athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 44 (4), S. 725–732&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Ebert, T.R.; Martin, D.T.; McDonald, W.; Victor, J.; Plummer, J.; Withers, R.T. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Power output during women's World Cup road cycle racing.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 95 (5-6), S. 529–536&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Ebert, T.R.; Martin, D.T.; Stephens, B.; Withers, R.T. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Power output during a professional men's road-cycling tour.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 1 (4), S. 324–335&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Emonson, D. L.; Aminuddin, A. H.; Wight, R. L.; Scroop, G. C.; Gore, C. J. (1997)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Training-induced increases in sea level VO2max and endurance are not enhanced by acute hypobaric exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 76 (1), S. 8–12&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Faiss, R.; Praz, M.; Meichtry, A.; Gobelet, C.; Deriaz, O. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The effect of mountain bike suspensions on vibrations and off-road uphill performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Med Phys Fitness 47 (2), S. 151–158&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Fu, Qi; Townsend, N.E.; Shiller, S.M.; Martini, E.R.; Okazaki, K.; Shibata, S. et al. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Intermittent hypobaric hypoxia exposure does not cause sustained alterations in autonomic control of blood pressure in young athletes. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Am. J. Physiol. Regul. Integr. Comp. Physiol. 292 (5), S. R1977-84&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gardner, A.S.; Martin, J.C.; Martin, D.T.; Barras, M.; Jenkins, D.G. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Maximal torque- and power-pedaling rate relationships for elite sprint cyclists in laboratory and field tests. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 101 (3), S. 287–292&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gardner, A.S.; Martin, D.T.; Jenkins, D.G.; Dyer, I.; van Eiden, J.; Barras, M.; Martinm, J.C. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Velocity-specific fatigue: quantifying fatigue during variable velocity cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Med Sci Sports Exerc 41 (4), S. 904–911&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gardner, A.S.; Stephens, S.; Martin, D.T.; Lawton, E.; Lee, H.; Jenkins, D. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Accuracy of SRM and power tap power monitoring systems for bicycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 36 (7), S. 1252–1258&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Garvican, L.A.; Hammond, K.; Varley, Matthew C.; Gore, C.J.; Billaut, F.; Aughey, R.J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Lower Running Performance and Exacerbated Fatigue in Soccer Played at 1600 m. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Garvican, L.A.; Martin, D.T.; Clark, S.A.; Schmidt, W.F.; Gore, C.J. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Variability of erythropoietin response to sleeping at simulated altitude: a cycling case study. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 2 (3), S. 327–331.&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Garvican, L.A.; Pottgiesser, T.; Martin, D.T.; Schumacher, Y.O.; Barras, M.; Gore, C.J. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The contribution of haemoglobin mass to increases in cycling performance induced by simulated LHTL. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 111 (6), S. 1089–1101&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Garvican, L.A.; Saunders, P.U.; Pyne, D.B.; Martin, D.T.; Robertson, E.Y.; Gore, C.J. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Hemoglobin mass response to simulated hypoxia &amp;quot;blinded&amp;quot; by noisy measurement? &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 112 (10), S. 1797-8; author reply 1799&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Giacomoni, M.; Billaut, F.; Falgairette, G. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effects of the Time of Day on Repeated All-Out Cycle Performance and Short-Term Recovery Patterns. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 27 (6), S. 468–474&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| González-Haro, C.; Galilea B., P.A.; Soria, M.; Drobnic, F.; Escanero, J.F. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Comparison of nine theoretical models for estimating the mechanical power output in cycling. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Br J Sports Med 41 (8), S. 506-9; discussion 509&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| González-Haro, C.; Galilea, P.A.; Escanero, J.F. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Comparison of different theoretical models estimating peak power output and maximal oxygen uptake in trained and elite triathletes and endurance cyclists in the velodrome. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Sci 26 (6), S. 591–601&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Goosey-Tolfrey, V.; Castle, P.; Webborn, N.; Abel, T. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Aerobic capacity and peak power output of elite quadriplegic games players.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Br J Sports Med 40 (8), S. 684–687&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gordon, R.S.; Franklin, K.L.; Davies, B.; Baker, J.S. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Further mechanical considerations between polar and SRM mobile ergometer systems during laboratory-based high-intensity, intermittent cycling activity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Res Sports Med 15 (4), S. 241–247&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, Christopher John; Clark, Sally A.; Saunders, Philo U. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Nonhematological mechanisms of improved sea-level performance after hypoxic exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 39 (9), S. 1600–1609&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A. G.; Aughey, R. J.; Martin, D. T.; Ashenden, M. J.; Clark, S. A. et al. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Live high:train low increases muscle buffer capacity and submaximal cycling efficiency.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Acta Physiol. Scand. 173 (3), S. 275–286&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A. G.; Burge, C. M.; Telford, R. D. (1997)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| VO2max and haemoglobin mass of trained athletes during high intensity training.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 18 (6), S. 477–482&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore C.J.; Hahn A.G.; Scroop G.C.; Watson D.B.; Norton K.I.; Wood R.J.; Campbell D.P. (1996 )&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Increased arterial desaturation in trained cyclists during maximal exercise at 580 m altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Physiol 80(6), S. 2204-10&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A.; Rice, A.; Bourdon, P.; Lawrence, S.; Walsh, C. et al. (1998)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Altitude training at 2690m does not increase total haemoglobin mass or sea level VO2max in world champion track cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 1 (3), S. 156–170&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; Hahn, A. G. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Letter to the editors - Re: Heinicke K, Heinicke I, Schmidt W, Wolfarth B. A three-week traditional altitude training increases hemoglobin mass and red cell volume in elite biathlon athletes. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 26 (6), S. 504-5; author reply 506-7&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore C.J.; Little S.C.; Hahn A.G.; Scroop G.C.; Norton K.I.; Bourdon P.C.; Woolford (1997)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reduced performance of male and female athletes at 580 m altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol Occup Physiol 75(2), S. 136-43&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, C. J.; McSharry, P. E.; Hewitt, A. J.; Saunders, P. U. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Preparation for football competition at moderate to high altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Scand J Med Sci Sports 18 Suppl 1, S. 85–95&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gore, Christopher J.; Rodríguez, Ferran A.; Truijens, Martin J.; Townsend, Nathan E.; Stray-Gundersen, James; Levine, Benjamin D. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Increased serum erythropoietin but not red cell production after 4 wk of intermittent hypobaric hypoxia (4,000-5,500 m).&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 101 (5), S. 1386–1393&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gough, C. E.; Sharpe, K.; Garvican, L. A.; Anson, J. M.; Saunders, P. U.; Gore, C. J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The effects of injury and illness on haemoglobin mass.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 34 (9), S. 763–769&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Gough, C.E.; Saunders, P.U.; Fowlie, J.; Savage, B.; Pyne, D.B.; Anson, J.M. et al. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Influence of altitude training modality on performance and total haemoglobin mass in elite swimmers.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 112 (9), S. 3275–3285&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Groslambert, A.; Grappe, F.; Bertucci, W.; Perrey, S.; Girard, A.J.; Rouillon, J.D. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| A perceptive individual time trial performed by triathletes to estimate the anaerobic threshold. A preliminary study.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Med Phys Fitness 44 (2), S. 147–156&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Haakonssen, Eric C.; Martin, David T.; Burke, Louise M.; Jenkins, David G. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Energy expenditure of constant- and variable-intensity cycling: power meter estimates. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 45 (9), S. 1833–1840&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hahn, A. G.; Gore, C. J. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The effect of altitude on cycling performance: a challenge to traditional concepts. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 31 (7), S. 533–557&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hahn, A. G.; Gore, C. J.; Martin, D. T.; Ashenden, M. J.; Roberts, A. D.; Logan, P. A. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Hahn, A. G.; Gore, C. J.; Martin, D. T.; Ashenden, M. J.; Roberts, A. D.; Logan, P. A. (2001) &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Comp. Biochem. Physiol., Part A Mol. Integr. Physiol. 128 (4), S. 777–789&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hajoglou, A.; Foster, C.; Koning, J.J. de; Lucia, A.; Kernozek, T.W.; Porcari, J.P. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effect of warm-up on cycle time trial performance. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 37 (9), S. 1608–1614&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Hopker, J.; Myers, S.; Jobson, S.A.; Bruce, W.; Passfield, L. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of the Wattbike cycle ergometer&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 31 (10), S. 731–736&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Hurst, H.T.; Atkins, S. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Agreement between polar and SRM mobile ergometer systems during laboratory-based high-intensity, intermittent cycling activity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 24 (8), S. 863–868&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Hurst, H.T.; Atkins, S. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Power output of field-based downhill mountain biking.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 24 (10), S. 1047–1053&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Balmer, J.; Davison, R.C.; Coleman, D.A.; Bird, S.R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The validity of power output recorded during exercise performance tests using a Kingcycle air-braked cycle ergometer when compared with an SRM powermeter.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 21 (3), S. 195–199&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Jobson, S.A.; Passfield, L.; Atkinson, G.; Barton, G.; Scarf, P. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The analysis and utilization of cycling training data.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 39 (10), S. 833–844&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Jobson, S.; Woodside, J.; Passfield, L.; Nevill, A. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Allometric Scaling of Uphill Cycling Performance. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (09), S. 753–757&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Joch, W.; Ückert, S. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of Whole Body Cooling of - 110 °C on the Heart Frequency in Endurance Activity and in Resting Time. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| W. Phys Rehab Kur Med  14(3), S. 146-150&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Julian, Colleen G.; Gore, Christopher J.; Wilber, Randall L.; Daniels, Jack T.; Fredericson, Michael; Stray-Gundersen, James et al. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Intermittent normobaric hypoxia does not alter performance or erythropoietic markers in highly trained distance runners.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 96 (5), S. 1800–1807&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Karsten, B.; Jobson, S.A.; Hopker, J.; Passfield, L., Beedie, C. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The 3-min Test Does not Provide a Valid Measure of Critical Power Using the SRM Isokinetic Mode.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med. Sep 10. [Epub ahead of print]&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, T. A.; Gore, C. J.; Hahn, A. G.; Hopkins, W. G.; Hawley, J. A.; McKenna, M. J. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sleep in athletes undertaking protocols of exposure to nocturnal simulated altitude at 2650 m.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 8 (2), S. 222–232&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, T. A.; Hahn, A. G.; Gore, C. J.; Martin, D. T.; Chow, C. M. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sleep quality responses to atmospheric variation: case studies of two elite female cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 6 (4), S. 436–442&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, Tahnee A.; Hahn, Allan G.; Gore, Christopher J.; Wilsmore, Bradley R.; Martin, David T.; Chow, Chin-Moi (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Respiratory events and periodic breathing in cyclists sleeping at 2,650-m simulated altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 92 (5), S. 2114–2118&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kinsman, Tahnee A.; Townsend, Nathan E.; Gore, Christopher J.; Hahn, Allan G.; Clark, Sally A.; Aughey, Robert J. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sleep disturbance at simulated altitude indicated by stratified respiratory disturbance index but not hypoxic ventilatory response.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 94 (5-6), S. 569–575&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Kirkland, A.; Coleman, D.; Wiles, J.D.; Hopker, J. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of the Ergomopro powermeter.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (11), S. 913–916&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Loughlin, A.F.; Skiles, G.L.; Alberts, D.W.; Schaefer, W.H. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| An ion exchange liquid chromatography/mass spectrometry method for the determination of reduced and oxidized glutathione and glutathione conjugates in hepatocytes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Pharm Biomed Anal 26 (1), S. 131–142&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|MacIntosh, B.R.; Svedahl, K.; Kim, M. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Fatigue and optimal conditions for short-term work capacity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 92 (4-5), S. 369–375&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|MacRae HS-H; Hise, K.J.; Allen, P.J. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of front and dual suspension mountain bike systems on uphill cycling performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 32 (7), S. 1276–1280&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Mc Naughton, L.R.; Sherman, R.; Roberts, S.; Bentley, D.J. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Portable gas analyser Cosmed K4b2 compared to a laboratory based mass spectrometer system.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Med Phys Fitness 45 (3), S. 315–323&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| McDaniel, J.; Subudhi, A.; Martin, J.C. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Torso stabilization reduces the metabolic cost of producing cycling power.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Can J Appl Physiol 30 (4), S. 433–441&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|McLean, Blake D.; Buttifant, David; Gore, Christopher J.; White, Kevin; Liess, Carsten; Kemp, Justin (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Physiological and performance responses to a preseason altitude-training camp in elite team-sport athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 8 (4), S. 391–399&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Meyer, T.; Gabriel, H.H.W.; Auracher, M.; Scharhag, J.; Kindermann, W. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Metabolic profile of 4 h cycling in the field with varying amounts of carbohydrate supply.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 88 (4-5), S. 431–437&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Mijnarends, D.M.; Meijers, J.M.M.; Halfens, R.J.G.; Ter Borg, S.; Luiking, Y.C.; Verlaan, S. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Validity and reliability of tools to measure muscle mass, strength, and physical performance in community-dwelling older people: a systematic review.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Am Med Dir Assoc 14 (3), S. 170–178&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Millet, G.P.; Tronche, C.; Fuster, N.; Candau, R. (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Level ground and uphill cycling efficiency in seated and standing positions.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Med Sci Sports Exerc 34 (10), S. 1645–1652&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Millet, G.P.; Tronche, C.; Fuster, N.; Bentley, D.J.; Candau, R. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Validity and reliability of the Polar S710 mobile cycling powermeter.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 24 (3), S. 156–161&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Mornieux, G.; Gollhofer, A.; Stapelfeldt, B. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Muscle Coordination while Pulling up During Cycling. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 31 (12), S. 843–846&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Mornieux, G.; Stapelfeldt, B.; Gollhofer, A.; Belli, A. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effects of Pedal Type and Pull-Up Action during Cycling. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (10), S. 817–822&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Neville, V.; Pain, M.T.G.; Folland, J.P. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Aerobic power and peak power of elite America's Cup sailors. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 106 (1), S. 149–157&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Neville, V.; Pain, M.T.G.; Kantor, J.; Folland, J.P. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Influence of crank length and crank-axle height on standing armcrank (grinding) power.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 42 (2), S. 381–387&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Neville, V.; Zaher, N.; Pain, M.T.G.; Folland, J.P. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Lower limb influence on standing arm-cranking ('grinding').&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 30 (10), S. 713–718&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Neya, Mitsuo; Enoki, Taisuke; Ohiwa, Nao; Kawahara, Takashi; Gore, Christopher J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Increased hemoglobin mass and VO2max with 10 h nightly simulated altitude at 3000 m.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 8 (4), S. 366–372&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Nimmerichter, A.; Eston, R.G.; Bachl, N.; Williams, C. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Longitudinal monitoring of power output and heart rate profiles in elite cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sports Sci 29 (8), S. 831–840&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Nimmerichter, A.; Williams, C.; Bachl, N.; Eston, R. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Evaluation of a field test to assess performance in elite cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 31 (3), S. 160–166&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|O’Hara, J.; Thomas, A.; Seims, A.; Cooke, C.; King, R.F.G (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reliability of a High-Intensity Endurance Cycling Test.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 33 (01), S. 18–25&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Parisotto, R.; Gore, C. J.; Hahn, A. G.; Ashenden, M. J.; Olds, T. S.; Martin, D. T. et al. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reticulocyte parameters as potential discriminators of recombinant human erythropoietin abuse in elite athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 21 (7), S. 471–479&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Paton, C.D.; Hopkins, W.G. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Tests of cycling performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Sports Med 31 (7), S. 489–496&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Paton, C.D.; Hopkins, W.G. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Ergometer error and biological variation in power output in a performance test with three cycle ergometers.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 27 (6), S. 444–447&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Caillaud, C.; Thompson, M.W. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Central and Peripheral Fatigue during Passive and Exercise-Induced Hyperthermia &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med. Sci. Sports Exerc. 43 (9), S. 1657 – 1665&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Caillaud, C.; Thompson, M.W. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The role of aerobic fitness and exercise intensity on endurance performance in uncompensable heat stress conditions. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur J Appl Physiol  112, S. 1989 - 1999&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Cramer, M.N.; Chapman, P.G.; Caillaud, C.; Thompson, M.W. (2011)  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Cardiovascular strain impairs prolonged self-paced exercise in the heat. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Exp Physiol 96 (2), S. 134 - 144&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Périard, J.D.; Cramer, M.N.; Chapman, P.G.; Caillaud, C.; Thompson, M.W. (2011)   &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Neuromuscular function following prolonged intense self-paced exercise in hot climatic conditions. &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Appl Physiol. 111, S. 1561 – 1569&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Perrey, S.; Grappe, F.; Girard, A.; Bringard, A.; Groslambert, A.; Bertucci, W.; Rouillon, J.D. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Physiological and metabolic responses of triathletes to a simulated 30-min time-trial in cycling at self-selected intensity.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 24 (2), S. 138–143&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Pester, M.; Knorr, K.-H.; Friedrich, M.W.; Wagner, M.; Loy, A. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sulfate-reducing microorganisms in wetlands - fameless actors in carbon cycling and climate change.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Front Microbiol 3, S. 72&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Pinot, J.; Grappe, F. (2011)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The record power profile to assess performance in elite cyclists.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 32 (11), S. 839–844&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Pottgiesser, Torben; Garvican, Laura A.; Martin, David T.; Featonby, Jesse M.; Gore, Christopher J.; Schumacher, Yorck O. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Short-term hematological effects upon completion of a four-week simulated altitude camp.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Physiol Perform 7 (1), S. 79–83&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Quod, M. J.; Martin, D. T.; Martin, J. C.; Laursen, P. B. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| The Power Profile Predicts Road Cycling MMP.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 31 (06), S. 397–401&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Reiser, M.; Meyer, T.; Kindermann, W.; Daugs, R. (2000)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Transferability of workload measurements between three different types of ergometer.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 82 (3), S. 245–249&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Reiser, R.; Hart, C. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Cycling on Rollers: Kreitler Fan Resistance at Submaximal Levels of Effort.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (3), S. 212–216&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Richalet, J-P; Gore, C. J. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Live and/or sleep high:train low, using normobaric hypoxia.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Scand J Med Sci Sports 18 Suppl 1, S. 29–37&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Roberts, A. D.; Clark, S. A.; Townsend, N. E.; Anderson, M. E.; Gore, C. J.; Hahn, A. G. (2003)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Changes in performance, maximal oxygen uptake and maximal accumulated oxygen deficit after 5, 10 and 15 days of live high:train low altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Eur. J. Appl. Physiol. 88 (4-5), S. 390–395&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Robertson, E.Y.; Saunders, P.U.; Pyne, D.B.; Aughey, R.J.; Anson, J.M.; Gore, C.J. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Reproducibility of performance changes to simulated live high/train low altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 42 (2), S. 394–401&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Robertson, E.Y.; Saunders, P.U.; Pyne, D.B.; Gore, C.J.; Anson, J.M. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effectiveness of intermittent training in hypoxia combined with live high/train low.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| . J. Appl. Physiol. 110 (2), S. 379–387&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Rodríguez, F.A.; Truijens, M.J.; Townsend, N.E.; Stray-Gundersen, J.; Gore, C.J.; Levine, B.D. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Performance of runners and swimmers after four weeks of intermittent hypobaric hypoxic exposure plus sea level training.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 103 (5), S. 1523–1535&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Sassi, A.; Rampinini, E.; Martin, D.T.; Morelli, A. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Effects of gradient and speed on freely chosen cadence: the key role of crank inertial load.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Biomech 42 (2), S. 171–177&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P. U.; Telford, R. D.; Pyne, D. B.; Cunningham, R. B.; Gore, C. J.; Hahn, A. G.; Hawley, J. A. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Improved running economy in elite runners after 20 days of simulated moderate-altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J. Appl. Physiol. 96 (3), S. 931–937&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P. U.; Telford, R. D.; Pyne, D. B.; Hahn, A. G.; Gore, C. J. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Improved running economy and increased hemoglobin mass in elite runners after extended moderate altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| J Sci Med Sport 12 (1), S. 67–72&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P.U.; Ahlgrim, C.; Vallance, B.; Green, D.J.; Robertson, E.Y.; Clark, S.A. et al. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| An attempt to quantify the placebo effect from a three-week simulated altitude training camp in elite race walkers.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 5 (4), S. 521–534&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P.U.; Pyne, David B.; Gore, C.J. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Endurance training at altitude.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| High Alt. Med. Biol. 10 (2), S. 135–148&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Saunders, P.U.; Telford, R.D.; Pyne, D.D.; Gore, C.J.; Hahn, A.G. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Improved race performance in elite middle-distance runners after cumulative altitude exposure.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Physiol Perform 4 (1), S. 134–138&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Sharpe, K.; Hopkins, W.; Emslie, K.R.; Howe, C.; Trout, G.J.; Kazlauskas, R. et al. (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Development of reference ranges in elite athletes for markers of altered erythropoiesis.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Haematologica 87 (12), S. 1248–1257&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Simons, M.; van Es, E.; Hendriksen, I. (2009)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Electrically assisted cycling: a new mode for meeting physical activity guidelines?&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 41 (11), S. 2097–2102&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Smith, M.F.; Davison, R.C.; Balmer, J.; Bird, S.R. (2001)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Reliability of mean power recorded during indoor and outdoor selfpaced 40 km cycling time-trials.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 22 (4), S. 270–274&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Stapelfeldt, B.; Mornieux, G.; Oberheim, R.; Belli, A.; Gollhofer, A. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Development and evaluation of a new bicycle instrument for measurements of pedal forces and power output in cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 28 (4), S. 326–332&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Stapelfeldt, B.; Schwirtz, A.; Schumacher, Y.O.; Hillebrecht, M. (2004)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Workload demands in mountain bike racing.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 25 (4), S. 294–300&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Tomas, A.; Ross, E.Z.; Martin, J.C. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Fatigue during maximal sprint cycling: unique role of cumulative contraction cycles.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 42 (7), S. 1364–1369&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Townsend, N.E.; Gore, C.J.; Hahn, A.G.; Aughey, R.J.; Clark, S.A.; Kinsman, T.A. et al. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Hypoxic ventilatory response is correlated with increased submaximal exercise ventilation after live high, train low.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 94 (1-2), S. 207–215&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Townsend, N.E.; Gore, C.J.; Hahn, A.G.; McKenna, M.J.; Aughey, R.J.; Clark, S.A. et al. (2002)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Living high-training low increases hypoxic ventilatory response of well-trained endurance athletes.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 93 (4), S. 1498–1505&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Truijens, M.J.; Rodríguez, F.A.; Townsend, N.E.; Stray-Gundersen, J.; Gore, C.J.; Levine, B.D. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|The effect of intermittent hypobaric hypoxic exposure and sea level training on submaximal economy in well-trained swimmers and runners.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J. Appl. Physiol. 104 (2), S. 328–337&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Vaile, J.; Halson, S.; Gill, N.; Dawson, B. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Effect of Hydrotherapy on Recovery from Fatigue.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 29 (7), S. 539–544&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| van der Woude, L.H.V.; Horstman, A.; Faas, P.; Mechielsen, S.; Bafghi, H.A.; Koning, J.J. de (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Power output and metabolic cost of synchronous and asynchronous submaximal and peak level hand cycling on a motor driven treadmill in able-bodied male subjects.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Med Eng Phys 30 (5), S. 574–580&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Villerius, V.; Duc, S.; Grappe, F. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Physiological and Neuromuscular Responses of Competitive Cyclists during a Simulated Self-Paced Interval Training Session.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 29 (09), S. 770–777&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Vogt, S.; Heinrich, L.; Schumacher, Y. O.; Blum, A.; Roecker, K.; Dickhuth, H.-H.; Schmid, A. (2006)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Power output during stage racing in professional road cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Med Sci Sports Exerc 38 (1), S. 147–151&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Vogt, S.; Roecker, K.; Schumacher, Y. O.; Pottgiesser, T.; Dickhuth, H-H; Schmid, A.; Heinrich, L. (2008)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Cadence-power-relationship during decisive mountain ascents at the Tour de France.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 29 (3), S. 244–250&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
| Vogt, S.; Schumacher, Y.O.; Blum, A.; Roecker, K.; Dickhuth, H.-H.; Schmid, A.; Heinrich, L. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Cycling power output produced during flat and mountain stages in the Giro d'Italia: a case study.  &lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|J Sports Sci 25 (12), S. 1299–1305&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Vogt, S.; Schumacher, Y. O.; Roecker, K.; Dickhuth, H-H; Schoberer, U.; Schmid, A.; Heinrich, L. (2007)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Power Output during the Tour de France.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;| Int J Sports Med 28 (9), S. 756–761&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wahl, P.; Mathes, S.; Köhler, K.; Achtzehn, S.; Bloch, W.; Mester, J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Acute Metabolic, Hormonal, and Psychological Responses to Different Endurance Training Protocols.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Horm Metab Res 45 (11), S. 827–833&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wahl, P.; Schmidt, A.; deMarees, M.; Achtzehn, S.; Bloch, W.; Mester, J. (2013)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Responses of Angiogenic Growth Factors to Exercise, to Hypoxia and to Exercise under Hypoxic Conditions.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 34 (02), S. 95–100&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wiedemann, M. S. F.; Bosquet, L. (2010)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Anaerobic Work Capacity Derived from Isokinetic and Isoinertial Cycling.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Int J Sports Med 31 (02), S. 89–94&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wilson, M.G.; Lane, A.M.; Beedie, C.J.; Farooq, A. (2012)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Influence of accurate and inaccurate 'split-time' feedback upon 10-mile time trial cycling performance.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Eur. J. Appl. Physiol. 112 (1), S. 231–236&lt;br /&gt;
|- style=&amp;quot;vertical-align:top&amp;quot;&lt;br /&gt;
|Wooles, A.L.; Robinson, A.J.; Keen, P.S. (2005)&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|A Static Method for Obtaining a Calibration Factor for SRM Bicycle Power Cranks.&lt;br /&gt;
|style=&amp;quot;text-align:left&amp;quot;|Sports Engineering 8 (3), S. 137-144&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=MediaWiki:Sidebar&amp;diff=2009</id>
		<title>MediaWiki:Sidebar</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=MediaWiki:Sidebar&amp;diff=2009"/>
				<updated>2016-06-29T08:30:02Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;** de:Einleitung|Einleitung&lt;br /&gt;
&lt;br /&gt;
** de:Mechanische Grundlagen|Mechanische Grundlagen&lt;br /&gt;
** de:Elektronische Grundlagen|Elektronische Grundlagen&lt;br /&gt;
** de:Kalibrierung des Ergometers|Kalibrierung&lt;br /&gt;
** de:SRM-Online Einstellungen in der SRMWin-Software|SRM-Online Einstellungen&lt;br /&gt;
** de:SRM-Online in der praktischen Darstellung|SRM-Online Praxis&lt;br /&gt;
** de:Datenexport|Datenexport  &lt;br /&gt;
** de:Torque Analysis - Tretkraftanalyse|Tretkraftanalyse&lt;br /&gt;
** FAQ's zum SRM-Ergometer|FAQ's&lt;br /&gt;
** Troubleshooting|Troubleshooting&lt;br /&gt;
** Wartung &amp;amp; Service|Wartung &amp;amp; Service&lt;br /&gt;
** Handbücher|Handbücher&lt;br /&gt;
** Internationale Literatur zum SRM-Ergometer|Literatur&lt;br /&gt;
** Referenzen|Referenzen&lt;br /&gt;
&lt;br /&gt;
* Quick Links&lt;br /&gt;
** recentchanges-url|recentchanges&lt;br /&gt;
** {{SERVER}}{{SCRIPTPATH}}/index.php?title=MediaWiki:Sidebar&amp;amp;action=edit| Edit Navigation&lt;br /&gt;
&lt;br /&gt;
* TOOLBOX&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Main_Page&amp;diff=2008</id>
		<title>Main Page</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Main_Page&amp;diff=2008"/>
				<updated>2016-06-29T08:24:50Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{languages&lt;br /&gt;
|de=Einleitung&lt;br /&gt;
|en=Introduction&lt;br /&gt;
|cn=Introduction&lt;br /&gt;
}}&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
 File:SRM-Ergometer-01.jpg|Das SRM - Hochleistungsergometer&lt;br /&gt;
 File:SRM-Ergometer-02.jpg|Das SRM - Powermeter Wissenschaft&lt;br /&gt;
 File:SRM-Ergometer-03.jpg|Individuell einstellbare Sattelposition &lt;br /&gt;
 File:SRM-Ergometer-04.jpg|SRM Ergometer mit Mobile Support System (MSS) &lt;br /&gt;
 File:SRM-Ergometer-05.jpg|Das SRM Ergometer in der Leistunsgdiagnostik &lt;br /&gt;
 File:SRM-Ergometer-06.jpg|SRM - Software: Darstellung Testprotokoll und Torque - Analyse&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[File:SRM-Ergometer-04.jpg|thumb|SRM Ergometer mit Mobile Support System (MSS)]]&lt;br /&gt;
&lt;br /&gt;
Das so gennante SRM - Hochleistungsergometer wurde für den Einsatz mit Radfahrern in Zusammenarbeit mit dem Bund Deutscher Radfahrer (BDR), mit Peter Keen von der British Cycling Federation und mit Dr. Wolfgang Stockhausen vom Universitätsklinikum Freiburg entwickelt. &lt;br /&gt;
&lt;br /&gt;
Die Idee war es ein exaktes und wissenschaftlich zuverlässiges Ergometer zu konstruieren, welches den hohen Drehmomenten der weltweit stärksten Radfahrer widerstehen kann und diese Drehmomente auch messen kann. &lt;br /&gt;
&lt;br /&gt;
Inzwischen wird das SRM - Ergometer weltweit von renommierten Universitäten und Leistunsgdiagnostikern für wissenschaftliche Fragestellungen im Labor, für leistungsphysiologische Untersuchungen und als Trainingsgerät zur professionellen Trainingsbegleitung mit hoher Validität eingesetzt.&lt;br /&gt;
&lt;br /&gt;
Das SRM - Ergometer erlaubt eine individuelle Einstellung der Sitzposition für den Radfahrer, sowohl für Sprinter als auch für Triathleten. In das Ergometer wurden Standard - Fahrrad Teile (Lenker, Sättel, Kurbeln, etc.) und verschieden große Schwungmassen integriert. &lt;br /&gt;
&lt;br /&gt;
Dadurch kann die kinetische Energie für eine Vielzahl von verschiedenen Testprofilen  &lt;br /&gt;
simuliert und genutzt werden. Das Ziel ist es mit dem Fahren auf dem SRM - Ergometer dem realen Fahren auf dem eigenen Rad in der Ebene oder auch bergauf sehr nahe zu kommen. &lt;br /&gt;
&lt;br /&gt;
Die Steuerung der mechanischen Konstruktion der Bremsanlage des Ergometers übernimmt die dazugehörige und speziell entwickelte SRM - Software. Sie bietet eine große Flexibilität um eigene Testprotokolle mit den verschienden Arbeitsweisen des Ergometers zu programmieren.&lt;br /&gt;
&lt;br /&gt;
Für das Training und für die Leistungsdiagnostik können sowohl isokinetische als auch hyperbolische Tests für jede Art von Radfahrer generiet werden. Die Steuerung durch die Software erlaubt die Programmierung von Rampenprotokollen, alle Varianten von Stufentests und Trainingsintervalle für BMX-, Bahnrad-, Straßenfahrer, Mountainbiker und Sprinter.&lt;br /&gt;
&lt;br /&gt;
Das Herzstück des SRM - Hochleistungsergometers ist das SRM PowerMeter Wissenschaft, welches eine anerkannte wissenschaftliche Genauigkeit von ± 0,5% erreicht.&lt;br /&gt;
&lt;br /&gt;
== Technische Daten ==&lt;br /&gt;
&lt;br /&gt;
[[File:Technische-Daten-des-SRM-Ergometer.jpg|thumb|Technische Daten des SRM-Ergometers]]&lt;br /&gt;
&lt;br /&gt;
Technische Eckpunkte des Hochleistungseergometers sind: &lt;br /&gt;
&lt;br /&gt;
* SRM - Ergometer mit integriertem SRM Training System Wissenschaft Version (Messgenauigkeit +/- 0,5%)&lt;br /&gt;
* Der Rahmen ist aus hochfesten Aluminiumprofilteilen geschweißt&lt;br /&gt;
* Schwingend gelagerter Getriebeblock mit Wirbelstrombremse und variabler Schwungmasse. Die schwingende Lagerung gewährleistet eine geringe Geräuschentwicklung&lt;br /&gt;
* Die Wirbelstrombremse wird mit +/- 24 Volt vom Netzteil aus angesteuert &lt;br /&gt;
* Bremsleistung: von 20 bis 2500 Watt; kurzfristig sogar bis 4000 Watt&lt;br /&gt;
* Zwei veränderbare Schwungmassen und 14 - Gang Rohloff - Nabenschaltung simulieren authentisch die kinetische Energie und das &amp;quot;Gefühl&amp;quot; mit realistischen Geschwindigkeiten zu fahren. Dadurch ist die Anpassung an das Körpergewicht des Sportlers in kleinen Schritten möglich&lt;br /&gt;
* Sitzposition und Lenker können in verschiedenen Positionen für Fahrer zwischen 140 cm und 200 cm Größe eingestellt werden &lt;br /&gt;
* Enger Q - Faktor von 151 mm&lt;br /&gt;
* Individuell einstellbare Kurbellänge von 150 - 190 mm in 2,5 mm Schritten&lt;br /&gt;
* Isokinetischer und hyperbolischer Betriebsmodus programmierbar &lt;br /&gt;
* Einfacher Wechsel und Montagemöglichkeit von Standardfahrradteilen (verschiedene Kurbellängen, Pedale, Lenker, Sättel, Kettenblätter, etc.)&lt;br /&gt;
* Die SRMWin Software zur einfachen Programmierung von Tests und zur Auswertung der Daten ist im Paket enthalten.&lt;br /&gt;
* Das Gewicht liegt bei etwa 100 kg, um eine hohe Standsicherheit zu gewährleisten&lt;br /&gt;
* An der Vorderseite befinden sich zwei Rollen, auf denen das Ergometer nach Anheben der hinteren Stellbeine gut gerollt und transportiert werden kann &lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- [[en:Introduction]] --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[Category:Ergometer]]&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=MediaWiki:Sidebar&amp;diff=2007</id>
		<title>MediaWiki:Sidebar</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=MediaWiki:Sidebar&amp;diff=2007"/>
				<updated>2016-06-28T10:45:32Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;** de:Main_Page|Home&lt;br /&gt;
&lt;br /&gt;
** de:Mechanische Grundlagen|Mechanische Grundlagen&lt;br /&gt;
** de:Elektronische Grundlagen|Elektronische Grundlagen&lt;br /&gt;
** de:Kalibrierung des Ergometers|Kalibrierung&lt;br /&gt;
** de:SRM-Online Einstellungen in der SRMWin-Software|SRM-Online Einstellungen&lt;br /&gt;
** de:SRM-Online in der praktischen Darstellung|SRM-Online Praxis&lt;br /&gt;
** de:Datenexport|Datenexport  &lt;br /&gt;
** de:Torque Analysis - Tretkraftanalyse|Tretkraftanalyse&lt;br /&gt;
** FAQ's zum SRM-Ergometer|FAQ's&lt;br /&gt;
** Troubleshooting|Troubleshooting&lt;br /&gt;
** Wartung &amp;amp; Service|Wartung &amp;amp; Service&lt;br /&gt;
** Handbücher|Handbücher&lt;br /&gt;
** Internationale Literatur zum SRM-Ergometer|Literatur&lt;br /&gt;
** Referenzen|Referenzen&lt;br /&gt;
&lt;br /&gt;
* Quick Links&lt;br /&gt;
** recentchanges-url|recentchanges&lt;br /&gt;
** {{SERVER}}{{SCRIPTPATH}}/index.php?title=MediaWiki:Sidebar&amp;amp;action=edit| Edit Navigation&lt;br /&gt;
&lt;br /&gt;
* TOOLBOX&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Main_Page&amp;diff=2006</id>
		<title>Main Page</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Main_Page&amp;diff=2006"/>
				<updated>2016-06-28T10:41:13Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{languages&lt;br /&gt;
|de=Main Page&lt;br /&gt;
|en=Main Page&lt;br /&gt;
|cn=Main Page&lt;br /&gt;
}}&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
 File:SRM-Ergometer-01.jpg|Das SRM - Hochleistungsergometer&lt;br /&gt;
 File:SRM-Ergometer-02.jpg|Das SRM - Powermeter Wissenschaft&lt;br /&gt;
 File:SRM-Ergometer-03.jpg|Individuell einstellbare Sattelposition &lt;br /&gt;
 File:SRM-Ergometer-04.jpg|SRM Ergometer mit Mobile Support System (MSS) &lt;br /&gt;
 File:SRM-Ergometer-05.jpg|Das SRM Ergometer in der Leistunsgdiagnostik &lt;br /&gt;
 File:SRM-Ergometer-06.jpg|SRM - Software: Darstellung Testprotokoll und Torque - Analyse&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[File:SRM-Ergometer-04.jpg|thumb|SRM Ergometer mit Mobile Support System (MSS)]]&lt;br /&gt;
&lt;br /&gt;
Das so gennante SRM - Hochleistungsergometer wurde für den Einsatz mit Radfahrern in Zusammenarbeit mit dem Bund Deutscher Radfahrer (BDR), mit Peter Keen von der British Cycling Federation und mit Dr. Wolfgang Stockhausen vom Universitätsklinikum Freiburg entwickelt. &lt;br /&gt;
&lt;br /&gt;
Die Idee war es ein exaktes und wissenschaftlich zuverlässiges Ergometer zu konstruieren, welches den hohen Drehmomenten der weltweit stärksten Radfahrer widerstehen kann und diese Drehmomente auch messen kann. &lt;br /&gt;
&lt;br /&gt;
Inzwischen wird das SRM - Ergometer weltweit von renommierten Universitäten und Leistunsgdiagnostikern für wissenschaftliche Fragestellungen im Labor, für leistungsphysiologische Untersuchungen und als Trainingsgerät zur professionellen Trainingsbegleitung mit hoher Validität eingesetzt.&lt;br /&gt;
&lt;br /&gt;
Das SRM - Ergometer erlaubt eine individuelle Einstellung der Sitzposition für den Radfahrer, sowohl für Sprinter als auch für Triathleten. In das Ergometer wurden Standard - Fahrrad Teile (Lenker, Sättel, Kurbeln, etc.) und verschieden große Schwungmassen integriert. &lt;br /&gt;
&lt;br /&gt;
Dadurch kann die kinetische Energie für eine Vielzahl von verschiedenen Testprofilen  &lt;br /&gt;
simuliert und genutzt werden. Das Ziel ist es mit dem Fahren auf dem SRM - Ergometer dem realen Fahren auf dem eigenen Rad in der Ebene oder auch bergauf sehr nahe zu kommen. &lt;br /&gt;
&lt;br /&gt;
Die Steuerung der mechanischen Konstruktion der Bremsanlage des Ergometers übernimmt die dazugehörige und speziell entwickelte SRM - Software. Sie bietet eine große Flexibilität um eigene Testprotokolle mit den verschienden Arbeitsweisen des Ergometers zu programmieren.&lt;br /&gt;
&lt;br /&gt;
Für das Training und für die Leistungsdiagnostik können sowohl isokinetische als auch hyperbolische Tests für jede Art von Radfahrer generiet werden. Die Steuerung durch die Software erlaubt die Programmierung von Rampenprotokollen, alle Varianten von Stufentests und Trainingsintervalle für BMX-, Bahnrad-, Straßenfahrer, Mountainbiker und Sprinter.&lt;br /&gt;
&lt;br /&gt;
Das Herzstück des SRM - Hochleistungsergometers ist das SRM PowerMeter Wissenschaft, welches eine anerkannte wissenschaftliche Genauigkeit von ± 0,5% erreicht.&lt;br /&gt;
&lt;br /&gt;
== Technische Daten ==&lt;br /&gt;
&lt;br /&gt;
[[File:Technische-Daten-des-SRM-Ergometer.jpg|thumb|Technische Daten des SRM-Ergometers]]&lt;br /&gt;
&lt;br /&gt;
Technische Eckpunkte des Hochleistungseergometers sind: &lt;br /&gt;
&lt;br /&gt;
* SRM - Ergometer mit integriertem SRM Training System Wissenschaft Version (Messgenauigkeit +/- 0,5%)&lt;br /&gt;
* Der Rahmen ist aus hochfesten Aluminiumprofilteilen geschweißt&lt;br /&gt;
* Schwingend gelagerter Getriebeblock mit Wirbelstrombremse und variabler Schwungmasse. Die schwingende Lagerung gewährleistet eine geringe Geräuschentwicklung&lt;br /&gt;
* Die Wirbelstrombremse wird mit +/- 24 Volt vom Netzteil aus angesteuert &lt;br /&gt;
* Bremsleistung: von 20 bis 2500 Watt; kurzfristig sogar bis 4000 Watt&lt;br /&gt;
* Zwei veränderbare Schwungmassen und 14 - Gang Rohloff - Nabenschaltung simulieren authentisch die kinetische Energie und das &amp;quot;Gefühl&amp;quot; mit realistischen Geschwindigkeiten zu fahren. Dadurch ist die Anpassung an das Körpergewicht des Sportlers in kleinen Schritten möglich&lt;br /&gt;
* Sitzposition und Lenker können in verschiedenen Positionen für Fahrer zwischen 140 cm und 200 cm Größe eingestellt werden &lt;br /&gt;
* Enger Q - Faktor von 151 mm&lt;br /&gt;
* Individuell einstellbare Kurbellänge von 150 - 190 mm in 2,5 mm Schritten&lt;br /&gt;
* Isokinetischer und hyperbolischer Betriebsmodus programmierbar &lt;br /&gt;
* Einfacher Wechsel und Montagemöglichkeit von Standardfahrradteilen (verschiedene Kurbellängen, Pedale, Lenker, Sättel, Kettenblätter, etc.)&lt;br /&gt;
* Die SRMWin Software zur einfachen Programmierung von Tests und zur Auswertung der Daten ist im Paket enthalten.&lt;br /&gt;
* Das Gewicht liegt bei etwa 100 kg, um eine hohe Standsicherheit zu gewährleisten&lt;br /&gt;
* An der Vorderseite befinden sich zwei Rollen, auf denen das Ergometer nach Anheben der hinteren Stellbeine gut gerollt und transportiert werden kann &lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- [[en:Introduction]] --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[Category:Ergometer]]&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Main_Page&amp;diff=2005</id>
		<title>Main Page</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=Main_Page&amp;diff=2005"/>
				<updated>2016-06-28T10:37:24Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{languages&lt;br /&gt;
|de=Einleitung&lt;br /&gt;
|en=Introduction&lt;br /&gt;
|cn=Introduction&lt;br /&gt;
}}&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
 File:SRM-Ergometer-01.jpg|Das SRM - Hochleistungsergometer&lt;br /&gt;
 File:SRM-Ergometer-02.jpg|Das SRM - Powermeter Wissenschaft&lt;br /&gt;
 File:SRM-Ergometer-03.jpg|Individuell einstellbare Sattelposition &lt;br /&gt;
 File:SRM-Ergometer-04.jpg|SRM Ergometer mit Mobile Support System (MSS) &lt;br /&gt;
 File:SRM-Ergometer-05.jpg|Das SRM Ergometer in der Leistunsgdiagnostik &lt;br /&gt;
 File:SRM-Ergometer-06.jpg|SRM - Software: Darstellung Testprotokoll und Torque - Analyse&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[File:SRM-Ergometer-04.jpg|thumb|SRM Ergometer mit Mobile Support System (MSS)]]&lt;br /&gt;
&lt;br /&gt;
Das so gennante SRM - Hochleistungsergometer wurde für den Einsatz mit Radfahrern in Zusammenarbeit mit dem Bund Deutscher Radfahrer (BDR), mit Peter Keen von der British Cycling Federation und mit Dr. Wolfgang Stockhausen vom Universitätsklinikum Freiburg entwickelt. &lt;br /&gt;
&lt;br /&gt;
Die Idee war es ein exaktes und wissenschaftlich zuverlässiges Ergometer zu konstruieren, welches den hohen Drehmomenten der weltweit stärksten Radfahrer widerstehen kann und diese Drehmomente auch messen kann. &lt;br /&gt;
&lt;br /&gt;
Inzwischen wird das SRM - Ergometer weltweit von renommierten Universitäten und Leistunsgdiagnostikern für wissenschaftliche Fragestellungen im Labor, für leistungsphysiologische Untersuchungen und als Trainingsgerät zur professionellen Trainingsbegleitung mit hoher Validität eingesetzt.&lt;br /&gt;
&lt;br /&gt;
Das SRM - Ergometer erlaubt eine individuelle Einstellung der Sitzposition für den Radfahrer, sowohl für Sprinter als auch für Triathleten. In das Ergometer wurden Standard - Fahrrad Teile (Lenker, Sättel, Kurbeln, etc.) und verschieden große Schwungmassen integriert. &lt;br /&gt;
&lt;br /&gt;
Dadurch kann die kinetische Energie für eine Vielzahl von verschiedenen Testprofilen  &lt;br /&gt;
simuliert und genutzt werden. Das Ziel ist es mit dem Fahren auf dem SRM - Ergometer dem realen Fahren auf dem eigenen Rad in der Ebene oder auch bergauf sehr nahe zu kommen. &lt;br /&gt;
&lt;br /&gt;
Die Steuerung der mechanischen Konstruktion der Bremsanlage des Ergometers übernimmt die dazugehörige und speziell entwickelte SRM - Software. Sie bietet eine große Flexibilität um eigene Testprotokolle mit den verschienden Arbeitsweisen des Ergometers zu programmieren.&lt;br /&gt;
&lt;br /&gt;
Für das Training und für die Leistungsdiagnostik können sowohl isokinetische als auch hyperbolische Tests für jede Art von Radfahrer generiet werden. Die Steuerung durch die Software erlaubt die Programmierung von Rampenprotokollen, alle Varianten von Stufentests und Trainingsintervalle für BMX-, Bahnrad-, Straßenfahrer, Mountainbiker und Sprinter.&lt;br /&gt;
&lt;br /&gt;
Das Herzstück des SRM - Hochleistungsergometers ist das SRM PowerMeter Wissenschaft, welches eine anerkannte wissenschaftliche Genauigkeit von ± 0,5% erreicht.&lt;br /&gt;
&lt;br /&gt;
== Technische Daten ==&lt;br /&gt;
&lt;br /&gt;
[[File:Technische-Daten-des-SRM-Ergometer.jpg|thumb|Technische Daten des SRM-Ergometers]]&lt;br /&gt;
&lt;br /&gt;
Technische Eckpunkte des Hochleistungseergometers sind: &lt;br /&gt;
&lt;br /&gt;
* SRM - Ergometer mit integriertem SRM Training System Wissenschaft Version (Messgenauigkeit +/- 0,5%)&lt;br /&gt;
* Der Rahmen ist aus hochfesten Aluminiumprofilteilen geschweißt&lt;br /&gt;
* Schwingend gelagerter Getriebeblock mit Wirbelstrombremse und variabler Schwungmasse. Die schwingende Lagerung gewährleistet eine geringe Geräuschentwicklung&lt;br /&gt;
* Die Wirbelstrombremse wird mit +/- 24 Volt vom Netzteil aus angesteuert &lt;br /&gt;
* Bremsleistung: von 20 bis 2500 Watt; kurzfristig sogar bis 4000 Watt&lt;br /&gt;
* Zwei veränderbare Schwungmassen und 14 - Gang Rohloff - Nabenschaltung simulieren authentisch die kinetische Energie und das &amp;quot;Gefühl&amp;quot; mit realistischen Geschwindigkeiten zu fahren. Dadurch ist die Anpassung an das Körpergewicht des Sportlers in kleinen Schritten möglich&lt;br /&gt;
* Sitzposition und Lenker können in verschiedenen Positionen für Fahrer zwischen 140 cm und 200 cm Größe eingestellt werden &lt;br /&gt;
* Enger Q - Faktor von 151 mm&lt;br /&gt;
* Individuell einstellbare Kurbellänge von 150 - 190 mm in 2,5 mm Schritten&lt;br /&gt;
* Isokinetischer und hyperbolischer Betriebsmodus programmierbar &lt;br /&gt;
* Einfacher Wechsel und Montagemöglichkeit von Standardfahrradteilen (verschiedene Kurbellängen, Pedale, Lenker, Sättel, Kettenblätter, etc.)&lt;br /&gt;
* Die SRMWin Software zur einfachen Programmierung von Tests und zur Auswertung der Daten ist im Paket enthalten.&lt;br /&gt;
* Das Gewicht liegt bei etwa 100 kg, um eine hohe Standsicherheit zu gewährleisten&lt;br /&gt;
* An der Vorderseite befinden sich zwei Rollen, auf denen das Ergometer nach Anheben der hinteren Stellbeine gut gerollt und transportiert werden kann &lt;br /&gt;
&lt;br /&gt;
&amp;lt;!-- [[en:Introduction]] --&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[Category:Ergometer]]&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=File:Seatpost-designations.jpg&amp;diff=2004</id>
		<title>File:Seatpost-designations.jpg</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=File:Seatpost-designations.jpg&amp;diff=2004"/>
				<updated>2016-06-28T09:21:39Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: Seatpost designations&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Seatpost designations&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	<entry>
		<id>https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=File:Handlebar-designations.jpg&amp;diff=2003</id>
		<title>File:Handlebar-designations.jpg</title>
		<link rel="alternate" type="text/html" href="https://www.fokus-diagnostik.de/dokumentation/srm/ergometer/01/index.php?title=File:Handlebar-designations.jpg&amp;diff=2003"/>
				<updated>2016-06-28T09:21:15Z</updated>
		
		<summary type="html">&lt;p&gt;Administrator: Handlebar designations&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Handlebar designations&lt;/div&gt;</summary>
		<author><name>Administrator</name></author>	</entry>

	</feed>